Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90Linked to original sources

Evaluation of accuracy of the wash impression technique to rebase and replace the resilient part of a soft-lined denture.

The dimensional inaccuracies that might be introduced during a wash impression technique within a heat-cured acrylic resin tray lined with a silicone resilient denture base material were investigated with the use of an electronic digitizer. Casts were poured from impressions of a machined metal die using a light- and heavy-bodied addition silicone in the soft-lined tray and compared with casts poured from impressions made in a hard-based tray and with the master die itself. The dimensions of the casts poured from the heavy-bodied impression in the soft-lined trays were significantly different from those poured from impressions in the hard-based tray when compared with the metal die. Those produced from the light-bodied material showed no statistically significant dimensional difference.

Acrylic Resins↗

Chemical and physical analysis for the improvement of the dry mounting method for fragile documents.

Paper lamination is a widely used method to consolidate fragile documents. Previous studies have presented a new method of lamination that allows the consolidation of documents before undertaking aqueous treatments. In this method a thin Japanese paper coated with an acrylic resin is applied on the fragile document by means of a heated press. In this work we optimised the preparation of the lamination sheets as well as the working procedures, and we were able to establish that our laboratory-made specimens are chemically stable, easily reversible and permeable to aqueous solutions. The latest property is of particular importance, since it allows a subsequent aqueous deacidification even for fragile documents. The laminated paper documents were further analysed by means of colorimetry and FTIR spectroscopy before and after accelerated ageing as well as by determination of the alkali reserve left on the coated paper, in order to compare our lamination method with other commercially available lamination sheets.

Acrylic Resins↗

Biostereometric quantification of clinical denture tooth wear.

In this study the wear of mandibular acrylic resin teeth opposed by porcelain maxillary teeth arranged in a lingualized occlusal scheme over a period of 3 years was measured. Six edentulous subjects received complete dentures as above and with three baseline markers of amalgam. At yearly intervals casts were made of the mandibular occlusal surfaces, including markers, and plotted by stereophotogrammetry. Volumetric loss of material was quantifiable. Ranges of 0.62-3.33 mm3/mm2 on the left side and 0.71-1.64 mm3/mm2 on the right were recorded. Friedman two-way ANOVA test indicated significant wear on teeth 35, 36, 45 and 46 but not on 34 and 44. A one-sided chewer displayed greater wear on the contralateral side, a finding difficult to explain.

Acrylic Resins↗

Modified direct relining method produces an accurate adaptation of denture.

The purpose of this study was to examine if a modified direct relining method could result in excellent denture adaptation compared to a conventional method. Direct relining was done using heat-polymerized acrylic resin base on a maxillary cast with two times of three seconds of cooling using dichloro-difluoro-methane coolant. Discrepancy between cast and intaglio surface at residual ridge and center of palate was measured at 12 minutes after mixing of resin (Time 0) and at 24 hours or seven days after water immersion (36 degrees C). At Time 0 (with three seconds of cooling), the discrepancy at ridge (0.39 +/- 0.27) and palate (0.66 +/- 0.31) was significantly lower compared to that of control (ridge = 0.93 +/- 0.51; palate = 1.14 +/- 0.13, P < 0.05); and the same observations occurred at 24 hours and seven days too. On intaglio side (with three seconds of cooling), the peak temperature was 5 degrees C lower than that of control and it occurred at a delay of about 60 seconds. Based on the results of this study, we therefore suggested that this delayed and lowered temperature served to improve the adaptability of denture base.

Acrylic Resins↗

Scanning electron microscopy of heart muscle freeze-dried from dimethylsulfoxide for simultaneous demonstration of cell morphology and microvascular function.

Scanning electron microscopy was used to examine cryofracture surfaces of ventricular myocardium from glutaraldehyde fixed rat and rabbit hearts subjected to intravascular injection of polymerizing acrylic resin. This allowed simultaneous observation of morphological features of cardiac muscle cells and the functional state of their associated small blood vessels. Because the resin injected to identify capillaries accessible to flow might be soluble in commonly used tissue dehydrating agents, alternative preparation methods using the cryoprotectants dimethylsulfoxide (DMSO) and glycerol were investigated. Provided a high performance backscattered electron detector and simple environmental cell were used to abolish specimen charging and circumvent potential instrument contamination, immersion in 2.82 M DMSO for 12 hr prior to cryofracture and freeze-drying gave the best results. The SEM appearance of specimens dehydrated in this way differed little from that of specimens prepared by ethanol dehydration and freeze-drying or by acetone dehydration and critical-point drying. Tissue shrinkage was 26.5 +/- 9.4%, comparable to that found after standard methods using solvent dehydration and critical-point drying.

Acetone↗

Repeatability of a specially designed intraoral colorimeter.

A specially modified Minolta CS-100 colorimeter with a DP-101 data processor was designed for intraoral use. To test the repeatability of the results obtained with this specially modified unit, five porcelain and five acrylic resin denture teeth were mounted in a fixed position in front of a fixed mounted meter. Three L*a*b* readings were taken per tooth and mean values were obtained after calibration as a baseline measurement. The readings were repeated on day 3 without recalibration and on day 8 after recalibration. The same-day repeatability showed delta E values < 0.4 in nine of the 10 samples. The day 3 repeatability showed delta E values < 0.4 in only 2 of the 10 samples. The day 8 results, after recalibration, showed delta E values > 0.4 in all of the samples, with a range of 0.57 to 2.75. In vivo testing was performed on five patients with delta E values that ranged from 1.1 to 32.1.

Acrylic Resins↗

Outcome of treatment with implant-retained dental prostheses in patients with Sjögren syndrome.

The purpose of this investigation was to evaluate the outcome of treatment with implant-retained prostheses in patients suffering from Sjögren syndrome. Eight women were included in the study; all had suffered oral symptoms of Sjögren syndrome for many years. Seven patients were edentulous in both arches, and 1 patient was edentulous in the maxilla only. All patients reported poor or very poor comfort levels with their conventional dentures. It was the intention to treat each arch that showed subjective and objective denture problems with a complete fixed prosthesis after placement of 6 implants. In all, 54 Brånemark dental implants were placed in these patients. No implants were lost, but 7 implants in 4 patients were clinically not osseointegrated at the time of the abutment connection procedure. Because of nonosseointegrated implants and lack of jawbone, 3 arches were treated with an implant-retained overdenture. Fixed prostheses were made with a titanium framework of premachined components welded together (Procera) and acrylic resin teeth and flanges. Patients answered a questionnaire regarding their oral function before the onset of treatment and 1 month and 2 years after treatment. An average radiographic bone loss of 0.7 mm from the time of implant placement to 1 year after treatment was observed; additional bone loss of less than 0.6 mm was recorded 4 years after treatment. During the first year of function 2 implants lost osseointegration. No prostheses were lost or remade. Treatment with implant-retained prostheses considerably increased the prosthetic comfort and function of the patients. Two years after prosthetic treatment, only 1 patient indicated poor comfort of the prostheses, while the remaining patients reported good or very good comfort levels.

Acrylic Resins↗

Maintenance requirements of implant-supported fixed prostheses opposed by implant-supported fixed prostheses, natural teeth, or complete dentures: a 5-year retrospective study.

PURPOSE: The purpose of this study was to compare the maintenance requirements of implant-supported fixed prostheses with cantilever arms in edentulous jaws when opposed by fixed prostheses of similar design, by natural teeth, or by complete dentures. MATERIALS AND METHODS: The maintenance requirements for the 5-year follow-up period were obtained by examining the dental records of 37 people. Six were provided with fixed prostheses in both arches, 22 with a fixed prosthesis in the mandible opposed by a complete denture, and 9 with a fixed prosthesis opposed by natural teeth. Everyone was treated with Nobel Biocare implants using standard implant and prosthetic protocols. RESULTS: The denture teeth and acrylic resin were repaired on 44 occasions in the group with implants in both jaws, on 14 occasions in the group with implants opposed by natural teeth, and twice in the group in which the implants were opposed by a complete denture. The group with implants in both jaws was more likely to fracture the gold-alloy framework, which occurred on six occasions. The group with implants in both jaws was significantly different from the other two groups in relation to higher incidence of fracture of the teeth and gold-alloy framework. CONCLUSION: The maintenance requirements of implant-supported fixed prostheses with cantilever arms opposed by fixed prostheses of similar design were much greater than when opposed by natural teeth or complete dentures.

Acrylic Resins↗

Improved fit of maxillary complete dentures processed on high expansion stone casts.

PURPOSE: Although relatively well-fitting dentures are produced at low cost and with easy-to-manipulate material, current denture base materials are not ideal. Because acrylic resin complete and removable partial dentures change dimensionally as a result of polymerization and thermal contractions, a high expansion stone was tested in this study to determine its ability to compensate for some of the dimensional change. MATERIAL AND METHODS: Maxillary complete dentures were processed on type III dental stone and high expansion stone casts. The accuracy of fit along the posterior palatal border was measured and compared after the prostheses were trimmed and polished and after their immersion in water at 23 degrees C at 1-day and 1-week intervals. RESULTS: Statistical analysis of the data revealed that at every measurement interval the maxillary complete dentures processed on high expansion stone had posterior palatal border openings that were significantly smaller when compared with type III dental stone (p < 0.001).

Acrylic Resins↗

Preparation and evaluation of Eudragit gels. IV: Rectal gel preparations for sustained release and avoidance of first-pass metabolism of propentofylline.

Formulations of a high-viscosity acrylic resin gel (Eudispert hv) containing propentofylline, a new cerebral microcirculation-improving agent, were prepared and tested for avoidance of the first-pass metabolism of propentofylline through the liver and for sustained release of propentofylline. The absolute bioavailability of propentofylline after oral administration was only 4% in rabbits. The relative bioavailabilities of propentofylline from polyethylene glycol (M(r), 2000) and Witepsol H-15 suppositories were approximately 8- and 16-fold, respectively, compared with oral administration. Furthermore, the absolute bioavailability of propentofylline from Eudispert hv hydrogel and xerogel preparations was approximately 100%. The results indicate that, in principle, drug loss caused by first-pass metabolism may be avoided completely by placing Eudispert hv hydrogel and xerogel formulations in the lower part of the rectum for long periods.

Acrylic Resins↗

In vitro analysis of distraction osteogenesis.

Distraction osteogenesis has been widely used for lengthening craniomaxillofacial bone. The healing process of distracted bone has been studied mainly by histological observation in vivo. To analyze the cellular response to the mechanical stress of distraction, we have established and evaluated an in vitro model of distraction osteogenesis using an organ culture technique. Five-week-old male Wistar rats were used for the experiments. The tibial bone was fractured by hand and fixed for 1 week by acrylic resin. After the initial healing period, the tibial bone was harvested and used for this study. A distraction instrument was devised to control the strain on the cultured bone using a micrometer. After distraction, the samples were histologically evaluated for ossification by hematoxylin and eosin stain and Alcian blue stain. As a result, the histological finding for the bone region at a slow rate of distraction (0.5 mm/day) was different from that at a rapid rate of distraction (1.0 mm/day). The proliferation of cartilage was inhibited at the rapid distraction rate. Thus, we hypothesized that mechanical stress regulated cartilaginous growth in tissue cultivation. Judging from this experiment, the model was useful for investigation of the mechanism of bone formation in distraction osteogenesis, because it was simple and served to isolate many factors.

Acrylic Resins↗

The simulation and calculation of the fatigue of the lower complete denture in function by means of the finite element analysis.

This paper presents a finite element analysis, by which the stress distribution during function of a lower jaw acrylic-resin complete denture can be shown. The geometry of a prosthesis has been approximated by measuring, its elementary dimensions, as well as the dimensions of the characteristic cross-sections, on an already completed denture. Based upon these dimensions a mesh, (a three-dimensional network diagram) of finite elements was made. The results obtained are presented both graphically and numerically. The equivalent fatigue stresses, according to von Mises' energetic theory of firmness, expressed in MPa (or in N/mm2), are also shown. The results obtained enable us to gain an insight into lower complete denture fatigue, and could also be used when optimizing the shape of a denture. Furthermore, they could indicate possible causes of the fatigue fractures of a denture, particularly in the area between the left and the right canines.

Acrylic Resins↗

The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures.

STATEMENT OF PROBLEM: Forces may arise in association with the use of implant stabilized mandibular fixed partial dentures as a result of functional jaw deformation, yet the phenomenon has received little attention and is rarely included as a variable when investigating implant biomechanics. PURPOSE: This in vitro investigation tested the hypothesis that functional mandibular deformation influences force distribution in the jaw/implant/superstructure complex. MATERIAL AND METHODS: Six Brånemark implants were mounted in an acrylic resin replica of an edentulous human mandible. Applied forces were measured with 4-element resistance strain gauges mounted on each of 6 standard titanium abutments. The mandible was supported either on its lower border or suspended in a frame that simulated the natural situation. A cast gold superstructure was a mounted on varying combinations of implants, loaded occlusally in different locations, and the resultant forces at each supporting transmucosal abutment measured. RESULTS: The suspended ("natural") support configuration was associated with considerable differences in patterns of force transmission as compared with bench support. Loads were more widely spread, and large extrusion forces were detected, particularly where several implants were connected. CONCLUSIONS: Functional mandibular deformation is a significant factor in the design of mandibular implant stabilized prostheses, and calls into doubt the value of modeling techniques that do not allow for this phenomenon.

Acrylic Resins↗

Design and evaluation of a controlled-release theophylline tablet. Preliminary communication.

A 300 mg controlled-release theophylline formulation was developed as a tablet prepared by wet granulation using the acrylic resins Eudragit S 100R and Eudragit RSPMR. The tablet was compared with a marketed controlled-release capsule using in vivo and in vitro tests. The in vitro dissolution of theophylline from the tablets followed an apparent zero order kinetics. The in vivo comparison was performed in a cross over fashion in four healthy volunteers who received one tablet or capsule every 12 hours during seven days. The results showed no statistically significant differences in AUC, tmax and in plasma theophylline concentrations at the different times. Nevertheless, concentrations were lower after the administration of the tablets than when the volunteers received the capsules. On the other hand, the apparent elimination half lives obtained after the tablets were longer than with the capsules. An excessive retardation in the release of theophylline from the tablet could be responsible for this fact.

Acrylic Resins↗

Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature.

OBJECTIVES: The roughness of intraoral hard surfaces can influence bacterial plague retention. The present review evaluates the initial surface roughness of several intraoral hard materials, as well as changes in this surface roughness as a consequence of different treatment modalities. METHODS: Articles found through Medline searches were included in this review if they met the following criteria: 1) stated threshold surface roughness values and reputed change in surface roughness due to different manipulation techniques; or 2) included standardized surface conditions that could be compared to the treated surface. RESULTS: Recently, some in vivo studies suggested a threshold surface roughness for bacterial retention (Ra = 0.2 micron) below which no further reduction in bacterial accumulation could be expected. An increase in surface roughness above this threshold roughness, however, resulted in a simultaneous increase in plaque accumulation, thereby increasing the risk for both caries and periodontal inflammation. The initial surface roughness of different dental materials (e.g., teeth, abutments, gold, amalgam, acrylic resin, resin composite, glass ionomer or compomer and ceramics) and the effect of different treatment modalities (e.g., polishing, scaling, brushing, condensing, glazing or finishing) on this initial surface roughness were analyzed and compared to the threshold surface roughness of 0.2 micron. The microbiological effects of these treatment modalities, if reported, are also discussed and compared to recent in vivo data. SIGNIFICANCE: Based on this review, the range in surface roughness of different intraoral hard surfaces was found to be wide, and the impact of dental treatments on the surface roughness is material-dependent. Some clinical techniques result in a very smooth surface (compressing of composites against matrices), whereas others made the surface rather rough (application of hand instruments on gold). These findings indicated that every dental material needs its own treatment modality in order to obtain and maintain a surface as smooth as possible.

Acrylic Resins↗

An investigation on heat transfer to the implant-bone interface due to abutment preparation with high-speed cutting instruments.

Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with medium- and extra-fine-grain diamond and tungsten burs in a high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium-alloy cylindrical implant embedded in an acrylic-resin mandible in a 37 degrees C water bath were reduced horizontally and vertically. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Thirty seconds of continuous cutting with standard turbine coolant caused a mean temperature increase of 1 degrees C with a maximum of 2 degrees C. Similar tungsten cutting caused a mean increase of 2 degrees C with a maximum of 4.7 degrees C, significantly higher than diamond reduction. Additional air-water spray for continuous tungsten cutting had no significant effect, while intermittent cutting for 15-second increments reduced the temperature increase by 75%. Thus, abutment reduction with medium-grit diamonds using intermittent pressure and normal turbine coolant is unlikely to cause an interface-temperature increase sufficient to cause irreversible bone damage and compromise osseointegration.

Acrylic Resins↗

Clinical study of location and reproducibility of three mandibular positions in relation to body posture and muscle function.

Clinical studies have confirmed the adequate reproducibility of both centric occlusion and centric relation when used as reference positions during treatment; however, the reproducibility of the neuromuscular position has been found inadequate. This study evaluated the location and reproducibility of these three mandibular positions in relation to body posture, sitting and supine, and bilateral muscle activity before and after the insertion of a flat mandibular positioning device equilibrated to balance the muscle functions, as shown by two electromyography biofeedback instruments. Intraoral recordings were made in 11 young subjects with complete natural dentition. Acrylic resin clutches that supported a screw point in the maxillary arch and painted glass in the mandibular arch were used and positioned not to interfere with the occlusion. The distances of the screw scratch from two of the edges of the painted glass were used to measure the anteroposterior and mediolateral locations with a micrometer. The reproducibility was evaluated by measuring the scratch surface by measuring the weight of the print cutouts made from photographs of the scratches taken with a stereoscope. The location and reproducibility of centric occlusion and centric relation were not affected by body posture. A more precise posterior neuromuscular position was obtained in the supine position. The insertion of a mandibular positioning device did not affect centric occlusion but gave a more precise centric relation. Neuromuscular position became as precise as centric occlusion and was located anteroposteriorly between centric occlusion and centric relation.

Acrylic Resins↗

The comparative effect of ultrasonic scalers on titanium surfaces: an in vitro study.

BACKGROUND: Professional maintenance is as important for patients with dental implants as it is for patients with natural teeth. However, no proper maintenance instruments have been available for implant patients. The purpose of this in vitro study was to compare the effects of a new ultrasonic scaler (VR), a conventional ultrasonic scaler (SP), and a plastic scaler (PS) on titanium surfaces. METHODS: To simulate subgingival conditions, the implant healing abutments were connected to acrylic resin blocks with artificial gingiva using silicon impression material. The abutments were painted with ink as an artificial form of debris. The ink was removed with the VR, SP, or PS scaler for 60 seconds under standardized conditions, and the removal rate was calculated. The roughness of the abutment surface was measured with a profilometer and observed by scanning electron microscopy (SEM). RESULTS: The removal rate using the VR and SP scalers was higher than that using the PS scaler. No significant differences in the surface roughness or SEM observations were found among the VR, SP, or PS scalers. CONCLUSIONS: In this preliminary study, the new ultrasonic scaler and conventional ultrasonic scaler were shown to be useful for removing artificial debris and produced no significant damage to titanium surfaces compared to plastic scalers. We concluded that new and conventional ultrasonic scalers with a non-metal tip would be suitable for implant maintenance.

Acrylic Resins↗