Evaluation of assay procedures for prediction of passive transfer status in lambs.

OBJECTIVE: To compare 4 assay procedures for prediction of passive transfer status in lambs. ANIMALS: Thirty-one 1-day-old Sardinian lambs. PROCEDURE: Serum IgG concentration was determined by use of single radial immunodiffusion. The following were determined: serum total protein concentration as measured by refractometry (ie, refractometry serum total protein concentration), serum total protein concentration as determined by the biuret method (ie, biuret method serum total protein concentration), serum gamma-globulin concentration as determined by serum protein electrophoresis, and serum gamma-glutamyltransferase (GGT) activity as measured by spectrophotometry. Accuracy of these assays for estimation of serum IgG concentration in 1-day-old lambs was established by use of linear regression analysis. RESULTS: Refractometry serum total protein concentration, biuret method serum total protein concentration, and serum gamma-globulin concentration were closely and linearly correlated with serum IgG concentration. The natural logarithm (ln) of serum GGT activity was closely and linearly correlated with serum IgG concentration (ln). Refractometry serum total protein concentration, biuret method serum total protein concentration, and gamma-globulin concentration accounted for approximately 85%, 91%, and 95% of the variation in serum IgG concentration, respectively. Serum GGT activity (ln) accounted for approximately 92% of the variation in serum IgG concentration (ln). CONCLUSIONS AND CLINICAL RELEVANCE: For prediction of passive transfer status in 1-day-old lambs, serum GGT activity or biuret method serum total protein concentration determination will allow for passive transfer monitoring program development. Immediate refractometry serum total protein concentration determination is beneficial in making timely management and treatment decisions. Serum gamma-globulin concentration determination can be used as a confirmatory test.

Animals↗

Comparison of the techniques of evaluation of urine dilution/concentration in the dog.

The objective of this study was to evaluate the quality of the measurement of dog urine dilution/concentration by comparing osmolality with three methods of specific gravity (USG) measurement, i.e. weighing, refractometry and test strips. In unselected urine samples from 182 dogs there was a better agreement between osmolality and USG determination by refractometry (r = 0.92) than by weighing (r = 0.82) or by test strips (r = 0.27). There was an almost linear relationship between osmolality and USG: osmolality (mOsm/kg) = 36646(34318/38974) x (USGref - 1) + 25(-39/88); calculated osmolality differed from measured osmolality by more than 500 mOsm/kg in only 8 of 181 samples. There was a good agreement between USG determination by weighing and refractometry: USGref = 1.000(0.905/1.095) x USGweighing - 0.0004(-0.0019/0.0027), with a moderate bias. Only 12% of the differences between the two methods exceeded 0.010. Test strip assessment of USG was unreliable because of systematic underestimation and should not be used for dog urine. Refractometry is the best technique for routine evaluation of urine concentration/dilution when osmometry is not available.

Animals↗

Xenon measurement in breathing systems: a comparison of ultrasonic and thermal conductivity methods.

Xenon is an anaesthetic and possibly neuroprotective gas that is impossible to measure using conventional anaesthetic gas analysers. We compared the performance of two commissioned xenon analysers using ultrasonic and thermal conductivity principles against a reference method of laser refractometry. An experimental gas circuit was constructed and xenon concentrations compared over a range of 0-100% in oxygen. Eighty-two paired measurements were made comparing the experimental methods with laser refractometry. The ultrasonic method displayed good agreement with laser refractometry, with a mean difference of - 0.74% and two standard deviation limits of agreement of + 1.08% to - 2.56%. The agreement between laser refractometry and thermal conductivity was poor, the mean difference being - 5.37%, with two standard deviation limits of agreement of + 0.6% to - 11.3%. The ultrasonic method for measuring xenon concentrations can be used in breathing circuits. The thermal conductivity instrument may need further development.

Anesthesia, Closed-Circuit↗

Evaluation of a lateral-flow immunoassay for use in monitoring passive transfer of immunoglobulins in calves.

OBJECTIVE: To determine the predictive ability of a commercially available lateral-flow immunoassay used for determining passive transfer of immunoglobulins in calves. ANIMALS: 204 male Holstein calves ranging from 4 to 8 days old. PROCEDURE: Serum samples were obtained from each calf. Results of refractometry, zinc sulfate turbidity technique, and the lateral-flow immunoassay were determined. Sensitivity, specificity, accuracy, and predictive ability were calculated on the basis of IgG concentrations determined by turbidimetric immunoassay (TIA). RESULTS: Mean IgG concentration in the study was 10.9 mg/ml as determined by TIA. Rate of failure of passive transfer in this study population was 56%. Associations between the values for the refractometry and zinc sulfate turbidity techniques were established by regression analysis. Accuracy for the lateral-flow immunoassay, refractometry, and zinc sulfate turbidity methods was 95, 80, and 73%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: The lateral-flow immunoassay was better at determining the status of passive transfer of immunoglobulins, compared with the refractometry or zinc sulfate turbidity methods. The ability of the lateral-flow immunoassay to provide accurate results should enable clinicians to make immediate management or intervention decisions.

Animals↗

[Urinary specific gravity--comparative measurements using reagent strips and refractometer in 340 morning urine samples].

The specific gravity of urine (SG) indicates the number and weight of solute particles in urine; its measurement is helpful in interpreting proteinuria detected by dipstick tests and in monitoring adequate hydration in patients with nephrolithiasis. Four methods for measuring SG or osmolality of urine are currently available (depression of the freezing-point, urometry, refractometry, cation exchange on a reagent strip). Using a recently developed reagent strip, we have measured SG in morning urines of 340 non-selected outpatients and compared the results with SG measurements by refractometry of the same urines. In 86.2% of all urines, a good positive correlation between SG measured by reagent strip and refractometry was noted (r = 0.913, p = 0.0001). In 13.8% of the urines, however, the SG measured by reagent strip deviated by more than +/- 5 from the value obtained by refractometry; in 90% of these urines, glucosuria (reagent strip values too low or too high), proteinuria (values too high), or bacteriuria/leukocyturia (values too low or too high) could be found. In alkaline urine (pH > 7.0), SG values obtained by reagent strip have to be corrected by +5.

Female↗

Measurement of urinary concentration: a critical appraisal of methodologies.

The measurement of urine concentration provides information concerning the kidney's ability to appropriately respond to variations in fluid homeostasis. It also assists in the interpretation of other tests performed on the same urine specimen. The gold standard of estimating urinary concentration is the measurement of its osmolality; however, this procedure is not readily available to the practicing physician. Therefore, urine concentration is usually determined by measurement of its specific gravity (SG), which provides a fair estimate of urine osmolality. Over the years numerous tests have been developed to measure urine SG in a simple, quick, reliable and easily available method. These tests measure SG either directly (e.g., gravimetry) or by indirect methods (e.g., refractometry and reagent strip). All these tests have certain limitations based on their underlying physical principles. Specific gravity as measured by refractometry is influenced by proteinuria, such that for each 10 g/l protein the SG increases by 0.003. SG is also influenced by glucosuria such that it increases by approximately 0.002 per 10 g/l glucose when compared with urinary osmolality. Unlike osmolality, which is only affected by the number of particles, refractometry is affected by number, mass and chemical structure of the dissolved particles; hence large molecules like radiographic contrast or mannitol will increase SG relative to osmolality. The reagent strip is minimally affected by glucose, mannitol or radiographic contrast. However, it is affected by urinary pH such that only urine in the pH range of 7.0-7.5 can be correctly interpreted. The measurement of SG by reagent strip is based on the ionic strength of the urine and thus is significantly affected by the ionic composition of the urine and by proteins which have an electric charge in solution. In our experience, SG measured by the refractometer is consistently more accurate than the reagent strip. For the clinician who is interpreting urine SG results, it is important to be aware of these limitations and understand the reasons for possible potential errors of each particular method.

Humans↗

Apparent absorption efficiencies of nectar sugars in the Cape sugarbird, with a comparison of methods.

Nectarivore sugar preferences and nectar composition in the Cape Floristic Kingdom (southern Africa) differ from trends reported for analogous systems in America and Europe in that sugarbirds and sunbirds show no aversion to sucrose, which is the dominant nectar sugar in many of their food plants. To elucidate the physiological bases (if any) of nectarivore sugar preferences, we determined apparent sugar absorption efficiencies in a passerine endemic to this region, the Cape sugarbird Promerops cafer. Apparent absorption efficiencies for the three major nectar sugars, sucrose, glucose, and fructose, were extremely high (> 99%), as in other specialized avian nectarivores. Xylose, a pentose sugar recently reported in the nectar of some Proteaceae, was absorbed and/or metabolized inefficiently, with a mean of 47.1% of ingested sugar recovered in cloacal fluid. We did not measure the proportions of xylose that were absorbed and/or metabolized. We also compared three methods of estimating absorption efficiency: (1) measurements of total sugar in cloacal fluid with refractometry, without correction for differences between volumes of ingesta and excreta; (2) the same measurements combined with correction for volume differences; and (3) HPLC analyses quantifying individual sugars in cloacal fluid, with correction for volume differences. Refractometry has been frequently used in previous studies. For all sugars except xylose, method 1 yielded results similar to those obtained with method 2, but the convergence was artifactual, and we do not recommend use of this method. Apparent absorption efficiencies calculated with method 2 underestimated true absorption efficiency, because refractometry measures nonsugar solutes, but this error is biologically significant only when efficiencies are low.

Absorption↗

Refractive index and osmolality of human tears.

Tear osmolality measurement, as a basic index of lacrimal physiology, is technically difficult. We investigated a simple, digital nanoliter technique of critical angle refractive index measurement. After initial comparison of the techniques with aqueous NaCl (0.5 to 1.4%), 3 successive tear samples were obtained from each of 40 normal, noncontact lens wearing subjects, aged 17 to 63 years, for analysis by nanoliter osmometry and digital refractometry. In addition, tear lactoferrin concentration was estimated with the Lactoplate immunoassay. For the range of NaCl concentrations tested, osmolality and refractive index measurements were highly correlated with concentration, and with each other. For 0.9% NaClaq the mean value of osmolality was 292.0 mOsm/kg and refractive index was 1.33419. For human tears average values were found to be: for osmolality, 303.7 +/- 22.9 mOsm/kg; for refractive index, 1.33698 +/- 0.00110; and for lactoferrin level, 1.64 +/- 0.47 mg/ml. No statistically significant correlation was obtained between either refractive index or lactoferrin level and osmolality, but refractive index and lactoferrin level were significantly correlated (r = 0.64, p < 0.001). The high correlation of refractometry and osmolality for aqueous NaCl indicates comparability of the techniques for this solution, but this does not apply to human tears. Unlike tear osmolality, tear refractive index is dependent to a greater extent upon composition, as is suggested by its correlation with lactoferrin level. Therefore, refractometry is not acceptable as a direct alternative to osmometry in the assessment of lacrimal function.

Adolescent↗

Evaluation of a commercially available immunoassay for assessing adequacy of passive transfer in calves.

OBJECTIVE: To evaluate diagnostic utility of a commercially available immunoassay for assessing adequacy of passive transfer of immunity in neonatal calves. DESIGN: Prospective study. ANIMALS: 123 calves. PROCEDURE: Blood and serum samples were obtained from the calves prior to 2 weeks of age. The immunoassay was performed, along with refractometry and an 18% sodium sulfite turbidity test. Serum IgG concentration was determined with a radial immunodiffusion assay. Sensitivity and specificity of the immunoassay, refractometry, and the sodium sulfite test were calculated by comparing results with results of the radial immunodiffusion assay. RESULTS: Sensitivity and specificity of the blood IgG immunoassay were 0.93 and 0.88, respectively, compared with 1.00 and 0.53 for the sodium sulfite test. For refractometry, sensitivity and specificity were 0.71 and 0.83, respectively, when a serum total solids concentration of 5.2 g/dl was used as the cutoff between positive and negative test results. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that the immunoassay performs well in detecting calves with inadequate passive transfer of immunity.

Animals↗

[Evaluation of a test strip for the determination of urine specific gravity in the dog].

The specific gravity of 80 randomly chosen urine samples from healthy dogs without polyuria/polydipsia and from a few dogs with polyuria/polydipsia was measured by refractometry and by test strip method (sg test strip). Urine osmolality and pH were also measured and the urine samples were examined for the presence of glucose. In accordance with earlier observations, there was an excellent correlation between the specific gravity determined by refractory and the osmolality (r = 0.98). The results obtained with the sg test strip correlated poorly with those obtained by refractometry (r = 0.39) and poorly with the osmolality (r = 0.36). In 77.5% of the samples the specific gravity determined with the sg test strip differed by more than 0.005 from that determined by refractometry. After correction of the sg test strip results by +0.005 for urine pH > or = 6.5, this percentage decreased to 60%. The results for the refractometer and sg test strip were significantly different (P < 0.001). These results indicate that the sg test strip investigated is unsuitable for use to determination of the specific gravity of canine urine.

Animals↗

A comparison of analytic procedures for measurement of fractional dextran clearances.

Fractional dextran clearances have been extensively used to study glomerular size selectivity. We report on an analysis of different laboratory procedures involved in measuring fractional dextran clearances. The deproteinization of plasma samples by 20% trichloroacetic acid (TCA) revealed a protein contamination of 0.2% +/- 0.3%, whereas both 5% TCA and zinc sulfate deproteinization revealed a significantly higher remaining sample protein content (2.5% +/- 0.4% and 3.4% +/- 0.1%, respectively). Only zinc sulfate revealed incomplete deproteinization of urine samples (0.6% +/- 0.2%). Dextran recovery in plasma and urine supernatants was significantly lower after 5% TCA and zinc sulfate deproteinization when compared with 20% TCA deproteinization. Gel permeation chromatography (GPC) and high-performance liquid chromatography (HPLC) showed a variance of calibration smaller than 5% over 1 year. The use of 3 different sets of standard dextrans revealed significant differences in calibration. GPC and HPLC followed by anthrone assay showed a comparable variance in dextran concentration in plasma, from 3 to 6 nm (14% to 25%), whereas the variance in urine was lower for the GPC and anthrone assay, especially from 5.4 to 6 nm (23% to 43% versus 50% to 78%). HPLC and online refractometry showed the lowest variance of dextran concentration in plasma, from 3 to 6 nm (<4%), and in urine, from 3 to 5.2 nm (<7%), whereas it showed a higher variance in urine, from 5.4 to 6 nm, in comparison with GPC and HPLC with the anthrone assay. The GPC and anthrone assay revealed higher fractional dextran clearances in comparison with the HPLC and anthrone assay in healthy subjects (3 to 5.4 nm) as well as in patients with nondiabetic proteinuria (4.2 to 5.8 nm), and lower clearances in patients from 3 to 3.4 nm. The HPLC and anthrone assay revealed higher clearances in comparison with HPLC and online refractometry in healthy subjects (3.6 to 5.4 nm) and in patients (3.6 to 5.2 nm). The GPC and anthrone assay revealed characteristic differences in fractional dextran clearances between healthy subjects and patients. The HPLC and anthrone assay showed no significant differences between both groups, whereas HPLC and online refractometry showed only an increased clearance of dextrans from 4.6 to 5.2 nm in patients. Fractional clearances of dextran 5.6 nm as estimated by all 3 dextran assays were not significantly related to the fractional immunoglobulin G clearance or the immunoglobulin-to-albumin clearance index in our patients. Quantitative and qualitative differences in fractional dextran clearances may be induced by differences in laboratory procedures. We recommend sample preparation by 20% TCA deproteinization, frequent calibration with 1 set of dextran standards with low polydispersity, size-exclusion chromatography by GPC, and dextran detection by anthrone assay for optimal measurement of fractional dextran clearances. Even with such an approach, however, the variability in the measurement remains extremely high in the important range of dextrans greater than 5 nm.

Chromatography, Gel↗

Refractive index and equilibrium water content of conventional and silicone hydrogel contact lenses.

PURPOSE: The purpose of the present study was to measure equilibrium water content (EWC) and refractive index of conventional and silicone hydrogel soft contact lenses (SCL) using a hand refractometer and an automated refractometer. METHODS: Sixteen SCL were used in this study including 12 conventional SCL not containing siloxane moieties (equilibrium water content (EWC) range: 38.6-74%) and the four silicone hydrogel based contact lenses currently available (WC range: 24-47%). Two experienced observers performed the measurements in a randomised order being masked by a third party during the three sessions at which the measurements were collected. The Atago N-2E hand refractometer and the CLR 12-70 digital refractometer were used. Data were analysed separately for conventional and silicone hydrogel materials. RESULTS: Measured EWC and refractive index correlate better when measured with the instruments used in this study (r(2) = 0.979, p < 0.001) than the nominal parameters (r(2) = 0.666, p < 0.001). The linear relationship that correlates nominal and measured EWC shows higher spread of data when all lenses are analysed together (r(2) = 0.840) than when conventional hydrogel (r(2) = 0.953) and silicone hydrogel contact lenses (r(2) = 0.967) are analysed separately. Regarding refractive index, the relationship between nominal and measured values when all the lenses are considered together (r(2) = 0.794) becomes weaker when conventional hydrogel are considered separately (r(2) = 0.688), while a stronger relationship is observed for silicone hydrogel lenses (r(2) = 0.939). Hence, hand refractometry overestimates the EWC of silicone hydrogels, while automated refractive index measurements are more accurate in silicone hydrogels than in conventional hydrogels. CONCLUSIONS: New relationships are presented that correlate nominal and measured values of EWC and refractive index for the silicone containing hydrogels. The linear relationships derived fit well to the data. Hand refractometry overestimates the EWC of silicone hydrogel materials and this bias is related to the proportion of siloxane moieties in the material. Conversely, refractive index can be obtained more accurately with automated refractometry for silicone hydrogels than for conventional hydrogels. Present results are of interest in planning future clinical studies involving the measurement of EWC of current hydrogels.

Contact Lenses, Hydrophilic↗

Refractive indices for volatile anesthetic gases: equipment and method for calibrating vaporizers and monitors.

OBJECTIVE: The objective of our study was to establish the refractive indices and the virial coefficients of the volatile anesthetic vapors. These indices and coefficients will allow refractometry to be used by manufacturers to produce accurate calibration, without requiring expensive high-precision calibration gases. METHODS: We used a precision refractometer to measure the refractive indices for five volatile anesthetic vapors. We prepared our calibration gases by mixing a gravimetrically calibrated amount of liquid agent with a constant gas flow. RESULTS: The refractive indices for the volatile anesthetic vapors are 1,603.2 for halothane, 1,540.4 for enflurane, 1,563.3 for isoflurane, 1,538.3 for sevoflurane, and 1,211.7 for desflurane. The maximum theoretical error in our measurements, due to all sensors and all uncertainty in our measurement of apparatus and physical constants, is +/- 0.56% of the reading (+/- 0.70% for desflurane). CONCLUSIONS: If refractometry replaced calibration gases in cylinders, as a calibration standard, manufacturers might avoid errors that now occur because calibration gases manufactured by numerous companies seem to differ. We propose that our values serve as an interim database.

Anesthesia, Inhalation↗

Small amounts of urea and guanidine hydrochloride can be detected by a far-UV spectrophotometric method in dialysed protein solutions.

The quantization of small amounts of chemical denaturants as urea or guanidine hydrochloride in protein solutions after dialysis is a difficult task in the molecular biology laboratory practice. Refractometric methods are useful to quantify a denaturant in the molar range but this methodology is not helpful when the denaturant is present in small amounts. The method herein described is a new comparative method that requires, a priori, the quantification of the stock solutions of urea (8 M) and guanidine hydrochloride (6 M) by refractometry to prepare by sequential dilution the standards used for comparison in the spectropolarimeter. The method is based on the observation that the wavelengths, at which the absorbance of polarized light increases in the far-UV region, as observed by spectropolarimetry, is related to the concentration of the chemical denaturant present in the protein solution. In the quantitation method herein reported, the urea and guanidine hydrochloride detection limits range from 1.2 x 10(-4) to 6 x 10(-6) M depending on the protein dialysis buffer used for a standard cell path length of 1 cm. The sensibility of this method results to be comprised in a range 4-5 orders of magnitude higher than that measured by refractometry. The determinations in both the sample and the control preparations are virtually completed within approximately 10 min.

Complex Mixtures↗

Dipstick measurements of urine specific gravity are unreliable.

AIM: To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG). METHODS: Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three different methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick). RESULTS: The correlations between the visual U-SG dipstick measurements and U-SG determined by a refractometer and the comparison of Clinitek((R))-50 dipstick U-SG measurements with U-Osm were less than optimal, showing very wide scatter of values. Only the U-SG refractometer values and U-Osm had a good linear correlation. The tested dipstick was unreliable for the bedside determination of U-SG, even after correction for U-pH, as recommended by the manufacturer. CONCLUSIONS: Among the bedside determinations, only refractometry gives reliable U-SG results. Dipstick U-SG measurements should be abandoned.

Humans↗

Monitoring bolus nasogastric tube feeding by the Brix value determination and residual volume measurement of gastric contents.

BACKGROUND: Critically ill patients do not always tolerate nasogastric tube feeding. Gastric residual volumes (GRVs), obtained by aspiration from a nasogastric tube, are widely used to evaluate feeding tolerance and gastric emptying, but controversy exists about what constitutes the true GRV (diet formula or digestive juice) and how it should affect management. In this pilot study, we used the Brix value (BV) measurement of gastric contents to monitor both GRV and food content in patients receiving nasogastric feeding. METHODS: Forty-three patients receiving bolus nasogastric feeding were monitored for 24 hours before entry into the study and then divided into 2 groups according to traditional use of GRV; patients with low GRVs (< 75 mL) were placed in group 1, whereas patients with higher GRVs (> 75 mL) were placed in group 2. All subjects were given 250 mL of polymeric formula by bolus nasogastric infusion, followed by BV measurement of gastric contents at 0, 30, 60, 120, and 180 minutes. All gastric fluid was aspirated after 180 minutes of feeding; the volume was recorded and BV measurement made, then reinstilled with an added 30 mL of dilutional water, after which a final aspiration and BV measurement was performed. Calculated GRV and volume of formula remaining in the stomach was determined by derived equations. RESULTS: Serial BV measurements decreased in both groups after bolus feeding. For patients in group 2, the decrease was less such that at 180 minutes, the mean BV for gastric contents was significantly higher than for those patients in group 1 (10.1 vs 5.1, respectively; p < .01). Aspirated GRV, calculated GRV, and volume of formula remaining in the stomach at 180 minutes were significantly greater for patients in group 2 compared with those in group 1. Use of refractometry in combination with traditional use of GRV identified 4% (1/25) of patients in group 1 with low GRVs who might have possible gastric dysmotility (> 20% of initial 250-mL volume of formula remaining at 180 minutes) and ensured that 72% (13/18) of patients in group 2 with higher GRVs had sufficient gastric emptying (< 20% of initial 250 mL volume of formula remaining). CONCLUSION: This pilot study raises the feasibility that refractometry and the BV measurement of gastric juice may be a promising tool for bedside monitoring of tolerance and gastric emptying in patients receiving nasogastric feeding, providing valuable complementary information to traditional use of GRV.

Adult↗

Urine specific gravity measurements: comparison of a new reagent strip method with existing methodologies, as applied to the water concentration/dilution tests.

A study was carried out to compare a new, unique chemical strip test for the measurement of urine specific gravity with the traditional methods of hydrometry and refractometry, during water concentration/dilution tests in 12 normal subjects. The pattern of specific gravity results during these serial measurements was virtually identical for the strip and for the comparative methods. Comparison of the strip results with those obtained by both hydrometry and refractometry produced acceptable linear regression data. In addition, a close relationship was demonstrated between the strip specific gravity and urine osmolality. The findings show that the strip method is an acceptable alternative to traditional methods as an indicator of urine concentration.

Adult↗

Comparison of four methods for determination of total protein concentrations in pleural and peritoneal fluid from dogs.

OBJECTIVE: To compare 4 techniques for determination of total protein concentrations in peritoneal and pleural effusions from dogs. SAMPLE POPULATION: 23 peritoneal and 12 pleural fluid samples from 35 dogs with various abnormalities. PROCEDURE: Samples were collected into tubes containing EDTA, centrifuged, and stored at -20 C until total protein concentrations were assessed. Protein concentration in each sample was determined by use of urine test strips, refractometry, and Bradford and biuret techniques. Accuracy of each method was determined, using dilutions of human control sera. RESULTS: There was good correlation among results of all quantitative procedures. Results of the biuret technique were more accurate than results of the Bradford assay. Refractometry underestimated protein concentration in samples with < 20 g of protein/L. Results of urine test strips correctly classified effusion samples into 2 groups on the basis of total protein concentrations less than or greater than 20 g/L. CONCLUSIONS AND CLINICAL RELEVANCE: Results of any of these 4 techniques can be used to rapidly and efficiently differentiate peritoneal and pleural fluid from dogs into transudates and exudates on the basis of total protein concentration less than or greater than 20 g/L, respectively.

Animals↗