Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CENTRIFUGATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

Analysis of T-cell responses in malaria-exposed and non-exposed donors using Plasmodium falciparum asexual blood stages enriched by a simple centrifugation method.

Several studies have reported on similar in vitro cellular responses to different malaria-antigen preparations in both malaria-primed and un-primed donors. Whether intact live parasites can exert a distinct type of response in either of the two groups is not well known. In this study, we developed a simple three-step centrifugation method for simultaneous enrichment of early and late blood stages from Plasmodium falciparum cultures. Such enriched P. falciparum fractions and other antigen preparations were used to stimulate lymphocytes from malaria-exposed and non-exposed individuals to examine the proliferative activity and expansion of CD3+, gammadelta+, CD4+, and CD8+ T cells. While lymphocytes from malaria non-exposed donors proliferated relatively higher than those from malaria-exposed donors in response to most antigens tested, the enriched fractions of live parasites exerted higher proliferative responses on cells from the latter donors. This suggests the existence of memory cells in the malaria-exposed donors, but not in the non-exposed ones. Flow cytometric analysis revealed a higher percentage expansion of CD4+ T cells in the responding cells of the exposed donors than the non-exposed ones. Taken together, this study reports on a simple method that simultaneously enriches for intact live early and late blood stages of P. falciparum parasites. Moreover, the study revealed higher expansion CD4+ T cells in the exposed individuals than the non-exposed in response to live malaria parasites and not to other parasite-antigen preparations.

Animals↗

Isolation of DNA-free RNA, DNA, and proteins by cesium trifluoroacetate centrifugation.

The ability to simultaneously isolate intact DNA-free RNA, genomic DNA, and proteins from a biological specimen can be useful in cloning genes and analyzing gene expression. Equilibrium density gradient centrifugation with CsCl is a useful tool for fractionating, quantitatively separating, and characterizing RNA, DNA, and the total quota of proteins, respectively, based on differences in their buoyant densities. In the present study we have reexamined the rarely used cesium salt, cesium trifluoroacetate, for the same purpose. A significant advantage of CsTFA lies in the fact that, unlike in CsCl, RNA can be recovered from a single, soluble fraction of the CsTFA gradient. Furthermore, unlike CsCl, CsTFA is freely soluble in ethanol so that co-precipitation of the salt in the recovered RNA upon alcohol precipitation does not take place. Hence, the RNA is recovered with minimum manipulations. The one-step separation of cellular macromolecule classes free of each other in small amount of starting materials provides a major advantage over other methods currently in use.

Cell Line↗

Synthesis of degradable poly(L-lactide-co-ethylene glycol) porous tubes by liquid-liquid centrifugal casting for use as nerve guidance channels.

Biodegradable nerve guidance channels are advantageous, obviating the need for their removal after regeneration; however, most channels lack the appropriate mechanical properties for soft tissue implantation and/or degrade too quickly, resulting in reduced regeneration and necessitating the need for the design of polymers with tunable degradation profiles and mechanical properties. We designed a series of biodegradable polymeric hydrogel tubes consisting of L-lactide (LLA) and polyethylene glycol (PEG) where both the ratio of LLA to PEG and PEG molar mass were varied. By adjusting the PEG:LLA ratio and the molecular weight of the PEG oligomer we were able to control degradation and mechanical properties of our polymers. By incorporating methacrylate (MA) groups on both termini of the linear oligomers, porous tubes were synthesized by a redox-initiated free radical mechanism during a liquid-liquid centrifugal casting process. The tube wall had a bead-like morphology, as determined by SEM, which was reminiscent of previous porous hydrogel tubes synthesized by the same method. Tubes swelled with degradation to 160 vol%, or 640 wt%, and an increased radius calculated at 1.26 times. Those tubes with greater PEG content and PEG molar mass degraded faster than those with greater LLA content, as was expected. Interestingly, the wall morphology changed with degradation to a fiber-like structure and the mechanical properties decreased with degradation. By correlating the accelerated degradation study to a physiologic one, these porous hydrogel tubes were stable for an equivalent of 1.5 months, after which the mechanical properties began to deteriorate. This study demonstrates how porous hydrogel tubes can be designed to meet tissue regeneration criteria by tuning the formulation chemistry and specifically how the ratio of hydrophobic/crystalline LLA and hydrophilic/amorphous PEG impact tube properties.

Absorbable Implants↗

Effect of Coriolis force on counter-current chromatographic separation by centrifugal partition chromatography.

The effect of Coriolis force on the counter-current chromatographic separation was studied using centrifugal partition chromatography (CPC) with four different two-phase solvent systems including n-hexane-acetonitrile (ACN); tert-butyl methyl ether (MtBE)-aqueous 0.1% trifluoroacetic acid (TFA) (1:1); MtBE-ACN-aqueous 0.1% TFA (2:2:3); and 12.5% (w/w) polyethylene glycol (PEG) 1000-12.5% (w/w) dibasic potassium phosphate. Each separation was performed by eluting either the upper phase in the ascending mode or the lower phase in the descending mode, each in clockwise (CW) and counterclockwise column rotation. Better partition efficiencies were attained by the CW rotation in both mobile phases in all the two-phase solvent systems examined. The mathematical analysis also revealed the Coriolis force works favorably under the CW column rotation for both mobile phases. The overall results demonstrated that the Coriolis force produces substantial effects on CPC separation in both organic-aqueous and aqueous-aqueous two-phase systems.

Centrifugation↗

Preparative counter-current chromatography purification of valrubicin (AD-32) from crude synthetic drug using upright coil planet centrifuge with four multilayer coils connected in series.

Preparative counter-current chromatography (CCC) purification of valrubicin (AD-32) from crude synthetic drug has been successfully performed for the first time using upright coil planet centrifuge with four multilayer coils connected in series with 1600 ml capacity. The two-phase system used was composed of light petroleum (bp 60-90 degrees C)-ethyl acetate-tetrachloromethane-methanol-water at an optimized volume ratio of 1:1:8:6:1. Target compound (1.2 g) with a purity of 99.88% was obtained from 1.5 g of crude synthetic drug with a purity 95.49% based on HPLC peak area percentage. Identification of the target compound was performed by electrospray ionization mass spectrometry, one- and two-dimensional nuclear magnetic resonance.

Centrifugation↗

New small-scale cross-axis coil planet centrifuge. The design of the apparatus and its application to counter-current chromatographic separation of proteins with aqueous-aqueous polymer phase systems.

The cross-axis coil planet centrifuge (X-axis CPC) is useful for partitioning macromolecules with aqueous-aqueous polymer phase systems. The floor model we have built with a pair of separation columns had some shortcomings such as requirement of large space, short life of the flow tubes, and difficulty in installing columns. In order to improve the partition efficiency and the utility of counter-current chromatography (CCC), a new small-scale X-axis CPC was designed and fabricated in our laboratory. The down-sizing of the apparatus was done by reducing the scale to about 1/2 of our original model of X-1.5L type with several improvements. Performance of the apparatus was evaluated on protein separation using an aqueous-aqueous polymer phase system composed of polyethylene glycol 1000 and dibasic potassium phosphate with four multilayer coiled columns. A series of experiments revealed that the combination of right- and left-handed coils produced the best partition efficiencies for both lower and upper mobile phases by selecting the revolution direction. The overall results indicate that the head-tail elution mode substantially affects to the peak resolution and stationary phase retention. This new X-axis CPC would be useful for the separation of various kinds of biologically active compounds.

Centrifugation↗

Multiple dual-mode centrifugal partition chromatography, a semi-continuous development mode for routine laboratory-scale purifications.

Nowadays, centrifugal partition chromatography (CPC) separations can be routinely achieved at the laboratory scale. The solvent system selection has been made easy, as generic sets of solvent systems are described in publications and books. This approach, however, generally reduces the scope of optimization strategies for two important parameters: selectivity and sample solubility. This can be very limiting for the preparative separation of structurally similar compounds. Multiple dual-mode (MDM) CPC has been developed to provide an easy-to-use alternative technique to circumvent this problem. A MDM separation consists of a succession of dual-mode runs (i.e. multiple inversion of stationary and mobile phase) that can only be achieved because both chromatographic phases are liquids. This original elution mode is thus a semi-continuous process with a classical sample injection and which only requires a single CPC column. Underlying mechanisms of MDM were studied using a model mixture of acenaphthylene and naphthalene. A mixture of two synthetic pairs of diastereomers was then successfully submitted to MDM CPC, in the framework of the synthesis of biologically active compounds.

Acenaphthenes↗

Preparative isolation of huperzines A and B from Huperzia serrata by displacement centrifugal partition chromatography.

The pH-zone refining centrifugal partition chromatography technique was used to separate the two acetylcholinesterase inhibitors huperzines A and B from a crude alkaloid extract of the club moss Huperzia serrata. Complete co-elution of huperzines A and B was initially observed with the well-known methyl tert-butyl ether-acetonitrile-water (4:1:5, v/v/v) solvent system with triethylamine (8mM) as the displacer and methane sulfonic acid (6mM) as the retainer. An efficient biphasic system was designed on the basis of solvent association that provided selectivity in the elution mode: n-heptane/ethyl acetate/n-propanol/water (5:15:35:45, v/v/v/v). Lowering the bridge solvent content (n-propanol) of this system increased the polarity difference between the two phases thus adapting it to the pH-zone refining mode. Thus, the purification of these compounds was achieved using the biphasic system n-heptane/ethyl acetate/n-propanol/water (10:30:15:45, v/v/v/v) with triethylamine (8mM) as the displacer and methane sulfonic acid (6mM) as the retainer.

Alkaloids↗

Direct quantification of protein partitioning in oil-in-water emulsion by front-face fluorescence: avoiding the need for centrifugation.

The quantification of proteins adsorbed at the oil-in-water interface is often difficult since it requires separation of fat globules from the aqueous phase that may damage the fat globule size and/or modify the interfacial composition. Front-face fluorescence spectroscopy was used to characterize the protein partitioning between the aqueous and oil phases of emulsions without separating these two phases. Different emulsions based on skim milk powder (SMP), two mono- and di-glyceride (MDG) mixtures (saturated and partially unsaturated), and three fats (hydrogenated and refined coconut oils and refined palm oil) were studied. The impact of an ageing period (24 h at 4 degrees C) was also investigated to typify the first step of ice cream processing. The emulsions were characterized for protein partitioning, immediately following emulsification and after ageing, using the Bradford spectrophotometric method, applied to the aqueous phase recovered after emulsion centrifugation. In parallel, the emulsions were characterized by their tryptophan emission fluorescence spectra. The area of the peaks at 333 nm, of the fourth-derivative fluorescence spectra corresponding to the amount of proteins present in the aqueous phase of emulsions, was well correlated with the Bradford measurements (r2=0.91). This amount was also calculated from the fluorescence calibration curve obtained with SMP in solution. In conclusion, front-face fluorescence spectroscopy appeared to be a powerful and simple technique allowing the quantification of different populations of protein in an emulsified system, i.e., in the aqueous phase and loaded at the fat globule interface.

Centrifugation↗

A novel protocol for the subcellular fractionation of C3A hepatoma cells using sucrose density gradient centrifugation.

In this paper, we describe a method to obtain a relatively pure mitochondrial and microsomal fractions by subcellular fractionation of human hepatoma cell line C3A using sucrose as the hypoosmotic medium. The cells were subjected to osmotic stress with sucrose and homogenized. Osmolarity was then restored to the cells and the organelles were separated by density gradient centrifugation. The protein profiles were examined by SDS-PAGE and the purity was analysed by marker enzymes and Western blotting. Our results indicate a good separation of mitochondrial and microsomal fractions from human hepatoma C3A cells.

Blotting, Western↗

Centrifugal partition chromatography as a tool for preparative purification of pea albumin with enhanced yields.

A new procedure including the use of centrifugal partition chromatography (CPC) is proposed to purify PA1b and its isoforms. These pea (Pisum sativum L.) seed proteins are toxic against weevils and can be used as an environment-friendly insecticide. CPC was applied to a whole albumin fraction prepared from pea flour. The butanol:aqueous TFA system used in CPC allowed the separation of PA1b from other albumins and a degree of purification above 95%. Compared to analytical procedures based on methanol extraction, anion exchange and then reversed-phase chromatography (RPC), CPC recovered PA1b in much better yield, which is indispensable for large-scale purification of a biodegradable insecticide.

Albumins↗

Physical properties of organic particulate UV-absorbers used in sunscreens. I. Determination of particle size with fiber-optic quasi-elastic light scattering (FOQELS), disc centrifugation, and laser diffractometry.

In this study microparticles consisting of a benzotriazole derivative, which are used as absorbers for UV radiation in cosmetic sunscreens, were investigated. The particles were micronized in presence of a dispersing agent by means of a ball milling process. According to the energy input different particle sizes were produced in the range of 0.16 to 4 microm. The particle sizes obtained after different stages of the micronization process were measured using fiber-optic quasi-elastic light scattering (FOQELS), disc centrifugation, and laser diffractometry. All methods showed satisfactory agreement over the whole range of sizes. With the FOQELS technique the particle size distribution could be resolved to sizes well below 0.1 microm.

Centrifugation↗

Enhanced transduction of antigen-stimulated T lymphocytes with recombinant retroviruses concentrated by centrifugal filtration.

Retroviral gene transduction of antigen-specific T cells and reintroduction of the gene-modified T cells into animals or human subjects is attractive for experimental disease-modeling applications and gene therapy approaches for autoimmune or allergic diseases. However, retrovirus titers are often a limiting factor for the efficient gene transfer of mature T cells, which have proven to be relatively refractory to gene transduction. Retrovirus-containing supernatants with titers sufficient for effective transduction of immortalized T cell lines may fail to transduce peripheral T cells. The use of high-titer retroviruses pseudotyped with vesicular stomatitis virus G protein and concentrated by ultracentrifugation is limited by the loss of specific tropism, lower lymphocyte transduction efficiency on infectious particle basis and pseudotransduction. Herein, we present a simple method to concentrate retroviruses by centrifugal filtration at low g force. We compared the ability of unconcentrated and concentrated retroviruses to transduce immortalized fibroblasts as well as primary rat splenocytes activated with antigen and we evaluated transduction efficiency and mean fluorescence intensity of transgene expression in transduced cells. Our data demonstrate that, with this technique, retrovirus titers were increased nearly 10-fold without significant loss of infectious particles. Compared to unconcentrated retroviral preparations, the concentrated retrovirus supernatants more effectively transduced antigen-stimulated, primary rat T cells. This simple method of concentrating retroviruses may be exploited to generate gene-modified T cells for gene therapy applications in animal models of human autoimmune or allergic disease and may also be applicable for T lymphocyte-based gene therapy approaches in humans.

Animals↗

Size fractionation of a rumen microbial population by counter-flow centrifugal elutriation.

The microorganisms in rumen contents were physically separated into five fractions on the basis of size using counter-flow centrifugal elutriation (CCE). The use of CCE allowed the microbial population to be separated in a highly repeatable manner into two protozoal and three bacterial fractions with minimal loss of material (dry weight), and with no visible damage to the microorganisms. A Coulter counter was used to determine the sizes of the organisms in each fraction. The modified CCE method is suitable for studies of the rumen microbial ecosystem that require separation of defined fractions of the population.

Animals↗

Inflammatory response to cardiopulmonary bypass using roller or centrifugal pumps.

BACKGROUND: The inflammatory response in 29 patients undergoing coronary artery bypass grafting using either roller or centrifugal (CFP) pumps was evaluated in a prospective study. METHODS: Patients were randomized in roller pump (n = 15) and CFP (n = 14) groups. Terminal complement complex activation (SC5b-9) and neutrophil activation (elastase) were assessed during the operation. Cytokine production (tumor necrosis factor-alpha, interleukin-6, interleukin-8) and circulating adhesion molecules (soluble endothelial-leukocyte adhesion molecule-1 and intercellular adhesion molecule-1) were assessed after the operation. RESULTS: Release of SC5b-9 after stopping cardiopulmonary bypass and after protamine administration was higher in the CFP group (p = 0.01 and p = 0.004). Elastase level was higher after stopping cardiopulmonary bypass using CFP (p = 0.006). Multivariate analysis confirmed differences between roller pump and CFP groups in complement and neutrophil activation. After the operation, a significant production of cytokines was detected similarly in both groups, with peak values observed within the range of 4 to 6 hours after starting cardiopulmonary bypass. However, interleukin-8 levels were higher using CFP 2 hours after starting cardiopulmonary bypass (p = 0.02). Plasma levels of adhesion molecules were similar in both groups within the investigation period. CONCLUSIONS: During the operation, CFP caused greater complement and neutrophil activation. After the operation, the inflammatory response was similar using either roller pump or CFP.

Cardiopulmonary Bypass↗

Determining force dependence of two-dimensional receptor-ligand binding affinity by centrifugation.

Analyses of receptor-ligand interactions are important to the understanding of cellular adhesion. Traditional methods of measuring the three-dimensional (3D) dissociation constant (Kd) require at least one of the molecular species in solution and hence cannot be directly applied to the case of cell adhesion. We describe a novel method of measuring 2D binding characteristics of receptors and ligands that are attached to surfaces and whose bonds are subjected to forces. The method utilizes a common centrifugation assay to quantify adhesion. A model for the experiment has been formulated, solved exactly, and tested carefully. The model is stochastically based and couples the bond force to the binding affinity. The method was applied to examine tumor cell adherence to recombinant E-selectin. Satisfactory agreement was found between predictions and data. The estimated zero-force 2D Kd for E-selectin/carbohydrate ligand binding was approximately 5 x 10(3) microm(-2), and the bond interaction range was subangstrom. Our results also suggest that the number of bonds mediating adhesion was small (<5).

Cell Adhesion↗

Enzymatic endpoint analysis of glucose with the hexokinase method and the Union Carbide fast centrifugal analyzer.

1. We describe an enzymatic endpoint method for glucose using the hexokinase reaction and the Union Carbide fast centrifugal analyzer. The new method permits the direct spectrophotometric measurement of serum blanks, and eliminates the need for separate blank determinations or computer-assisted calculation of the sample blank absorbance values. 2. The direct automatic blanking is accomplished by measuring the absorbance of the test solution 2 seconds after the reactants have been mixed. Our studies show that no appreciable conversion of glucose occurs during this time interval. 3. The results of the new method agree well with the results from the conventional hexokinase assay. In addition, the method requires only 5 microliters of serum, and has a high sample throughput rate.

Autoanalysis↗

Comparison of standardization techniques for colorimetric analyses on a centrifugal analyzer.

The influences of the mode of standardization and the type of standard on the precision of four mechanized methods performed on a centrifugal analyzer are described. Experimental results show that the mode of standardization -- variable, using a standard in each analytical batch, and constant, using a direct relationship between concentration and absorbance -- must be objectively selected. If the variable mode is chosen, the type and level of standard must be carefully chosen and absorbance of assays of the standard must be carefully monitored for good quality control. It is recommended that the optimum standardization technique and standard, where applicable, should be assessed and subsequently documented in evaluations of methods, kits and instruments.

Centrifugation↗