Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Transillumination”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

A quantitative fluorescence-based microplate assay for the determination of double-stranded DNA using SYBR Green I and a standard ultraviolet transilluminator gel imaging system.

Various assays are available for quantification of DNA in solution, but none has been described that is both sensitive and specific for double-stranded (ds) DNA and features practical properties such as low dye and equipment costs, speed, and highly parallel microplate formats. Here we show that quantitative and sensitive measurement of ds DNA in solution is achieved using a 96-well microplate SYBR Green I assay and a standard uv transillumination-based gel-imaging system for detection. Specific detection of ds DNA was obtained over a broad concentration range of 0.5-500 ng using a single low dye concentration of up to 1/6250. Measured SYBR Green I fluorescence was not significantly affected by pH variation (4-10), assay volume (50-250 microliter l), and time (4-15 min), and measurements were appreciably compatile with commonly encountered concentrations of contaminating salts, organics, detergents, and other substances. ds DNA yielded up to 13-fold higher fluorescence compared to single-stranded DNA or RNA, but this ratio was dependent somewhat on GC content and fragment size. Of note, linear ds DNA fluoresced significantly stronger than supercoiled plasmid DNA. Our method should be broadly applicable for sensitive, rapid, and inexpensive ds DNA quantification in the average molecular biology laboratory.

Base Composition↗

Incomplete cerebral ischemia in the rat: vascular and metabolic changes as measured by infrared transillumination in vivo.

Cerebral blood volume, hemoglobin saturation and the cytochrome a, a3 redox state were monitored simultaneously by using three wavelengths of light in the near infrared portion of the spectrum for transillumination of the intact skull of rats. The changes in these parameters following incomplete cerebral ischemia were assessed in Wistar and Long-Evans rats submitted to carotid ligation. Another group of Wistar rats was submitted to vertebral + carotid occlusion. The experiments, performed under N2O/O2 anesthesia, showed that in all three groups carotid occlusion induced a decrease in blood volume, Hb saturation and a reduction of cyt. a, a3. However, the cytochrome redox state tended to normalize during ischemia as a consequence of higher O2 extraction from blood. The primary finding of this study was the marked hyperoxidation of cyt. a, a3 which occurred after reestablishing of the carotid blood supply, in spite of a secondary post-ischemic hypoperfusion of the brain. Although uncoupling of oxidative phosphorylation cannot be excluded the dissociation between blood supply and metabolism could well be due to ischemia-induced hypermetabolism of the central nervous tissue. In view of the marked oxidation of cyt. a, a3 during the reperfusion period as compared with the small extent of its reduction during the ischemic episode, the data also support the hypothesis that under steady state conditions in vivo, cytochrome oxidase is mainly reduced.

Animals↗

Fiberoptic intraluminal transillumination of the cystic duct and the common bile duct.

We have developed two new fiberoptic instructions for outlining the anatomic characteristics of the extrahepatic biliary tree. By transilluminating the common and cystic ducts and duodenum, any obstruction or pathologic abnormalities can be visualized and located. These instruments can be used instead of intraoperative cholangiography when indicated.

Common Bile Duct↗

Imaging mammalian tissues and organs using laser collimated transillumination.

Images of mammalian organs were built up using a Laser collimated transillumination device equipped with a bidirectional scanning setup. A microcomputer was used to run the scanning process, acquisition of detected signals and images restitution. The images featured a satisfactory resolution of optical discontinuities on both sample surfaces. Light scattering within biological tissues restricted the spatial discrimination encountered with geometrical selection approach. By combining space and time resolution at various wavelengths, the production of an efficient tomospectroscopy could be envisaged.

Animals↗

Effects of optical constants on time-gated transillumination of tissue and tissue-like media.

Light transillumination was used to study structures inside turbid media. Time-gated viewing was performed to suppress multiply-scattered light and thus improve spatial resolution. We demonstrate that, for the case of scattering-dominated attenuation (scattering coefficient much greater than the absorption coefficient), the detection of early transmitted light will be practically insensitive to variations in the absorption coefficient. This is an important observation for the development of time-gated optical mammography, since optical mammography using continuous-wave light is based on increased light absorption in the tumour region caused by the neovascularization surrounding a tumour. In order to detect tumours in time-gated viewing it is the scattering coefficient of the tumour that must be characteristic. The scattering coefficient is measured to be lower in the tumour region than in the surrounding breast tissue for one resected breast specimen.

Female↗

Optical transillumination tomography with tolerance against refraction mismatch.

Optical transillumination tomography (OT) is a laser-based imaging modality where ballistic photons are used for projection generation. Image reconstruction is therefore similar to X-ray computed tomography. This modality promises fast image acquisition, good resolution and contrast, and inexpensive instrumentation for imaging of weakly scattering objects, such as for example tissue-engineered constructs. In spite of its advantages, OT is not widely used. One reason is its sensitivity towards changes in material refractive index along the light path. Beam refraction artefacts cause areas of overestimated tissue density and blur geometric details. A spatial filter, introduced into the beam path to eliminate scattered photons, will also remove refracted photons from the projections. In the projections, zones affected by refraction can be detected by thresholding. By using algebraic reconstruction techniques (ART) in conjunction with suitable interpolation algorithms, reconstruction artefacts can be partly avoided. Reconstructions from a test image were performed. Standard filtered backprojection (FBP) showed a round mean square (RMS) deviation from the original image of 9.9. RMS deviation with refraction-tolerant ART reconstruction was 0.33 and 0.24, depending on the algorithm, compared to 0.57 (FBP) and 0.06 (ART) in a non-refracting case. In addition, modified ART reconstruction allowed detection of small geometric details that were invisible in standard reconstructions. Refraction-tolerant ART may be the key to eliminating one of the major challenges of OT.

Algorithms↗

Transillumination for accurate placement of radioactive plaques in brachytherapy of choroidal melanoma.

PURPOSE: To present a technique for accurate plaque placement in episcleral brachytherapy of choroidal melanoma. METHODS: The tumor margins are marked on the scleral surface, and a dummy plaque is temporarily sutured to the globe. A fiber optic light pipe is then wedged into the space between the sclera and the plaque. Because of the reflecting inner surface of the plaque, the perimeter of the plaque can easily be observed during indirect ophthalmoscopy as a circle of light surrounding the tumor. By this method, it is possible to determine the exact position of the entire plaque in relation to the tumor and make the necessary adjustments. When the correct position is found, the dummy plaque is replaced by a radioactive plaque. RESULTS: Since 1993, we have routinely used this procedure in episcleral brachytherapy. CONCLUSION: This modified transillumination technique facilitates a correct positioning of episcleral plaques.

Brachytherapy↗

The transillumination possibility of imidazole-osmium postfixed tissue and its consequences for the handling of tissue samples.

Osmium postfixation is established as a routine procedure for transmission electron microscopy (TEM). On the one hand, this routine procedure leads to good results for TEM, but on the other hand results in blackened tissue samples that do not allow examination of any structures within the embedded tissue sample by a light microscope. Equivalent fixation results for TEM are achieved with imidazole-osmium postfixation, and with this postfixation method tissue is not blackened and can be transilluminated with point light sources. This allows easier recognition of histological details within tissue samples and makes it possible to screen embedded samples for appropriate ultrastructural processing. Jejunum is used to demonstrate the method.

Animals↗

Determination of the attenuation properties of laboratory gloves exposed to an ultraviolet transilluminator.

The transmission of ultraviolet radiation (UVR) from an ultraviolet transilluminator through three types of laboratory gloves (latex, nitrile, vinyl) was determined using two independent methods. First, transmittance was measured with a radiometer equipped with UVA and actinic UV detectors. Second, a spectrophotometer was used to determine the UVR transmittance vs. wavelength (250-440 nm); this data was then used to compute the effective attenuation of the glove material. The average UVA percent transmittance using the radiometer method with an unstretched glove was 73.4%, 0.18%, and 1.10% for vinyl, nitrile, and latex, respectively. The average actinic percent transmittance for an unstretched glove was 13.3%, 0.015%, and 0.024% for vinyl, nitrile, and latex, respectively. Slight increases in UVR transmittance resulted from stretching the gloves by 30% or wetting them with saline. Six hours of UVR exposure decreased transmittance of vinyl gloves and increased transmittance by latex gloves. Results from the spectrophotometer method and radiometer methods of determining UVR transmittance agreed that vinyl gloves had the highest transmittance; however, the spectrophotometer method greatly overestimated UV glove attenuation due to the effect of light scattering by the glove material. The study suggests that in some circumstances, vinyl gloves will provide inadequate protection against workplace ultraviolet radiation.

Equipment Failure↗

Iris transillumination defects in the pigment dispersion syndrome as detected with infrared videography: a comparison between a group of blacks and a group of nonblacks.

BACKGROUND: Infrared image analysis has been reported to be the most sensitive method to detect iris transillumination defects (ITDs) associated with the pigment dispersion syndrome (PDS). Although a common sign of PDS in patients with lighter irides, ITDs that are demonstrated with standard slit lamp examination are frequently absent in blacks with the disease. This absence may lead to confusion in diagnosis; therefore improved methods of evaluation could be beneficial. Although infrared image analysis has been investigated in nonblacks, it has not been applied to a group of blacks with the condition. METHODS: Six blacks (11 eyes, all irides brown) with PDS and eight nonblacks (15 eyes, 10 blue irides, 5 brown irides) with PDS underwent analysis. ITDs were searched for with traditional slit lamp examination and with infrared videography. RESULTS: Among the blacks, 2 of 11 eyes (18%) showed ITDs via infrared analysis, a frequency that was significantly lower (p < 0.001) than the frequency exhibited among the nonblacks (100%) when examined with the same technique. Standard slit lamp examination also showed a significantly lower frequency of ITDs among the blacks compared to the nonblacks (p < 0.001). Infrared videography detected ITDs at least one grade higher in 1 of 11 eyes (9%) among the black group and in 7 of the 15 eyes (47%) among the nonblacks. Using the Wilcoxon signed ranks test, the difference in the ability of infrared videography to detect and rank the iris defects in the nonblack PDS group was significantly greater when compared to standard slit lamp examination (p = 0.011), but infrared analysis did not increase detection or change the mean ranking of those in the black group (p = 0.317). CONCLUSION: In this group of patients, infrared videography did not significantly improve the detection and visibility of ITDs in blacks, as it did in the nonblacks. The frequency that ITDs were detected with standard slit lamp examination and with infrared videography was significantly greater in the group of nonblacks compared to the blacks who exhibited PDS.

Adolescent↗

Digital camera system to perform infrared photography of iris transillumination.

The authors modified a standard digital camera by replacing an internal infrared-blocking filter that allowed photography of iris transillumination defects. Visible and infrared light was produced with a halogen fiberoptic light source that was placed against the inferior eyelid and directed perpendicular to the globe. To obtain images, the camera was mounted to a tabletop tripod placed 3 to 5 in from a chin/headrest apparatus. Images were downloaded onto a personal computer via software and accessories provided by the camera manufacturer. This technique, which is convenient and produces high quality, color images, can highlight details of the normal and pathologic iris. It may have significant utility in clinical research as well as routine clinical care.

Exfoliation Syndrome↗

Three-dimensional reconstruction of transillumination tomographic images of human breast phantoms by red and infrared lasers.

A laser transillumination tomographic system, using red and near infrared lasers, to obtain cross-sectional images of human breast phantoms and human hand is proposed. The scanning assembly is consisting of upward, downward, rotational and pitch movements. The phantoms, made of paraffin wax, agar gel, and milk placed in a glass model, are embedded with abnormalities like blood, water, solid objects, and tissues. By illuminating the phantoms at various heights by either red or infrared laser the projection data are collected. Based on 64 projections the tomogram of each section is constructed. By volume visualization procedure applied to the tomograms the objects of varying composition embedded within the phantoms are detected and their size, shape, and location depth are determined. The cross-sectional image of a human hand obtained by this procedure further shows the possibility of application of this technique for imaging of organs.

Algorithms↗

Technical foundations for noninvasive assessment of changes in the width of the subarachnoid space with near-infrared transillumination-backscattering sounding (NIR-TBSS).

This paper presents technical foundations for a new technique of near-infrared transillumination-backscattering sounding, which is designed to enable noninvasive detection and monitoring of changes in the width of the subarachnoid space (SAS) and magnitude of cerebrovascular pulsation in humans. The key novelty of the technique is elimination of influence of blood flow in the scalp on the signals received from two infrared sensors-proximal and distal. A dedicated digital algorithm is used to estimate on line the ratio of the powers of received signals, referred to as two-sensor distal-to-proximal received power quotient, TQ (t). The propagation duct for NIR radiation reaching the distal sensor is the SAS filled with translucent cerebrospinal fluid. Information on slow fluctuations of the average width of the SAS is contained in the slow-variable part of the TQ (t), called the subcardiac component, and in TQ itself. Variations in frequency and magnitude of faster oscillations of the width of that space around the baseline value, dependent on cerebrovascular pulsation, are reflected in instantaneous frequency and envelope of the fast-variable component. Frequency and magnitude of the cerebrovascular pulsation depend on the action of the heart, so this fast-variable component is referred to as the cardiac component.

Algorithms↗

The efficacy of a standard training program for transillumination-guided endotracheal intubation.

OBJECTIVE: To evaluate the success rate, intubation time, and complication rate of transillumination-guided intubation following two hours of instruction in the use of the Trachlight (TL) device. METHODS: A prospective, randomized crossover laboratory trial was conducted at an emergency medical service training site with 30 nonpaid volunteer paramedic students, one month prior to their graduation. The students were instructed in the use of the TL in a standardized curriculum consisting of didactic, video, and demonstration sessions. Each student was required to successfully intubate a training manikin with the TL five times. Approximately three weeks later, the students were asked to intubate the manikin 20 times, alternating between direct laryngoscopy (DL) and TL. RESULTS: The success rates were 94% for DL and 63% for TL (p < 0.0001). The mean intubation times were 14.6 seconds for DL and 16.8 seconds for TL (p < 0.001). The incidences of trauma were 7.3% for DL and 1.4% for TL (p < 0.001). CONCLUSION: A two-hour training session, including five successful light-guided intubations using the TL, was inadequate for producing acceptable success rates during manikin intubations by paramedic students. While TL intubation intervals were shorter when successful, the 2.2-second difference was not clinically meaningful. The incidence of trauma in our manikin model during TL intubations was significantly lower than that with DL.

Cross-Over Studies↗

Evaluation of the transilluminated Amsler grid for macula testing in cataract patients.

A transilluminated, modified Amsler grid was used for evaluation of the macula in 80 cataract patients of whom 19 had abnormal maculas. The results were compared to those obtained with a commonly used test: colour perception. As control of the tests the post-operative visual acuity and ophthalmoscopic macula inspection was used. Of the diseased maculas 68% were identified by the Amsler grid test and only 32% by the colour perception test. Both tests identified a high proportion of normal maculas: 90% by Amsler grid test and 89% by colour perception test. A pathological response to the Amsler grid test indicated a 68% probability of macular disease, and a normal test result indicated a 90% probability of normal macula. Only the Amsler grid test however is not applicable to all cataract patients: Of originally 110 patients taken in for this test, 30 patients (27%) could not see the grid at all, whereas all 110 patients could be tested with the colour perception test.

Cataract↗

Depth dependence of the analytical expression for the width of the point spread function (spatial resolution) in time-resolved transillumination.

Simple analytical expressions for the point spread function (PSF) at different depths can save computation time and improve the performance of inverse algorithms for optical imaging. In particular, application of such formulas simplifies quantification of the optical characteristics of tissue abnormalities inside highly scattering media. Earlier it was shown within the random walk theory framework that the PSF for time-resolved transillumination imaging through a highly scattering slab is well represented by a Gaussian. We have experimentally validated a simple formula of the random walk model for the effective width of this Gaussian, as a function of time delay, at different depths of the target. Presented analysis of published experimental data, concerning effective width of the PSF, for a slab of considerably smaller thickness also demonstrates good agreement between the data and predictions of our model. This PSF width determines spatial resolution of the time-resolved imaging and is widely discussed in the literature.

Diagnostic Imaging↗

Transillumination optical tomography of tissue-engineered blood vessels: a Monte Carlo simulation.

A Monte Carlo technique has been developed to simulate the transillumination laser computed tomography of tissue-engineered blood vessels. The blood vessel was modeled as a single cylinder layer mounted on a tubular mandrel. Sequences of images were acquired while rotating the mandrel. The tomographic image was reconstructed by applying a standard Radon transform. Angular discrimination was applied to simulate a spatial filter, which was used to reject multiply scattered photons. The simulation results indicated that the scattering effect can be overcome with angular discrimination because of the thin tissue thickness. However, any refractive-index mismatch among the tissue, the surrounding media, and the mandrel could produce significant distortions in the reconstructed image.

Animals↗

Fundamental imaging properties of transillumination laser computed tomography based on coherent detection imaging method.

The coherent detection imaging (CDI) method uses the optical heterodyne detection technique. CW and single frequency lasers having long coherence lengths are used to exploit the maximum advantages of heterodyne detection, such as high directionality, selectivity and sensitivity. The CDI method based on optical heterodyne detection enables selective filtering of the directional coherence-retaining emergent photons, which leads to image reconstruction from projections, similar to X-ray computed tomography (CT). So far we have demonstrated the advantages and capabilities of the measurement technique for transillumination optical computed tomography in biomedicine. Here, we investigate the fundamental imaging properties of CDI method, such as its high directionality and quantitativeness, with preliminary physical phantom experiments. The results show that the CDI method satisfies the requirements for CT reconstruction under the first order approximation, and enables quantitative measurements in the sense that the relationship between estimated and actual concentration retains a satisfactory linearity.

Equipment Design↗