Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Tracking of a bronchoscope using epipolar geometry analysis and intensity-based image registration of real and virtual endoscopic images.

This paper describes a method for tracking the camera motion of a flexible endoscope, in particular a bronchoscope, using epipolar geometry analysis and intensity-based image registration. The method proposed here does not use a positional sensor attached to the endoscope. Instead, it tracks camera motion using real endoscopic (RE) video images obtained at the time of the procedure and X-ray CT images acquired before the endoscopic examination. A virtual endoscope system (VES) is used for generating virtual endoscopic (VE) images. The basic idea of this tracking method is to find the viewpoint and view direction of the VES that maximizes a similarity measure between the VE and RE images. To assist the parameter search process, camera motion is also computed directly from epipolar geometry analysis of the RE video images. The complete method consists of two steps: (a) rough estimation using epipolar geometry analysis and (b) precise estimation using intensity-based image registration. In the rough registration process, the method computes camera motion from optical flow patterns between two consecutive RE video image frames using epipolar geometry analysis. In the image registration stage, we search for the VES viewing parameters that generate the VE image that is most similar to the current RE image. The correlation coefficient and the mean square intensity difference are used for measuring image similarity. The result obtained in the rough estimation process is used for restricting the parameter search area. We applied the method to bronchoscopic video image data from three patients who had chest CT images. The method successfully tracked camera motion for about 600 consecutive frames in the best case. Visual inspection suggests that the tracking is sufficiently accurate for clinical use. Tracking results obtained by performing the method without the epipolar geometry analysis step were substantially worse. Although the method required about 20 s to process one frame, the results demonstrate the potential of image-based tracking for use in an endoscope navigation system.

Algorithms↗

Statistical and heuristic image noise extraction (SHINE): a new method for processing Poisson noise in scintigraphic images.

Poisson noise is one of the factors degrading scintigraphic images, especially at low count level, due to the statistical nature of photon detection. We have developed an original procedure, named statistical and heuristic image noise extraction (SHINE), to reduce the Poisson noise contained in the scintigraphic images, preserving the resolution, the contrast and the texture. The SHINE procedure consists in dividing the image into 4 x 4 blocks and performing a correspondence analysis on these blocks. Each block is then reconstructed using its own significant factors which are selected using an original statistical variance test. The SHINE procedure has been validated using a line numerical phantom and a hot spots and cold spots real phantom. The reference images are the noise-free simulated images for the numerical phantom and an extremely high counts image for the real phantom. The SHINE procedure has then been applied to the Jaszczak phantom and clinical data including planar bone scintigraphy, planar Sestamibi scintigraphy and Tl-201 myocardial SPECT. The SHINE procedure reduces the mean normalized error between the noisy images and the corresponding reference images. This reduction is constant and does not change with the count level. The SNR in a SHINE processed image is close to that of the corresponding raw image with twice the number of counts. The visual results with the Jaszczak phantom SPECT have shown that SHINE preserves the contrast and the resolution of the slices well. Clinical examples have shown no visual difference between the SHINE images and the corresponding raw images obtained with twice the acquisition duration. SHINE is an entirely automatic procedure which enables halving the acquisition time or the injected dose in scintigraphic acquisitions. It can be applied to all scintigraphic images, including PET data, and to all low-count photon images.

Algorithms↗

Evaluation of image quality of lumbar spine images: a comparison between FFE and VGA.

PURPOSE: The aim of the present study is to compare two different methods for evaluation of the quality of clinical X-ray images. METHODS: Based on fifteen lumbar spine radiographs, two new sets of images were created. A hybrid image set was created by adding two distributions of artificial lesions to each original image. The image quality parameters spatial resolution and noise were manipulated and a total of 210 hybrid images were created. A set of 105 disease-free images was created by applying the same combinations of spatial resolution and noise to the original images. The hybrid images were evaluated with the free-response forced error experiment (FFE) and the normal images with visual grading analysis (VGA) by nine experienced radiologists. RESULTS: In the VGA study, images with low noise were preferred over images with higher noise levels. The alteration of the MTF had a limited influence on the VGA score. For the FFE study, the visibility of the lesions was independent of the sharpness and the noise level. No correlation was found between the two image quality measures. CONCLUSIONS: FFE is a precise method for evaluation of image quality, but the results are only valid for the type of lesion used in the study, whereas VGA is a more general method for clinical image quality assessment. The results of the FFE study indicate that there might be a potential to lower the dose levels in lumbar spine radiography without losing important diagnostic information.

Calibration↗

Localizing prostate cancer in the presence of postbiopsy changes on MR images: role of proton MR spectroscopic imaging.

PURPOSE: To assess whether magnetic resonance (MR) spectroscopic imaging with MR imaging can improve prostate cancer localization in postbiopsy hemorrhage cases. MATERIALS AND METHODS: Records of 175 patients with prostate cancer were retrospectively reviewed; 42 patients (135 hemorrhagic sites) had spatially correlated biopsy data. Patients underwent both phased-array coil-endorectal coil MR imaging and three-dimensional MR spectroscopic imaging within 180 days after transrectal ultrasound (US)-guided biopsy. High-signal-intensity hemorrhage on T1-weighted images and corresponding high- or low-signal-intensity areas on T2-weighted images and the metabolic ratio (choline + creatine)/citrate were recorded. Cancer was identified as a low-signal-intensity area at T2-weighted MR imaging or a metabolite ratio greater than 3 standard deviations above normal at MR spectroscopic imaging. MR imaging, spectroscopic, and biopsy findings were compared. RESULTS: Forty-nine patients had postbiopsy hemorrhage. On T2-weighted images, a higher (P < .01) percentage of hemorrhagic sites demonstrated low signal intensity (80% [108 of 135 sites]), which is similar to the signal intensity seen with cancer. The addition of MR spectroscopic imaging to MR imaging resulted in a significant increase (P < .01) in the accuracy (52% to 75%) and specificity (26% to 66%) of tumor detection. CONCLUSION: The addition of MR spectroscopic imaging to MR imaging significantly improves the ability to determine the presence of prostate cancer and spatial extent when postbiopsy changes hinder interpretation with MR imaging alone.

Aged↗

Extrahepatic abdominal imaging in patients with malignancy: comparison of MR imaging and helical CT in 164 patients.

The purpose of this study was to compare the performance of magnetic resonance (MR) imaging using currently available techniques with contrast-enhanced single-phase helical computed tomography (CT) in depicting extrahepatic disease in patients with malignancy. At two institutions, 164 patients with known or suspected malignancy underwent abdominal imaging with contrast-enhanced helical CT and MR imaging. The prospective interpretations of the CT scans and MR examinations were used to assess the sensitivity of each imaging test in detecting benign and malignant extrahepatic disease at 17 anatomic sites. Imaging findings were compared with results of surgery in 57 patients and with the combined results of image-guided biopsy, follow-up cross-sectional imaging studies, other concurrent imaging tests, and clinical follow-up. For the 164 patients, helical CT scans depicted 221 of 316 (70%) sites of proven extrahepatic tumor compared with 288 sites (91%) (P < 0.0001) for MR imaging. For the 57 patients who underwent exploratory laparotomy, helical CT scans depicted 101 of 154 (66%) findings of surgically confirmed extrahepatic tumor compared with MR imaging, which depicted 139 sites (90%) (P < 0.0001). Anatomic sites at which MR imaging showed a significantly greater detection of extrahepatic tumor included the peritoneum, bowel, and vascular and osseous structures. For depiction of benign extrahepatic disease, there was no significant difference between helical CT and MR imaging. MR imaging, using currently available T1-weighted, RARE T2-weighted, and gadolinium-enhanced imaging, is effective in depicting extrahepatic disease in patients with malignancy. Compared with single-phase helical CT scanning, MR imaging shows an advantage in depicting tumor involving the peritoneum, omentum, bowel, and osseous and vascular structures.

Abdominal Neoplasms↗

MRI of the uterus, uterine cervix, and vagina: diagnostic performance of dynamic contrast-enhanced fast multiplanar gradient-echo imaging in comparison with fast spin-echo T2-weighted pulse imaging.

The aim of this study was to compare the diagnostic performance of contrast-enhanced fast multiplanar gradient-echo (GRE) and T2-weighted fast spin-echo (FSE) image sets in the assessment of uterus, cervix, and vagina. Fast (up to 20 contiguous sections in 23 s) multiplanar GRE and FSE images of 45 patients referred for imaging of the female pelvis were evaluated retrospectively with regard to overall image quality and the ability to detect normal anatomic structures, as well as lesion conspicuity. Results were compared with histologic findings (n = 29) or clinical follow-up. Furthermore, a quantitative assessment of contrast-to-noise ratios among normal uterine and cervical structures as well as uterine lesions was performed for both sequences. On GRE images, uterine and cervical differentiation was best seen on the image sets acquired 15 and 60 s following contrast enhancement and results were significantly better compared with delayed images (p < 0.05). Delineation of the junctional zone was significantly (p < 0.05) better on FSE compared with GRE images; no significant difference was seen for the other anatomic structures. Overall image quality of GRE and FSE images was similar. Sensitivity for lesion detection based on both GRE and FSE images was 96% with a sensitivity of 93% for GRE, and 81% for FSE images alone, respectively. Using the extended McNemar chi 2 test, the difference in diagnostic performance between FSE and GRE revealed no significant difference, whereas the combination of both techniques performed better than FSE imaging alone (p < 0.05). The presented data suggest that dynamic contrast-enhanced GRE imaging should be part of an MR examination of the female pelvis. Combined GRE and FSE imaging provide an excellent sensitivity in the assessment of uterine and vaginal pathologies.

Adolescent↗

Evaluation of the image quality of temporal subtraction images produced automatically in a PACS environment.

The aim of the study is to evaluate the reliable production of temporal subtraction images in a picture archiving and communication system environment and to establish objective criteria for the evaluation of image quality. A total of 117 temporal subtraction chest images (55 in the upright position, 62 in the supine position) were obtained in five consecutive days. In all of these, we confirmed that there were no interval changes on the original images, and cases with diffuse lung disease were excluded. The temporal subtraction images were classified by three chest radiologists into five levels: 5, excellent; 4, good; 3, acceptable; 2, poor; and 1, very poor. The following were examined: (1) the yield of adequate quality of the temporal subtraction images; (2) whether the temporal subtraction images were obtained in the warping or nonwarping mode; and (3) the correlation of the overall subjective image quality with the relative shift angles, relative shift distances, and the standard deviation of gray levels in the temporal subtraction images. The percentages of acceptable temporal subtraction images were 100% and 66% in the upright and supine positions, respectively. Sixteen (26%) of the 62 supine-position images were made in nonwarping mode, whereas all upright images were made in warping mode. Significant correlations were obtained in the relative shift angle (P < 0.05), relative horizontal shift distance (P < 0.05), and standard deviation of gray levels (P < 0.0001). Temporal subtraction images with acceptable image quality were obtained in the upright position. The objective criteria may be useful for the evaluation of image quality.

Humans↗

The cumulative verification image analysis tool for offline evaluation of portal images.

PURPOSE: Daily portal images acquired using electronic portal imaging devices contain important information about the setup variation of the individual patient. The data can be used to evaluate the treatment and to derive correction for the individual patient. The large volume of images also require software tools for efficient analysis. This article describes the approach of cumulative verification image analysis (CVIA) specifically designed as an offline tool to extract quantitative information from daily portal images. METHODS AND MATERIALS: The user interface, image and graphics display, and algorithms of the CVIA tool have been implemented in ANSCI C using the X Window graphics standards. The tool consists of three major components: (a) definition of treatment geometry and anatomical information; (b) registration of portal images with a reference image to determine setup variation; and (c) quantitative analysis of all setup variation measurements. The CVIA tool is not automated. User interaction is required and preferred. Successful alignment of anatomies on portal images at present remains mostly dependent on clinical judgment. Predefined templates of block shapes and anatomies are used for image registration to enhance efficiency, taking advantage of the fact that much of the tool's operation is repeated in the analysis of daily portal images. RESULTS: The CVIA tool is portable and has been implemented on workstations with different operating systems. Analysis of 20 sequential daily portal images can be completed in less than 1 h. The temporal information is used to characterize setup variation in terms of its systematic, random and time-dependent components. The cumulative information is used to derive block overlap isofrequency distributions (BOIDs), which quantify the effective coverage of the prescribed treatment area throughout the course of treatment. Finally, a set of software utilities is available to facilitate feedback of the information for treatment plan recalculation and to test various decision strategies for treatment adjustment. CONCLUSIONS: The CVIA tool provides comprehensive analysis of daily images acquired with electronic portal imaging devices. Its offline approach allows characterization of the nature of setup variation for the individual patient that would have been difficult to deduce using only a few daily or weekly portal images. Distribution of the tool will help establish an important database of setup variation from many clinics. The information derived from CVIA can also serve as the foundation to integrate treatment verification, treatment planning, and treatment delivery.

Computer Peripherals↗

Initial patient imaging with an optimised radiotherapy beam for portal imaging.

BACKGROUND AND PURPOSE: To investigate the feasibility and the advantages of a portal-imaging mode on a medical accelerator, consisting of a thin low-Z bremsstrahlung target and a thin Gd2O2S/film detector, for patient imaging. PATIENTS AND METHODS: The international code of practice for high-energy photon dosimetry was used to calibrate dosimetry instruments for the imaging beam produced by 4.75 MeV electrons hitting a 6mm thick aluminium target. Images of the head and neck of a humanoid phantom were taken with a mammography film system and the dose in the phantom was measured with TLDs calibrated for this beam. The first head and neck patient images are compared with conventional images (taken with the treatment beam on a film radiotherapy verification detector). Visibility of structures for six patients was evaluated. RESULTS: Images of the head and neck of a humanoid phantom, taken with both imaging systems showed that the contrast increased dramatically for the new system while the dose required to form an image was less than 10(-2)Gy. The patient images taken with the new and the conventional systems showed that air-tissue interfaces were better defined in the new system image. Anatomical structures, visible on both films, are clearer with the new system. Additionally, bony structures, such as vertebrae, were clearly visible only with the new system. The system under evaluation was significantly better for all features in lateral images and most features in anterior images. CONCLUSIONS: This pilot study of the new portal imaging system showed the image quality is significantly improved.

Head and Neck Neoplasms↗

Dynamic gadolinium-enhanced MR imaging of pituitary adenomas: usefulness of sequential sagittal and coronal plane images.

Dynamic magnetic resonance (MR) imaging for pituitary adenomas is usually performed in a coronal direction; however, small lesions between slices, or lesions located at the anterior or posterior aspect of the pituitary gland might be overlooked on MR images in only the coronal direction. The purpose of our study was to evaluate whether consecutive dynamic MR images in the coronal and sagittal planes improve detection of pituitary adenomas. Eighteen patients with pituitary microadenomas and nine with healthy pituitary glands were included in this study. MR images were performed with 1.5 T superconductive units and commercially-available head coils. After a 5 ml gadolinium contrast injection, eight serial dynamic sagittal images were obtained. Within 3 or 6 min, this was followed by a 10-15 ml gadolinium injection and acquisition of eight serial dynamic coronal images. Dynamic MR images and conventional noncontrast- and contrast-enhanced sagittal and coronal T1-weighted images were evaluated independently in a blind fashion by two neuroradiologists regarding the depiction of pituitary microadenomas. The sensitivities of dynamic enhanced MR imaging in the detection of microadenomas were 61.1% in sagittal direction, 72.2% in coronal direction respectively, and were superior to those of conventional noncontrast- and contrast-enhanced T1-weighted imaging (22.2-50%). The sensitivity of a combination of sagittal and coronal dynamic enhanced MR imaging for the detection of microadenomas was 88.9% and was superior to those of conventional noncontrast- and contrast-enhanced T1-weighted imaging combining sagittal and coronal directions (61.1%, 61.1%) (P<0.05, P<0.05, respectively). The specificity and accuracy of dynamic enhanced MR imaging with combination of sagittal and coronal images was 88.9% respectively. Dynamic gadolinium-enhanced MR imaging, especially using both sagittal and coronal planes, was concluded to be useful for the detection of pituitary microadenomas.

Adenoma↗

Prediction of histopathologic features and proliferative activity of uterine leiomyoma by magnetic resonance imaging prior to GnRH analogue therapy: correlation between T2-weighted images and effect of GnRH analogue.

To predict the histological features and proliferative activity of leiomyomas and to evaluate the effect of GnRH analogues (GnRHa) by MR images, the correlation between MR images and histopathologic findings was studied on 137 leiomyomatous nodules from 79 patients. The correlation among cellularity, proliferative activity and MR images was studied on sections of 42 leiomyomatous, nodules stained with hematoxylin-eosin and immunohistochemistry for proliferating cell nuclear antigen. The utility of MR imaging in assessing response to therapy with a GnRHa (buserelin 900 micrograms/day, intranasal for 16 weeks) was studied on 62 leiomyomatous nodules from 29 patients. On T2-weighted MR images, we encountered five major images. According to the increase of signal intensity relative to that of the myometrium and/or the endometrium, the images were classified as Type 1, Type 2, Type 3, Type 4, and Type 5. Histopathologically, the majority of Type 1, Type 2 and Type 3 images had features of typical leiomyoma. Almost all cellular leiomyomas and bizarre leiomyomas had Type 4 images. Variable degenerative features were observed in the nodules with Type 5 images. According to the increase of signal intensity, leiomyomas had a tendency to show a high degree of both cellularity and proliferative activity. Moreover, the reduction rate of leiomyomatous nodules after GnRHa therapy correlated with the tumor signal intensity on T2-weighted images before therapy. The reduction rate was the lowest in Type 1 images (20.9%) and the highest in Type 4 images (50.7%). These results suggest that increased the signal intensity on T2-weighted MR images correlates with the cellularity and proliferative activity of leiomyomas, and with tumor response to GnRHa treatment. MR imaging enables quantitative monitoring of GnRHa therapy in patients with leiomyomatous nodules, and allows us to predict the histopathology, cellularity, proliferative activity, and shrinkage rate of nodules before GnRHa treatment.

Adult↗

Breast cancer: gadolinium-enhanced MR imaging with a 0.5-T open imager and three-point Dixon technique.

PURPOSE: To investigate the three-point Dixon technique as a method for obtaining fat-nulled images of contrast material-enhancing breast lesions with a 0.5-T open magnetic resonance (MR) imager. MATERIALS AND METHODS: Real and imaginary source images were obtained with an interleaved gradient-echo sequence with a repetition time of 550 msec and echo times of 12.8, 19.8, and 26.8 msec. Twenty-four to 28 sections were obtained in the sagittal plane with a 90 degrees flip angle, 256 x 192 matrix, 3-4.5-mm section thickness, and acquisition time of 10 minutes 54 seconds. A three-point Dixon reconstruction algorithm was used to generate water-specific, fat-specific, and combined images from the raw image data. Twelve breasts in 10 patients and one healthy volunteer were imaged. RESULTS: Three-point Dixon images were superior to extended two-point Dixon and fat-suppressed images and to images generated by means of subtraction of three-dimensional fast spoiled gradient-echo images obtained before contrast material injection from those obtained after. CONCLUSION: Three-point Dixon imaging provides a robust method for creating fat-nulled images of enhancing breast lesions in the 0.5-T open MR environment. Water-specific three-point Dixon images are successful in regions of B0 heterogeneity and are superior to fat-suppressed images. They are much less susceptible to motion artifact than are subtraction images.

Adult↗

Diffusion-weighted MR imaging: diagnostic accuracy in patients imaged within 6 hours of stroke symptom onset.

PURPOSE: To evaluate the diagnostic accuracy of diffusion-weighted magnetic resonance (MR) imaging performed within 6 hours of the onset of stroke symptoms. MATERIALS AND METHODS: The authors reviewed the patient records and images from all patients hospitalized in a 10-month period in whom diffusion-weighted imaging was performed within 6 hours of the onset of strokelike symptoms (n = 22). Analyses included comparison of the initial interpretation of the diffusion-weighted images with the final clinical diagnosis; blinded reviews of computed tomographic (CT) scans and conventional and diffusion-weighted images; and determination of lesion contrast-to-noise ratios (CNRs). RESULTS: Diffusion-weighted images indicated stroke in 14 patients, all of whom had a final diagnosis of acute stroke. Diffusion-weighted images were negative in eight patients, all of whom had a final clinical diagnosis other than stroke (100% sensitivity, 100% specificity, chi 2 = 23.00, P < .0001). Blinded reviews yielded 100% sensitivity and 86% specificity for diffusion-weighted MR imaging (chi 2 = 15.43, P < .0005); 18% sensitivity and 100% specificity for conventional MR imaging (chi 2 = 2.85, P > .2); and 45% sensitivity and 100% specificity for CT (chi 2 = 4.40, P > .10). Lesion percentage CNRs were 77% for diffusion-weighted imaging, 5.5% for CT, 9.8% for T2-weighted MR imaging, and 3.1% for proton-density-weighted MR imaging (P < .002 for diffusion-weighted imaging vs others). CONCLUSION: Diffusion-weighted MR imaging is highly accurate for diagnosing stroke within 6 hours of symptom onset and is superior to CT and conventional MR imaging.

Aged↗

MR imaging in the evaluation of benign uterine masses: value of gadopentetate dimeglumine-enhanced T1-weighted images.

Forty-six patients with surgically proved disease (115 leiomyomas, 19 cases of adenomyosis, and 14 endometrial polyps) were studied to determine if gadopentetate dimeglumine-enhanced T1-weighted MR images improve the detection and characterization of benign tumors of the uterus. Lesion detection and characterization were assessed separately for each sequence (unenhanced T1-weighted, proton-density-weighted, and T2-weighted and contrast-enhanced T1-weighted images) and for combinations of sequences (unenhanced T1- and T2-weighted images, unenhanced and contrast-enhanced T1-weighted images, and unenhanced T1- and T2-weighted and contrast-enhanced T1-weighted images). In the evaluation of leiomyomas, analysis of all three sequences provided the best detection (92%) and characterization (92%), but the improvement, except when compared with unenhanced T1-weighted images alone, was not statistically significant. The use of contrast medium did not contribute to either tumor detection or characterization. In the evaluation of adenomyosis, T2-weighted images provided significantly better lesion detection and characterization than did either unenhanced or contrast-enhanced T1-weighted images. In the evaluation of endometrial polyps, however, contrast-enhanced T1-weighted images provided significantly better lesion detection and characterization than did unenhanced images. With contrast-enhanced images, the detection rate was 79%, compared with 36% for T2-weighted images and 7% for T1-weighted images. Lesion characterization was the best (73%) when all imaging sequences were analyzed. Our study shows that with conventional spin-echo sequences, the use of contrast-enhanced T1-weighted images does not improve the detection or characterization of uterine leiomyomas or adenomyosis but significantly improves the detection of endometrial polyps.

Contrast Media↗

MR imaging of pelvic masses in women: contrast-enhanced vs unenhanced images.

OBJECTIVE: We compared the value of contrast-enhanced MR images with that of T2-weighted MR images in the diagnosis and staging of pelvic masses in women. MATERIALS AND METHODS: The findings on preoperative MR studies of 97 patients with a total of 124 surgically proved lesions were retrospectively analyzed. Unenhanced T1- and T2-weighted spin-echo images were compared with contrast-enhanced T1-weighted images. The final diagnosis included benign (36 patients), borderline (six patients), and malignant (15 patients) ovarian masses, fallopian tube masses (15 patients), endometrial tumors (seven patients), cervical carcinomas (32 patients), subserous leiomyomas (11 patients), and two masses of extragenital origin. RESULTS: In the depiction of pelvic lesions, the sensitivity of contrast-enhanced MR imaging (96%) was equal to that of unenhanced T2-weighted imaging (97%). Contrast-enhanced images were useful in the definition of intratumoral architecture and tumor borders of 72 adnexal masses, resulting in better determination of malignancy (accuracy, 95%) than on T2-weighted images (85%). Size of viable tumor, differentiation of tumor from retained fluid, and depth of myometrial invasion of six endometrial carcinomas were most reliably shown on contrast-enhanced images. In the evaluation of cervical carcinoma, overall staging accuracy of contrast-enhanced imaging (80%) was slightly inferior to that of T2-weighted imaging (83%). However, contrast-enhanced images improved assessment of parametrial and organ invasion in seven cases in which findings on T2-weighted MR images were equivocal. Administration of contrast material was not helpful in the evaluation of subserous leiomyomas or masses of extragenital origin. CONCLUSIONS: The findings suggest that when results of unenhanced T1- and T2-weighted MR imaging of pelvic masses are equivocal, contrast-enhanced MR images should be used as supportive and complementary pulse sequences to (1) improve definition of intratumoral architecture and prediction of malignancy in adnexal tumors, (2) stage endometrial carcinoma, and (3) determine tumor extension in cervical carcinoma.

Adult↗

Detection of knee hyaline cartilage defects using fat-suppressed three-dimensional spoiled gradient-echo MR imaging: comparison with standard MR imaging and correlation with arthroscopy.

OBJECTIVE: A preliminary study was done to prospectively compare fat-suppressed three-dimensional spoiled gradient-echo (3D SPGR) MR imaging with standard MR imaging for detection of defects in the hyaline cartilage of the knee, using arthroscopy as the reference standard. SUBJECTS AND METHODS: We studied 43 consecutive patients referred by two orthopedic surgeons for MR imaging of the knee. Twelve had arthroscopic correlation; they formed the basis of our study. Hyaline cartilage was imaged with a fat-suppressed 3D SPGR sequence with previously determined optimal imaging parameters. Our standard MR imaging study consisted of two-dimensional coronal T1-weighted spin-echo, sagittal dual-echo T2-weighted spin-echo, and axial multiplanar gradient-echo sequences. With arthroscopy as the reference standard, sensitivity and specificity of fat-suppressed 3D SPGR and standard MR images for detecting cartilage tears were determined by articular surface (eight surfaces in each patient: medial and lateral patellar facets, trochlear facets, femoral condyles, and tibial plateaus). Statistically significant differences in sensitivity and specificity were determined. RESULTS: Arthroscopy showed 15 cartilage defects in seven patients. The fat-suppressed 3D SPGR images had higher sensitivity (93%) than the standard MR images (53%, p = .03). Specificity was 94% for the fat-suppressed 3D SPGR images compared with 93% for the standard MR images (p > .05). The five false-positive articular surfaces on fat-suppressed 3D SPGR images were from focal signal change within the substance of the cartilage without a contour defect. Smoothly contoured thinning and loss of the trilaminar appearance of the hyaline cartilage at the lateral femoral notch was shown in all subjects and was considered a normal finding. CONCLUSION: Fat-suppressed 3D SPGR imaging is more sensitive than standard MR imaging for the detection of abnormalities of the hyaline cartilage in the knee. Routine use of this technique may strengthen the role of MR imaging for noninvasive evaluation of internal derangements of the knee.

Adolescent↗

Half-dose gadolinium-enhanced MR imaging with magnetization transfer technique in brain tumors: comparison with conventional contrast-enhanced MR imaging.

OBJECTIVE: The purpose of this study was to determine whether half-dose enhanced MR imaging with magnetization transfer (MT) saturation can replace standard-dose enhanced MR imaging without MT saturation in patients who have brain tumors. SUBJECTS AND METHODS: Three sets of enhanced T1-weighted MR images were prospectively obtained for each of 25 patients with 32 brain tumors; the first conventional MR images without MT were obtained after administration of standard-dose (0.1-mmol/kg) gadopentetate dimeglumine. Within 1 week, patients underwent administration of one half-dose (0.05 mmol/kg) of the contrast medium, and then two sets of enhanced T1-weighted images were obtained with and then without MT. The degree of contrast enhancement was assessed qualitatively for all 32 tumors and quantitatively for 26 tumors. In the quantitative analysis, we compared mean values for tumor-brain contrast-to-noise ratios in three sets of images. RESULTS: The visual conspicuity of enhancing lesions in half-dose T1-weighted MR images with MT was comparable with that of standard-dose conventional T1-weighted MR images in 43% of cases including most extraaxial tumors. In approximately 75% of cases, the degree of enhancement of the lesions was similar for half-dose T1-weighted images obtained with and without MT. Overall, mean values for tumor-brain contrast-to-noise ratios were significantly lower in half-dose T1-weighted images with MT than in standard-dose T1-weighted images. Also, mean values for tumor-brain contrast-to-noise ratios were significantly higher in half-dose T1-weighted images with MT than in half-dose T1-weighted images without MT. CONCLUSION: Because half-dose enhanced MR imaging with MT yields enhancement comparable with that of standard-dose enhanced conventional MR imaging in less than 50% of cases, the former technique would replace the latter in only limited cases such as selected extraaxial tumors.

Adult↗

Mean regional cerebral blood flow images of normal subjects using technetium-99m-HMPAO by automated image registration.

UNLABELLED: The purpose of this study was twofold: to calculate relative uptake values for 99mTc-HMPAO in various regions of the normal brain after alignment and registration to a standard shape and size, and to validate the automated image registration (AIR) program for SPECT-to-SPECT transformation. METHODS: Thirty subjects took part in this study. Technetium-99m-HMPAO brain SPECT and x-ray-CT scans were acquired. SPECT images were normalized to an average activity of 100 counts/pixel. Intersubject accuracy was evaluated on brain images of 17 normal subjects (mean age = 64.9 +/- 8.7 yr). These images were aligned and registered to a standard size and shape with the help of AIR. Realigned images were overlaid on reference images to determine the overlap areas. Intrasubject accuracy was evaluated by realigning 20 degree rotated brain images with an index calculated as: overlap area/(overlap area + nonoverlap area). Anatomical variability between realigned target and reference images was evaluated by measurements on corresponding x-ray-CT scans, realigned using transformations that were established by the SPECT images. Realigned brain SPECT images of 30 normal subjects (mean age = 50.7 +/- 18.7 yr), including those subjects examined in the accuracy validation study, were used to generate mean and s.d. images. Images based on the mean value of each voxel (n = 30) were compared with other mean images prepared by the human brain atlas (HBA) standardization technique on a voxel-by-voxel basis to generate T maps. RESULTS: Accuracy indices were 0.98 +/- 0.006 and 0.99 +/- 0.002 for the intersubject and intrasubject evaluations, respectively. The maximum anatomical variability was 4.7 mm after realignment. Paired Student's t-test comparisons of mean HBA and AIR images revealed statistically significant differences for the deep white matter, pons and occipito-temporal regions. These differences could be explained by variation in the population being studied and the protocol for data handling by AIR and HBA. CONCLUSION: AIR aligns and registers brain SPECT images with acceptable accuracy, without the necessity of MRI or x-ray-CT scans.

Brain↗