Frequency-doubling perimetry in patients following penetrating keratoplasty.

PURPOSE: Perimetry using a frequency-doubling technique (FDT perimetry) is becoming established as a new diagnostic tool to detect early visual field losses. The aim of this study was to evaluate the diagnostic usefulness of an FDT perimetry protocol (C-20-5) in patients after penetrating keratoplasty (PK) and to assess whether this method is influenced by postoperative corneal topographic changes. METHODS: Thirty-six patients (age 40 +/- 13, median 41 years) following PK and 68 age-matched controls were included in this study. The postoperative interval was 21 +/- 19, median 14 months. Patients with preexisting glaucoma or any postoperative intraocular pressure elevation were excluded. The indications for PK were keratoconus in 82%, Fuchs dystrophy in 15%, and secondary bullous keratopathy in 3%. In 19 patients keratoplasty was performed in 1 eye. FDT perimetry was evaluated in both eyes to judge intraindividual variability. FDT perimetry was done using the screening strategy, which begins testing at the normal 5% probability level. If a stimulus is not detected, further targets are presented. FDT viewfinder and statistics software were used for case-wise recalculation of all missed localized probability levels. RESULTS: Neither mean overall FDT score (0.8 +/- 1.9, median 0.0 versus 0.9 +/-1.0, median 0.0) nor total test time (44 +/- 4.7, median 44 versus 44 +/- 4.2, median 42 seconds) showed significant differences between patients after PK and controls (P = 0.5). There was also no significant difference of mean FDT score between eyes after keratoplasty (0.8 +/- 1.9, median 0.00) and nonoperated contralateral eyes (0.9 +/- 2.0, median 0.00, P = 0.8) in the same patient. No significant correlation between FDT score and visual acuity as well as corneal keratometric astigmatism could be found in patients after PK and in normals (r < 0.2, P = 0.3). In patients after PK, FDT score and examination time were statistically independent of keratometric astigmatism (P = 0.7), topographic astigmatism (P = 0.4), spherical equivalent (P = 0.5), central corneal thickness (P = 0.7), and interval of postoperative follow-up (P = 0.6). CONCLUSIONS: Perimetry using the FDT protocol (C-20-5) seems to be feasible in patients after PK and does not depend on postoperative topographic changes of the cornea. This method allows valid information on visual field abnormality in patients after PK The results indicate that this method may be helpful as a supplement to detect early glaucomatous damage in patients after PK.

Adult↗

Use of a portable head mounted perimetry system to assess bedside visual fields.

AIM: This study was designed to test the ability of a portable computer driven, head mounted visual field testing system to perform automated perimetry on patients at their bedside and to compare these results with the "gold standard" for bedside examinations, confrontation visual fields. METHODS: The Kasha visual field system is a portable automated perimeter which utilises a virtual reality headset. 37 neurosurgery patients were examined at their bedside with a central 24 degree suprathreshold testing strategy after confrontation visual field testing. The patterns of visual field defects were categorised and compared with the results of confrontation testing. RESULTS: A total of 42 field examinations were completed on 37 patients, and the average testing time for both eyes was 4.8 minutes with the perimetry system. Each of the 11 fields (100%) classified with defects on confrontation testing was similarly categorised on head mounted perimetry. 26 out of 31 (84%) visual fields were normal on both confrontation and perimetry testing, while five out of the 31 fields (16%) which were full on confrontation had visual field defects identified by head mounted perimetry. CONCLUSION: The head mounted, automated perimetry system proved easily portable and convenient for examining neurosurgical patients at their bedside in the perioperative period. The device demonstrated equal sensitivity to confrontation visual field testing methods in detecting field defects and offers the advantage of standardised, quantifiable testing with graphic results for follow up examinations.

Adult↗

Blue-on-yellow and achromatic perimetry in diabetic children without retinopathy.

OBJECTIVE: We compared blue-on-yellow perimetry with achromatic perimetry to determine whether the first was more sensitive in detecting visual field defects. RESEARCH DESIGN AND METHODS: We studied 50 children and adolescents (22 male, 28 female) with IDDM, ranging in age from 10.1 to 16.3 years (mean 13.3+/-2.1 years), with a disease duration of 5.2-10.0 years (mean 7.1+/-1.9 years). Patients were divided into subgroups according to the presence of persistent microalbuminuria. No one had signs of diabetic retinopathy when studied with fluorescein angiography. RESULTS: By achromatic perimetry, the analysis of subareas of the central 30 degrees of the visual field (0-9 degrees; 10-18 degrees; out of 18 degrees) showed no differences between diabetic subgroups in the central 18 degrees of the visual field, while a significant difference between the same subgroups was found outside the 18 degrees of the 24-2 program of the Humphrey perimeter (P = 0.027). By blue-on-yellow perimetry, in all three of the perimetric subareas evaluated, the sensitivity was lower in microalbuminuric patients than in normoalbuminuric ones. The differential sensitivity between the perimetric tests performed with blue-on-yellow and with achromatic stimuli showed statistically significant data, with a higher level of significance in the central 18 degrees (P < 0.0001) than outside the 18 degrees (P = 0.033). CONCLUSIONS: Our study suggests that blue-on-yellow perimetry is more useful and more sensitive than achromatic perimetry in the detection of preclinical visual field defects in diabetic children with microalbuminuria but without clinically detectable retinopathy.

Adolescent↗

Frequency doubling perimetry and the detection of eye disease in the community.

PURPOSE: Frequency Doubling Technology (FDT) perimetry is a novel perimetric test that provides rapid screening (45 to 60 seconds) and full-threshold (4 to 5 minutes) testing for detection of vision loss. The purpose of this study was to determine the specificity and sensitivity of FDT perimetry for the detection of ocular disease. METHODS: A total of 130 participants (257 eyes of 42 men and 88 women) recruited from the community completed FDT perimetry, standard achromatic automated perimetry (SAP), anterior segment biomicroscopy, tonometry, and dilated ophthalmoscopy. FDT results were considered abnormal if 1 point was abnormal (depressed below the 5% level on the screening protocol C-20-5). SAP was considered abnormal if the glaucoma hemifield test or pattern standard deviation was outside normal limits (P < .05) or a hemifield cluster of 3 depressed points on the pattern deviation probability plot (P < .05) was present. An abnormal eye examination was defined as the presence of an abnormality in the anterior segment, lens, or posterior segment that was likely to cause a visual field defect or the presence of glaucomatous or other optic neuropathy. RESULTS: The mean age (+/- SD) of participants was 55.5 years (+/- 10.3). Ethnic groups, as reported by participants, included 77 (59%) African Americans, 40 (31%) Caucasians, and 13 (10%) in other groups. On clinical examination, 116 eyes (45%) were normal, 9 eyes (3.5%) had a cataract with best corrected visual acuity worse than 20/30, 16 eyes (6%) had open-angle glaucoma, and 17 eyes (7%) had retinal findings or lesions that were likely to cause a visual field defect. For FDT perimetry, 22 (8.6%) of 257 tests were unreliable, and for SAP, 65 (25.3%) of 257 tests were unreliable. The sensitivity and specificity of FDT perimetry for detecting an abnormal clinical examination were 55% and 90% and for detecting an abnormal examination that included an abnormal SAP, 64% and 86%. CONCLUSIONS: FDP demonstrated reasonable discriminatory power for detecting eye disease.

Adult↗

Long-term fluctuation in short-wavelength automated perimetry in glaucoma suspects and glaucoma patients.

PURPOSE: To determine the magnitude of the homogeneous, LF(Ho), and the heterogeneous, LF(He), components of the long-term fluctuation (LF) in glaucoma suspects and in stable primary open angle glaucoma (POAG) patients undergoing short-wavelength automated perimetry (SWAP) and to compare the magnitude of the SWAP LF components with those elicited by standard white-on-white (W-W) perimetry. METHODS: The sample comprised 33 glaucoma suspects and 17 patients with early-to-moderate stable POAG who underwent W-W perimetry and SWAP at each of six visits over a mean period of 12.75 months (SD, 2.29). The LF(Ho), LF(He), and error components of the long-term fluctuation were determined between the third and seventh visual field examinations. The intervening visual field examinations and the optic nerve head parameters, derived both by stereo observation and by the Heidelberg Retinal Tomograph, were used to confirm stability over the follow-up period. RESULTS: The LF(Ho) and LF(He) components were larger in the POAG patients than in the glaucoma suspects for both W-W perimetry and SWAP; the magnitude was independent of the depth of defect and of the short-term fluctuation. All three components of long-term fluctuation were greater for SWAP than for W-W perimetry, both in the glaucoma suspects and in the POAG patients. CONCLUSIONS: SWAP exhibits greater long-term fluctuation than white-on-white perimetry. The usefulness of SWAP will be limited if the extent of this variability is not overcome in future statistical procedures developed to detect progressive visual field loss.

Adult↗

[Initial findings with pulsar perimetry in patients with ocular hypertension].

PURPOSE: To evaluate our first results with Pulsar perimetry in patients with ocular hypertension and compare them with normal individuals. METHODS: We studied 34 eyes of patients with ocular hypertension and normal G1 Octopus perimetry (mean age: 57.29 S.D. 10.55) and 41 eyes of normal individuals (mean age: 48.34 S.D. 13.71). A complete ophthalmologic examination, including Dr. González de la Rosa's Pulsar perimetry with TOP strategy, was performed for all patients. EXCLUSION CRITERIA: visual acuity <0.8, refractive defect 3 spheric dp or 1.5 astigmatic dp, pupil size <3 mm, ocular surgery or pathologies, non-controlled diabetes or neurological diseases. They all had previous perimetric experience. Results were analyzed with student t - test. RESULTS: For normal individuals, mean sensitivity (MS) for Pulsar perimetry was 21,25 src (spatial resolution and contrast units) with an S.D. of 2,70. Mean defect (MD) was 0,93 src S.D. 1,80 and loss variance (LV) was 6,11 src S.D. 4,30. For patients with ocular hypertension: MS was 18,65 src S.D. 2,79; MD was 2,73 src S.D. 2,30 and LV was 8,46 src S.D. 5,01. LV differences between the two groups were statistically significant (p<0.05) with 95% confidence limits of (-4.49; -0.20), and MS and MD differences, highly significant (p<0.01), with 99% confidence limits of (+0.92; +4.28;) and (-3.05; -0.54) respectively. CONCLUSIONS: Pulsar perimetry may have greater sensibility for the detection of early defects in patients with ocular hypertension than conventional perimetry.

Adolescent↗

[Flicker perimetry (CFF) in glaucoma diagnosis].

PURPOSE: Evaluation of CFF perimetry results in patients with suspected glaucoma. MATERIAL AND METHODS: Visual field was measured on Octopus 301 perimeter with option "flicker perimetry". 49 patients (98 eyes) with suspected glaucoma were tested. Standard W/W perimetry revealed glaucomatous visual field defect in one eye, but not in the second eye. Patients with cataract and diabetes were not taken into consideration. RESULTS: Defects in CFF perimetry tests were found in 71.4% of cases, but in W/W perimetry test in 50.0% of cases. CONCLUSIONS: Perimetry CFF is useful for early detection and follow up of glaucoma. Indices MD and LV may be used for those purposes.

Adult↗

[Flicker perimetry (CFF) in patients with lens opacities--first report].

PURPOSE: Comparison of standard W/W and CFF perimetry in patients with cataract and lens opacities. MATERIAL AND METHODS: Visual field was measured on Octopus 301 perimeter with option flicker perimetry. W/W and CFF perimetry (Program G1 in TOP strategy) was performed in 44 eyes with cataract and lens opacities. RESULTS: Defects in visual field with CFF perimetry were found in 24% of cases but with W/W perimetry in 100% of cases. CONCLUSIONS: Perimetry CFF is a new tool for early detection and follow up of visual field defects in patients with cataract and lens opacities.

Adult↗

[Modern perimetry: automatic or manual?].

The possible applications of computer assisted static perimetry are examined after one and a half year of personal experience. The general advantage of a computer-assisted perimeter may be the elimination of the influence of the perimetrist on the results. We have employed the PERITEST perimeter because this system allows either full automatic perimetry or two types of manual perimetry with presentation of single or multiple stimuli. All perimetric examination is done after the determination of the individual visual retinal threshold. The examination is always performed at a supraliminal level relative to the individual threshold. The following conclusions can be drawn: 1 - Even after complete elimination of the perimetrist's influence fluctuations in results may be observed. Furthermore, the longer examination the more important patient cooperation becomes in automated perimetry as compared to the manual procedure. So we concluded that the best strategy should be related to the studies of the visual field defects. 2 - For perimetry of presupposed normal visual fields, the multiple stimulus procedure is quite adequate. If some problem appears, the flexibility of the PERITEST enables the use of the single manual stimulus mode. The full automatic examination is done only when there are mild field defects and in intelligent patients. 3 - These techniques enable the description of a new presentation of the classical perimetry's signs of early glaucoma: a loss of 0,5 Log. U.L. (which has the same significance as an isolated relative scotoma.

Computers↗

Correlation between the optic disc and results obtained with conventional, high-pass resolution and pattern discrimination perimetry in glaucoma.

The purpose of this study was to determine whether results obtained with two new techniques, high-pass resolution perimetry and pattern discrimination perimetry, correlated better to the appearance of the optic disc than results obtained with conventional automated perimetry in patients with open-angle glaucoma. Our sample consisted of 28 eyes of 28 patients with early glaucomatous field damage who are part of a prospective follow-up study. We used the second of two sets of baseline perimetric examinations separated by 1 week in the analysis. Neuroretinal rim area was calculated by planimetry of stereophotographs of the disc and was correlated to the visual field sensitivity measured with each of the techniques. We found a poor correlation between the disc and field measurements (correlation coefficients; -0.048 for conventional perimetry, 0.111 for high-pass resolution perimetry and -0.315 for pattern discrimination perimetry). Although the correlation appeared to be higher with the newer techniques, the differences were not statistically significant.

Adolescent↗

Mechanisms mediating visual detection in static perimetry.

PURPOSE: The usual stimuli in static perimetry are white-light luminance increments. However, the specific visual detection mechanisms involved in perimetry are unknown because all classes of neural mechanisms are sensitive to spectrally broadband stimuli. The objective of this study was to determine the relative sensitivities of nonopponent and opponent detecting mechanisms under standard perimetry test conditions. METHODS: Using trained rhesus monkey subjects, the relative sensitivities of the vision mechanisms for the detection of perimetry test stimuli were determined through psychophysical measurements of spectral sensitivity at each of the test field locations of the C24-2 threshold program on the Humphrey Field Analyzer (Allergan Humphrey, San Leandro, CA). The spectral sensitivity functions were analyzed by a three-channel model that incorporated independent short-wavelength-sensitive, nonopponent (luminance), and opponent (chromatic) spectral sensitivity mechanisms. RESULTS: The visual detection mechanisms for perimetry thresholds varied as a function of the size and wavelength of the test field. With the perimeter's standard stimulus (Goldmann Size III) and bowl illumination (31.5 asb), the presence of a short-wavelength-sensitive mechanism was clearly evident at all field locations, but its relative sensitivity systematically declined with eccentricity. Under these conditions, the sensitivities of the opponent and nonopponent mechanisms were approximately equal at most field locations. With a larger stimulus (Goldmann Size V), however, the contribution of the opponent spectral sensitivity mechanism was more apparent over most of the central field and the alterations of sensitivity with eccentricity were less pronounced. In contrast, a small test field (Goldmann Size II) appeared to bias detection toward nonopponent mechanisms. CONCLUSION: The results of these investigations indicate that detection thresholds during perimetry can be effectively biased toward different photopic, visual processing channels through the appropriate selection of size and wavelength of the test stimulus.

Animals↗

Statistical aspects of the normal visual field in short-wavelength automated perimetry.

PURPOSE: To determine the intraindividual and interindividual characteristics of normal sensitivity derived by short-wavelength automated perimetry (SWAP) as a function of threshold algorithm. To determine also the influence of ocular media absorption on the magnitude of the interindividual variation in normal sensitivity, and hence the confidence limits, derived by SWAP. METHODS: The sample comprised 51 normal subjects, stratified for age by decade (mean age, 55.5 years; range, 24-83 years) and experienced in white-on-white (W-W) perimetry and SWAP. One randomly assigned eye of each subject was examined on three occasions with Program 30-2 of the 640 Humphrey Field Analyzer using the Full Threshold and FASTPAC strategies for SWAP and W-W perimetries. Ocular media absorption (OMA) was assessed by the difference in scotopic sensitivity to stimuli of 410 and 560 nm. RESULTS: The group mean examination time (P < 0.001) was greater for SWAP than for W-W perimetry for both the Full Threshold (15.0% longer) and FASTPAC strategies (16.8% longer). The gradient of the age-decline in Mean Sensitivity for SWAP was approximately 25% less steep when corrected for OMA than when uncorrected. The interindividual normal variability, expressed as the coefficient of variation, for SWAP without correction for OMA was 2.7 times greater (range 2.0-3.9), and with correction 1.9 times greater (range 1.4-2.9), than that for W-W perimetry. CONCLUSIONS: The increased interindividual normal variability of SWAP, exacerbated by the lack of correction for OMA, currently limits the utility of SWAP in that the reduction in sensitivity required to indicate abnormality was proportionately greater than for W-W perimetry.

Absorption↗

Motion automated perimetry identifies early glaucomatous field defects.

OBJECTIVE: To determine if motion automated perimetry can identify early glaucomatous visual field defects in patients with suspected glaucoma (by disc), those with ocular hypertension, and those with primary open-angle glaucoma. METHODS: Motion automated perimetry, a foveally centered motion test, and standard visual field tests were conducted on one randomly selected eye of normal patients (n = 38), patients with suspected glaucoma (by disc) (n = 28), patients with ocular hypertension (n = 18), and patients with primary open-angle glaucoma (n = 21). Subjects' performance on both motion tests were compared with their performance on standard perimetry. RESULTS: Perimetric motion thresholds significantly distinguished the groups (P< or =.001), while the foveally centered motion test was unable to separate them (P< or =.32). Of the total patients, 90.5% of those with glaucoma, 39.3% of those with suspected glaucoma, 27.8% of those with ocular hypertension, and 5.3% of the normal subjects had abnormal results on motion automated perimetry testing. Perimetric motion thresholds were significantly correlated with standard visual field thresholds (P< or =.001). CONCLUSION: Motion automated perimetry identifies visual field defects in patients who already show standard visual field loss as well as in a moderate percentage of those with suspected glaucoma and ocular hypertension, indicating that the testing of discrete locations might be necessary for increased diagnostic utility.

Aged↗

The utility of entoptic perimetry as a screening test for cytomegalovirus retinitis.

OBJECTIVE: To determine the sensitivity and specificity of entoptic perimetry as a noninvasive test for detecting retinal damage due to peripheral cytomegalovirus (CMV) retinitis. DESIGN: A masked study comparing entoptic perimetry with fundus photography under 4 experimental conditions (determined by increasing pixel sizes) on 2 separate testing sessions. SETTING: Acquired immunodeficiency syndrome Ocular Research Unit at the University of California, San Diego. PATIENTS: Twenty-four human immunodeficiency virus-positive and 8 human immunodeficiency virus-negative subjects; 21 eyes with documented CMV retinitis, and 26 eyes that were retinitis free. MEASUREMENTS: For each testing session, screening method, and condition, the presence of CMV retinitis was determined for each meridian (i.e., clock hour), each quadrant (consisting of 3 meridians), and each eye (consisting of all meridians); the amount of retinitis was defined as the percentage of meridians or quadrants with CMV retinitis. RESULTS: Entoptic perimetry was as sensitive and specific as fundus photography in determining the presence of CMV retinitis. Determination of the amount of CMV retinitis tended to be underestimated by perimetry for larger pixel sizes. CONCLUSION: Entoptic perimetry may be an effective and inexpensive alternative to fundus photography for CMV retinitis in hospitals and community clinics.

AIDS-Related Opportunistic Infections↗

A comparison of manual kinetic and automated static perimetry in obtaining ptosis fields.

OBJECTIVE: To compare examination time and visual field loss for ptosis fields obtained with manual kinetic (Goldmann) perimetry and automated static (Humphrey) perimetry. METHODS: Both eyes of 12 patients with bilateral aponeurogenic ptosis were prospectively examined using Goldmann and Humphrey (ptosis protocol) perimetry with the eyelids ptotic and taped into a normal position. RESULTS: Bilateral examination time for Goldmann fields was 10 +/- 2 minutes and for Humphrey fields was 50 +/- 10 minutes (P<.001, n = 12). Superior fields at the 12:00 meridian were 46 degrees +/- 6 degrees taped, and 28 degrees +/- 12 degrees untaped for Goldmann perimetry (P<.001), and 38 degrees +/- 8 degrees taped, and 24 degrees +/- 12 degrees untaped for Humphrey perimetry P<.001). Goldmann field loss was 18 degrees +/- 9 degrees (taped minus untaped). Humphrey field loss was 14 degrees +/- 13 degrees (P<.04, n = 24). Mean Goldmann radial fields were 56 degrees +/- 6 degrees taped and 39 degrees +/- 13 degrees untaped (P<.001). Goldmann superior hemifield areas were 5,167 +/- 964 degrees2 taped and 2,830 +/- 1,466 degrees2 untaped (P<.001). Humphrey mean vertical superior hemifield was 37 degrees +/- 9 degrees taped and 21 degrees +/- 11 degrees untaped (P<.001). Mean sensitivity of Humphrey fields was 15 +/- 3 dB taped and 9 +/- 5 dB untaped (P<.001). Mean vertical center of gravity was 23 degrees +/- 3 degrees taped and 16 degrees +/- 5 degrees untaped (P <.001). CONCLUSION: Goldmann manual kinetic and Humphrey automated static visual field testing are both effective in documenting ptosis associated visual field loss. Humphrey automated ptosis fields, as performed in this study, require longer examination times than Goldmann manual fields and may be a less sensitive indicator of field loss.

Adult↗

Optic disc and visual field changes in a prospective longitudinal study of patients with glaucoma: comparison of scanning laser tomography with conventional perimetry and optic disc photography.

OBJECTIVE: To investigate the relationship between optic disc changes measured with scanning laser tomography and those measured with conventional perimetry and optic disc photography. METHODS: In a prospective longitudinal study, we followed up 77 patients with early glaucomatous visual field damage. Scanning laser tomography (using the Heidelberg Retina Tomograph) and conventional perimetry (using the Humphrey Field Analyzer) were carried out every 6 months. Disc progression was determined by a procedure recently described by us for scanning laser tomography, with confirmed progression requiring repeatable changes based on probability limits for both the depth (using individual test-retest variability values) and size of change (determined in a group of 37 healthy individuals also followed up prospectively). Field progression was determined with the Statpac Glaucoma Change Probability Analysis. The agreement between scanning laser tomography and conventional disc photography was determined in a subgroup of patients. RESULTS: Patients were followed up for a median of 5.5 years, with a median of 12 sets of examinations with scanning laser tomography and conventional perimetry. Twenty-one patients (27%) showed no progression with either technique. Thirty-one patients (40%) progressed with scanning laser tomography only, while 3 (4%) progressed with conventional perimetry only. Of the 22 patients (29%) who progressed with both techniques, 10 (45%) progressed with scanning laser tomography first (median, 18 month earlier) and 9 (41%) with conventional perimetry first (median, 12 months earlier), while 3 (14%) progressed at the same time. Of the 16 patients with disc photographs that closely overlapped the follow-up, there was concordance between scanning laser tomography and disc photography in 13 patients (81%). CONCLUSIONS: Glaucomatous disc changes determined with scanning laser tomography occur more frequently than field changes. Most patients with field changes also had disc changes; however, less than half of those with disc changes had field changes.

Adult↗

Scanning laser entoptic perimetry for the detection of age-related macular degeneration.

OBJECTIVE: To determine the sensitivity and specificity of scanning laser entoptic perimetry for detecting visual function damage due to age-related macular degeneration (ARMD). METHODS: We measured the presence or absence of visual field disturbances by entoptic perimetry and determined the severity of ARMD based on masked readings of fundus photographs. A prospective masked study comparing the findings of entoptic perimetry with fundus photographs was performed. We recruited 91 patients with ARMD and 24 patients without ARMD during ophthalmologic visits. An appropriate institutional review board approval was obtained for the project. The main outcome measure was the detection of visual scotomata. RESULTS: Scanning laser entoptic perimetry had an overall sensitivity of 82% and a specificity of 100% for the detection of ARMD. The sensitivity for early stages of the disease is greater than 70%, and increases to above 90% for moderate to late stages. CONCLUSION: Scanning laser entoptic perimetry is a specific and sensitive test for detecting ARMD, even at the earliest stages when patients are typically asymptomatic.

Aged↗

Computerized profile perimetry in glaucoma.

The new profile testing mode of the COMPETER automatic perimeter was clinically tested and compared with careful manual profile perimetry on the Tübinger perimeter. Each of 110 patients with glaucomatous field defects, patients with suspected glaucoma, and normal subjects had one meridian tested. All of the 55 patients who showed an abnormal result on the manual profile also had abnormal findings on the automatic test. Two (4%) of the profiles labeled as normal on initial manual perimetry were identified by the automatic perimeter to be abnormal, and these defects were confirmed on repeated manual profile perimetry. The automatic perimetry gave five (9%) false-positive results in the 53 normal manual profiles, thus giving a specificity of 91%. In two of these cases, the automatic profile indicated defects in areas where the manual profile appeared normal, but there was abnormality in the manual kinetic perimetry in the affected area. The automatic profiles of the COMPETER automatic perimeter are accurate, sensitive, time-saving, and clinically useful.

Adolescent↗