Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

Construction of electrochemical flow immunoassay system using capillary columns and ferrocene conjugated immunoglobulin G for detection of human chorionic gonadotrophin.

In this paper is reported a miniaturized flow immunoassay system. Ferrocenecarboxylic acid (Fc) conjugated with anti-HCG immunoglobulin G (IgG) antibody (Fc-IgG) was prepared, and used as a novel analytical reagent. The system consists of the immunoreaction section, the capillary column packed with cation exchange resin, and the flow cell for electrochemical detection of Fc-IgG. Antibody-antigen complexes were separated from their free conjugate on the basis of differences in isoelectric point (pI) using a cation exchange capillary column. The assay yielded a linear relationship between signal and HCG concentration in the range 0-2000 mIU/ml. This simple technique enables the assay of HCG within 2 min. The cation exchange capillary column was regenerated by occasional elution with malonate buffer (pH 6.0) containing 0.5 M NaCl, to remove free conjugate. Free conjugate recovered in this manner could be reused up to eight times without significant decreases in the sensitivity of the immunoassay. This electrochemical flow immunoassay requires only minute quantities of serum and generates highly reproducible results.

Antigen-Antibody Complex↗

Optical multiple-analyte immunosensor for water pollution control.

A prototype of a portable optical immunosensor (called river analyser) has been developed. It can be applied for the monitoring of surface water quality. Antibodies carrying a fluorescent label are used for the specific recognition of pollutants, such as frequently applied pesticides. The transduction principle is based on total internal reflection fluorescence (TIRF). The outstanding advantage of the river analyser is, that at least three analytes can be detected simultaneously in one sample. Test cycles and fluid handling are automated and enable unattended measuring.

Calibration↗

Microbial biosensor array with transport mutants of Escherichia coli K12 for the simultaneous determination of mono-and disaccharides.

An automated flow-injection system with an integrated biosensor array using bacterial cells for the selective and simultaneous determination various mono- and disaccharides is described. The selectivity of the individually addressable sensors of the array was achieved by the combination of the metabolic response, measured as the O(2) consumption, of bacterial mutants of Escherichia coli K12 lacking different transport systems for individual carbohydrates. Kappa-carrageenan was used as immobilization matrix for entrapment of the bacterial cells in front of 6 individually addressable working electrodes of a screen-printed sensor array. The local consumption of molecular oxygen caused by the metabolic activity of the immobilized cells was amperometrically determined at the underlying screen-printed gold electrodes at a working potential of -600 mV vs. Ag/AgCl. Addition of mono- or disaccharides for which functional transport systems exist in the used transport mutant strains of E. coli K12 leads to an enhanced metabolic activity of the immobilized bacterial cells and to a concomitant depletion of oxygen at the electrode. Parallel determination of fructose, glucose, and sucrose was performed demonstrating the high selectivity of the proposed analytical system.

Biofilms↗

Design and fabrication of a silica on silicon integrated optical biochip as a fluorescence microarray platform.

Previous research into the use of Flame Hydrolysis Deposition (FHD) of glasses in integrated optics has focused on the successful commercial exploitation of low cost optical devices within the field of telecommunications and optoelectronics. Recently we have sought to apply these fabrication technologies to the development of optical biochips, utilising their ability to be integrated with microfluidics as a 'Lab-on-a-chip' platform. In this paper, we carry this development forward by seeking to create a microarray of integrated optical sensing elements, addressed using a glass-polymer hybrid technology in which poly(dimethylsiloxane), PDMS, is used as an elastomeric packaging over-layer. In particular, we describe the wide range of modelling and microfabrication processes required for the successful manufacture, integration and packaging of such arrays. The integration of both optical and fluidic circuits in this device avoids precise alignment requirements and results in a compact, robust and reliable device. Finally, in this paper, we describe the implementation of a pumping system for delivering small amounts of fluid across the array together with an optical signal treatment.

Carbocyanines↗

Flow injection amperometric detection of OP nerve agents based on an organophosphorus-hydrolase biosensor detector.

A flow-injection system with an organophosphorus-hydrolase (OPH)-biosensor detector has been developed and characterized for the rapid detection of organophosphorus (OP) nerve agents. The enzyme was immobilized onto a thin-film gold detector through a cystamine-glutaraldehyde coupling. Factors influencing the performance were optimized. The resulting flow system offered a fast, sensitive, selective, and stable response. The peak current increased linearly with the concentration of paraoxon and methyl parathion over the 1-10 microM range (sensitivity, 2.29 and 1.04 nA/microM, respectively). The OPH-biosensor flow injection systems offered low detection limits (e.g. 0.1 microM paraoxon), along with a good precision (R.S.D. of 3.6% for 20 successive injections of a 1.0 microM paraoxon solution). The OPH-biosensor flow detector offers great promise for rapid field screening of OP pesticides and nerve agents.

Aryldialkylphosphatase↗

Electrochemiluminescence flow injection immunoassay for atrazine.

Antibodies to atrazine were labelled with glucose oxidase and used in colorimetric enzyme linked immunosorbent assays. Transparent aminosilanized indium tin oxide coated glass electrodes were derivatized with aminodextran covalently modified with atrazine caproic acid. The labelled antibodies were used to investigate the derivatized electrodes colorimetrically and the electrodes were use in an electrochemiluminescence flow injection analyser. Electrochemiluminescence immunoassay for atrazine in the range 0-10 ppb showed that it was possible to detect less than 0.1 ppb, the precautionary limit for pesticides in drinking water recommended by the European Commission.

Antibodies, Monoclonal↗

A chemiluminescent FIA biosensor for phosphate ion monitoring using pyruvate oxidase.

We have constructed an automatic phosphate ion sensing system for the quality control of drinking water. The analyte was detected using the phosphate ion-dependent pyruvate oxidase reaction and the hydrogen peroxide produced was detected by luminol chemiluminescence catalyzed by Arthromyces ramosus peroxidase. We obtained a detection limit of 0.16 microM phosphate ion (5 ppb phosphorus) and it was possible to detect 0.32 microM phosphate ion for 48 days using pyruvate oxidase immobilized on Chitopearl BCW-2601 beads. An excellent correlation (r2 = 1.00) was obtained between the results obtained using our phosphate ion sensor and those using a modified Molybdenum Blue method.

Automation↗

DNA optical sensor: a rapid method for the detection of DNA hybridization.

A DNA optical sensor system is proposed based on the combination of sandwich solution hybridization, magnetic bead capture, flow injection and chemiluminescence for rapid detection of DNA hybridization. Bacterial alkaline phosphatase (phoA) gene and Hepatitis B virus (HBV) DNA were used as target DNA. A biotinylated DNA probe was used to capture the target gene onto the streptavidin-coated magnetic beads and a calf intestine alkaline phosphatase (CAP)-labelled DNA probe was used for subsequent enzymatic chemiluminescence detection. The detection cycle was less than 30 min, excluding the DNA hybridization time, which was about 100 min. Both the phoA gene and HBV DNA could be detected at picogramme or femtomole level. No response signal was obtained when target DNA did not exist in the sample. Successive sample detection could be made by removing the magnetic field and a washing step.

Biosensing Techniques↗

Electropolymerization of pyrrole and immobilization of glucose oxidase in a flow system: influence of the operating conditions on analytical performance.

The in situ potentiostatic electropolymerization of pyrrole (Py) on a Pt electrode in a thin-layer amperometric cell and the entrapment of the enzyme glucose oxidase (GOx) for the determination of glucose are reported. Polypyrrole (PPy) is directly formed by continuous passage of a buffered solution of the monomer (0.4 M) and enzyme (250 U mL-1) at pH 7 at a flow rate of 0.05-0.1 mL min-1 under a constant applied potential of +0.85 V vs Ag/AgCl decreases. The electrosynthesis of PPy by injection of 500 microL of a Py + GOx solution in a carrier electrolyte consisting of 0.05 M phosphate buffer and 0.1 M KCl at pH 7.0 was also assayed. The influence of the electropolymerization conditions on the analytical response of the sensor to glucose was investigated. The analytical performance of the PPy/GOx sensor was also studied in terms of durability and storage life, as well as selectivity against electroactive species such as ascorbic acid and uric acid as a function of the thickness of the polymer film formed.

Electrochemistry↗

Development of an automated microbial sensor system.

An automated whole cell biosensor system was developed by integration of immobilized microbial cells in a flow-through system with screen-printed flow-through electrodes as detectors. The detectors used were thick-film Pt-electrodes in a 3-electrode configuration constructed as sandwich flow-through cells with a volume of about 36 microliters polarized at -900 mV. The measuring principle was the determination of oxygen consumption due to the microbial metabolism. Fructose was used as model analyte. The microorganisms were immobilized on cellulose-acetate membranes and integrated into a newly created reaction chamber (membrane reactor). The microbial cells used were Rhodococcus erythropolis and Issatchenkia orientalis known to be suitable for the determination of biological oxygen demand.

Biosensing Techniques↗

Determination of the ratio of D- and L-amino acids in brewing by an immobilised amino acid oxidase enzyme reactor coupled to amperometric detection.

To determine the quantity of free amino acids, the D- and L-forms separately, is an important task in modern nutritional studies. The aim of our present work was to develop rapid, routine methods for fast determination of the different forms of free amino acids. We utilized two enzymes (L-amino acid oxidase, D-amino acid oxidase) with broad specificity. In our home-made reactors, the enzymes were immobilized in a thin-layer Plexi-cell on natural protein membrane. The enzyme-cell was built into a FIA system and the hydrogen peroxide generated during the enzymatic reaction was determined by an amperometric detector. The electrode potential was fixed at +100 mV. The parameters for the biochemical and electrochemical reactions were optimized in each case. The optimal pH value for measuring L- and D-amino acids was found ca. 8.8 and 9.5, respectively. The LAO reactor could be used for more than 900 measurements, while the DAO reactor for about 1000 measurements. The working concentration range was between 0.1-3 and 0.2-3 mM, respectively. The same standard solution (L- and D-Methionine, 1 mM) was injected 25 times sequentially and the standard deviations were 2 and 2.7%, respectively. After determining the optimal parameters, the specificity of the immobilized enzyme preparations towards different amino acids and in samples from different stages of brewing was investigated.

Amino Acid Oxidoreductases↗

Bioprocess monitoring.

Electrochemical sensors for pH and dissolved oxygen remain the most commonly used in bioprocess monitoring, but continued research has resulted in improved optical sensors. Optical sensors for dissolved oxygen and dissolved carbon dioxide are now commercially available. Advances in optics and electronics are further driving down the costs of these sensors. In the near future, bioprocess optimization will change paradigms as massively parallel, fully instrumented bioreactors become available and high-throughput bioprocessing becomes a reality.

Bioreactors↗

In vitro monitoring sub-nanogram amounts analgin in human urine by its inhibitory of the luminol-periodate chemiluminescence reaction using reagent immobilization release technique.

A selective and sensitive as well as rapid chemiluminescence (CL) flow sensor for the determination of analgin is described. The analytical reagents involved in chemiluminescence reaction, luminol and periodate, were both immobilized on an anion-exchange column. The CL signals produced by the reaction between luminol and periodate, which were eluted from the column through water injection, were decreased in the presence of analgin. Analgin was sensed by measuring the decrement of CL intensity, and which was observed linear over the logarithm of analgin concentration range of 0.1 to 50.0 ng mL(-1), and the limit of detection was 0.04 ng mL(-1) (3ó). At a flow rate of 2.0 mL min(-1), including sampling and washing, the detection could be performed in 0.5 min with a relative standard deviation of less than 3.0%. The proposed procedure was applied successfully in the monitoring of analgin in human urine samples without any pre-treatment process. It was found that the analgin concentration reached its maximum after being orally administrated for 4 h, and the analgin metabolism ratio in 10 h was 9.28% in the body of volunteers. The flow sensor offered reagentless procedures and remarkable stability in determination of analgin, and could be easily reused over 80 h.

Anti-Inflammatory Agents, Non-Steroidal↗

Stable association complex electrospray mass spectrometry for the determination of cyanuric acid.

Cyanuric acid, a suspected gastrointestinal or liver toxicant, has gained interest as a potential degradation product of triazine herbicides, such as simazine and atrazine. This paper investigates the determination of cyanuric acid by stable association complex electrospray mass spectrometry (cESI-MS). The cyanuric acid is extracted from the water through a microscale liquid-liquid extraction. The extract is evaporated to dryness, and an aqueous solution of quaternary ammonium cationic surfactant is added. When injected into the electrospray mass spectrometer, the surfactant and the cyanuric acid form a mass-selective stable association complex, which may be used for confident quantification of cyanuric acid. Several extraction solvents and surfactants were investigated. These studies provide insight into the mechanism of electrospray for the formation of these complexes, specifically with regard to the surface activity of the different surfactants and the chemistry of the surfactant-cyanuric acid complexes. From an analytical standpoint, the cESI-MS method detection limit for extraction of a 1 mL aqueous solution of cyanuric acid was 130 microg/L based on 3.14sigma(n-1) of seven replicate injections. Standard additions were used for quantification of eight aqueous samples. The cyanuric acid concentrations determined with cESI-MS were not significantly different at the 95% confidence level to those determined by conventional high-performance liquid chromatography (HPLC). A recovery of 100% from a fortified urine sample illustrates the robustness of the technique.

Chromatography, High Pressure Liquid↗

Initial hydrophobic collapse is not necessary for folding RNase A.

BACKGROUND: One of the main distinctions between different theories describing protein folding is the predicted sequence of secondary structure formation and compaction during the folding process. Whether secondary structure formation precedes compaction of the protein molecules or secondary structure formation is driven by a hydrophobic collapse cannot be decided unequivocally on the basis of existing experimental data. RESULTS: In this study, we investigate the refolding of chemically denatured, disulfide-intact ribonuclease A (RNase A) by monitoring compaction and secondary structure formation using stopped-flow dynamic light scattering and stopped-flow CD, respectively. Our data reveal the formation of a considerable amount of secondary structure early in the refolding of the slow folding species of RNase A without a significant compaction of the molecules. A simultaneous formation of secondary structure and compaction is observed in the subsequent rate-limiting step of folding. CONCLUSIONS: During folding of RNase A an initial global hydrophobicity is not observed, which contradicts the view that this is a general requirement for protein folding. This folding behavior could be typical of similar, moderately hydrophobic proteins.

Circular Dichroism↗

Spectrofluorimetric flow injection determination of trace amounts of periodate.

A sensitive, rapid and selective procedure is proposed for the flow injection determinations of periodate by spectrofluorometric detection. The method is based on the reaction of periodate with Alizarin Navy Blue in basic solution. The reagents and manifold variables influence on the sensitivity have been investigated and the optimum conditions are established. Periodate can be determined for the range of 0.250-5.00 microg ml(-1) with a limit of detection of 0.08 microg ml(-1), and with a sample rate of 15 +/- 2 samples h(-1). The relative standard deviations for eight replicate determination of 0.500 and 5.00 microg ml(-1) was 1.3 and 1.1%, respectively. Periodate can be determined in the presence of iodate and bromate. The proposed method was used to determination of periodate in water samples.

Anthraquinones↗

Flow-injection chemiluminescence study of Ce(IV)-Na2SO3-Tb(III)-fluoquinolone antibiotic system with DNA.

A novel flow injection chemiluminescence (CL) system is developed to determine DNA. According to the fact that DNA linearly quenches the CL intensity of Ce(IV)-Na(2)SO(3)-Tb(III)-fluoquinolone antibiotic (FLUQ) system, DNA concentration is determined. The calibration graphs are linear in the range of 0.04-10 microg/ml (for both natural and denatured DNA), and the 3sigma limits of detection are 7.8 ng/ml (natural DNA) and 9.5 ng/ml (denatured DNA). According to fluorescence spectrum and CL spectrum, and through studying the reaction of Ce(IV)-Na(2)SO(3)-Tb(III)-FLUQ with nucleotides and bases, we conclude that DNA counteracts the energy transfer from FLUQ to Tb(III), and this function is related to both bases and phosphate groups in DNA.

Cerium↗

Sequential flow injection determination of iodate and periodate with spectrophotometric detection.

A flow injection (FI) system is described for the sequential determination of periodate and iodate based on their reaction with iodide at pH 3.5. Two sample plugs were injected into the same carrier stream sequentially. One injection is for the iodate determination and the other for the sum of iodate and periodate determination. For iodate determination, molybdate solution buffered at pH of 3.5 was used for selective masking of periodate. The influences of reagent concentrations were studied by a univariable method and the influence of FI manifolds was studied using univariable and simplex method. Periodate and iodate can be determined in the range of 0.050-5.0 and 0.050-10 microg/ml, respectively. The 3 sigma limit of detection was 0.030 and 0.050 microg/ml for periodate and iodate, respectively. The proposed method has been applied for the sequential determinations of periodate and iodate in water samples.

Flow Injection Analysis↗