Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical imaging”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Optical imaging systems--the future of medical record storage.

This paper explains the processes which were undertaken to solve the problem of lack of storage for medical records at Logan Hospital. The paper contains analysis of why optical disk proved to be the most appropriate storage medium, and the system components of an Optical Disk System. A detailed description of how the Optical Imaging System has been structured and the processes which make the Optical Disk System a major part of the hospital's Health Information System is provided. The paper also discusses the much talked about legal side of optical imaging. Lastly the paper explains the future plans of Logan Hospital's Medical Record Storage System.

Hospital Bed Capacity, under 100↗

Optical imaging fiber-based live bacterial cell array biosensor.

A live cell array biosensor was fabricated by immobilizing bacterial cells on the face of an optical imaging fiber containing a high-density array of microwells. Each microwell accommodates a single bacterium that was genetically engineered to respond to a specific analyte. A genetically modified Escherichia coli strain, containing the lacZ reporter gene fused to the heavy metal-responsive gene promoter zntA, was used to fabricate a mercury biosensor. A plasmid carrying the gene coding for the enhanced cyan fluorescent protein (ECFP) was also introduced into this sensing strain to identify the cell locations in the array. Single cell lacZ expression was measured when the array was exposed to mercury and a response to 100nM Hg(2+) could be detected after a 1-h incubation time. The optical imaging fiber-based single bacterial cell array is a flexible and sensitive biosensor platform that can be used to monitor the expression of different reporter genes and accommodate a variety of sensing strains.

Adenosine Triphosphatases↗

High-resolution functional optical imaging: from the neocortex to the eye.

Much work remains to be done to establish the clinical usefulness of the RFI for early diagnosis and treatment guidance. The discoveries obtained by functional optical imaging of the neocortex in the last 15 years and the recent RFI studies of the eyes of normal subjects and patients with diabetic retinopathy, glaucoma, and age-related macular degeneration suggest that functional optical imaging of the retina is likely to become a multi-modality powerful clinical tool.

Animals↗

Optical imaging of human breast cancer.

Since an increasing number of breast cancers have been reported in recent years, there is a need for improving techniques for early detection of the breast cancer. Here we tested a time gated optical imaging technique as a tool for imaging human breast. Pulsed laser light at wavelengths of 780 and 830 nm are transmitted through human breast tissues and time spectra of the diffused light through the tissue are recorded over nanoseconds. Data from different locations are acquired and used to reconstruct a two dimensional image as a set of spectra in pixel form. The imaging consists of absorption and scattering coefficients, and the absorption coefficients at the two wavelengths are related to oxygen concentration and blood volume. The analysis of these coefficients is based upon the early arrival photons, therefore allowing construction of a better image than those from the current diaphanography. We demonstrate images of breast cancer, cysts created after lumpectomy, and consequences of radiation therapy. Results show that time gated optical imaging can image oxygen concentration in the cancerous and fibrotic breasts. Resolution of the imaging for smaller tumor size needs to be improved.

Adult↗

Wavelet-based multi-resolution statistics for optical imaging signals: Application to automated detection of odour activated glomeruli in the mouse olfactory bulb.

Optical imaging techniques offer powerful solutions to capture brain networks processing in animals, especially when activity is distributed in functionally distinct spatial domains. Despite the progress in imaging techniques, the standard analysis procedures and statistical assessments for this type of data are still limited. In this paper, we perform two in vivo non-invasive optical recording techniques in the mouse olfactory bulb, using a genetically expressed activity reporter fluorescent protein (synaptopHfluorin) and intrinsic signals of the brain. For both imaging techniques, we show that the odour-triggered signals can be accurately parameterized using linear models. Fitting the models allows us to extract odour specific signals with a reduced level of noise compared to standard methods. In addition, the models serve to evaluate statistical significance, using a wavelet-based framework that exploits spatial correlation at different scales. We propose an extension of this framework to extract activation patterns at specific wavelet scales. This method is especially interesting to detect the odour inputs that segregate on the olfactory bulb in small spherical structures called glomeruli. Interestingly, with proper selection of wavelet scales, we can isolate significantly activated glomeruli and thus determine the odour map in an automated manner. Comparison against manual detection of glomeruli shows the high accuracy of the proposed method. Therefore, beyond the advantageous alternative to the existing treatments of optical imaging signals in general, our framework propose an interesting procedure to dissect brain activation patterns on multiple scales with statistical control.

Algorithms↗

Fluorescence and absorption contrast mechanisms for biomedical optical imaging using frequency-domain techniques.

The ability to optically image or detect diseased tissue volumes located deep within tissues depends upon the degree of contrast provided by differences in local optical properties. In this report, we show that the exogenous contrast offered by fluorescent compounds is superior to that provided by nonfluorescing, light-absorbing compounds when time-dependent measurements are employed. In addition, we show that the induced contrast is not only moderated by the preferential uptake of fluorescent agents into diseased tissue volumes of interest but also by the fluorescent optical properties and the fluorescence dynamics in the specific tissue volume. Using tissue phantom studies, we demonstrated experimentally that near-infrared-absorbing and fluorescent dyes such as indocyanine green can provide detection of diseased tissue volumes from fluorescence measurements made at the periphery of tissue when there is perfect, 100-fold and 10-fold partitioning in diseased tissues over that in surrounding normal tissues. Experimental results of common laser dyes show the contrast is also mediated by the quantum yield and lifetime parameters that may be dependent upon the local tissue environment.

Diagnosis↗

Optical imaging in vitro provides evidence for the minicolumnar nature of cortical response.

The response of rat neocortical slices to electrical stimulation at the layer VI/white matter border was recorded using intrinsic signal optical imaging. The optical response of the slice is column-shaped, extends from layer VI to the pial surface, and is strongly correlated with the amplitude of simultaneously recorded evoked potentials. Spectral analysis revealed radially oriented spatial variations in the intensity of the optical signal with a period of 30-60 microm/cycle. Nissl-stained sections of slices also exhibited a radially oriented periodicity in optical density with the same period. We conclude that the periodic variations in the intrinsic optical signal correspond to stimulus-activated minicolumns.

Animals↗

Optical imaging of cat auditory cortex cochleotopic selectivity evoked by acute electrical stimulation of a multi-channel cochlear implant.

We measured reflectance changes by means of optical imaging of intrinsic signals to study the effects of acute electrical cochlear stimulation on the topography of the cat auditory cortex. After single-pulse electrical stimulation at selected sites of a multichannel implant device, we found topographically restricted response areas representing mainly the high-frequency range in AI. Systematic variation of the stimulation pairs and thus of the cochlear frequency sites revealed a systematic and corresponding shift of the response areas that matched the underlying frequency organization. Intensity functions were usually very steep. Increasingly higher stimulation currents evoked increasingly larger response areas, resulting in decreasing spatial, i.e. cochleotopic, selectivity; however, we observed only slight positional shifts of the focal zones of activity. Electrophysiological recordings of local field potential maps in the same individual animals revealed close correspondence of the locations of the cortical response areas. The results suggest that the method of optical imaging can be used to map response areas evoked by electrical cochlear stimulation, thereby maintaining a profound cochleotopic selectivity. Further experiments in chronically stimulated animals will shed more light on the degree of functional and reorganizational capacities of the primary cortex and could be beneficial for our understanding of the treatment of profound deafness.

Animals↗

Optical imaging of odorant representations in the mammalian olfactory bulb.

We adapted the technique of intrinsic signal imaging to visualize how odorant concentration and structure are represented spatially in the rat olfactory bulb. Most odorants activated one or more glomeruli in the imaged region of the bulb; these optically imaged responses reflected the excitation of underlying neurons. Odorant-evoked patterns were similar across animals and symmetrical in the two bulbs of the same animal. The variable sensitivity of individual glomeruli produced distinct maps for different odorant concentrations. Using a series of homologous aldehydes, we found that glomeruli were tuned to detect particular molecular features and that maps of similar molecules were highly correlated. These characteristics suggest that odorants and their concentrations can be encoded by distinct spatial patterns of glomerular activation.

Animals↗

[NMR tomography of the cartilage structures of the knee joint with 3D-volume imaging combined with a rapid optical-imaging computer].

MRI is of increasing importance as a noninvasive method for the investigation of abnormalities in the knee. 2-D spin-echo sequences were compared with 3-D gradient-echo sequence using normal and cadaver knee joints. 3-D imaging using a fast computer was found to provide significantly improved diagnostic information concerning the cartilage when compared with a 2-D spin-echo techniques. The important advantages are: sections of less than 1 mm., reconstruction in any required plane, which can be related to the complex anatomy of the knee joint, and very good distinction between intra-articular fluid, fibrocartilage and hyaline cartilage.

Cadaver↗

Carbocyanine labeled LDL for optical imaging of tumors.

RATIONALE AND OBJECTIVES: The purpose of this study was to define and characterize carbocyanine labeled low-density lipoprotein (LDL) to be used in the optical imaging of LDL receptor (LDLr)-overexpressing tumor models. MATERIALS AND METHODS: 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (DiI) was used to label LDL (DiI-LDL). Scatchard plots were generated to determine the maximum binding capacity B(max) and dissociation constants K(D) of DiI-LDL in B16 melanoma (B16) and hepatoblastoma G(2) (HepG(2)) cell lines. Selective uptake of DiI-LDL into both tumor cells and corresponding subcutaneous tumors in mice were demonstrated by confocal microscopy and three-dimensional Cryo-imaging, respectively. RESULTS: The labeling efficiency of DiI-LDL was 61 ng DiI/microg LDL protein (34 mol DiI/mol LDL protein). B(max) and K(D) for B16 cells were 6.311 ng LDL/mg cell protein and 60.38 microg protein/mL (117 nM), respectively. B(max) and K(D) were 7.573 ng LDL/mg cell protein and 26.79 microg protein/mL (52 nM) for HepG(2) cells, respectively. Confocal microscopic images showed specific uptake of DiI-LDL throughout the cytoplasm in the B16/HepG(2) cells. Cryo-imaging demonstrated preferential accumulations of DiI-LDL in the viable tumor regions of both B16 and HepG(2) tumors compared with their adjacent normal tissues and corresponding necrotic tumor regions. In addition, uptake of DiI-LDL by the HepG(2) tumor was much higher than that of the B16 tumor, consistent with the fact that the probe binding affinity for LDLrs of HepG(2) cells is 2.3 times that of B16 cells. CONCLUSION: This study suggested that carbocyanine labeled LDL could be used for optical imaging of tumors overexpressing LDLr.

Animals↗

In vivo optical imaging using quantum dots for the management of brain tumors.

The surgical management of brain tumors requires the precise localization of tumor tissues within normal brain parenchyma in order to achieve accurate diagnostic biopsy and complete surgical resection. Quantum dots are optical semiconductor nanocrystals that exhibit stable, bright fluorescence. The intravenous injection of quantum dots is accompanied by reticuloendothelial system and macrophage sequestration. Macrophages infiltrate brain tumors and phagocytize intravenously injected quantum dots, optically labeling the tumors. Macrophage-mediated delivery of quantum dots to brain tumors may represent a novel technique to label tumors preoperatively. Quantum dots within tumors may be detected with optical imaging and optical spectroscopy tools, providing the surgeon with real-time optical feedback during the resection and biopsy of brain tumors.

Animals↗

Combined imaging and chemical sensing using a single optical imaging fiber.

Despite many innovations and developments in the field of fiber-optic chemical sensors, optical fibers have not been employed to both view a sample and concurrently detect an analyte of interest. While chemical sensors employing a single optical fiber or a noncoherent fiberoptic bundle have been applied to a wide variety of analytical determinations, they cannot be used for imaging. Similarly, coherent imaging fibers have been employed only for their originally intended purpose, image transmission. We herein report a new technique for viewing a sample and measuring surface chemical concentrations that employs a coherent imaging fiber. The method is based on the deposition of a thin, analyte-sensitive polymer layer on the distal surface of a 350-microns-diameter imaging fiber. We present results from a pH sensor array and an acetylcholine biosensor array, each of which contains approximately 6000 optical sensors. The acetylcholine biosensor has a detection limit of 35 microM and a fast (< 1 s) response time. In association with an epifluorescence microscope and a charge-coupled device, these modified imaging fibers can display visual information of a remote sample with 4-microns spatial resolution, allowing for alternating acquisition of both chemical analysis and visual histology.

Acetylcholinesterase↗

Optical imaging with a directional detector.

We demonstrate a new optical imaging technique based on a directional detector that measures the intensity of light waves that propagate only in a narrow angular window around a specific direction. Light waves that propagate in other directions do not significantly affect the detector output. The directional detector is obtained by illuminating the interrogated object with a high-coherence light source and measuring the interference between the light wave reflected from the object and a reference wave. By measuring the intensity of the interference pattern with an optical detector that has a finite width and moving the object by use of a rotation stage, one can obtain the angular directionality of the filter. The use of coherent detection in the directional detector makes it possible to increase the sensitivity of the system. The directional detector was analyzed theoretically and demonstrated experimentally for a Gaussian beam scattered from a conducting cylinder. The interference enabled us to theoretically increase the angular resolution by a factor of approximately 10 and experimentally by a factor of 8.5. A configuration for using a directional detector array to reconstruct a two-dimensional object is suggested. Since the directional detector makes it possible to reduce the effect of diffraction and scattering, reconstruction techniques based on nondiffracting sources, as implemented in x-ray tomography, may be used.

Journal Article↗

Hindered diffusion of high molecular weight compounds in brain extracellular microenvironment measured with integrative optical imaging.

This paper describes the theory of an integrative optical imaging system and its application to the analysis of the diffusion of 3-, 10-, 40-, and 70-kDa fluorescent dextran molecules in agarose gel and brain extracellular microenvironment. The method uses a precisely defined source of fluorescent molecules pressure ejected from a micropipette, and a detailed theory of the intensity contributions from out-of-focus molecules in a three-dimensional medium to a two-dimensional image. Dextrans tagged with either tetramethylrhodamine or Texas Red were ejected into 0.3% agarose gel or rat cortical slices maintained in a perfused chamber at 34 degrees C and imaged using a compound epifluorescent microscope with a 10 x water-immersion objective. About 20 images were taken at 2-10-s intervals, recorded with a cooled CCD camera, then transferred to a 486 PC for quantitative analysis. The diffusion coefficient in agarose gel, D, and the apparent diffusion coefficient, D*, in brain tissue were determined by fitting an integral expression relating the measured two-dimensional image intensity to the theoretical three-dimensional dextran concentration. The measurements in dilute agarose gel provided a reference value of D and validated the method. Values of the tortuosity, lambda = (D/D*)1/2, for the 3- and 10-kDa dextrans were 1.70 and 1.63, respectively, which were consistent with previous values derived from tetramethylammonium measurements in cortex. Tortuosities for the 40- and 70-kDa dextrans had significantly larger values of 2.16 and 2.25, respectively. This suggests that the extracellular space may have local constrictions that hinder the diffusion of molecules above a critical size that lies in the range of many neurotrophic compounds.

Animals↗

Long-term optical imaging and spectroscopy reveal mechanisms underlying the intrinsic signal and stability of cortical maps in V1 of behaving monkeys.

Explorations of learning and memory, other long-term plastic changes, and additional cognitive functions in the behaving primate brain would greatly benefit from the ability to image the functional architecture within the same patch of cortex, at the columnar level, for a long period of time. We developed methods for long-term optical imaging based on intrinsic signals and repeatedly visualized the same functional domains in behaving macaque cortex for a period extending over 1 year. Using optical imaging and imaging spectroscopy, we first explored the relationship between electrical activity and hemodynamic events in the awake behaving primate and compared it with anesthetized preparations. We found that, whereas the amplitude of the intrinsic signal was much larger in the awake animal, its temporal pattern was similar to that observed in the anesthetized animals. In both groups, deoxyhemoglobin concentration reached a peak 2-3 sec after stimulus onset. Furthermore, the early activity-dependent increase in deoxyhemoglobin concentration (the "initial dip") was far more tightly colocalized with electrical activity than the delayed increase in oxyhemoglobin concentration, known to be associated with an increase in blood flow. The implications of these results for improvement of the spatial resolution of blood oxygenation level-dependent functional magnetic resonance imaging are discussed. After the characterization of the intrinsic signal in the behaving primate, we used this new imaging method to explore the stability of cortical maps in the macaque primary visual cortex. Functional maps of orientation and ocular dominance columns were found to be stable for a period longer than 1 year.

Anesthesia↗

Optical image reconstruction using DC data: simulations and experiments.

In this paper, we explore optical image formation using a diffusion approximation of light propagation in tissue which is modelled with a finite-element method for optically heterogeneous media. We demonstrate successful image reconstruction based on absolute experimental DC data obtained with a continuous wave 633 nm He-Ne laser system and a 751 nm diode laser system in laboratory phantoms having two optically distinct regions. The experimental systems used exploit a tomographic type of data collection scheme that provides information from which a spatially variable optical property map is deduced. Reconstruction of scattering coefficient only and simultaneous reconstruction of both scattering and absorption profiles in tissue-like phantoms are obtained from measured and simulated data. Images with different contrast levels between the heterogeneity and the background are also reported and the results show that although it is possible to obtain qualitative visual information on the location and size of a heterogeneity, it may not be possible to quantitatively resolve contrast levels or optical properties using reconstructions from DC data only. Sensitivity of image reconstruction to noise in the measurement data is investigated through simulations. The application of boundary constraints has also been addressed.

Absorption↗

Separating spatially distributed response to stimulation from background. I. Optical imaging.

We consider the problem of estimating a small stimulus-induced response to stimulation that is masked by a fluctuating background when measurements of the background in the absence of stimulation are available, as is common in optical imaging of the cortex and in many other experimental situations. Two related methods based on the Karhunen-Loève procedure are discussed. One seeks the function, an indicator function, that is most parallel to the response data and most orthogonal to the background data. The second removes the subspace spanned by the background from the response. Numerical investigations on simulated optical imaging data show that the first method is generally superior. Connections between the two methods and techniques for assessing the quality of the result are discussed.

Artifacts↗