Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Statistics as Topic”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

A light curing method for improving marginal sealing and cavity wall adaptation of resin composite restorations.

OBJECTIVE: The aim of this study was to evaluate whether the method of light curing could influence: (a) marginal sealing and resin composite adaptation to the cavity wall; (b) polymerization contraction rate; and (c) the hardness at the top and bottom surfaces of a body of resin composite. METHODS: Standard cylindrical cavities, 1mm deep and 3mm in diameter were prepared on flat superficial dentin surfaces in bovine teeth. The teeth were bonded with one of two adhesive systems (Clearfil Photo Bond, and Super-Bond D Liner) and filled with a hybrid resin composite. The resins were cured using three light intensities of 600, 270 and 20mW/cm(2), and various curing times. After thermal cycling, the specimens were subjected to a dye penetration test to evaluate marginal sealing and adaptation of the resin composite to the cavity walls. In addition, using the same curing conditions, the rate of polymerization contraction was measured. The difference of hardness over time of composite specimens was measured using Knoop hardness measurements taken at the top and bottom surfaces of resin specimens made in a Teflon mold the same dimensions as the cavity prepared in dentin. RESULTS: When the composite was light cured with an initial light intensity of 270mW/cm(2) for 10s, a 5s interval then a light intensity of 600mW/cm(2) for 50s, the best marginal sealing and cavity wall adaptation was observed compared with the other curing modes. Earlier hardening occurred at the resin composite base compared with the top surface of the composite, and most of the polymerization contraction was completed during the initial flowable stage of the resin composite. All other methods demonstrated results with some degree of marginal opening and cavity wall gap formation, the worst being 600mW/s for 60s. SIGNIFICANCE: The use of a low initial light intensity (270mW/cm(2)) for 10s followed by high intensity light (600mW/cm(2)) for 50s provides the best adaptation of resin composite to cavity walls and possibly the least polymerization contraction stress.

Analysis of Variance↗

Aggressiveness of contemporary self-etching adhesives. Part II: etching effects on unground enamel.

OBJECTIVES: The aggressiveness of three self-etching adhesives on unground enamel was investigated. Ultrastructural features and microtensile bond strength were examined, first using these adhesives as both the etching and resin-infiltration components, and then examining their etching efficacy alone through substitution of the proprietary resins with the same control resins. METHODS: For SEM examination, buccal, mid-coronal, unground enamel from human extracted bicuspids were etched with either Clearfil Mega Bond (Kuraray), Non-Rinse Conditioner (NRC; Dentsply DeTrey) or Prompt L-Pop (ESPE). Those in the control group were etched with 32% phosphoric acid (Bisco) for 15s. They were all rinsed off prior to examination of the etching efficacy. For TEM examination, the self-etching adhesives were used as recommended. Unground enamel treated with NRC were further bonded using Prime&Bond NT (Dentsply), while those in the etched, control group were bonded using All-Bond 2 (Bisco). Completely demineralized, resin replicas were embedded in epoxy resin for examination of the extent of resin infiltration. For microtensile bond strength evaluation, specimens were first etched and bonded using the self-etching adhesives. A second group of specimens were etched with the self-etching adhesives, rinsed but bonded using a control adhesive. Following restoration with Z100 (3M Dental Products), they were sectioned into beams of uniform cross-sectional areas and stressed to failure. RESULTS: Etching patterns of aprismatic enamel, as revealed by SEM, and the subsurface hybrid layer morphology, as revealed by TEM, varied according to the aggressiveness of the self-etching adhesives. Clearfil Mega Bond exhibited the mildest etching patterns, while Prompt L-Pop produced an etching effect that approached that of the total-etch control group. Microtensile bond strength of the three experimental groups were all significantly lower than the control group, but not different from one another. When the self-etching adhesives were replaced with the control adhesive after etching, bond strengths of NRC/Prime&Bond NT and Prompt L-Pop were not significantly different from that of the control group, but were significantly higher than that of Clearfil Mega Bond. SIGNIFICANCE: Both etching efficacy and strength of the resins are important contributing factors in bonding of self-etching adhesives to unground enamel.

Acid Etching, Dental↗

Comparison of pulse activation vs conventional light-curing on marginal adaptation of a compomer conditioned using a total-etch or a self-etch technique.

OBJECTIVES: This study investigated the effect of two factors: conditioning methods and light-curing techniques on the marginal adaptation of Dyract AP (Dentsply DeTrey, Germany). The 'pulse activation' curing technique was compared with a conventional light-curing technique for their effectiveness in reducing marginal gaps in restorations that were conditioned with three different protocols. MATERIALS AND METHODS: Cylindrical cavities, 3mm in diameter, were prepared in extracted human molar teeth. They were restored with Dyract AP using Prime&Bond NT (PBNT; Dentsply DeTrey) as the adhesive. Cavities were etched with: Conditioner36/PBNT (group 1), Non-Rinse Conditioner (NRC)/PBNT (group 2), and PBNT only (group 3). Either conventional or the 'pulse activation' technique was used for light-curing of the material. Epoxy resin replicas were obtained from longitudinal sections of the specimens, and the restoration-tooth interfaces were examined using scanning electron microscopy. Marginal qualities along the resin-dentin interfaces were further measured using image analysis and analyzed using nonparametric statistical methods. RESULTS: With the conventional curing technique, enamel margin fractures were frequently observed. Marginal gaps were found along the compomer-dentin interfaces irrespective of the conditioning protocol. A significantly lower percentage of gap-containing margins were found in cavities that were conditioned with 36% phosphoric acid. With the 'pulse activation' technique, no marginal gap was found along compomer-dentin interfaces that were etched with either Conditioner36 or NRC. More than 90% of the total margin length were excellent. No cohesive failure of enamel could be observed along cavosurface margins. SIGNIFICANCE: The 'pulse activation' curing technique significantly improves the marginal integrity of Dyract AP when Conditioner36/Prime&Bond NT and NRC/Prime&Bond NT are used as conditioning/bonding systems. The use of Prime&Bond NT without etching is not recommended, as marginal gaps are present irrespective of the curing techniques employed.

Acid Etching, Dental↗

The effects of luting resin bond to dentin on the strength of dentin supported by indirect resin composite.

OBJECTIVES: The purpose of this study was to evaluate the effects of thickness and adhesion of three resin cements on the fracture resistance of indirect resin composite bonded to dentin. METHODS: A disk of resin composite used for indirect restorations was bonded to a disk of bovine dentin using three kinds of resin cements with various bonding procedures. The bonding procedures were planned into five groups according to the materials and methods, and subsequently subdivided into three groups according to the cement thickness (50, 150 and 500 microm) in each bonding procedure. The thickness of the resin cement and that of the resin composite disk was changed simultaneously while maintaining a total specimen thickness of 2 mm. The prepared specimens were then stored in water at 37 degrees C for 24h at which time they were trimmed to a size of 2 x 2 x 8 mm. The trimmed specimens were subjected to a three point bending test and the fracture load determined. The tensile bond strength of each bonding procedure was measured and the correlation to the fracture load evaluated. RESULTS: The fracture load was affected by the dentin bond strength. The effect of cement film thickness on the fracture load was negligible. SIGNIFICANCE: When an indirect restoration is adhered to the tooth substrate, the adhesion of the luting cement to the tooth substrate is very important for the fracture resistance of indirect resin composite.

Acid Etching, Dental↗

Blood contamination and dentin bonding--effect of anticoagulant in laboratory studies.

OBJECTIVE: To investigate the influence of heparinized blood vs. native blood on the marginal adaptation of dentin bonded composite resin restorations. METHODS: Cylindrical dentin cavities were prepared in 40 extracted human incisors. After acid-etching four groups (n=10) were contaminated with either fresh capillary blood (FCB), heparinized venous blood (HPB), saline (SAL) or heparinized saline (HPS) and bonded and filled with Scotchbond 1/Z 100. After water storage for 21 days and thermocycling (2000 x, 5-55 degrees C), replicas were produced for evaluation of marginal adaptation by means of quantitative marginal analysis in the SEM. Statistical analysis was performed with the Kruskal-Wallis-test and the Bonferroni correction for multiple comparisons at p<0.05. RESULTS: There were no differences between groups SAL, HPS and HPB. Contamination with fresh capillary blood resulted in significantly higher amounts of marginal openings compared to all other groups. SIGNIFICANCE: Freshly drawn blood has to be used for blood contamination experiments in laboratory studies.

Acid Etching, Dental↗

The use of flowable composites as filled adhesives.

OBJECTIVE: The effect of filled adhesives on bonding resin composites to dentin has not been fully understood. Due to their filler content, filled adhesives may act as stress breakers. The aim of this in vitro study was to evaluate the use of flowable composites of different viscosities on bonding to enamel and dentin without the use of an intermediate bonding resin. MATERIALS AND METHODS: Enamel and dentin bond strengths of OptiBond FL, Syntac Classic, and EBS Multi combined either with their proprietary bonding agent or a flowable resin composite (Ultraseal XT Plus or Revolution) were measured. The tests were carried out with a microtensile device at a crosshead speed of 1mm/min after 24h of storage at 37 degrees C in water. Mean bond strengths were analyzed using the Wilcoxon test and multiple comparisons according to the Mann-Whitney U-test. The micro-morphology of corresponding resin-dentin interfaces of the same teeth were analyzed using SEM and TEM. RESULTS: The control groups with adhesive systems used as per manufacturers' protocol showed bond strengths of 38.9-41.1 MPa to enamel and 28.8-33.4 MPa to dentin. With respect to bond strength to etched enamel, only Ultraseal XT Plus as bonding resin reached the level of the control groups. When used as bonding agents on dentin, both flowable composites produced lower microtensile bond strengths to etched and primed dentin than did the control groups. Micro-morphological analysis using SEM and TEM resulted in hybrid layer formation for both control and experimental groups. However, many areas of the resin-dentin interface showed insufficient penetration of the flowable composites at the top of the hybrid layer as well as numerous tubules obstructed by filler particles. CONCLUSIONS: The flowable composites tested in this study should not be used to replace bonding agents. Flowable composites of thinner viscosity, such as Ultraseal XT Plus, may bond to enamel adequately without the requirement of an intermediate bonding resin.

Acid Etching, Dental↗

A comparison of microtensile bond strengths of several dentin bonding systems to primary and permanent dentin.

OBJECTIVES: Limited information exists with regard to the adhesive ability of glass ionomer cements (GIC) and recently developed resin-based dentin bond systems to primary dentin. The aim of this study was to compare the microtensile bond strength of a conventional GIC (Fuji IX), a resin-modified GIC (Fuji II LC), and two resin-based dentin adhesives (Prime and Bond NT with NRC and Single Bond). The bonded interfaces were also observed using field emission electron microscopy(FE-SEM). METHODS: Microtensile bond test specimens were prepared on superficial dentin of primary and permanent molars. The specimens were bonded according to each manufacturer's instructions except for Prime and Bond NT/NRC which used Silux Plus resin composite instead of Dyract. Hour-glass shaped specimens were created (diameter of 1.2+/-0.02 mm) and stressed in tension at a crosshead speed of 1mm/min. Results were analyzed using two-way ANOVA and LSD test, fracture modes were analyzed using the Mann-Whitney U-test and Kruskall-Wallis test. Twelve specimens were prepared for each material on primary and permanent dentin. Samples were prepared in the same manner, then critical point dried, fractured and sputter-coated for the FE-SEM observations. RESULTS: Two-way ANOVA showed the overall bond strengths were greater for the permanent dentin compared with primary dentin. However, for individual material comparisons no differences among the bond strengths to primary and permanent dentin for Fuji IX (9.7, 12.2 MPa), Fuji II LC (16, 20.1 MPa), Prime & Bond NT/NRC (18.1, 21.6 MPa) and Single Bond (18.2, 21.6 MPa), were detected. However, Fuji IX bond strengths were significantly lower than the other systems tested when bonded to either primary or permanent dentin (p<0.05). Failure mode showed cohesive failure of GIC and mostly adhesive failure for the resin-based adhesives. The FE-SEM observations showed hybrid-like layer formation for the GIC materials and hybrid layer formation for the resin-based adhesives. SIGNIFICANCE: The materials tested would be suitable for bonding to either primary or permanent dentin, but the resin-modified GIC or resin-based systems are likely to provide a stronger bond than the conventional GIC, Fuji IX.

Acid Etching, Dental↗

Long-term tensile bond durability of two different 4-META containing resin cements to dentin.

OBJECTIVES: This study was conducted to evaluate the tensile bond durability of two different types of 4-META containing resin cements over a period of 3 years. METHODS: Ten bovine dentin specimens were tested for tensile bond strengths with each of the following materials: Super Bond C&B: unfilled methyl methacrylate (MMA)/polymethyl methacrylate (PMMA) resin cement, MASA Bond (experimental material): filled dimethacrylate resin cement at 1 day, 6 months, 1 and 3 years. The mean bond strengths were compared statistically by two-way ANOVA and Fisher's PLSD test (P<0.05). The mode of failure was classified by SEM observation. Results for the mode of fracture were analyzed using the Mann-Whitney U test. RESULTS: Although there was no statistical difference in mean bond strength between Super Bond C&B and MASA Bond (P>0.05) during the experimental periods, the 1-day bond strengths were significantly greater than those at the other experimental periods except for 6 months (P<0.05). Regarding the fracture modes, at 6 months and 1 year, statistical differences were observed between Super Bond C&B and MASA Bond (P<0.05). SIGNIFICANCE: The bond strengths of both resin cements to dentin significantly decreased after 6 months, and the long-term failure patterns of the 4-META/TBB resin cements showed a marked change.

Aminosalicylic Acids↗

Effect of patient experience on the results of automated perimetry in clinically stable glaucoma patients.

The first four automated visual field examinations of 20 patients with clinically stable chronic open-angle glaucoma who had previously undergone manual perimetry were studied for the presence of a learning effect on mean sensitivity, number of disturbed test locations, total loss, and short-term fluctuation. A learning effect, if present, would manifest itself as an improvement in the visual field as patients become more experienced with the test. There was no apparent effect of patient experience on the mean sensitivity, total loss, or the number of disturbed test locations. There was a significant (P less than 0.0001) decrease in short-term fluctuation as measured by the root mean square between the first and second visual field examinations. These results indicate that a learning effect did not play an important role in the clinical interpretation of automated perimetry in patients with glaucoma who have previous experience with manual perimetry. In most cases, it was not necessary to obtain more than one "baseline" examination unless a patient demonstrated unusually high short-term fluctuation or had visual field defects inconsistent with the rest of the clinical examination.

Aged↗

The sliding window correlation procedure for detecting hidden correlations: existence of behavioral subgroups illustrated with aged rats.

We developed the sliding window correlation procedure in order to examine populations for possible heterogeneity in the ways two variables are related with each other. This procedure involves computing correlation coefficients (R) for overlapping successive segments of the covariate scores. The distribution of resulting Rs reveals fluctuations in the degree and direction of R over the sample of ranked scores. This procedure is applied to behavioral data of aged rats, which were rank-ordered according to water maze performance, and correlated with open field exploration and conflict behavior in a light/dark chamber. Results revealed correlation coefficients of varying magnitudes and opposing directions for different segments of the population, which were obscured by overall correlation analysis. E.g. for the superior learners, the Rs were highest between maze learning ability, increased open field exploration and reduced anxiety in the conflict test, whereas for the intermediate learners the Rs were highest for maze learning ability related with reduced exploration and increased anxiety. Thus, the sliding window correlation distribution can be applied in conjunction with overall correlation analysis to provide information about the potential presence and locations of subgroups within a population, especially if overall correlation analysis does not yield significant results.

Aging↗

A simple measure of correlation across time, frequency and space between continuous brain signals.

This paper introduces a simple but systematic method to estimate correlations between the spectral energy of two continuous electrophysiological signals in such a way that it can detect relationships between different frequencies and different latencies. From two series of signals (e.g. electroencephalogram, magnetoencephalogram or local field potentials) recorded from two sites in response to repeated sensory stimulations, the method computes the time-frequency energy of each signal. Then, it computes the Spearman rank order correlation coefficient across all the trials between the energy of the first signal series in one time-frequency region and the energy of the second signal series in a second time-frequency region. The method was designed to analyze interactions between frequency bands, in an effort to describe how the main brain rhythms interact with each other across time and space. It was applied to two simulations and to intracranial electro-encephalogram (EEG) recordings obtained from an epileptic patient performing two verbal discrimination tests (a phonological and a semantic task). It led to the identification of different correlations patterns in the gamma band depending on the level of semantic analysis performed by the patient.

Brain↗

Plaque, gingival health and post-operative sensitivity in titanium inlays and onlays: a randomized controlled clinical trial.

OBJECTIVES: Few clinical data on the use of titanium for restorative appliances are available. The aim of this study was to clinically evaluate titanium restorations compared to gold alloy restorations with regard to plaque, gingival health and post-operative sensitivity. METHODS: In 54 patients, 99 titanium restorations were placed. The control group comprised 56 patients with 96 high gold alloy restorations. The material was chosen by random. Each patient received one or two Class II restorations. Plaque Index (Silness and Löe, 0-3), Gingival Index (Löe and Silness, 0-3), and post-operative sensitivity (1-4, 1=none) were rated at 2 weeks, 3 months, 6 months, 12 months, and 18 months, post-operatively. RESULTS: The mean plaque scores ranged from 0.89 to 0.99 in the titanium group, and from 0.88 to 1.04 in the gold group. The mean gingival scores ranged from 0.91 to 1.07 in the titanium group, and from 0.82 to 0.99 in the gold group. The mean plaque and gingival scores of the titanium and gold group did not differ significantly at any visit (P>0.05). To evaluate post-operative sensitivity, patients with one MOD restoration each were included, resulting in 46 titanium and 44 high gold restored teeth. Mean values of the post-operative sensitivity scores in the titanium group were significantly higher than in the gold group (P<0.05). The restoration material was found to be the dominating variable with regard to post-operative sensitivity, which was not influenced by age, sex and the application of calcium hydroxide liner. CONCLUSIONS: It is concluded that neither higher plaque scores nor adverse effects on gingival health are to be expected in titanium restorations.

Adolescent↗