Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMBS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

A preliminary investigation into the development of 3-D printing of prosthetic sockets.

The socket is considered an element of major importance in the makeup of a prosthesis. Each socket is a tailor-made device, designed to fit the unique geometry of the patient's residual limb. The design and manufacture of a prosthetic socket traditionally has been a manual process that relies on the use of plaster of Paris casts to capture the shape of the patient's residual limb and then artisan fabrication techniques to manufacture the socket. Computer-aided design and manufacturing technologies have overcome some of the shortcomings of the traditional process, but the final manufacture of the prosthetic socket is still performed manually. Rapid prototyping (RP), a relatively new class of manufacturing technologies, creates physical models directly from three-dimensional (3-D) computer data. Previous research into the application of RP systems to the manufacture of prosthetic sockets has focused on expensive, high-end technologies that have proven too expensive. This paper investigates the use of a cheaper, low-end RP technology known as 3-D printing. Our investigation was an initial approach to using a technology that is normally associated with producing prototypes quickly, some of which could not be manufactured by alternative means. Under normal circumstances, these printed components are weak and relatively fragile. However, comfortable prosthetic sockets manufactured with 3-D printing have been used in preliminary fittings with patients.

Amputation Stumps↗

Immunohistochemical study of clinical skin-penetrating titanium implants for orthopaedic prostheses compared with implants in the craniofacial area.

The technique of using osseointegrated bone-anchored percutaneous titanium implants in the rehabilitation of patients with amputated limbs has recently been introduced at the Brånemark Osseointegration Centre in Göteborg. The new method is based on an implantation technique that is well-established for anchorage of bone-conductive hearing aids and craniofacial prostheses. The soft tissues around skin-penetrating titanium implants used to anchor orthopaedic prostheses were evaluated histochemically using quantitative analyses. The implants had been in clinical use for between 6 to 24 months. The number of inflammatory cells was higher in the area close to the interface than in the area distant from the skin-penetrating site, and higher than in the corresponding controls. The current data was also compared with corresponding data from tissue around skin-penetrating craniofacial implants. The number of inflammatory cells was lower in the orthopaedic samples than in the craniofacial specimens. We conclude that skin-penetration of orthopaedic implants is as safe as when titanium implants are used for craniofacial rehabilitation, which is a clinically well-established procedure.

Adult↗

Better practical evaluation for lower limb amputees.

PURPOSE: To avoid wastage of prostheses and unfair selection methods for prosthetic prescription, we aimed to develop a practical assessment tool for amputees with doubtful potential, using refurbished second hand modular prostheses. METHOD: Thirty-seven primary amputees (33 transfemoral, 4 transtibial; 22 males, 15 females; median age 71 years, range 19-91) were considered to have doubtful potential for prosthetic use, due to single or multiple impairments. Amputees were assessed using custom-made socket and refurbished second-hand modular prostheses. Liability issues were fully covered. RESULTS: Two patients died before completing the assessment. Median duration of assessment was 4 weeks (range 1-31 weeks). Among the 35 amputees who completed the trial, 14 (38%) proceeded to final prosthesis successfully and 21 (58%) decided to abandon the prostheses. The main reasons for prostheses rejection identified by the team were: hip flexion deformity (4); frailty (4); bilateral amputations (4); COAD (6), stroke (4), stump pain (3) and contralateral leg problems (2) CONCLUSION: High prosthetic rejection rate was expected and confirmed in this group (58%), but considerable number did proceed to definitive prosthesis. The method is practical and fair for amputees of doubtful potential, with considerable cost saving.

Adult↗

Effect of physical fitness on prosthetic ambulation in elderly amputees.

OBJECTIVE: To evaluate the physical fitness and prosthetic ambulation ability of high-level (hip disarticulation, transfemoral) lower-limb amputees aged 60 and above, and to investigate the level of fitness required for successful prosthetic ambulation. DESIGN: The test subjects were 49 amputees aged 60 and above. Subjects were permitted to use any necessary ambulatory aids and were asked to walk at their most comfortable walking speed for evaluation of prosthetic ambulation ability. An incremental exercise test was performed to evaluate physical fitness. RESULTS: The average %VO(2max) value for the successful user group was 64.4%, and the average %VO(2max) value for the failed user group was 44.8%, a statistically significant difference (P < 0.01). Of the amputees with %VO(2max) > or =50, 93.7% were in the successful user group. Of the amputees with %VO(2max) <50, only 23.5% were in the successful user group. CONCLUSION: This study showed that the ability to sustain an exercise intensity of > or =50%VO(2max) can be regarded as a guideline value for the level of fitness required for successful prosthetic ambulation in elderly amputees.

Aged↗

Lower limb amputations in Southern Finland in 2000 and trends up to 2001.

OBJECTIVES: To assess the current incidence of major lower limb amputations in Southern Finland and epidemiological trends during the last 17 years. MATERIALS AND METHODS: In a retrospective survey for the year 2000 patient data was gathered from hospital records in the eight surgical hospitals in the area studied. Follow-up was 1 year. Amputation data for years 1984-1995 was gathered from reports done before at the same area and amputation figures for years 1990-2001 also from the National Research and Development Centre for Welfare and Health. RESULTS: In year 2000, the incidence of major amputations was 154/million inhabitants. The reason for major amputation was chronic critical lower limb ischaemia in 71.8% and acute ischaemia in 16.5% of the cases. The below-knee (BK)/above-knee (AK) ratio was 0.76. After 1 year only 48% of the patients were alive. From 1984 to 2000 amputation incidence showed a decrease of 41%. The decline in age-adjusted amputation incidence from 1990 to 2000 was 30% and by 2001 as much as 40%. There was a significant inverse correlation both between incidence of infrainguinal bypass and amputation (r=-0.682, p=0.021) and between infrapopliteal bypass and amputation (r=-0.682, p=0.021). CONCLUSIONS: There was a reduction in the number of amputations in Southern Finland during the past 17 years. This occurred synchronously with the increase in vascular reconstructions. Our data suggests that vascular surgery saves patients from BK-amputations and therefore relative amount of AK-amputations inevitably rises.

Aged↗

Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite.

In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the potential of a selection of electroactive polymers for sensory applications in hand prostheses. Candidate electroactive polymers are reviewed in terms of their relevant advantages and disadvantages, together with their current implementation in related applications. Empirical analysis of one of the most novel electroactive polymers, ionic polymer metal composites (IPMC), was conducted to demonstrate its potential for prosthetic applications. With linear responses within the operating range typical of hand prostheses, bending angles, and bending rates were accurately measured with 4.4+/-2.5 and 4.8+/-3.5% error, respectively, using the IPMC sensors. With these comparable error rates to traditional resistive bend sensors and a wide range of sensitivities and responses, electroactive polymers offer a promising alternative to more traditional sensory approaches. Their potential role in prosthetics is further heightened by their flexible and formable structure, and their ability to act as both sensors and actuators.

Artificial Limbs↗

A long-term review of children with congenital and acquired upper limb deficiency.

A long-term review of 131 children fitted with upper limb prostheses at the Ontario Crippled Children's Centre between 1965 and 1975 is reported. There were 116 children with congenital deficiencies and 15 who had had amputations. Follow-up ranged from 7 to 17 years. A total of 42 children had abandoned their prostheses, 37 of whom had congenital deformities and five were amputees. The level of deficiency was of fundamental importance in determining whether the prosthesis would be accepted; in the forearm, the longer the stump, the more likely it was that the child would discard the prosthesis. Overall, 50 per cent of children fitted over the age of two years abandoned their prostheses compared with only 22 per cent of patients who had been fitted before the age of two years. The highest drop-out rate was at the age of 13 years when the children became more conscious of their cosmetic appearance. Suggestions for reducing the high drop-out rate in the early teens are put forward.

Adolescent↗

[Questionnaire on the satisfaction of persons with lower-limb amputations towards their prosthesis: development and validation].

The satisfaction of persons with lower-limb amputations towards their prosthesis constitutes a critical factor in the use of the prosthesis. In order to evaluate a person's satisfaction, the SAT-PRO, a self-administrated questionnaire was developed. The questionnaire includes 15 items developed on the basis of the most significant criteria used by the person when selecting a technical aid. These criteria were measured using an ordinal categorical four-level scale. The validation of the SAT-PRO was established from a sample consisting of 61 people with below-knee or above-knee amputations, aging from 60 years and older. The internal consistency of the instrument is high (Cronback's alpha coefficient is 0.90) and the test-retest reliability coefficient (0.97) indicates a very good consistency of the questionnaire over time. Simple and multiple correlations were used to evaluate construct validity. The degree of use of the prosthesis and the feelings of depression, amongst the measured variables, are the best indicators of the satisfaction of the amputees toward their prosthesis.

Aged↗

[Traumatic amputation of the lower limb and traumatic hemipelvectomy. Report of 2 cases in children and review of the literature].

Traumatic hemipelvectomy is rarely observed, mostly because very few patients survive the initial trauma. We describe 2 cases of children who survived this trauma. The first was a 12 year-old boy who accidentally fell between a metro train and the platform. He had a severe open trauma of the pelvis with important hemorrhage. After a first operation to stop hemorrhage and do a cystotomy and a colostomy, ischemia of the lower limb led to an inter-ilio-abdominal amputation. Two months were necessary to heal this. A prosthesis was made 12 months after the accident, postponed by urinary problems. The boy also had a traumatic amputation of the left arm and an upper metaphyseal fracture of the humerus. The second case was that of an 8 year-old girl who suffered a complete traumatic amputation of the hemipelvis after a road accident. A secondary colostomy was performed because of a local infection. Once healing was achieved, the child was low to follow-up. In the literature, we found 36 survivors to this dreadful lesion (4 of them children). We analysed the different problems for the treatment of this trauma caused, and their short term consequences. An early evaluation of the lesions, rapid and intensive resuscitation, early decision to complete the traumatic amputation if necessary, with urinary and digestive derivation, are important elements towards eventual successful outcome of the treatment.

Amputation, Traumatic↗

Prostheses for persons with lower-limb amputations: an extra joint increases range of motion.

This report describes two cases in which the addition of an extra joint enhanced range of motion and improved function in persons with unilateral lower-limb amputation. Both individuals had significant disability in the workplace and at home before this modification. In the first case, an individual with a hemipelvectomy had inadequate hip-joint flexion for maneuvering during photo shoots. In the second case, the individual's transfemoral prosthesis provided insufficient knee flexion for kneeling and working in tight spaces. In each case, a manual-locking, single-axis knee joint was added adjacent to the joint with the limited range of motion. In both cases, the addition of the second joint provided the increased flexibility needed. The first person's hip-flexion range improved from 125 degrees to 190 degrees, and the second person's knee-flexion range improved from 140 degrees to 170 degrees. In repeated follow-up, both patients remained highly satisfied with the intervention. The addition of an extra joint is an option that should be considered when inadequate range interferes with function.

Activities of Daily Living↗

Lower-leg inertial properties in transtibial amputees and control subjects and their influence on the swing phase during gait.

OBJECTIVES: To identify the factors that constitute optimal inertial properties for a lower-limb prosthesis. DESIGN: Experimental, controlled; simulation using a subject-specific double-pendulum model based on individual kinematic data and leg inertial properties. Simulation outcomes were compared with gait analysis data. SETTING: A gait laboratory. PARTICIPANTS: Ten transtibial amputees and 10 matched healthy controls. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Inertial properties of the lower leg; kinematics and kinetics of the swing phase; and kinematics of double-pendulum model simulations. RESULTS: In all amputees, inertial properties were reduced. No between-group differences existed in kinematics; hip and knee joint torques and powers were reduced in the amputees. Deviations between the double-pendulum model and experimental data were larger in the amputees than in the control subjects. CONCLUSIONS: Although current lightweight prostheses have less optimal pendular behavior, their light weight requires smaller joint torques to influence the pendular trajectory. Therefore, optimal inertial properties, in terms of swing phase kinematics and kinetics, will be a compromise between pendular properties and efficient control.

Adult↗

A functional evaluation of prosthetic foot kinematics during lower-limb amputee gait.

This paper reports on a functional evaluation of prosthetic feet based on gait analysis. The aim is to analyse prosthetic feet behaviour under loads applied during gait in order to quantify user benefits for each foot. Ten traumatic amputees (six trans-tibial and four trans-femoral) were tested using their own prosthetic foot. An original protocol is presented to calculate the forefoot kinematics together with the overall body kinematics and ground reaction forces during gait. In this work, sagittal motion of the prosthetic ankle and the forefoot, time-distance parameters and ground reaction forces were examined. It is shown that an analysis of not only trans-tibial but also trans-femoral amputees provides an insight in the performance of prosthetic feet. Symmetry and prosthetic propulsive force were proved to be mainly dependant on amputation level. In contrast, the flexion of the prosthetic forefoot and several time-distance parameters are highly influenced by foot design. Correlations show influential of foot and ankle kinematics on other parameters. These results suggest that prosthetic foot efficiency depends simultaneously on foot design and gait style. The evaluation, proposed in this article, associated to clinical examination should help to achieve the best prosthetic foot match to a patient.

Adult↗

Gait patterns of transtibial amputee patients walking indoors barefoot.

OBJECTIVE: To evaluate the gait patterns of lower limb amputee patients walking with and without shoes and to identify differences in barefoot gait patterns when using different prosthetic feet. DESIGN: Optoelectronic three-dimensional motion analysis of gait was performed on six transtibial amputees using a solid ankle cushion heel foot and a single-axis foot, both with and without shoes. RESULTS: Gait abnormalities were observed during barefoot walking when the solid ankle cushion heel foot was used. These included knee joint hyperextension of 9.9 +/- 2.0 degrees and the loss of ankle plantar flexion in the early stance phase. When the single-axis foot was used, knee flexion thrust declined from 9.9 +/- 3.7 degrees to 7.2 +/- 3.8 degrees and ankle plantar flexion decreased from 9.9 +/- 2.8 degrees to 7.0 +/- 2.1 degrees during the early stance phase. CONCLUSIONS: In transtibial amputees, significant gait abnormalities were observed during barefoot walking using the solid ankle cushion heel foot. These gait patterns improved, however, with use of a single-axis prosthetic foot, which permits a further plantar flexion after the initial contact.

Adult↗

Lower limb intersegmental forces for below-knee amputee children during standing.

The purpose of this investigation was to compare intersegmental knee and hip forces for below-knee amputee (BKA) and able-bodied children during standing. Three unilateral BKA children and 10 able-bodied children (7-9 years) were tested on four separate occasions at six month intervals. Three trials of external force and spatial data during standing were collected from each subject for each session. These data were utilised to determine the intersegmental forces at the knees and hips of the children using a static force analysis. Results indicated that in some instances the intersegmental forces for the BKA children were significantly greater than those of the able-bodied children and in other instances significantly lower (p less than 0.05). In all cases, however, the values were substantially less than corresponding values for walking and running. The effects of the forces upon spatial orientations indicated significant differences between the two groups of children. The frontal plane prosthetic knee angle, the sagittal plane prosthetic and non-prosthetic knee angles, and the sagittal plane trunk angle were all greater for the BKA children when compared to able-bodied children. These differences may be the result of the anatomical structure of the amputee and/or the construction of the prosthesis.

Amputation, Surgical↗

Predicting the use of prostheses by vascular amputees.

OBJECTIVE: To evaluate our accuracy in predicting the use of prostheses by patients undergoing major lower limb amputation. DESIGN: Prospective study, with multiple assessors, "blind" to the predictions made by each other. MATERIALS: Sixty-one patients (35 male: age 51-91, median 79) having their first major lower limb amputation. METHODS: Five members of the rehabilitation team (surgeon, specialist in prosthetics, nurse, physiotherapist and occupational therapist) each recorded predictions of prosthetic use and mobility before amputation and during the first 2 weeks thereafter. Patients were followed up 6-24 months later. RESULTS: At follow-up 17 patients had died. Of the remaining 44 (25 below-knee and 19 above-knee amputees), 23 of 27 (85%) who had been predicted as using prostheses were doing so, while only 11 of 17 (65%) had been correctly predicted as non-users. Nevertheless, only two of the patients not using prostheses contrary to prediction had ever had prostheses made for them, and both had developed problems with the other leg at a later date. Different members of the rehabilitation team were similar in their ability to predict outcome. CONCLUSIONS: Inappropriate fitting of prostheses can be kept to a minimum by a team approach to rehabilitation, but amputees may defy careful prediction by the development of new medical problems.

Aged↗

Medical problems of amputees.

The initial trauma of a major amputation and the medical disorders secondary to it are being studied at the Biomechanics Laboratory. Problems that arise from amputation and from the replacement of the limb by a prosthetic device are complex but interrelated, and approaches to study on basic, applied and clinical levels must be integrated. Three studies carried on at the Biomechanics Laboratory are described in this paper. In the field of amputation operations, it is believed that certain osteoplastic and myoplastic techniques, along with protection for nerve stumps and measures to provide optimum circulatory conditions, may restore biological and mechanical function to a greater degree than is possible with present procedures. From studies of the expenditure of energy during locomotion with and without assistive devices and during therapeutic exercise, it was found that crutch-walking is metabolically much more costly in energy for the amputee than walking with the suction-socket prosthesis; through these studies, it will be possible to define criteria for maximum work loads for disabled persons. In dermatological studies, although there are still unsolved problems, successful methods of treatment have been developed for certain bacterial and fungus infections, contact dermatitides and disorders resulting from edema.

Amputation, Surgical↗

The effect of semirigid dressings on below-knee amputations.

BACKGROUND AND PURPOSE: The effect of using semirigid dressings (SRDs) on the residual limb of individuals who have had below-knee amputations as a consequence of peripheral vascular disease was investigated, with the primary question being: Does the time to readiness for prosthetic fitting for patients treated with the SRDs differ from that of patients treated with soft dressings? SUBJECTS: Forty patients entered the study and were alternately assigned to one of two groups. Nineteen patients were assigned to the SRD group, and 21 patients were assigned to the soft dressing group. METHODS: The time from surgery to readiness for prosthetic fitting was recorded for each patient. Kaplan-Meier survival curves were generated for each group, and the results were analyzed with the log-rank test. RESULTS: There was a difference between the two curves, and an examination of the curves suggests that the expected time to readiness for prosthetic fitting for patients treated with the SRDs would be less than half that of patients treated with soft dressings. CONCLUSION AND DISCUSSION: The results suggest that a patient may be ready for prosthetic fitting sooner if treated with SRDs instead of soft dressings.

Aged↗

Review of arm motion analyses.

Interest in arm movements has increased tremendously in recent years. This interest has been motivated by different goals: the desire for a more scientific approach to replacement or support of the joints of the upper limb, the need for input to biomechanical computer models, and the clinical interest in comparing normal movements with pathological movements. The availability of commercial marker-tracking systems has facilitated achieving these goals. However, the complex nature of arm movements and the lack of standardized movements raises many challenges. In comparison with gait analysis, few arm motion analyses have been conducted. The purpose of this review is to aid researchers and clinicians interested in conducting an arm motion study in choosing the appropriate methodology. This is accomplished both by describing the methods used in past investigations and by highlighting important findings. Due to the variety of research goals, there is sometimes more than one appropriate method and the choice is left to the reader. Nevertheless, since it is extremely desirable to record and express the data in a standardized way, standardization proposals are described. This review, which focuses on methodology rather than results, addresses the following topics: motivations and tasks studied, tracking methods, the shoulder complex, joint centres and rotation axes, marker positions, coordinate system definitions, terminology and rotations, accuracy, and presentation methods.

Activities of Daily Living↗