Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compression Algorithms”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,608 records · Page 90Linked to original sources

Compression sonography in patients with indeterminate or low-probability lung scans: lack of usefulness in the absence of both symptoms of deep-vein thrombosis and thromboembolic risk factors.

OBJECTIVE: We sought to determine whether compression sonography could be eliminated in the evaluation of patients who lacked both thromboembolic risk factors and symptoms of deep-vein thrombosis and who had an indeterminate or low-probability lung scan. MATERIALS AND METHODS: The medical records of 155 consecutive patients who underwent bilateral lower-extremity sonography after an indeterminate or low-probability lung scan were reviewed. The presence of thromboembolic risk factors and deep-vein thrombosis symptoms and the result of sonography were recorded. Patients were divided into two groups: group 1 consisted of patients with either thromboembolic risk factors or deep-vein thrombosis symptoms, and group 2 consisted of patients without thromboembolic risk factors and without deep-vein thrombosis symptoms. The incidences of deep-vein thrombosis in groups 1 and 2 were compared by use of a two-tailed Fisher's exact test. RESULTS: Thromboembolic risk factors or deep-vein thrombosis symptoms were found in 109 of 155 patients (70%) (group 1). Deep-vein thrombosis was found in nine of 108 patients (8%) in group 1. Both thromboembolic risk factors and deep-vein thrombosis symptoms were absent in 47 of 155 patients (30%) (group 2). Deep-vein thrombosis was found in none of 47 patients (95% confidence interval, 0-8%) in group 2. The difference in the incidences of deep-vein thrombosis in groups 1 and 2 approached statistical significance (p = .0579). The negative predictive value of the absence of both thromboembolic risk factors and deep-vein thrombosis symptoms in excluding deep-vein thrombosis was 100% (95% confidence interval, 93-100%). CONCLUSION: If both symptoms of deep-vein thrombosis and thromboembolic risk factors are absent, the usefulness of lower-extremity sonography in detecting deep-vein thrombosis in patients with an indeterminate or low-probability lung scan is low. The manner in which these findings may be used to modify individual practice patterns will undoubtedly depend on the rate of detection of deep-vein thrombosis at a given institution.

Algorithms↗

Finite element modeling of damage accumulation in trabecular bone under cyclic loading.

A two-dimensional finite element model of an idealized trabecular bone specimen was developed to study trabecular bone damage accumulation during cyclic compressive loading. The specimen was modeled as a two-dimensional honeycomb-like structure made up of an array of hexagonal cells. Each trabecula was modeled as a linearly elastic beam element with the same material properties as cortical bone. Initial microcracks were assumed to exist within the oblique trabeculae and to grow according to the Paris law. Forces and moments were computed in each trabecula and the microcracks were allowed to propagate until fracture occurred. Between cycles, fractured trabeculae were removed from the finite element mesh, and force and moment distributions were calculated for the next cycle. This iterative process was continued until the simulated trabecular bone specimen showed a 10% reduction in modulus. Creep failure was also studied using a single cell analysis, in which a closed-form solution was obtained after prescribing the creep properties of the trabeculae. The results of the crack propagation analysis showed that fractures of only a small number of individual trabeculae can cause a substantial reduction in the modulus of the trabecular bone specimen model. Statistical tests were performed to compare the slopes and intercepts of the S-N curves of our model predictions to those of experimentally derived S-N curves for bovine trabecular bone. There was no significant difference (p > 0.2 for both slope and intercept) between our model predictions and the experimentally derived S-N curves for the low-stress, high-cycle range. For the high-stress, low-cycle range, the crack propagation model overestimated the fatigue life for a given stress level (for slope, p < 0.001), while the creep analysis agreed well with the experimental data (for slope, p > 0.2). These findings suggest that the primary failure mechanism for low-stress, high-cycle fatigue of trabecular bone is crack growth and propagation, while the primary failure mechanism for high-stress, low-cycle fatigue is creep deformation and fracture. Furthermore, our results suggest that the modulus of trabecular bone at the specimen level may be highly sensitive to fractures of individual trabeculae.

Algorithms↗

Different accuracies of rapid enzyme-linked immunosorbent, turbidimetric, and agglutination D-dimer assays for thrombosis exclusion: impact on diagnostic work-ups of outpatients with suspected deep vein thrombosis and pulmonary embolism.

The requirement for a safe diagnostic strategy should be based on an overall posttest incidence of venous thromboembolism (VTE) of less than 1%, with a negative predictive value of more than 99 to 100% during 3-month follow-up. Compression ultrasonography (CUS) and spiral computed tomography (CT) currently are the methods of choice to confirm or rule out deep venous thrombosis (DVT) and pulmonary embolism (PE), respectively. CUS has a negative predictive value (NPV) of 97 to 98%, indicating the need to improve the diagnostic work-up of patients with suspected DVT by clinical score assessment and D-dimer testing. Spiral CT as a stand-alone method detects all clinically relevant PEs and a large number of alternative diagnoses. It rules out PE with a NPV of 98 to 99%. Spiral CT is expensive, emphasizing the need to improve the diagnostic work-up of patients with suspected PE by the use of clinical score assessment and D-dimer testing. Clinical score assessment for DVT and PE has not safely ruled out VTE in multicenter studies and in routine daily practices. Modification of the Wells clinical score assessment for DVT by elimination of the "minus 2 points" for alternative diagnosis will improve the reproducibility of the clinical score assessment. The combination of a first negative CUS and a negative SimpliRed or an enzyme-linked immunosorbent assay (ELISA) VIDAS D-dimer of < 1,000 ng/mL safely exclude DVT (NPV > 99%) irrespective of clinical score assessment and without the need to repeat CUS in approximately 60 to 70% of patients. The rapid quantitative and qualitative agglutination D-dimer assays for the exclusion of VTE are not sensitive enough as stand-alone tests and should be used in combination with clinical score assessment. A normal rapid ELISA VIDAS D-dimer test as a stand-alone test safely excludes DVT and PE, with a NPV of 99 to 100%, irrespective of clinical score, without the need of CUS or spiral CT. The combined strategy of a rapid ELISA VIDAS D-dimer followed by objective testing with CUS for DVT and by spiral CT for PE will reduce the need for noninvasive imaging techniques by 40 to 50%.

Algorithms↗

Cost-effectiveness of noninvasive diagnostic aids in suspected pulmonary embolism.

BACKGROUND: Noninvasive instruments such as plasma D-dimer measurement (DD) and lower-limb compression ultrasonography (US) are being increasingly advocated to reduce the number of necessary angiograms in patients having suspected pulmonary embolism (PE) and a nondiagnostic lung scan. We therefore designed a decision analysis model (1) to evaluate the cost-effectiveness of combining these noninvasive diagnostic aids with lung scan and angiography in the diagnosis of PE and (2) to determine the optimal sequence and combination of tests taking into account the clinical probability of PE. METHODS: We performed a cost-effectiveness analysis based on literature data, including data from a management study in our institution. Six diagnostic strategies were compared with the reference, ie, lung scan followed when nondiagnostic (low or intermediate probability) by angiography. In all strategies, PE was ruled out by a normal or near-normal scan, a negative DD (plasma level below 500 micrograms/L), or a negative angiogram. Pulmonary embolism was diagnosed and anticoagulant treatment was undertaken in the presence of a high-probability lung scan, deep vein thrombosis showed by US, or a positive angiogram. In case of a nondiagnostic scan (low or intermediate probability), patients could be either treated or not treated, or undergo other tests, according to the selected strategy. RESULTS: Under baseline conditions (prevalence of PE, 35%), strategies combining DD and US with lung scan, angiography being done only in case of an inconclusive noninvasive workup (DD level > 500 micrograms/L, normal US, and nondiagnostic lung scan), were most cost-effective. This approach yielded a 9% incremental cost reduction and a 37% to 47% decrease in the number of necessary angiograms compared with the reference strategy (scan +/- angiography). For patients with a low clinical probability of PE (< or = 20%), withholding treatment from those with a low-probability lung scan without performing an angiogram proved safe and highly cost-effective (30% cost reduction), provided US showed no deep vein thrombosis. CONCLUSION: The DD test and US are cost-effective in the diagnostic workup of PE, whether performed after or before lung scan, thus allowing centers devoid of lung scanning and/or angiography facilities to screen patients with suspected PE and avoid costly referrals. In patients with a low clinical probability, a low-probability lung scan, and a normal US, treatment may be withheld without resorting to angiography.

Algorithms↗

Strategies for the safe and effective exclusion and diagnosis of deep vein thrombosis by the sequential use of clinical score, D-dimer testing, and compression ultrasonography.

Patients with suspected deep vein thrombosis (DVT) are subjected to leg vein compression ultrasonography (CUS) that confirms DVT in only 20 to 30% of patients. A positive CUS is consistent with DVT irrespective of clinical score. The sequential use of a simple clinical score assessment, a rapid sensitive enzyme-linked immunosorbent assay (ELISA) D-dimer test and CUS to safely exclude DVT is promising. The clinical score is a validated clinical model of complaints, signs, and symptoms, on the basis of which a pretest clinical probability for DVT can be estimated as low, moderate, and high. The safe exclusion of DVT by a rapid sensitive D-dimer test in combination with clinical score or CUS necessitates a negative predictive value of more than 99%. The negative predictive value for DVT is determined by the sensitivity of the rapid ELISA D-dimer test and the prevalence of DVT in subgroups of outpatients with suspected DVT. The prevalence of DVT in outpatients with a low, moderate, and high clinical score varies widely from 3 to 10%, 15 to 30% and more than 70%, respectively. A negative rapid ELISA D-dimer and a low clinical score (prevalence DVT 3 to 5%) will have a very high negative predictive value of more than 99.5% to exclude DVT without the need of CUS testing. A negative ELISA D-dimer test and a first-negative CUS safely exclude DVT in patients with a moderate clinical score with a negative predictive value of more than 99.5%, therefore obviating the need to repeat CUS. The use of a rapid ELISA D-dimer testing in patients with a high clinical score is not recommended. A negative CUS, a low clinical score, and a positive ELISA D-dimer, even less than 1000 ng/mL exclude DVT with a nega tive predictive value of more than 99%. Patients with a negative CUS, but a positive ELISA D-dimer, and a moderate or high clinical score have a probability of DVT of 3 to 5% and 20 to 30%, respectively, and are thus candidates for repeated CUS testing. The proposed sequential use of the clinical score assessment, a rapid ELISA D-dimer test, and CUS will be the most cost-effective diagnostic strategy for DVT because of a significant reduction of CUS examinations and gain of time for the patient and physician in charge.

Algorithms↗

Methods in quantitative image analysis.

The main steps of image analysis are image capturing, image storage (compression), correcting imaging defects (e.g. non-uniform illumination, electronic-noise, glare effect), image enhancement, segmentation of objects in the image and image measurements. Digitisation is made by a camera. The most modern types include a frame-grabber, converting the analog-to-digital signal into digital (numerical) information. The numerical information consists of the grey values describing the brightness of every point within the image, named a pixel. The information is stored in bits. Eight bits are summarised in one byte. Therefore, grey values can have a value between 0 and 256 (2(8)). The human eye seems to be quite content with a display of 5-bit images (corresponding to 64 different grey values). In a digitised image, the pixel grey values can vary within regions that are uniform in the original scene: the image is noisy. The noise is mainly manifested in the background of the image. For an optimal discrimination between different objects or features in an image, uniformity of illumination in the whole image is required. These defects can be minimised by shading correction [subtraction of a background (white) image from the original image, pixel per pixel, or division of the original image by the background image]. The brightness of an image represented by its grey values can be analysed for every single pixel or for a group of pixels. The most frequently used pixel-based image descriptors are optical density, integrated optical density, the histogram of the grey values, mean grey value and entropy. The distribution of the grey values existing within an image is one of the most important characteristics of the image. However, the histogram gives no information about the texture of the image. The simplest way to improve the contrast of an image is to expand the brightness scale by spreading the histogram out to the full available range. Rules for transforming the grey value histogram of an existing image (input image) into a new grey value histogram (output image) are most quickly handled by a look-up table (LUT). The histogram of an image can be influenced by gain, offset and gamma of the camera. Gain defines the voltage range, offset defines the reference voltage and gamma the slope of the regression line between the light intensity and the voltage of the camera. A very important descriptor of neighbourhood relations in an image is the co-occurrence matrix. The distance between the pixels (original pixel and its neighbouring pixel) can influence the various parameters calculated from the co-occurrence matrix. The main goals of image enhancement are elimination of surface roughness in an image (smoothing), correction of defects (e.g. noise), extraction of edges, identification of points, strengthening texture elements and improving contrast. In enhancement, two types of operations can be distinguished: pixel-based (point operations) and neighbourhood-based (matrix operations). The most important pixel-based operations are linear stretching of grey values, application of pre-stored LUTs and histogram equalisation. The neighbourhood-based operations work with so-called filters. These are organising elements with an original or initial point in their centre. Filters can be used to accentuate or to suppress specific structures within the image. Filters can work either in the spatial or in the frequency domain. The method used for analysing alterations of grey value intensities in the frequency domain is the Hartley transform. Filter operations in the spatial domain can be based on averaging or ranking the grey values occurring in the organising element. The most important filters, which are usually applied, are the Gaussian filter and the Laplace filter (both averaging filters), and the median filter, the top hat filter and the range operator (all ranking filters). Segmentation of objects is traditionally based on threshold grey values. (AB

Algorithms↗