Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PIPET”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Apparent viscosity and cortical tension of blood granulocytes determined by micropipet aspiration.

Continuous deformation and entry flow of single blood granulocytes into small caliber micropipets at various suction pressures have been studied to determine an apparent viscosity for the cell contents and to estimate the extent that dissipation in a cortical layer adjacent to the cell surface contributes to the total viscous flow resistance. Experiments were carried out with a wide range of pipet sizes (2.0-7.5 microns) and suction pressures (10(2)-10(4) dyn/cm2) to examine the details of the entry flow. The results show that the outer cortex of the cell maintains a small persistent tension of approximately 0.035 dyn/cm. The tension creates a threshold pressure below which the cell will not enter the pipet. The superficial plasma membrane of these cells appears to establish an upper limit to surface dilation which is reached after microscopic "ruffles" and "folds" have been pulled smooth. With aspiration of cells by small pipets (less than 2.7 microns), the limit to surface expansion was derived from the maximal extension of the cell into the pipet; final areas were measured to be 2.1 to 2.2 times the area of the initial spherical shape. For suctions in excess of a threshold, the response to constant pressure was continuous flow in proportion to excess pressure above the threshold with only a small nonlinearity over time until the cell completely entered the pipet (for pipet calibers greater than 2.7 microns). With a theoretical model introduced in a companion paper, (Yeung, A., and E. Evans., 1989, Biophys. J. 56:139-149) the entry flow response versus pipet size and suction pressure was analyzed to estimate the apparent viscosity of the cell interior and the ratio of cortical flow resistance to flow resistance from the cell interior. The apparent viscosity was found to depend strongly on temperature with values on the order of 2 x 10(3) poise at 23 degrees C, lower values of 1 x 10(3) poise at 37 degrees C, but extremely large values in excess of 10(4) poise below 10 degrees C. Because of scatter in cell response, it was not possible to accurately establish the characteristic ratio for flow resistance in the cortex to that inside the cell; however, the data showed that the cortex does not contribute significantly to the total flow resistance.

Granulocytes↗

Bending elastic modulus of red blood cell membrane derived from buckling instability in micropipet aspiration tests.

Observation of cell membrane buckling and cell folding in micropipette aspiration experiments was used to evaluate the bending rigidity of the red blood cell membrane. The suction pressure required to buckle the membrane surface initially was found to be about one-half to two-thirds of the pressure that caused the cell to fold and move up the pipet. A simple analytical model for buckling of a membrane disk supported at inner and outer radii correlates well with the observed buckling pressures vs. pipet radii. The buckling pressure is predicted to increase in inverse proportion to the cube of the pipet radius; also, the buckling pressure depends inversely on the radial distance to the toroidal rim of the cell, normalized by the pipet radius. As such, the pressure required to buckle the membrane with 1 X 10(-4) cm diam pipet would be about four times greater than with a 2 X 10(-4) cm pipet. This is the behavior observed experimentally. Based on analysis of the observed buckling data, the membrane bending or curvature elastic modulus is calculated to be 1.8 X 10(-12) dyn-cm.

Elasticity↗

Giant lipid vesicles impaled with glass microelectrodes: GigaOhm seal by membrane spreading.

Giant unilamellar lipid vesicles could be perfect systems to study ion channels in the environment of lipid membranes with defined chemical and physical properties. Prerequisite for electrical measurements is an intravesicular electrical contact. We describe the impalement of giant lipid vesicles by glass micropipet electrodes with a tight seal. To avoid displacement or burst during impalement, the vesicles are immobilized in relaxed conditions by microscopic picket fences of polyimide. The outer surface of the pipets is selectively coated with silanes or polylysine. Structurally, the impalement is verified by ejecting a fluorescent solution out of the pipet. For electrical characterization, current pulses are applied to the pipet and voltage transients are recorded. The data are evaluated in terms of the capacitance and effective resistance of the membrane. Directly after impalement, we observe a seal resistance up to 1.2 GOmega that continuously decays within a period of up to 20 min until it suddenly disappears without burst of the vesicle. During impalement, a spreading of the vesicle membrane along the outer surface of the pipets is observed using a fluorescent membrane-bound dye. We assign the tight pipet-vesicle contact to spreading of the lipid bilayer by a rolling mechanism and the loss of resistance to micro- and macropores that are induced by the resulting membrane tension. Limitation of spreading is attempted with barriers on the pipet.

Electric Impedance↗

Evaluation of method of preparation of passive diffusion tubes for measurement of ambient nitrogen dioxide.

This study was carried out in response to suggestions that the measurement of NO(2) by Palmes-type passive diffusion tubes (PDT) is affected by the method of preparation of the triethanolamine (TEA) absorbent coating on the grids. The following combinations of factors were investigated: TEA solvent (acetone or water), volume composition of TEA in solvent (50% or 20%), and grid coating method (dipping in solution prior to assembly or pipetting solution on after assembly). Duplicate PDTs prepared by each of the 8 methods were exposed in parallel, in urban air, for a total of 80 separate 1 week exposures. NO(2) concentrations derived from PDTs prepared by pipetting methods were significantly less precise than concentrations from dipping methods, with mean RSDs for duplicate measurements of 13.8% and 8.5%, respectively (n= 316 each category). Pipetting methods using solutions of 50% TEA composition were particularly imprecise (mean RSD 17.2%). Data from PDTs prepared by pipetting methods were systematically more poorly correlated with each other and with data from co-located chemiluminescence analysers, than corresponding data from PDTs prepared by dipping methods, indicating that more consistent accuracy was also obtained by the latter PDTs. The statistical evidence suggested that PDTs prepared by pipetting 50% TEA in water generally gave lower NO(2) concentrations. Although this is in agreement with a previous study, it is also possible that such an observation here may be a statistical artefact given the demonstrably poorer precision of this method. The general tendency of PDTs to show positive bias in NO(2) measurement in urban air in 1 week exposures was again evident in this study (mean biases at roadside and urban centre locations of +35% (n= 475) and +18% (n= 112), respectively) consistent with augmentation of within-tube NO(2) flux by chemical reaction between co-diffusing NO and O(3). Overall, it is recommended that the pipetting method of PDT grid preparation is avoided, or at least investigated further, because of the apparent degradation in precision and accuracy of NO(2) measurement. Potential reasons for the effect are discussed.

Adsorption↗

Application of the dual-micropipet technique to the measurement of tumor cell locomotion.

The objective of this work was to characterize tumor cell locomotion in response to chemotactic stimulation using a dual-micropipet assay. The assay involves two micropipets. An individual A2058 human melanoma cell was retained, without pressure gradient, in a pipet of approximately 14 micrometers i.d. A solution of type IV collagen, chosen as the chemotactic source, was placed in another pipet (approximately 10 micrometers o.d.) with zero pressure at the pipet tip. The smaller pipet was then inserted into the larger one containing the melanoma cell. The initial chemoattractant concentration (C0) and the distance between the tip of the small pipet and the cell surface (delta) provided a gradient (C0/delta) for tumor cell locomotion toward stimulation. This novel assay provides a direct measure of cell movement: cyclic pseudopod protrusion (Lp) and subsequent cell locomotion (Lc). The influences of different adhesion substrates on cell locomotion were also studied. The peak length in Lp precedes the highest locomotion velocity (dLc/dt) by an apparent lag time. C0/delta influences pseudopod protrusion frequency (fp) and dLc/dt, but not significantly on Lp. Substrate adhesions affect dLc/dt, but apparently not Lp or fp. In conclusion, pseudopod protrusion and substrate adhesion are two necessary but mutually independent factors in tumor cell locomotion. dLc/dt correlates with changes in C0/delta, which is in significant correlation with fp but not Lp.

Chemotaxis↗

Cortical shell-liquid core model for passive flow of liquid-like spherical cells into micropipets.

Many nonadherent cells exist as spheres in suspension and when sucked into pipets, deform continuously like liquids within the fixed surface area limitation of a plasma membrane envelope. After release, these cells eventually recover their spherical form. Consequently, pipet aspiration test provides a useful method to assay the apparent viscosity of such cells. For this purpose, we have analyzed the inertialess flow of a liquid-like model cell into a tube at constant suction pressure. The cell is modeled as a uniform liquid core encapsulated by a distinct cortical shell. The method of analysis employs a variational approach that minimizes errors in boundary conditions defined by the equations of motion for the cortical shell where the trial functions are exact solutions for the flow field inside the liquid core. For the particular case of an anisotropic liquid cortex with persistent tension, we have determined universal predictions for flow rate scaled by the ratio of excess pressure (above the threshold established by the cortical tension) and core viscosity which is the reciprocal of the dynamic resistance to entry. The results depend on pipet to cell size ratio and a parameter that characterizes the ratio of viscous flow resistance in the cortex to that inside the cytoplasmic core. The rate of entry increases markedly as the pipet size approaches the outer segment diameter of the cell. Viscous dissipation in the cortex strongly influences the entry flow resistance for small tube sizes but has little effect for large tubes. This indicates that with sufficient experimental resolution, measurement of cell entry flow with different-size pipets could establish both the cortex to cell dissipation ratio as well as the apparent viscosity of the cytoplasmic core.

Cell Adhesion↗

A novel micropipet method for measuring the bending modulus of vesicle membranes.

A theoretical model and an experiment are presented for determining the bending modulus of a bilayer vesicle membrane. The vesicle is held with a pipet having a radius between 1 and 2 microns, and the tension in the membrane is changed by changing the suction pressure. Then the vesicle membrane is deformed by aspirating it into a smaller pipet having a radius on the order of 0.5 microns. The relationship between the suction pressures in the two pipets is found to be linear, as predicted by the theoretical model. The curvature of the vesicle membrane at the pipet orifice and the bending modulus are found with the help of the model from the slope and the intercept of the linear experimental relationship between the suction pressures in the two pipets. The bending modulus for the two SOPC membranes studied in these experiments was found to be either 0.6 or 1.15 x 10(-19) J, which is similar to the values measured previously.

Elasticity↗

Robotic automation performs a nested RT-PCR analysis for HCV without introducing sample contamination.

The Polymerase Chain Reaction (PCR) is a popular method to amplify and detect specific RNA and DNA sequences. To obtain maximum performance of PCR, it is best performed by highly skilled technologists because of the complexity of the assay and the potential for laboratory contamination from the amplification products produced. We chose to automate this nested RT-PCR for hepatitis C assay to significantly reduce the need for manual pipetting while preserving the excellent non-contamination performance of the corresponding manual test. A three axis cartesian robotic pipetting station was equipped to perform RT-PCR using an on-board automated thermal cycling device. 104 sera were analyzed using this modified pipetting station and we found a very close agreement (100% sensitivity and 98% specificity) with results previously obtained by corresponding manual RT-PCR analysis. This study demonstrated a user-programmed robotic pipetting system could successfully automate a complex PCR assay without contamination. Our results suggest that use of robotic pipetting station can provide cost efficient alternative to performance of molecular diagnostic assays while demonstrating minimal inter sample contamination.

Electrophoresis, Agar Gel↗