Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostic accuracy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Diagnostic accuracy of percent free prostate-specific antigen in prostatic pathology and its usefulness in monitoring prostatic cancer patients.

INTRODUCTION: The aim of our study was to evaluate the clinical usefulness of percent free prostate-specific antigen (PSA) [ratio of free PSA (fPSA) to total PSA (tPSA); f/tPSA] in prostatic pathology and its usefulness in monitoring prostatic cancer patients. PATIENTS AND METHODS: Our prospective study was carried out on 470 consecutive male patients referred to our outpatient urological clinic for observation. We looked for relationships between tPSA, fPSA and percent free PSA and the patient's age, prostatic volume and histologic diagnosis as assessed by prostatic biopsies or surgical specimens (benign prostatic hypertrophy, carcinoma, hypertrophy with inflammation). In all cases, we calculated the specificity, sensitivity and diagnostic accuracy of percent free PSA in the diagnosis of prostatic diseases, using cutoff values ranging from 14 to 20%. In prostatic cancer patients, we considered the relationships between the various PSA molecular forms and staging, grading and follow-up values. We also evaluated the effects of hormonosuppressive therapy on the serum markers and noted for which tPSA value percent free PSA possessed the greatest diagnostic accuracy. RESULTS: While tPSA and fPSA values appeared to be correlated with patient age and prostatic volume, percent free PSA did not show a relationship with these parameters. The specificity, sensitivity and overall diagnostic accuracy were better assuming a 16% cutoff value for percent free PSA than with other cutoff values. Prostatic inflammation associated with benign hypertrophy can cause false positives in both tPSA and f/tPSA measurements, since 60% of these patients have an f/tPSA ratio below 16%. In diagnosing carcinoma, the diagnostic accuracy of percent free PSA is 100% when tPSA is between 2.5 and 4.0 ng/ml. Percent free PSA is not linked with staging in prostatic cancer, but it does appear to be related to the Gleason score. In patients receiving hormonosuppressive treatment, f/tPSA decreased significantly, and more so in patients with a higher Gleason score. In patients with disease in rapid progression, percent free PSA was lower than in patients in a stable condition. CONCLUSIONS: Based on our experience, 16% as the f/tPSA cutoff value for discriminating between benign and malignant pathologies is the best possible choice, as it provides the highest overall values of sensitivity, specificity and diagnostic accuracy (80, 61.5 and 84.5%, respectively) in the diagnosis of prostatic cancer. We believe that f/tPSA is not a definitive test for diagnosing prostatic cancer. Our observations on the behavior of percent free PSA in relation to prostatic carcinoma grading and staging and in the follow-up of carcinoma patients are interesting; however, further studies are needed to define the appropriate role of f/tPSA in patients with an established diagnosis of prostatic carcinoma and in the follow-up of patients with prostatic cancer.

Adult↗

Diagnostic accuracy of 99mTc-sestamibi breast imaging: multicenter trial results.

UNLABELLED: Although mammography is well established as a first-line tool for breast cancer screening and detection, efforts to develop complementary procedures continue. Observation of 99mTc-sestamibi tumor uptake provided the impetus for its evaluation as an adjunctive technique. This trial's objectives were to determine in a multicenter trial the diagnostic accuracy of 99mTc-sestamibi in women with suspected breast cancer and to investigate factors influencing diagnostic accuracy. METHODS: Our multicenter trial enrolled 673 women (387 with nonpalpable abnormalities; 286 with palpable abnormalities) scheduled for excisional biopsy or mastectomy. Blinded and unblinded interpretations of scintigraphic images were compared with core laboratory established histopathologic diagnoses to define the diagnostic accuracy of 99mTc-sestamibi breast imaging. RESULTS: Blinded readers' diagnostic accuracy was 78%-81%. Inter-reader agreement was excellent, ranging from 95% to 100% (kappa = 0.82-0.99). Overall institutional sensitivity and specificity for 99mTc-sestamibi breast imaging were 75.4% and 82.7%, respectively. In this population with a 40.1% disease prevalence, the positive predictive value was 74.5% and the negative predictive value was 83.4%. The negative predictive value was 94% in patients with a 40% or lower mammographic likelihood of breast cancer. Sensitivity was higher for palpable abnormalities; specificity was higher for nonpalpable abnormalities. Sensitivity was decreased for tumors <1 cm in largest dimension but appeared not to be affected by patient's age. CONCLUSION: As an adjunct to current procedures, 99mTc-sestamibi breast imaging may contribute to patient management decisions in selected populations, including women with dense breasts, mammographically indeterminate lesions >1 cm, and palpable abnormalities.

Biopsy↗

Diagnostic accuracy of sonohysterography, transvaginal sonography, and hysterosalpingography in patients with uterine cavity diseases.

OBJECTIVE: To evaluate the diagnostic accuracy of sonohysterography (SHG) in uterine cavity diseases in infertile patients, comparing its results with those of hysterosalpingography (HSG) and transvaginal sonography (TVS). Hysteroscopy was the gold standard. DESIGN: Descriptive, prospective study. SETTING: A tertiary university referral center. PATIENT(S): Sixty-five infertile women 19 to 43 years of age. INTERVENTION(S): Patients underwent SHG, conventional TVS, HSG, and hysteroscopy. MAIN OUTCOME MEASURE(S): The results of each examination were compared with those obtained by the gold standard. The following diagnoses were considered separately: polypoid lesions, uterine malformations, intrauterine adhesions, and endometrial hyperplasia (EH). Sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively), and 95% confidence intervals were calculated. RESULT(S): Sonohysterography had the same diagnostic accuracy as the gold standard for polypoid lesions and EH, with no equivocal diagnosis. Hysterosalpingography showed a sensitivity of 50% and a PPV of 28.6% for polypoid lesions and a sensitivity of 0% for EH. Transvaginal sonography had both sensitivity and PPV of 75% for polypoid lesions and EH. For uterine malformations, SHG had a sensitivity of 77.8%, whereas TVS and HSG both had a sensitivity of 44.4%. Sonohysterography and HSG had a sensitivity of 75% in the detection of intrauterine adhesions and respective PPVs of 42.9% and 50%. Transvaginal sonography showed sensitivity and PPV of 0% for this diagnosis. CONCLUSION(S): Sonohysterography was in general the most accurate test. Its diagnostic accuracy was markedly superior for polypoid lesions and EH, with total agreement with the gold standard. In diagnosis of intrauterine adhesions, SHG had limited accuracy, similar to that obtained by HSG, with a high false-positive diagnosis rate.

Adult↗

Imaging evaluation of blunt renal trauma in children: diagnostic accuracy of intravenous pyelography and ultrasonography.

Forty-six consecutive children with blunt renal injury were evaluated retrospectively to assess the diagnostic accuracy of the different imaging methods, including ultrasonography (US), intravenous pyelography (IVP), and computed tomography (CT), and to determine the optimal radiologic management. Doppler ultrasonography was never performed in an emergency. Classification of the 46 renal injuries was as follows: 25 contusions, 4 lacerations, 11 ruptures, and 6 pedicle injuries. The diagnostic accuracy of IVP (80.8%) was superior to the diagnostic accuracy of US (41%) in all types of renal injuries. IVP should be performed as an emergency procedure when macroscopic hematuria is present, or when an isolated renal injury is clinically suspected. Microscopic hematuria alone is no longer an indication to perform IVP. Asymptomatic patients with microscopic hematuria should have US examination and should be observed with performance of serial urine analyses. Multiply injured and hemodynamically stable children should be evaluated by contrast-enhanced CT. Hemodynamically unstable children should undergo immediate exploratory laparotomy, if it is indicated after assessment by imaging.

Child↗

Logistic discriminant analysis improves diagnostic accuracy of exercise testing for coronary artery disease in women.

BACKGROUND: Diagnostic accuracy of the exercise electrocardiogram in women has been shown to be limited for the detection of coronary artery disease. New diagnostic methods based on computer analysis of the exercise electrocardiogram and multivariate analysis have improved the diagnostic value of exercise testing in male subjects. The aim of the present study was to assess whether the diagnostic value of exercise testing can be enhanced in women by using multivariate analysis of exercise data. METHODS AND RESULTS: Between 1978 and 1984, 135 infarct-free women underwent exercise testing and coronary angiography. Significant coronary artery disease was present in 41% of the patients. In this first group, maximal exercise variables were submitted to a stepwise logistic analysis. Work load, heart rate, and ST60X were selected to build a diagnostic model. The model was tested in a second group of 115 catheterized women (significant coronary artery disease in 47%) and of 76 volunteers. We compared the present model with conventional analysis of the exercise electrocardiogram, with ST changes adjusted for heart rate, and with a previously described analysis. In both groups, sensitivity was better with the present model (66% and 70%) than by conventional (68% and 59%) and by the previously described analysis (57% and 44%) without a loss of specificity (85% and 93%). Receiver-operator characteristic curves showed also a better diagnostic accuracy with the present model. CONCLUSIONS: In women, logistic analysis of exercise variables improves the diagnostic value of exercise testing. It yields a significantly better sensitivity without a loss of specificity.

Coronary Disease↗

The price of better diagnostic accuracy in suspected appendicitis in Jerusalem.

We studied changes in diagnostic accuracy and in perforation rates in cases of suspected appendicitis at two major Jerusalem hospitals. In females, a major improvement in accuracy was observed over the past decade which was not accompanied by higher perforation rates. In males, on the other hand, the reduction in the rate of negative appendectomies was accomplished at the expense of a large increase in perforations. At the end of the decade of observation, diagnostic accuracy in males was still far better than for females, but the perforation rate in males had become worse than the rate for females. We conclude from our work and that of others that at high baseline negative appendectomy rates much improvement is possible without causing higher perforation rates, whereas at relatively low negative appendectomy rates, further decreases will, perforce, cause more perforations, a poor trade-off in the opinion of most investigators.

Adolescent↗

The selected use of ultrasound mammography to improve diagnostic accuracy in carcinoma of the breast.

Our initial experience with diagnostic ultrasound mammography (UM) showed it to be of high diagnostic accuracy and improved specificity when compared with x-ray mammography (XRM) in certain categories of patients. To evaluate this modality further, we reviewed our experience with 600 consecutive patients who underwent ultrasound mammography as part of their initial evaluation for breast disease. Five categories of patients were reviewed: I: age 35 or less--129; II: DY or P-2 pattern on XRM--174; III: negative XRM but symptoms requiring additional evaluation--81; IV: high risk remaining breast in patients previously having mastectomy--48; V: refusal of repeat XRM because of pregnancy, lactation, or fear of radiation exposure--168. Fifty-five solid lesions were diagnosed, including 36 carcinomas. Seventeen of these were not diagnosed on x-ray mammography, giving an improved pick-up of carcinoma in this overall group of 2.83%. Of particular interest was that, of the 27 carcinomas that were found in the group having XRM, 8 or 29.6% were missed on that modality alone. Five of these (62.5%) were patients having a DY pattern. All patients have been followed carefully and re-examined at 3-month intervals, with no evidence of a false negative examination. Overall, we feel diagnostic ultrasound mammography is a valuable adjunct to x-ray mammography and recommend its continued use in selected groups of patients where it has a superior diagnostic accuracy over x-ray mammography alone.

Adolescent↗

High diagnostic accuracy of NT-proBNP for cardiac origin of pleural effusions.

A prospective study was performed to evaluate the diagnostic accuracy of N-terminal-pro-B-type natriuretic peptide (NT-proBNP) levels, measured simultaneously in serum and pleural fluid, in identifying pleural effusions due to heart failure. Pleural fluid and serum samples from all patients presenting for thoracentesis between April 2004 and May 2005 were simultaneously collected. The discriminative properties of NT-proBNP levels in identifying pleural effusions due to heart failure were determined by receiver operating characteristic curve analysis and compared to the diagnostic value of finding a transudate by Light's criteria. Ninety-three patients were evaluated, 27% with cardiac effusion and 73% with exudative effusions of various cause. Levels of NT-proBNP in pleural fluid and serum correlated closely. Serum and pleural fluid NT-proBNP levels were significantly elevated in patients with cardiac effusion. With a cut-off value of 4,000 ng.L(-1), NT-proBNP levels in pleural fluid and serum displayed comparably high diagnostic accuracies of 92 and 91%, respectively. All patients misclassified by Light's criteria were correctly identified by measuring NT-proBNP levels. N-terminal-pro-B-type natriuretic peptide levels in either pleural fluid or serum showed a high diagnostic accuracy compared to traditional criteria. Thus measuring N-terminal-pro-B-type natriuretic peptide is a valuable additional diagnostic tool for the detection or exclusion of cardiac origin of pleural effusions.

Aged↗

Salivary gland fine needle aspiration using the ThinPrep technique: diagnostic accuracy, cytologic artifacts and pitfalls.

OBJECTIVE: To retrospectively assess the diagnostic accuracy, cytologic features and pitfalls of ThinPrep (TP) (Cytyc Corporation, Marlborough, Massachusetts, U.S.A.) versus conventional (smear) preparation (CP) in salivary gland fine needle aspiration biopsies (FNABs) and second, to evaluate the reproducibility of the cytomorphologic criteria used in the evaluation of FNABs prepared by CP versus TP. STUDY DESIGN: All salivary gland fine needle aspiration biopsies (SGFNABs) between January 1996 and June 1999 were retrieved from the cytology files of the University of Michigan Hospital. Histologic correlation was identified when available. Two cytopathologists reevaluated the slides for artifacts, cellular preservation, background material, cellularity, and cytoplasmic and nuclear details. RESULTS: Seventy-four of the 134 (55%) cases identified had histologic follow-up. Fifty (68%) cases were processed by TP and 24 (32%) by CP. FNAB processed by TP and CP correctly identified malignancy in 14 and 9 cases, respectively. There were three (4%) false negative cases. These included two acinic cell carcinomas and one mucoepidermoid carcinoma. There were 37 true negative cases (24 TP and 13 CP) and one false positive case of cellular pleomorphic adenoma (cytologic interpretation, mucoepidermoid carcinoma). All discrepant cases were processed using the TP method. The overall specificity and sensitivity were 98% and 88%, respectively. However, specificity and sensitivity for TP-processed SGFNABs were 96% and 82% as compared to a 100% specificity and sensitivity for CP. Additionally, there were 10 (14%) nondiagnostic cases, 8 of which were processed by TP. Cytologic artifacts associated with TP included diminished/distorted extracellular and stromal elements, cellular shrinkage and tissue fragmentation CONCLUSION: The diagnostic accuracy of TP-processed SGFNABs approaches that of the CP. However, there are several artifacts that may lead to erroneous diagnoses. Additional studies, that depend on real-life clinical samples processed by TP are suggested to modify current diagnostic criteria.

Artifacts↗

Digital chest radiography: effect on diagnostic accuracy of hard copy, conventional video, and reversed gray scale video display formats.

Observer performance tests were conducted to compare the effects on diagnostic accuracy of hard copy (film) versus video display and to determine the diagnostic merits of conventional negative ("white bone") versus positive ("black bone") video displays. Subjective preferences were elicited from each observer for each display modality, and diagnostic accuracy was determined with receiver operating characteristic analysis. Digitized chest radiographs were used, including normal and abnormal cases with a variety of subtle abnormalities. The hard copy was printed with a 1,024 X 1,024-matrix by a high-quality drum scanner in conventional white bone format only. The video images were displayed on a 1,023-line monitor (30 Hz, interlaced) in both white bone and black bone formats with fixed window and brightness settings. Most observers preferred hard copy to video, but preferences were sharply divided between white bone and black bone video. Diagnostic accuracy was significantly greater with hard copy than with video display, and the conventional white bone format was significantly superior in accuracy to the black bone display.

Computer Systems↗

[Perforation rate and diagnostic accuracy in acute appendicitis].

OBJECTIVE: To determine perforation rate and diagnostic accuracy in acute appendicitis. DESIGN: Retrospective study. SETTING: Deaconesses' hospital Utrecht. METHOD: Data on 235 acute appendectomies performed between 1989 and 1991 were collected: duration of symptoms, doctor or patient delay, pathology, septic complications, and objective data such as body temperature, leukocyte count and sedimentation rate. RESULTS: Symptoms lasted on average 1.68 days and in 12.3% of the cases there was doctor delay, while an accurate diagnosis was made in 80%. The perforation rate was 18.3% and tended to be higher in young children and adults over 50. Septic complications ensued in 25% of the perforations. Perforation was associated with symptoms existing for longer than 48 hours. The number of negative appendectomies was 5 times higher in women than in men. The objective data were of limited diagnostic value. According to literature of the last 15 years, the mean value for perforation rate is 17% and for diagnostic accuracy 79%. CONCLUSION: In children and elderly appendicectomy should be considered earlier. For sexually mature women additional laparoscopy can be of help in decreasing the number of negative appendectomies. It is recommended not to observe patients too long.

Acute Disease↗

Diagnostic accuracy of magnetic resonance cholangiopancreatography and ultrasound compared with direct cholangiography in the detection of choledocholithiasis.

AIM: To determine the diagnostic accuracy of magnetic resonance cholangiopancreatography (MRCP) and trans-abdominal ultrasound in the detection of choledocholithiasis, and to compare bile duct stone characteristics using endoscopic retrograde cholangiopancreatography (ERCP), MRCP and ultrasound. MATERIALS AND METHODS: Of 191 consecutive patients referred for diagnostic ERCP, choledocholithiasis was diagnosed in 34 patients using direct cholangiography. The latter took the form of ERCP (n = 29), intraoperative cholangiography (n = 3) or percutaneous transhepatic cholangiography (n = 2). All patients underwent MRCP and ultrasound examinations and their findings for choledocholitiasis were compared with those at direct cholangiography. Finally, in the 29 patients with choledocholithiasis diagnosed under ERCP, stone characteristics were compared across the three investigations of ERCP, MRCP and ultrasound. RESULTS: Compared with direct cholangiography, MRCP showed a sensitivity, specificity and diagnostic accuracy of 91%, 98% and 97%, respectively, in the diagnosis of choledocholithiasis. MRCP resulted in three false-negative and three false-positive findings, four of which occurred due to confusion with lesions at the ampulla. Ultrasound showed a sensitivity, specificity and diagnostic accuracy of 38%, 100% and 89%, respectively, in the diagnosis of choledocholithiasis. ERCP revealed a greater number of stones and these were more proximally distributed within the bile ducts when compared to MRCP. CONCLUSIONS: MRCP is highly accurate in the diagnosis of choloedocholithiasis and has the potential to replace diagnostic ERCP. MRCP underestimates the number of bile duct stones present.

Adult↗

Diagnostic accuracy of pancreatic enzymes evaluated by use of multivariate data analysis.

We analyzed pancreatic enzyme data from 508 patients with suspected pancreatitis by neural network analysis, by an Expert multirule generation protocol, and by receiver-operator characteristic (ROC) curve analysis of a single test result. Neural network analysis showed that use of lipase provided the best means for diagnosing pancreatitis. Diagnostic accuracies achieved by using amylase only, lipase only, and amylase and lipase in combination were 76%, 82%, and 84%, respectively. Use of the Expert rule generation protocol provided a diagnostic accuracy of 92% when rules for single and multiple samplings were combined. ROC curve analysis for initial enzyme activities showed the maximal diagnostic accuracy to be 82% and 85% for amylase and lipase, respectively; use of peak enzyme activities yielded accuracies of 81% and 88%, respectively. The evaluation of laboratory test data should include analysis of the diagnostic accuracy of laboratory tests by multivariate techniques such as neural network analysis or an Expert systems approach. Multivariate analysis should allow for a more realistic assessment of the diagnosis accuracy of laboratory tests because all the available data are included in the evaluation.

Amylases↗

[Adding atropine improves the diagnostic accuracy of dipyridamole-echo test].

BACKGROUND: The clinical experience with dipyridamole stress echocardiography for the diagnosis of coronary artery disease (CAD) revealed that patients with less severe extent of CAD and limited impairment of coronary reserve are frequently not recognized by the test. Increasing myocardial oxygen consumption adding atropine to dipyridamole may improve the diagnostic accuracy of dipyridamole for the detection of CAD. METHODS: Fifty-two patients (48 men, aged 53 +/- 7 years) underwent a high-dose dipyridamole-echo stress test (0.84 mg/kg over 10 minutes) and coronary arteriography within 15 days from the test. Eighteen out of 52 patients were referred for chest pain; 11 suffered from a previous myocardial infarction (MI) and 23 were studied in the early phase after a first acute MI. Starting after 4 minutes from the end of dipyridamole infusion, atropine was added, in 2 doses of 0.5 mg each, at 1-minute interval in those patients with no echocardiographic evidence of myocardial ischemia after dipyridamole alone. Left ventricular wall motion was analyzed on a 11-segment left ventricular model in a qualitative manner. RESULTS: Dipyridamole-echo stress test was positive in 23/52 (44%) and negative in 29/52 (56%) patients. In these patients atropine was added resulting in an additional echo positivity in 14/29 patients. Coronary arteriography was normal in 6 patients (12%); 1-vessel CAD was diagnosed in 23 (44%), 2-vessel CAD in 13 (25%) and 3-vessel CAD in 10 (19%) cases. The sensitivity for CAD diagnosis was 48% (22/46) for dipyridamole alone and 76% (35/46) for dipyridamole-atropine echo (p < .005), while the specificity was 83% (5/6) and 80% (4/5) respectively. Diagnostic accuracy increased from 52% (27/52) to 75% (39/52) (p < .001). The better diagnostic accuracy of dipyridamole-atropine echo stress test was mainly related to the increased sensitivity of the combined test in patients with 1-vessel CAD (from 39% to 70%) (p < .005). Peak heart rate was significantly higher after the addition of atropine (100 +/- 17 beats/min) compared to basal (64 +/- 10) and dipyridamole (85 +/- 12) in those patients with a positive dipyridamole-atropine echo stress test. No limiting side effects were elicited with the addition of atropine to dipyridamole. CONCLUSIONS: The combination of atropine and dipyridamole induces a chronotropic stress adjunctive to flow maldistribution phenomena that permits to increase diagnostic accuracy of dipyridamole-echo stress test particularly in patients with less severe extent of CAD; it is usually well tolerated and safe and may be considered as a useful procedure for optimizing diagnostic value of dipyridamole-echo stress test.

Aged↗

Phospholipid autoantibodies and the antiphospholipid antibody syndrome: diagnostic accuracy of 23 methods studied by variation in ROC curves with number of clinical manifestations.

BACKGROUND: We analyzed the diagnostic accuracies for the diagnosis of antiphospholipid syndrome (APS) of 23 antiphospholipid antibody (APL-Ab) assays targeted at different antigen preparations and immunoglobulin isotypes. METHODS: In 144 patients with suspected APS, anti-cardiolipin (aCL) and anti-beta2-glycoprotein I (abeta2GPI) antibodies were measured with 23 different ELISAs from three manufacturers. Data were analyzed by ROC curves. In the absence of an accepted criterion standard, the endpoint "diagnosis of APS" was varied according to the number (two through five) of signs and symptoms of APS. RESULTS: Although the presence of lupus anticoagulant was associated significantly with APL-Ab in 10 of 23 assays (P = 0.01-10(-4)) and recurrent arterial or venous occlusions were significantly associated with APL-Ab of IgM isotype in 5 of 6 assays (P = 0.02-10(-4)), sensitivity for detection of APS did not exceed 67%. With the exception of IgA APL-Ab, the diagnostic accuracy of the assays improved when the diagnosis of APS was based on an increasing number of simultaneous features of APS. For most methods, areas under the ROC curves were >0.8 irrespective of the method's subclass specificity and antigen preparation (aCL or abeta2GPI), if the clinical diagnosis of APS was based on four or more signs and symptoms of APS. CONCLUSION: Despite considerable heterogeneity in the individual test results, a single test of IgG or IgM isotype targeted at either aCL or abeta2GPI antibodies has excellent diagnostic accuracy when the criterion for diagnosis requires four or more typical manifestations of APS.

Adult↗

Diagnostic accuracy of magnetic resonance imaging for detecting posterior ligamentous complex injury associated with thoracic and lumbar fractures.

OBJECT: The posterior ligamentous complex (PLC) in the thoracic and lumbar spine is one of the region's important stabilizers. The precise diagnosis of PLC injury is required to evaluate the instability of the injured spine; however, the accuracy of magnetic resonance (MR) imaging for diagnosing PLC injury has remained unclear. In this study, the authors compared preoperative MR imaging findings with direct intraoperative observation of PLC injury, clarifying the former's diagnostic accuracy regarding detection of PLC injury associated with the thoracic and lumbar fractures. METHODS: Data obtained in 35 patients who sustained thoracic or lumbar injuries were reviewed. There were 17 burst fractures, six flexion-distraction injuries, and 12 fracture dislocations. Each patient underwent MR imaging examination within 3 weeks of injury. Three radiologists independently evaluated sagittal MR images in a blinded fashion. The PLC-related information was retrospectively collected from each operative record. The diagnostic accuracy of MR imaging was analyzed by comparing imaging-documented intraoperative findings. The PLC injuries were detected in 23 patients (65.7%) by direct observation during posterior spinal procedures. The diagnostic accuracy of MR imaging in detecting injury of the supraspinous ligament (SSL) and interspinous ligament (ISL) was 90.5 and 94.3%, respectively. The specificity of T1-weighted MR imaging alone for depicting the SSL was significantly greater than T2-weighted imaging alone (p < 0.05). The overall mean kappa coefficient for MR imaging findings of PLC injury was 0.803, which indicated excellent interobserver reliability; that for ISL (0.915) was significantly greater than that for SSL (0.69) (p < 0.05). CONCLUSIONS: This study clarified a high diagnostic accuracy and interobserver reliability of MR imaging for PLC injury. The precise diagnosis of PLC injury is essential to determine the mechanical instability of the injured thoracic and lumbar spine, especially in differentiating unstable (three-column) burst fractures from the relatively stable (two-column) type. The authors conclude that MR imaging is a powerful diagnostic tool to evaluate PLC injury associated with thoracic and lumbar fractures.

Humans↗

Effects of morphine analgesia on diagnostic accuracy in Emergency Department patients with abdominal pain: a prospective, randomized trial.

BACKGROUND: Because of concerns about masking important physical findings, there is controversy surrounding whether it is safe to provide analgesia to patients with undifferentiated abdominal pain. The purpose of this study was to address the effects of analgesia on the physical examination and diagnostic accuracy for patients with abdominal pain. STUDY DESIGN: The study was a prospective, double-blind clinical trial in which adult Emergency Department (ED) patients with undifferentiated abdominal pain were randomized to receive placebo (control group, n = 36) or morphine sulphate (MS group, n = 38). Diagnostic and physical examination assessments were recorded before and after a 60-minute period during which study medication was titrated. Diagnostic accuracy and physical examination changes were compared between groups using univariate statistical analyses. RESULTS: There were no differences between control and MS groups with respect to changes in physical or diagnostic accuracy. The overall likelihood of change in severity of tenderness was similar in MS (37.7%) as compared with control (35.3%) patients (risk ratio [RR] 1.07, 95% confidence interval [CI] 0.64-1.78). MS patients were no more likely than controls to have a change in pain location (34.0% versus 41.2%, RR 0.82, 95% CI 0.50-1.36). Diagnostic accuracy did not differ between MS and control groups (64.2% versus 66.7%, RR 0.96, 95% CI 0.73-1.27). There were no differences between groups with respect to likelihood of any change occurring in the diagnostic list (37.7% versus 31.4%, RR 1.20, 95% CI 0.71-2.05). Correlation with clinical course and final diagnosis revealed no instance of masking of physical examination findings. CONCLUSIONS: Results of this study support a practice of early provision of analgesia to patients with undifferentiated abdominal pain.

Abdominal Pain↗

Diagnostic accuracy of oropharyngeal cultures in infants and young children with cystic fibrosis.

The objective of this study was to assess the diagnostic accuracy of oropharyngeal (OP) cultures relative to simultaneous bronchoalveolar lavage (BAL) cultures in very young children with CF, and to examine the effects of bacterial density, age, and study cohort on diagnostic accuracy. Respiratory culture data were analyzed from three independent, prospective studies involving simultaneous collection of 286 OP and BAL cultures from 141 children with CF <5 years of age. For predicting any growth of Pseudomonas aeruginosa (Pa) from the lower airway in subjects </=18 months of age (mean age, 8 +/- 5 months), OP cultures had a sensitivity of 44% (95% CI 14%, 79%), specificity of 95% (90%, 99%), positive predictive value of 44% (14%, 79%), and negative predictive value of 95% (90%, 99%). Diagnostic accuracy was similar for Haemophilus influenzae (Hi). Specificity was significantly lower for Staphylococcus aureus (Sa). Sensitivity for all organisms improved if a positive lower airway culture was defined as >/=10(3) or >/=10(5) cfu/mL. Specificity for Pa declined significantly with increasing age. In children with CF <5 years of age, the specificity and negative predictive value of OP cultures for Pa are high, while the sensitivity and positive predictive value are poor. Thus, in this age range, a negative throat culture is helpful in "ruling out" lower airway infection with Pa. However, a positive culture does not reliably "rule in" the presence of Pa in the lower respiratory tract. These findings may have implications for study design and interpretation as well as clinical management of young children with CF.

Bacterial Infections↗