Performance measurements of an infrared digital scanning laser ophthalmoscope.

Direct digital acquisition of images using a scanning laser ophthalmoscope (SLO) offers several advantages over the conventional fundus camera; in particular, the ability to produce tomographic images using a confocal aperture. This note describes measurements of the performance of an SLO. Spatial resolution, measured by the modulation transfer function, MTF, was shown to be worse along the direction of scan. As expected, image uniformity was good, with a coefficient of variation of 1.9%. While the effect of using a 100 microns diameter confocal aperture instead of one with a 400 microns diameter was to reduce slice thickness from 2600 microns to 975 microns, image intensity was reduced by a factor of 30.

Humans↗

True colour imaging of the fundus using a scanning laser ophthalmoscope.

Currently retinal imaging is performed with the fundus camera. This has a number of limitations, in particular the high level of illuminations required for imaging. The scanning laser ophthalmoscope (SLO) has been proposed as an alternative imaging device but to date one of its main limitations has been that it gives only monochromatic images. In this paper we describe an SLO which uses low power red, green and blue lasers to image the human fundus. Using three lasers simultaneously to produce a colour image will increase the fundus exposure by a factor of three. To overcome this problem, a technique has been developed for multiplexing the lasers so that each point on the retina is imaged by the three lasers pulsed rapidly in sequence. The total exposure is thus kept to the same level as for a single laser and total imaging time is not increased. An example is shown of the image from a patient with diabetic retinopathy.

Calibration↗

Scanning eye movements in homonymous hemianopia documented by scanning laser ophthalmoscope retinal perimetry.

Sparing or partial recovery of visual fields in hemianopic patients is frequently difficult to document. This is because when testing large field losses, the standard automated or manual visual field testing systems have limited fixation controls. Measured visual field recovery in these cases may not be real but instead may be due to an artifact such as scanning eye movement. This article illustrates a way to separate the actual visual field sparing from scanning eye movement artifact by using perimetry testing with the scanning laser ophthalmoscope (SLO). During the SLO perimetry, the examiner has a direct and magnified view of the retinal fixation locus. This direct view allows for the added ability to monitor the fixation stability during target presentation. When eye movements larger than 1 degrees are noted, the examiner can repeat the trial. During static perimetry, our SLO records the retinal position of the fixation target at the end of the stimulus presentation and corrects scanning eye movements that occur during stimulus presentation. These special features enable us to identify when the apparent sparing of the visual field is due to the artifact of scanning. To demonstrate this, we selected the records of four hemianopic patients whose fields were examined by both standard perimetry and the SLO. We then compared the clinical visual fields with the SLO perimetry fields. One of the patients had a complete homonymous hemianopia on both the clinical perimetry and the SLO perimetry. A second patient was found by the SLO to have unstable fixation during testing. The SLO perimetry revealed that the apparent spared fields seen in standard perimetry were the result of eye scanning and not an actual enlargement of the visual field. Two other patients were confirmed by the SLO findings to have valid partial recovery of the visual field, one with and one without scanning eye movements. The advantages and limitations of SLO perimetry in analyzing hemianopic field sparing are discussed.

Adolescent↗

Distortion and size calibration of the scanning laser ophthalmoscope (SLO) laser-beam raster.

PURPOSE: The Rodenstock scanning laser ophthalmoscope (SLO) is useful for mapping retinal function and for developing and evaluating visual rehabilitation methods. It is essential to know the visual angle subtended by stimuli in the SLO laser-beam raster and to accurately measure angular distances between objects in the final SLO image. To accomplish this, the angular extent of the SLO laser-beam raster must be calibrated. METHODS: We developed a simple method and apparatus for calibrating the raster and used it for repeated calibrations during a 3-month period. RESULTS: The laser-beam raster is quite stable in shape and size, but it is trapezoidally distorted in the vertical direction. Consequently, SLO images are distorted. CONCLUSIONS: Trapezoidal distortion of the SLO laser-beam raster can cause stimulus size to change as much as 10% from the top to the bottom of the raster. Measurements of fixed horizontal retinal landmark distances in SLO images can also vary as much as 10%. We developed a straightforward mathematical method for correcting distortion in SLO image measurements.

Calibration↗

Accommodative and vergence difficulties interfering with image clarity through a binocular indirect ophthalmoscope.

PURPOSE: This study sought to identify accommodative and vergence deficiencies that could explain why some students have difficulty seeing clearly when using a binocular indirect ophthalmoscope (BIO) containing its standard +2.00 D lenses. METHODS: A survey was distributed to Illinois College of Optometry 3rd- and 4th-year students. Based on the information supplied by the survey, students were divided into two groups: those who are unable ("BIO plano") and those who are able ("BIO plus") to obtain a clear image with the +2.00 D lenses in their BIO's. Forty-seven subjects participated: 22 in the BIO plano group and 25 in BIO plus group. Two of the authors, masked to subject group, measured all subjects' accommodative amplitudes and facilities, monocular estimation method (MEM) retinoscopy, negative relative accommodation and positive relative accommodation (NRA/PRA), distance and near vergence ranges, distance and near phorias, Worth 4-dot test, and near point of convergence (five times). RESULTS: The Mann-Whitney U analysis of numerical data for the two groups showed a statistically significant difference for accommodative facility in the right eye (p = 0.004). The difference between the two groups approached significance for accommodative facility with both eyes (p = 0.02), facility in the left eye (p = 0.03), distance base-out blur (p = 0.02), near base-out break (p = 0.02), and near base-out recovery (p = 0.04). For all findings in which the difference between the two groups was significant or approached significance, the BIO plus group had higher median values. When subjects were classified by difficulty with the plus side of the flippers during accommodative facility testing, there was a statistically significant difference with both eyes (Fisher exact test, p = 0.003) and with the right eye (p = 0.008) between the BIO plus and BIO plano groups. When subjects were classified by the presence or absence of an accommodative or binocular vision syndrome, categorical data analysis showed the difference between the two groups approached significance, with more BIO plano subjects having syndromes (p = 0.03). CONCLUSION: No one test absolutely defined who would have difficulty with the +2.00 D lenses in the BIO. There are several skills required; less developed plus acceptance and convergence may cause difficulties.

Accommodation, Ocular↗

A new magnifying indirect stereo ophthalmoscope.

A new magnifying indirect stereo ophthalmoscope had been designed, built, and tested. Magnification is achieved by means of Keplerian telescopic systems mounted in each eyepiece. Schmidt or Pechan prisms are incorporated to shorten the length of the telescopic systems. Using a +20 diopter condensing lens, the total retinal magnification achieved with this system varies from 5.6x at a 40-cm observation distance to the aerial image to 9.4x at a 25-cm observation distance. When the fundus is viewed through a dilated pupil extraordinary stereopsis is obtained. When combined with the magnification, this stereopsis greatly enhances the view of the posterior segment of the eye.

Depth Perception↗

Disparity between fundus camera and scanning laser ophthalmoscope indocyanine green imaging of retinal pigment epithelium detachments.

PURPOSE: Indocyanine green (ICG) angiograms of each of five patients with retinal pigment epithelium (RPE) detachments were made using first a Topcon fundus camera and then a Heidelberg scanning laser ophthalmoscope (SLO); for each patient, both types of angiograms were obtained on the same day. In each case, the serous fluid appeared bright throughout the fundus camera studies and dark throughout the SLO studies. This study sought to explain the disparity in the appearance of the lesions in the two kinds of images and to determine whether there was dye in the serous fluid. METHODS: Simple model eyes were constructed to demonstrate the effects of Mie light scatter and integrating sphere behavior of the sclera on ICG image formation by the fundus camera and SLO optics. Analysis was made of both the clinical angiograms and model eye images to structure an explanation for the disparate RPE detachment angiographic images. RESULTS: Indocyanine green fluorescent light from choroidal vessels adjacent to the lesions and scattered by the turbid serous fluid accounted for the lesion brightness seen in the fundus camera images. The models confirmed that SLOs suppress scattered light. CONCLUSIONS: The apparent fluorescence of serous fluid beneath RPE detachments in fundus camera early-phase ICG angiogram images is not attributable to the presence of dye; rather, it appears to be attributable to serous fluid light scatter of fluorescent light arising from adjacent fluorescent structures. This light scatter is a consequence of the fundus camera illumination and recording optics and is not present in SLO-generated images. The necessity of understanding such phenomena as absorption, diffraction, polarization, and scatter of light and routinely applying them to ICG angiogram interpretation is underscored when it is shown that they offer simple explanations for unusual or unexpected angiographic results, as in the case of the patients with RPE detachment discussed here.

Fluorescein Angiography↗

Hemodynamic changes in two patients with retinal circulatory disturbances shown by fluorescein angiography using a scanning laser ophthalmoscope.

PURPOSE: To assess hemodynamic changes in two patients with severely affected retinal circulation. METHODS: A 62-year-old man with central retinal artery occlusion and a 46-year-old woman with branch retinal vein occlusion were studied by fluorescein angiography with a scanning laser ophthalmoscope (SLO). Fluorescein angiography with SLO revealed hypofluorescent clumps of different sizes and hyperfluorescent dots in large retinal vessels. The velocities of the hypofluorescent clumps were calculated between two points on the same vessel, and movements of the hypofluorescent clumps and the hyperfluorescent dots were investigated. RESULTS: The velocities of the hypofluorescent clumps were slow and varied in the same vessel. The velocities of the hypofluorescent clumps increased at the sites with narrow calibers. The hypofluorescent clumps occasionally changed size in the bloodstream. The hypofluorescent clumps flowed along the walls of retinal vessels. Distance between consecutive hypofluorescent clumps was wide. Some vessels filled with hypofluorescent clumps were also detected. Rolling hyperfluorescent dots were seen in fluorescent plasma. CONCLUSIONS: The hypofluorescent clumps were concluded to be packed erythrocytes and the hyperfluorescent dots corresponded to leukocytes and platelets moving in the vessels. Fluorescein angiography with SLO is a useful method for evaluating hemodynamic changes using the hypofluorescent clumps in severely affected retinal circulation.

Blood Flow Velocity↗

Extraction of fluorescent dot traces from a scanning laser ophthalmoscope image sequence by spatio-temporal image analysis: Gabor filter and radon transform filtering.

The scanning laser ophthalmoscope (SLO) allows the tracking of fluorescent dot motion, thereby enabling the flow velocities in perimacular capillaries to be directly measured. These can serve as an important index of local retinal soundness or reflect the whole body circulation status in disorders such as diabetes. Although it is possible to perceive moving fluorescent dots with the human eye, they are so faint and unstable that it is difficult to detect them by conventional digital still-image processing methods. To solve this problem, we generated spatio-temporal images of the fluorescent dots in a capillary and applied Gabor filters tuned to the direction of the traces in order to detect them. Finally, by discriminating and integrating the output using two levels of threshold, we were able to extract their traces. Because the medium-size Gabor filter requires a considerable amount of time for two-dimensional convolution calculation, we prove that there is a certain equivalence between the Gabor filter, the radon transform, and the Hough transform. In the light of this, we propose a form of radon transform filtering that includes a radon transform Gabor filter as a very long Gabor filter. This allows a whole trace to be detected in a single step with a one-dimensional convolution, thereby shortening the processing time. In an experiment, 60% of the traces could be detected without error, which is sufficient to allow the mean flow velocity in a capillary to be measured.

Filtration↗

Use of a confocal laser scanning ophthalmoscope to detect glaucomatous cupping of the optic disc.

PURPOSE: The aim of the present study was to test the hypothesis that the three-dimensional (3-D) topography of the optic disc contains sufficient information to diagnose glaucoma with a high degree of reliability. METHODS: The Zeiss 'Confocal Laser Scanning Ophthalmoscope' (CLSO) was used to obtain digitized samples of 3-D images of optic nerve heads from the following three groups of patients: (i) 40 normals with normal optic discs, normal Humphrey 24-2 full threshold visual fields and an intraocular pressure (IOP) < or = 21 mmHg, (ii) 20 established glaucoma patients with cupping, glaucomatous field loss and an IOP > 21 mmHg; and (iii) 20 early glaucoma patients with early cupping, field loss with a mean defect less than -10 dB and IOP > 21 mmHg. The cupping in these patients was paramaterized by spherical harmonics and was classified by multivariate statistical analysis. RESULTS: Of 40 glaucoma patients, 39 were correctly classified. Of 40 normal patients one was classified as glaucoma. CONCLUSIONS: This study demonstrates that the CLSO, with the use of spherical harmonics, can differentiate glaucomatous from normal optic discs in this selected group of patients without the need for a skilled observer. This constitutes a promising technique to be tested on a large, unselected body of patients as a screening tool.

Adult↗

Assessment of optic nerve head topographic parameters with a confocal scanning laser ophthalmoscope.

AIM: To assess the disc area, age, sex, laterality (side of the eyes) and refractive error dependent differences in optic nerve head topographic parameters in a normal population. METHODS: Optic nerve head topographic analysis of both eyes of 551 healthy Turkish subjects aged 11-75 years (1102 eyes) was performed using a confocal scanning laser ophthalmoscope, the Heidelberg Retinal Tomograph II (HRT II). The effects of disc size, sex, laterality (side of the eyes), age and refractive error on optic nerve head topographic parameters were assessed. Subjects were divided into three different age groups (<30 years, 30-60 years, >60 years) and three different disc area groups (<2.00 mm(2), 2.00-2.25 mm(2), >2.25 mm(2)). Disc area, topography standard deviation and a total of 12 topographic parameters were calculated by HRT II for each subject. Statistical analysis was performed using Student's t-test, multiple regression analysis, Tukey-HSD test, anova and Pearson's correlation coefficient. RESULTS: A total of 543 subjects (298 women and 245 men) were included in the study. The mean disc area of the subjects was 2.12 +/- 0.47 mm(2) (range 1.16-4.98 mm(2)). The mean refractive error of the subjects was -0.58 +/- 1.71 D (range -4.75 D to +4.25 D). The mean cup shape measure was -0.21 +/- 0.07 (95% confidence interval -0.07 to -0.35). The disc area was significantly correlated with all of the topographic parameters but two; namely, the cup shape measure and the height variation contour. Significant age-related differences were detected in four parameters (mean retinal nerve fibre layer [RNFL] thickness, disc area, cup-to-disc area ratio, cup area) and significant sex-related differences were detected three parameters (mean RNFL thickness, height variation contour, RNFL cross-sectional area). However, there were no significant differences in any of the parameters for laterality and refractive error. The parameter cup shape measure did not correlate with any of the five variables investigated. CONCLUSION: Cup shape measure was the only optic nerve head topographic parameter that was independent of age, sex, disc area, laterality and the refractive error. It seems to be a promising parameter in evaluation and comparison of the optic discs of normal subjects, with different disc area, age, sex, refraction error and laterality, as being independent of the main variation factors of the disc topography.

Adolescent↗

Comparative evaluation of oral fluorescein angiography using the confocal scanning laser ophthalmoscope and digital fundus camera with intravenous fluorescein angiography using the digital fundus camera.

BACKGROUND: To study the efficacy of oral fluorescein angiography (FA) with confocal scanning laser ophthalmoscope (CSLO). METHODS: Ten patients each of choroidal neovascular membrane, central serous retinopathy, diabetic retinopathy and five normal subjects were evaluated with group 1 - intravenous FA using digital fundus camera (DFC); group 2 - oral FA using DFC; and group 3 - oral FA using CSLO. RESULTS: Third-order branch vessels were identified in 85.7% eyes in group 3 versus 51.4% in group 2 (P = 0.004), image quality was comparable to intravenous FA in 77.1% in group 3 versus 48.5% in group 2 (P = 0.02) and margin delineation was better in 80% eyes in group 3 versus 35% in group 2 (P = 0.01). The foveal avascular zone was clear and intact in 54.2% eyes in group 3 versus 37.1% in group 2 (P = 0.14) and 57.1% in group 1 (P = 0.8). CONCLUSION: Oral FA using CSLO is superior to oral FA using DFC and comparable to intravenous FA using DFC in terms of image quality, branch retinal vessel identification and margin delineation.

Administration, Oral↗

Scanning Laser Ophthalmoscope microperimetry compared with Octopus perimetry in normal subjects.

Simultaneously performed ophthalmoscopy and perimetry by microperimetry using the Scanning Laser Ophthalmoscope eliminates some of the classical problems involved in transformation techniques in perimetry such as: optical distortions, unsteady fixation and alignment. Almost all reports published on microperimetry have addressed chorioretinal diseases, with only a few patients in each study. No reports have studied the normal values of this method. To evaluate the reliability of microperimetry, 30 healthy subjects-10 subjects from each of the age group: 40-49 years (male/female ratio: 4/6), 50-59 years (m/f ratio: 5/5) and 60-69 years (m/f ratio: 5/5)-were repeatedly examined with microperimetry and automatic perimetry performed by the Octopus macular program M1. The results of the present study of microperimetry show that the standard deviation of the interindividual variance component was 1.36, that the standard deviation of the intraindividual variance component was 0.94 and that a test result obtained by microperimetry in any of the two locations studied can be related to a test result obtained by Octopus M1 in the same location.

Adult↗

The locus of fixation in strabismic amblyopia changes with increasing effort of recognition as assessed by scanning laser ophthalmoscope.

PURPOSE: We performed a qualitative assessment of fixation behaviour in relation to the fovea in patients with strabismic amblyopia. METHODS: The fixation of 25 patients with strabismic amblyopia was examined using a scanning laser ophthalmoscope (SLO). A digital frame grabber board was programmed to scan onto the patient's retina single solid black discs of 5, 10 and 15 degrees in diameter and Landolt Cs in different orientations and corresponding to a visual acuity (VA) of 0.01-0.2 in European decimals. The relative position of the fovea was video-recorded. Fifty video fields per second were plotted as x/y (fixational positions in relation to the fovea) and x/t (motion over time) graphs. RESULTS: Three main groups of patients were seen. Group 1 (n = 6), with a VA of < 0.1, showed a grossly eccentric and unstable locus of fixation independent of size/type of test stimulus used. Group 2 (n = 15), with VA of 0.1-0.8, initially used an eccentric retinal area for fixation that, however, shifted to the fovea with decreasing size and increasing detail of the target for fixation. Group 3 (n = 4), with VA of 0.3-0.8, had stable central fixation throughout. CONCLUSIONS: We speculate that the reduced VA associated with strabismic amblyopia is due to a defective motor control of fixation that can be modulated by recognitional effort.

Adolescent↗

Recording pattern reversal visual evoked response with the scanning laser ophthalmoscope.

We recorded visual evoked responses (VERs) to alternating, checkerboard pattern stimuli using the scanning laser ophthalmoscope (SLO). Retinal position and focus of checkerboard stimuli were monitored on the SLO video monitor throughout testing. Checkerboard size, check size, and retinal positions were varied. Consistent with other, well-established pattern reversal techniques, the SLO method produced: 1) reliable VERs with amplitudes of 2 to 10 microvolts, 2) maximum amplitudes at an intermediate check size for a fixed overall pattern size, and 3) variations in VER amplitude depending on stimulus retinal position relative to the fovea. Hence, the SLO-VER technique would be useful for clinical VER measurements when precise retinal stimulus position and focus are desired.

Computer Systems↗

Theoretical modeling and evaluation of the axial resolution of the adaptive optics scanning laser ophthalmoscope.

We present axial resolution calculated using a mathematical model of the adaptive optics scanning laser ophthalmoscope (AOSLO). The peak intensity and the width of the axial intensity response are computed with the residual Zernike coefficients after the aberrations are corrected using adaptive optics for eight subjects and compared with the axial resolution of a diffraction-limited eye. The AOSLO currently uses a confocal pinhole that is 80 microm, or 3.48 times the width of the Airy disk radius of the collection optics, and projects to 7.41 microm on the retina. For this pinhole, the axial resolution of a diffraction-limited system is 114 microm and the computed axial resolution varies between 120 and 146 microm for the human subjects included in this study. The results of this analysis indicate that to improve axial resolution, it is best to reduce the pinhole size. The resulting reduction in detected light may demand, however, a more sophisticated adaptive optics system. The study also shows that imaging systems with large pinholes are relatively insensitive to misalignment in the lateral positioning of the confocal pinhole. However, when small pinholes are used to maximize resolution, alignment becomes critical.

Computer Simulation↗

Evaluating the lateral resolution of the adaptive optics scanning laser ophthalmoscope.

We present a statistical assessment of the lateral resolution of the adaptive optics scanning laser ophthalmoscope (AOSLO). We adopt a 2-D Gaussian function to approximate the AOSLO point spread function (PSF), which is dominated by the residual wavefront aberration and characterized by the Strehl ratio. Thus, we derive the lateral resolution in the presence of residual wave aberrations, which is inversely proportional to square root of the Strehl ratio. The modeling, while not sufficient in describing the fine structure of the real PSF, demonstrates good conformance to the lateral cross section of the real PSF. With this model, the lateral resolution of our current AOSLO was computed to be 1.65 to 2.33 microm, which agreed well with the actual result. We also reveal the relationships among the lateral resolution and other three measures of the AOSLO imaging property including the Strehl ratio, the PSF, and the root mean square (rms) of wavefront aberration.

Benchmarking↗

Line-scanning laser ophthalmoscope.

Scanning laser ophthalmoscopy (SLO) is a powerful imaging tool with specialized applications limited to research and ophthalmology clinics due in part to instrument size, cost, and complexity. Conversely, low-cost retinal imaging devices have limited capabilities in screening, detection, and diagnosis of diseases. To fill the niche between these two, a hand-held, nonmydriatic line-scanning laser ophthalmoscope (LSLO) is designed, constructed, and tested on normal human subjects. The LSLO has only one moving part and uses a novel optical approach to produce wide-field confocal fundus images. Imaging modes include multiwavelength illumination and live stereoscopic imaging with a split aperture. Image processing and display functions are controlled with two stacked prototype compact printed circuit boards. With near shot-noise limited performance, the digital LSLO camera requires low illumination power (<500 microW) at near-infrared wavelengths. The line-scanning principle of operation is examined in comparison to SLO and other imaging modes. The line-scanning approach produces high-contrast confocal images with nearly the same performance as a flying-spot SLO. The LSLO may significantly enhance SLO utility for routine use by ophthalmologists, optometrists, general practitioners, and also emergency medical personnel and technicians in the field for retinal disease detection and other diverse applications.

Computer-Aided Design↗