[Optimization of pulse sequences for MR cholangiopancreatography with FASE].

Various types of pulse sequences for MR cholangiopancreatography (MRCP) have been developed in the past ten years. FASE (fast advanced spin echo) is one of the single-shot fast spin-echo sequences developed by Toshiba. By using this sequence, 2D single slice, 2D multiple slice and 3D methods can be provided. We routinely employ 2D single slice and 3D methods. The merit of 2D single slice method is conveniently obtained projection imaging within short data acquisition time. On the other hand, 3D method can yield detailed evaluation of various anatomical structures and abnormalities by using thin-slice source images. O2-inhalation study is especially recommended in case of 3D method. With the proper knowledge of sequence characteristics, MRCP using FASE can provide valuable informations of pancreatico-biliary diseases.

Biliary Tract↗

Fast T2-weighted MR imaging: impact of variation in pulse sequence parameters on image quality and artifacts.

The purpose of this study was to quantitatively evaluate in a phantom model the practical impact of alteration of key imaging parameters on image quality and artifacts for the most commonly used fast T(2)-weighted MR sequences. These include fast spin-echo (FSE), single shot fast spin-echo (SSFSE), and spin-echo echo-planar imaging (EPI) pulse sequences. We developed a composite phantom with different T1 and T2 values, which was evaluated while stationary as well as during periodic motion. Experiments involved controlled variations in key parameters including effective TE, TR, echo spacing (ESP), receive bandwidth (BW), echo train length (ETL), and shot number (SN). Quantitative analysis consisted of signal-to-noise ratio (SNR), image nonuniformity, full-width-at-half-maximum (i.e., blurring or geometric distortion) and ghosting ratio. Among the fast T(2)-weighted sequences, EPI was most sensitive to alterations in imaging parameters. Among imaging parameters that we tested, effective TE, ETL, and shot number most prominently affected image quality and artifacts. Short T(2) objects were more sensitive to alterations in imaging parameters in terms of image quality and artifacts. Optimal clinical application of these fast T(2)-weighted imaging pulse sequences requires careful attention to selection of imaging parameters.

Artifacts↗

Pulse sequences for interventional magnetic resonance imaging.

Interventional magnetic resonance imaging (iMRI) is different from diagnostic magnetic resonance imaging (MRI) in its spatial, temporal, and contrast resolution requirements due to its specific clinical applications. As a result, the pulse sequences used in iMRI often are significantly different than those used in the more conventional diagnostic arena. The focus of this article is to summarize how iMRI is different from diagnostic MRI, to describe a variety of MRI pulse sequences and sequence strategies that have evolved because of these differences, and to describe some MRI sequence strategies that are in development and may be seen in future iMRI applications.

Body Temperature↗

Contrast-enhanced MRI of the menisci of the knee using ultrashort echo time (UTE) pulse sequences: imaging of the red and white zones.

The objective of this study was to demonstrate the red and white zones of the meniscus of the knee using MRI. Ultrashort echo time (UTE) pulse sequences with an initial TE of 0.08 ms and later echoes at 5.95 ms, 11.08 ms and 17.70 ms were used to image the meniscus of the knee in two normal subjects before and after intravenous administration of gadodiamide. Difference images were formed by subtraction of later echo images from the first. The difference images showed obvious enhancement in an area consistent in location and dimensions with the red zone of the meniscus. Regions of interest placed within this area, central to it (corresponding to the white zone), and peripheral to it (corresponding to perimeniscal tissue) all showed increases in signal intensity after intravenous contrast administration. The greatest change in signal intensity in these regions of interest was seen with the shortest TE and in perimeniscal tissue on the original images. The increase in signal intensity was greatest in the red zone on the difference images. Using UTE pulse sequences and difference images derived from them, it is possible to visualize enhancement selectively in the red zone of the meniscus. Less obvious but significant changes in signal intensity were also present in the white zone.

Adult↗

[Comparison of susceptibility artefacts of different radiofrequency electrodes at O.2 T. Influence of electrode positioning, pulse sequence and image reconstruction methods].

PURPOSE: Interventional MRI procedure monitoring requires small but accurate susceptibility artifacts of the instruments used. In this investigation, susceptibility artifacts of different RF-electrode designs were compared using a variety of pulse sequences and k-space acquisition methods. METHODS: 4 different 18-gauge RF-electrodes (with three single electrodes made of stainless steel, copper, inconal, and a triple-clustered electrode configuration made of inconal) were placed in a 0.2 T MR-scanner perpendicular to the main magnetic field. Pulse sequences used included: TSE T2, FISP, true-FISP, PSIF, and a temperature sensitive ES-GRE sequence. In addition to the 2D Cartesian k-space trajectory with Fourier transformation (2DFT), projection reconstruction (PR) was used with the FISP, true-FISP and PSIF sequences. RESULTS: The best tip accuracy was achieved with the combination of inconal electrodes and TSE T2. The usefulness of the tested sequences was found to be: TSE T2 > PSIF > FISP/true-FISP > ES-GRE. In general 2DFT provided better or equal tip accuracy than PR. The apparent shaft width was smaller using the copper electrode compared to the inconal electrode. However, the "match shaped" tip artifact of the copper probe led to a higher error in tip accuracy. CONCLUSIONS: TSE-T2 sequences and Cartesian 2DFT acquisitions should be used for accurate tip positioning at 0.2 T. Further, artifact size of the electrode shaft prevents the use of inconal for temperature sensitive sequences. Copper electrodes can be used for these purposes, although copper is not considered to be biocompatible at present.

Artifacts↗

Optimal pulse sequence for imaging hepatic metastases.

For magnetic resonance (MR) imaging studies in which the diagnosis is dependent on image contrast, it is essential that an optimized imaging technique be used. Using detection of hepatic metastases as an example, the authors describe a rational strategy for optimizing MR imaging technique. First, for a single patient with proved hepatic metastases, a variety of imaging sequences is discussed and evaluated, leading to characterization of the patient's hepatic tissues. Then the characteristics of the tissues of a representative patient population are presented. These are used to determine two optimal pulse sequences that maximize the achievable signal difference-to-noise ratio achievable in a fixed imaging time. The recommended imaging sequence for detection of hepatic metastases at 0.15 T is either a three-dimensional volume spin-echo (SE) sequence with echo time (TE) = 12 msec and repetition time (TR) = 184 msec or a multisection inversion recovery sequence with TE = 22 msec, inversion time = 250 msec, and TR = 1,375 msec. The variation of this optimum pulse sequence with field strength is also presented.

Humans↗

Practical choices of fast spin echo pulse sequence parameters: clinically useful proton density and T2-weighted contrasts.

With the development of fast spin echo (FSE) MRI techniques, T2-weighted images of the brain may be obtained much more quickly than when using conventional spin echo techniques (CSE), because made the individual echoes on the FSE pulse sequence are phase encoded, allowing acquisition of the same spatial information as in CSE with less excitations. The pulse sequence parameters (echo train length, bandwidth, echo spacing) are discussed. Images were obtained on four volunteers using both CSE and FSE while varying repetition time, echo time and matrix. Comparison for signal intensity gray-white differentiation, fat and CSE signal, arifacts and vascular resolution showed that FSE images comparable in quality to those of CSE can be obtained in less than half the time. A practical choice of FSE parameters is recommended for clinical use. However, artifacts, possibly related to CSF and vascular pulsation, of which the radiologist should be aware, were identified on the FSE images.

Artifacts↗

Comparison of different pulse sequences for in vivo determination of T1 relaxation times in the human brain.

Quantitative in vivo determination of T1 relaxation times by magnetic resonance imaging (MRI) is hampered by several potential sources of error. This study focused on the influence of the radiofrequency pulse sequences applied with special attention to the significance of the repetition time (TR). T1 measurements were performed on the human brain using a whole body MR scanner operating at 1.5 tesla. Three different pulse sequences were compared including two 6-points inversion recovery (IR) sequences with TR = 2.0 s and 4.0, respectively, and a 12-points partial saturation inversion recovery (PSIR) sequence with TR varying between 0.24 and 8.0 s. The median T1 relaxation times obtained in cortical grey matter and cerebrospinal fluid were significantly shorter in the IR experiments at TR = 2 s than in those carried out at TR = 4 s. Concerning white matter the discrepancy was much less pronounced, but still statistically significant. Supplementary phantom measurements indicated that the higher T1 values are increasingly underestimated when TR is reduced to 2 s. The results suggest that the PSIR sequence or IR sequences with a TR greater than 2 X the T1 level of the tissue type investigated should be employed for accurate T1 determination by MRI in clinical work.

Brain↗

How much contrast is enough?. Dependence of enhancement on field strength and MR pulse sequence.

The overwhelming majority of published studies defining the clinical utility of gadolinium administration for neuroimaging have been performed at high field using conventional spin-echo imaging. Concerning the issue of field strength, several investigations have now shown that for a given dose of contrast, enhancement is less apparent at low field than at high field. Concerning the issue of pulse sequence, there is now convincing clinical and experimental evidence that all T1-weighted sequences are not equal in demonstrating contrast enhancement. Specifically, T1-weighted spoiled gradient-echo sequences do not show the same degree of visually apparent contrast enhancement compared to conventional spin-echo sequences. The use of magnetization transfer techniques which demonstrate areas of enhancement unseen on conventional pulse sequences is also addressed.

Brain↗

Detection of hepatic VX2 carcinomas with ferucarbotran-enhanced magnetic resonance imaging in rabbits: Comparison of nine pulse sequences.

OBJECTIVE: To compare the diagnostic performance of a variety of magnetic resonance imaging (MRI) sequences, in order to identify the most effective ferucarbotran-enhanced sequence for the detection of multiple small hepatic VX2 carcinomas in rabbits. METHODS: Fifteen rabbits with experimentally induced 135 VX2 carcinomas in the liver underwent ferucarbotran-enhanced MRI using the following nine pulse sequences: a fat-suppressed fast spin-echo (FSE) sequence with two echo times (TE) (proton density- and T2-weighted images), four different T2*-weighted fast multiplanar GRASS (gradient-recalled acquisition in the steady state) (FMPGR) with the combination of three TEs (9, 12, 15 ms, respectively) and two flip angles (20 degrees , 80 degrees, respectively), T2*-weighted fast multiplanar spoiled GRASS (FMPSPGR), T1-weighted FMPSPGR, and dynamic T1-weighted FMPSPGR. All images were reviewed by three radiologists with quantitative and qualitative analysis. RESULTS: Tumor-to-liver contrast-to-noise ratio of the proton density-weighted FSE sequence was significantly higher than those of the others (p<0.05). The lesion conspicuities of proton density- and T2-weighted FSE and T2*-weighted FMPGR (TE/flip angle, 9/20 degrees and 12/20 degrees ) images were better and the image artifacts of T2*-weighted FMPGR (TE/flip angle, 15/20 degrees and 12/80 degrees ) and T2*-weighted FMPSPGR images were more prominent than those of the others (p<0.05). The lesion detection in T2- and proton density-weighted FSE and T2*-weighted FMPGR (TE/flip angle, 12/20 degrees ) images were superior to those of the others and for the detection of very small hepatic tumors of less than 5 mm, the sensitivities of these sequences were less than 30%. CONCLUSION: Ferucarbotran-enhanced T2- and proton density-weighted FSE and T2*-weighed FMPGR (TE/flip angle, 12/20 degrees ) images were found to be the most effective pulse sequences for the detection of multiple small hepatic VX2 carcinomas but these sequences were limited in the detection of very small hepatic tumors of less than 5 mm in size.

Animals↗

Using a "non uniform pulse sequence" can improve selective coagulation with a Nd:YAG laser (1.06 microm) thanks to Met-hemoglobin absorption: a clinical study on blue leg veins.

BACKGROUND AND OBJECTIVES: Evaluation of the efficacy, on 1-2 mm blue leg telangiectasia, of a 1,064 nm Nd:YAG laser emitting in a non uniform pulse sequence calculated to consider Met-Hb formation during laser irradiation of a blood vessel. MATERIALS AND METHODS: A 1,064 nm Nd:YAG laser (Quantel Medical, Athos, France) was used in a non uniform pulse sequence mode, fluences: 300-360 J/cm(2) spot: 2 mm, + 5 degrees C contact cooling. The clinical evaluation was performed on 11 female patients, average age: 43 (25-57) years, phototype I-VI. All subjects were previously examined with Doppler ultrasound. A treatment site (6 x 4 cm) was selected on each patient. The topography of the vessels network was reported on a tracing plastic frame before each session and 6 weeks after the last one. These frames were digitized and the number of vessels was determined using the Digitized Tracing Frames Technique. Side effects were noted before and after every treatment, and 6 weeks after the last one. This study lasted for 10 months. RESULTS AND DISCUSSIONS: Patients tolerated the procedure without anesthesia. Moderate pain, transient erythema and edema, one hyperpigmentation and one matting were noted. There was no hypopigmentation. 55% (P < 0.002) vessels clearance after one session, 86% after two sessions (P < 0.001), and 98% (P < 0.001) after three sessions were obtained. On two patients, the treatment was completed after two sessions with a full clearance. Data reported in this study were obtained thanks to a computerized calculation of vessels clearance. They are similar or superior to those reported in the literature about 1,064 nm Nd:YAG lasers and leg telangiectasia. CONCLUSIONS: Since, it was developed to consider the modification of blood absorption and the methemoglobin formation which leads to an increase of the 1.06 microm wavelength absorption, the non uniform pulse mode emphasizes the efficacy of this 1,064 nm Nd:YAG laser concerning the treatment of blue leg veins telangiectasia between 1 and 2 mm. This mode gives the possibility to deliver high energy while preserving the surrounding tissue and leads to a rapid vessel clearance with reduced pain and few side effects when compared to previously published clinical studies using a 1.06 microm laser.

Adult↗

A study of homonuclear dipolar recoupling pulse sequences in solid-state nuclear magnetic resonance.

Dipolar recoupling pulse sequences are of great importance in magic angle spinning solid-state NMR. Recoupling sequences are used for excitation of double-quantum coherence, which, in turn, is employed in experiments to estimate internuclear distances and molecular torsion angles. Much effort is spent on the design of recoupling sequences that are able to produce double-quantum coherence with high efficiency in demanding spin systems, i.e., spin systems with small dipole-dipole couplings and large chemical-shift anisotropies (CSAs). The sequence should perform robustly under a variety of experimental conditions. This paper presents experiments and computer calculations that extend the theory of double-quantum coherence preparation from the strong coupling/small CSA limit to the weak coupling limit. The performance of several popular dipole-dipole recoupling sequences-DRAWS, POST-C7, SPC-5, R1, and R2-are compared. It is found that the optimum performance for several of these sequences, in the weak coupling/large CSA limit, varies dramatically, with respect to the sample spinning speed, the magnitude and orientation of the CSAs, and the magnitude of dipole-dipole couplings. It is found that the efficiency of double-quantum coherence preparation by gamma-encoded sequences departs from the predictions of first-order theory. The discussion is supported by density-matrix calculations.

Alanine↗

Use of fluid attenuated inversion recovery (FLAIR) pulse sequences in MRI of the brain.

Fluid attenuated inversion recovery pulse sequences with a long echo time (TE) have been used to image the brain in one volunteer and four patients. The long inversion time used with this sequence suppresses the signal from CSF and the long TE produces very heavy T2 weighting. The marked reduction in flow artefact from CSF and the high T2 weighting enabled anatomical detail to be seen within the brain stem and produced high lesion contrast in areas close to CSF. Lesions were demonstrated with greater conspicuity than with conventional T2-weighted sequences in patients with cerebral infarction, low grade astrocytoma, and diplegia.

Adolescent↗

Cervical spine: MR imaging with a partial flip angle, gradient-refocused pulse sequence. Part II. Spinal cord disease.

A magnetic resonance imaging pulse sequence (GRASS) with a short repetition time (TR), short echo time (TE), partial flip angle, and gradient refocused echo was prospectively evaluated for the detection of cervical cord disease that caused minimal or no cord enlargement in eight patients. Sagittal T2-weighted, cerebrospinal fluid (CSF)-gated images and sagittal and axial GRASS images were obtained in all patients. The following GRASS parameters were manipulated to determine their effect on signal-to-noise ratio (S/N) and contrast: flip angle (4 degrees-18 degrees), TR (22-50 msec), and TE (12.5-25 msec). Flip angle had the greatest effect on S/N and contrast. There were no differences between axial and sagittal imaging for the spinal cord or lesion. However, because the signal intensity of CSF did differ on sagittal and axial images and because this influenced the conspicuity of lesions, there was a difference in the useful flip angle range for axial and sagittal imaging. No one set of imaging parameters was clearly superior, and in all patients, the gated image was superior to the sagittal GRASS image in lesion detection. GRASS images should be used in the axial plane primarily to confirm spinal cord disease detected on sagittal CSF-gated images. For this, a balanced approach is suggested (TR = 40 msec, TE = 20 msec, with flip angles of 4 degrees-6 degrees for sagittal and 6 degrees-8 degrees for axial imaging).

Humans↗

Minimization of dead-periods in MRI pulse sequences for imaging oblique planes.

With the advent of breath-hold MR cardiac imaging techniques, the minimization of TR and TE for oblique planes has become a critical issue. The slew rates and maximum currents of gradient amplifiers limit the minimum possible TR and TE by adding dead-periods to the pulse sequences. We propose a method of designing gradient waveforms that will be applied to the amplifiers instead of the slice, readout, and phase encoding waveforms. Because this method ensures that the gradient amplifiers will always switch at their maximum slew rate, it results in the minimum possible dead-period for given imaging parameters and scan plane position. A GRASS pulse sequence has been designed and ultra-short TR and TE values have been obtained with standard gradient amplifiers and coils. For some oblique slices, we have achieved shorter TR and TE values than those for nonoblique slices.

Algorithms↗

Improving pulse sequences for 3D diffusion-ordered NMR spectroscopy: 2DJ-IDOSY.

An improved pulse sequence for the 3D DOSY experiment 2DJ-DOSY, using diffusion encoding internal to the parent 2DJ spectroscopy sequence (2DJ-IDOSY), is presented. The diffusion-encoding pulses are used to enforce the desired coherence transfer pathway, reducing the minimum experimental time by at least a factor of 4, as compared to existing techniques, and approximately doubling the signal-to-noise ratio for small molecules. The new sequence is demonstrated on a simple mixture and on a complex sample with a high dynamic range (port wine). The principle of internal diffusion encoding can be applied with profit to a range of other 3D DOSY experiments.

Journal Article↗

Biomedical imaging using hyperpolarized noble gas MRI: pulse sequence considerations.

Hyperpolarized noble gas MRI is a new technique for imaging of gas spaces and tissues that have been hitherto difficult to image, making it a promising diagnostic tool. The unique properties of hyperpolarized species, particularly the non-renewability of the large non-equilibrium spin polarization, raises questions about the feasibility of hyperpolarized noble gas MRI methods. In this paper, the critical issue of T1 relaxation is discussed and it is shown that a substantial amount of polarization should reach the targets of interest for imaging. We analyse various pulse sequence designs, and point out that total scan times can be decreased so that they are comparable or shorter than tissue T1 values. Pulse sequences can be optimized to effectively utilize the non-renewable hyperpolarization, to enhance the SNR, and to eliminate image artifacts. Hyperpolarized noble gas MRI is concluded to be quite feasible.

Echo-Planar Imaging↗

Homonuclear Hartmann-Hahn transfer with reduced relaxation losses by use of the MOCCA-XY16 multiple pulse sequence.

Homonuclear Hartmann-Hahn transfer is one of the most important building blocks in modern high-resolution NMR. It constitutes a very efficient transfer element for the assignment of proteins, nucleic acids, and oligosaccharides. Nevertheless, in macromolecules exceeding approximately 10 kDa TOCSY-experiments can show decreasing sensitivity due to fast transverse relaxation processes that are active during the mixing periods. In this article we propose the MOCCA-XY16 multiple pulse sequence, originally developed for efficient TOCSY transfer through residual dipolar couplings, as a homonuclear Hartmann-Hahn sequence with improved relaxation properties. A theoretical analysis of the coherence transfer via scalar couplings and its relaxation behavior as well as experimental transfer curves for MOCCA-XY16 relative to the well-characterized DIPSI-2 multiple pulse sequence are given.

Algorithms↗