Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAGNETICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Sextant localization of prostate cancer: comparison of sextant biopsy, magnetic resonance imaging and magnetic resonance spectroscopic imaging with step section histology.

PURPOSE: We compared the accuracy of endorectal magnetic resonance imaging (MRI) and magnetic resonance spectroscopic imaging with that of sextant biopsy for the sextant localization of prostate cancer. MATERIALS AND METHODS: Sextant biopsy, MRI, magnetic resonance spectroscopic imaging and radical prostatectomy with step section histology were done in 47 patients with prostate cancer. For each sextant we categorized biopsy and imaging results as positive or negative for cancer. Step section histology was used as the standard of reference. RESULTS: For sextant localization of prostate cancer MRI and magnetic resonance spectroscopic imaging were more sensitive but less specific than biopsy (67% and 76% versus 50%, and 69% and 68% versus 82%, respectively). The sensitivity of sextant biopsy was significantly less in the prostate apex than in the mid prostate or prostate base (38% versus 52% and 62%, respectively). MRI and magnetic resonance spectroscopic imaging had similar efficacy throughout the prostate compared with biopsy only as well as better sensitivity and specificity in the prostate apex (60% and 75%, and 86% and 68%, respectively). A positive biopsy or imaging result had 94% sensitivity for cancer and concordant positivity by all 3 tests was highly specific at 98%. CONCLUSIONS: Overall MRI and magnetic resonance spectroscopic imaging have accuracy similar to biopsy for intraprostatic localization of cancer and they are more accurate than biopsy in the prostate apex. These 2 imaging modalities may supplement biopsy results by increasing physician confidence when evaluating intraprostatic tumor location, which may be important for planning disease targeted therapy.

Aged↗

[From nuclear magnetic resonance to magnetic resonance imaging].

Magnetic resonance imaging is based upon the phenomenon of nuclear magnetic resonance. The patient is placed in a magnet the provides a strong magnetic field inducing a net magnetization due to hydrogen nuclei inside biological tissues. The image is formed from the localized measurement of this magnetization by means of radio-frequency waves. The contrast is a function of the number of hydrogen nuclei and of the time characteristics T1 and T2 of the return to equilibrium. Many other parameters can be measured by this method and the permanent improvement of the technique will extend further the field of its medical application.

Forecasting↗

Static magnetic field measurements in residences in relation to resonance hypotheses of interactions between power-frequency magnetic fields and humans.

Bowman et al. used epidemiologic data to test a model in which subjects were classified as being "in-resonance" or "not-in-resonance" for 60-Hz magnetic-field exposures depending on single static magnetic-field measurements at the centers of their bedrooms. A second paper by Swanson concluded that a single static magnetic-field measurement is insufficient to meaningfully characterize a residential environment. The main objective of this study was to investigate exposure-related questions raised by these two papers in two U.S. data sets, one containing single spot measurements of static magnetic fields at two locations in homes located in eight states, and the other repeated spot measurements (seven times during the course of one year) of the static magnetic fields at the centers of bedrooms and family rooms and on the surfaces of beds in 51 single-family homes in two metropolitan areas. Using Bowman's criterion, bedrooms were first classified as being in-resonance or not-in-resonance based on the average of repeated measurements of the static magnetic field measured on the bed where the presumed important exposure actually occurred. Bedrooms were then classified a second time using single spot measurements taken at the centers of bedrooms, centers of family rooms, or on the surfaces of beds, as would be done in the typical epidemiologic study. The kappa statistics characterizing the degree of concordance between the first (on-bed averages) and second (spot measurements) methods of assessing resonance status were 0.44, 0.33, and 0.67, respectively. This level of misclassification could significantly affect the results of studies involving the determination of resonance status.

Adolescent↗

Direct observation of the magnetization exchange dynamics responsible for magnetization transfer contrast in human cartilage in vitro.

Saturating irradiation far off-resonance can lead to diminution in the water signal seen in MRI, giving rise to magnetization transfer contrast. This results from transfer of magnetization between "solid" protons with restricted motion, which give rise to a band some tens of kilohertz wide, and the narrow signal from mobile protons. In the work reported here a high-power pulse spectrometer, which can detect signals from both mobile and immobile protons, was used to investigate the dynamics of magnetization transfer in cartilage in vitro. Magnetization transfer in modified Hoffman-Forsén inversion transfer experiments was well-described by a single rate constant model; full analytical solutions are offered for the resultant biexponential magnetization recovery curves. The use of pulsed methods to generate magnetization contrast may in some circumstances offer advantages over the steady-state saturation methods used hitherto.

Adult↗

Magnetic resonance imaging and magnetization transfer in experimental myonecrosis in the rat.

Experimental myonecrosis--induced by injection of notexin into rat tibialis anterior muscle--and subsequent regeneration were studied from 1 h to 20 days postinjury with magnetic resonance imaging using conventional and magnetization transfer sequences, and these findings were correlated with histopathology. MR images revealed necrosis within 1 h postinjection. Histopathologically, necrotized fibers enlarged and intercellular spaces widened, indicating intracellular and extracellular edema, which began to decrease after 48 h, whereafter the formation of new myofibers predominated. T2 increased progressively until 7.5 h, while T1 increased until 24 h. Magnetization transfer contrast (MTC) and magnetization transfer rate (Rwm) decreased rapidly postinjection; the decrease in Rwm lasted longer than in MTC (96 h versus 48 h, respectively). Spin echo, inversion recovery and magnetization transfer sequences revealed the lesions equally effectively. MR images and relaxation parameters reflect well the extent of histopathological injury and edema in the acute phase, whereas specific tissue changes in the regenerative phase were not detectable by MRI. MT imaging and especially magnetization transfer rate are as sensitive as conventional T2 contrast to alterations in water imbalance.

Animals↗

Magnetic field interactions of orthodontic wires during magnetic resonance imaging (MRI) at 1.5 Tesla.

BACKGROUND: Orthodontic appliances pose a potential risk during magnetic resonance imaging (MRI) due to forces on metallic objects within the static magnetic field of MRI systems. The aim of the present investigation was to measure forces on orthodontic wires caused by the static magnetic field of a 1.5-Tesla MRI system, and to assess the safety hazards associated with these forces. MATERIALS AND METHODS: Thirty-two different orthodontic wires (21 arch wires, eight ligature wires and three retainer wires) were investigated in a 1.5-Tesla MRI system (Magnetom Symphony, Siemens Medical Solutions, Erlangen, Germany). The translational forces were measured using the deflection angle test (ASTM F2052-02); rotational forces were assessed on a 5-point qualitative scale. RESULTS AND CONCLUSION: All retainer wires and the steel arch wires (the Noninium arch wire being the exception) were subjected to considerable rotational and translational forces within the MRI system's magnetic field. Translational forces were from 9.1- to 27.6-times as high as gravitational forces on these objects. Steel ligature wires and arch wires made of cobalt chromium, titanium molybdenum, nickel-titanium, and brass alloys showed no or negligible forces within the magnetic field. The translational and rotational forces within the MRI magnetic field should pose no risk to carefully-ligated arch wires. Steel retainer wire bonds should be checked to ensure secure attachment prior to an MRI investigation.

Biocompatible Materials↗

Comparative disposition of adriamycin delivered via magnetic albumin microspheres in presence and absence of magnetic field in rats.

The multiple tissue disposition of adriamycin hydrochloride delivered via magnetic albumin microspheres, in absence (control) and presence of magnetic field (experimental), has been investigated in rats. The animal tail was demarcated into three segments: T1, the dosing-site; T2, the target-site; and T3, the post target-site. Following the arterial cannulation at T1, 0.4 mg/kg of microsphere associated drug was administered to the control as well as the experimental animals. In experimental group, the target-site T2 was exposed to a 8000 G magnetic field for 30 min. In both groups the animals were sacrificed in triplicates over a 48 hr period and their various tissues monitored for drug concentrations using HPLC. In presence of magnetic field, the microspheres demonstrated 16 fold increase in the maximum drug concentration, 6 fold increase in drug exposure and 6 fold increase in the drug targeting efficiency for T2. Drug delivery to most non-target tissues, including heart and liver, was substantially reduced. The results quantitatively suggest that the efficacy of magnetic albumin microspheres in the targeted delivery of incorporated therapeutic agent is predominantly due to the magnetic effects, and not alone due to the characteristics of the micro-carrier system.

Albumins↗

Magnetic material arrangement in oriented termites: a magnetic resonance study.

Temperature dependence of the magnetic resonance is used to study the magnetic material in oriented Neocapritermes opacus (N.o.) termite, the only prey of the migratory ant Pachycondyla marginata (P.m.). A broad line in the g = 2 region, associated to isolated nanoparticles shows that at least 97% of the magnetic material is in the termite's body (abdomen + thorax). From the temperature dependence of the resonant field and from the spectral linewidths, we estimate the existence of magnetic nanoparticles 18.5+/-0.3 nm in diameter and an effective magnetic anisotropy constant, K(eff) between 2.1 and 3.2 x 10(4)erg/cm(3). A sudden change in the double integrated spectra at about 100K for N.o. with the long body axis oriented perpendicular to the magnetic field can be attributed to the Verwey transition, and suggests an organized film-like particle system.

Abdomen↗

A multivariate approach for processing magnetization effects in triggered event-related functional magnetic resonance imaging time series.

Triggered event-related functional magnetic resonance imaging requires sparse intervals of temporally resolved functional data acquisitions, whose initiation corresponds to the occurrence of an event, typically an epileptic spike in the electroencephalographic trace. However, conventional fMRI time series are greatly affected by non-steady-state magnetization effects, which obscure initial blood oxygen level-dependent (BOLD) signals. Here, conventional echo-planar imaging and a post-processing solution based on principal component analysis were employed to remove the dominant eigenimages of the time series, to filter out the global signal changes induced by magnetization decay and to recover BOLD signals starting with the first functional volume. This approach was compared with a physical solution using radiofrequency preparation, which nullifies magnetization effects. As an application of the method, the detectability of the initial transient BOLD response in the auditory cortex, which is elicited by the onset of acoustic scanner noise, was used to demonstrate that post-processing-based removal of magnetization effects allows to detect brain activity patterns identical with those obtained using the radiofrequency preparation. Using the auditory responses as an ideal experimental model of triggered brain activity, our results suggest that reducing the initial magnetization effects by removing a few principal components from fMRI data may be potentially useful in the analysis of triggered event-related echo-planar time series. The implications of this study are discussed with special caution to remaining technical limitations and the additional neurophysiological issues of the triggered acquisition.

Artifacts↗

Comparative study of the surface characteristics, microstructure, and magnetic retentive forces of laser-welded dowel-keepers and cast dowel-keepers for use with magnetic attachments.

STATEMENT OF PROBLEM: Information regarding the merits and problems associated with connecting a keeper to a dowel and coping using a laser welding technique has not been explored extensively in the dental literature. PURPOSE: This in vitro study compared the surface characteristics, microstructure, and magnetic retentive forces for a dowel and coping-keeper mechanism fabricated using a laser welding process and a cast-to casting technique. MATERIAL AND METHODS: Five cast-to and 6 laser-welded dowel and coping-keeper specimens were tested. Using 5 freestanding keepers as the control group, the surface characteristics and microstructures of the specimens were examined by means of stereomicroscopy, metallographic microscopy, and scanning electron microscopy (SEM). Energy-dispersive spectroscopic (EDS) microanalysis with SEM provided elemental concentration information for the test specimens. The vertical magnetic retentive forces (N) of the 3 groups were measured using a universal testing machine. The results were statistically compared using 1-way analysis of variance and the Newman-Keuls multiple range test (alpha =.05). RESULTS: The laser-welded dowel-keeper generally maintained its original surface smoothness as well as the original microstructure. Elements diffused readily through the fusion zone. The surface of the cast dowel-keeper became rough with the formation of an oxide layer, the microstructure changed, and there was only limited elemental diffusion in the fusion zone. The average vertical magnetic retentive force of the laser-welded group, the cast group, and the control group were 4.2 +/- 0.2 N, 3.8 +/- 0.3 N, and 5.6 +/- 0.3 N, respectively. Statistically significant differences in vertical magnetic retentive force were found between the control group and both the laser-welded and cast groups (P <.01). Compared with the cast dowel-keepers, the average vertical magnetic retentive force of the laser-welded dowel-keepers was significantly higher (P <.05). CONCLUSION: The laser welding technique had less influence on the surface characteristics, the microstructure, and the magnetic retentive forces of keepers relative to techniques that incorporate a keeper at the time of cast dowel and coping fabrication.

Dental Prosthesis Retention↗

Application of magnetic agarose support in liquid magnetically stabilized fluidized bed for protein adsorption.

A novel magnetic agarose support (MAS) was fabricated for application in a liquid magnetically stabilized fluidized bed (MSFB). It was produced by water-in-oil emulsification method using a mixture of agarose solution and nanometer-sized superparamagnetic Fe(3)O(4) particles as the aqueous phase. The MAS showed good superparamagnetic responsiveness in a magnetic field. A reactive triazine dye, Cibacron blue 3GA (CB), was coupled to the gel to prepare a CB-modified magnetic agarose support (CB-MAS) for protein adsorption. Lysozyme was used as a model protein to test the adsorption equilibrium and kinetic behavior of the CB-MAS. The dependence of bed expansion in the MSFB with a transverse magnetic field on liquid velocity and magnetic field intensity was investigated. Liquid-phase dispersion behavior in the MSFB was examined by measurements of residence time distributions and compared with that obtained in packed and expanded beds. Dynamic lysozyme adsorption in the MSFB was also compared with those in packed and expanded beds. The dynamic binding capacity at 10% breakthrough was estimated at 55.8 mg/mL in the MSFB, higher than that in the expanded bed (31.1 mg/mL) at a liquid velocity of 45 cm/h. The results indicate that the CB-MAS is promising for use in liquid MSFB for protein adsorption.

Adsorption↗

Magnetic nanotubes for magnetic-field-assisted bioseparation, biointeraction, and drug delivery.

Tubular structure of nanoparticles is highly attractive due to their structural attributes, such as the distinctive inner and outer surfaces, over conventional spherical nanoparticles. Inner voids can be used for capturing, concentrating, and releasing species ranging in size from large proteins to small molecules. Distinctive outer surfaces can be differentially functionalized with environment-friendly and/or probe molecules to a specific target. Magnetic particles have been extensively studied in the field of biomedical and biotechnological applications, including drug delivery, biosensors, chemical and biochemical separation and concentration of trace amounts of specific targets, and contrast enhancement in magnetic resonance imaging (MRI). Therefore, by combining the attractive tubular structure with magnetic property, the magnetic nanotube (MNT) can be an ideal candidate for the multifunctional nanomaterial toward biomedical applications, such as targeting drug delivery with MRI capability. Here, we successfully synthesized magnetic silica-iron oxide composite nanotubes and demonstrated the magnetic-field-assisted chemical and biochemical separations, immunobinding, and drug delivery.

Animals↗

Millimeter scale alignment of magnetic nanoparticle functionalized microtubules in magnetic fields.

The conjugation of 14 nm diameter CoFe2O4 nanoparticles to the surface of biotinylated microtubules enables their manipulation with externally applied magnetic fields of small, permanent NdFeB magnets. Microtubules are selectively patterned on kinesin motor-modified glass surfaces in coparallel arrays that mimic the orientation of the magnetic field lines over millimeter distances. The magnetic field is simultaneously used to increase surface loading of microtubules. We demonstrate that motility across the kinesin motor surface is retained following magnetic functionalization of the microtubules, while gliding speed is dependent on loading level of the neutravidin linker as well as magnetic nanoparticles.

Animals↗

Humidity-induced magnetization and magnetic pole inversion in a cyano-bridged metal assembly.

In general, magnetic properties of bulk magnetic materials are independent of the humidity of the environment. To obtain a magnetic material that has humidity-sensitive characteristics, water vapour must penetrate the lattice and act on spin sites. Nanoporous materials composed of metal-assembled complexes may be expected to display some humidity response because materials in this category can show functionalities such as gas storage and molecular recognition. Here, we demonstrate humidity-induced reversible variations in the magnetic properties of cyano-bridged cobalt(II)-manganese(II)-chromium(III) metal assemblies. The observed magnetic humidity response is due to adsorption and desorption of a ligand water molecule on the cobalt ion, which changes cobalt (II) between a 6- and 4-fold coordination geometry and switches the magnetic interaction between ferromagnetic coupling and antiferromagnetic coupling.

Cobalt↗

A study of the magnetic properties of haem a3 in cytochrome c oxidase by using magnetic-circular-dichroism spectroscopy.

M.c.d. (magnetic-circular-dichroism) spectroscopy was used to study the magnetization properties of the haem centres in cytochrome c oxidase with magnetic fields of between 0 and 5.3 T over the temperature range 1.5--200 K. The oxidized, oxidized cyanide and partially reduced cyanide forms of the enzyme were studied. In the oxidized state only cytochrome a3+ is detectable by m.c.d. spectroscopy, and its magnetization characteristics show it to be a low-spin ferric haem. In the partially reduced cyanide form of the enzyme cytochrome a is in the diamagnetic low-spin ferrous form, whereas cytochrome a3--CN is e.p.r.-detectable and gives an m.c.d.-magnetization curve typical of a low-spin ferric haem. In the oxidized cyanide form of the enzyme both cytochrome a and cytochrome a3--CN are detectable by m.c.d. spectroscopy, although only cytochrome a gives an e.p.r. signal. The magnetization characteristics of haem a3--CN show clearly that its ground state is an electronic doublet and that another state, probably a spin singlet, lies greater than 10 cm-1 above this. These features are well accounted for by an electronic state of spin S = 1 with a predominantly axial distortion, which leaves the doublet, Ms = +/- 1, as the ground state and the component Ms = 0 as the excited state. This state would not give an e.p.r. signal. Such an electronic state could arise either from a ferromagnetic coupling between haem a3+(3)-CN and the cupric ion, Cua3, or form a haem in the Fe(IV) state.

Circular Dichroism↗

Magnetization transfer magnetic resonance imaging of parenchymal lung disease.

RATIONALE AND OBJECTIVES: Magnetic resonance imaging with magnetization transfer (MT) contrast recently has been described as a method that may provide additional information about the macromolecular composition of tissue. Magnetization transfer contrast images were compared to conventional gradient-recalled echo images in a variety of pulmonary parenchymal diseases and normal lung. METHODS: Single-slice gradient echo images were obtained with and without an off-resonance radio frequency pulse on a 0.1T MR scanner. The change in signal intensity between identical regions of interest on non-MT and MT images was determined in 13 patients with known lung disease, five healthy volunteers, and three postmortem atelectatic dog lungs. RESULTS: No significant change in signal intensity (MT effect) was observed in fat, flowing blood, normal lung, atelectatic lung, or in acute pulmonary edema. Chronic parenchymal lung disease showed the greatest MT effect, 37.7% +/- 7.5. Acute infectious lung disease showed an intermediate degree of MT effect, 19.5% +/- 3.0. CONCLUSIONS: Magnetization transfer contrast magnetic resonance imaging of pulmonary disease is feasible at low field strength and may be useful in the characterization and differentiation of pulmonary parenchymal abnormalities. Magnetization transfer contrast appears to be proportional to the amount of interstitial fibrosis in lung parenchyma, while acute inflammatory cell infiltration exhibits less MT effect and acute pulmonary edema exhibits very little.

Adult↗

A quantitative study of ramped radio frequency, magnetization transfer, and slab thickness in three-dimensional time-of-flight magnetic resonance angiography in a patient population.

RATIONALE AND OBJECTIVES: The authors compare the effectiveness of various magnetic resonance (MR) angiography acquisition strategies in enhancing the visibility of small intracranial vessels. METHODS: Blood vessel contrast-to-noise ratio (CNR) in time-of-flight MR angiography was studied as a function of vessel size and several selectable imaging parameters. Contrast-to-noise measurements were made on 257 vessel segments ranging in size from 0.3 mm to 4.2 mm in patients who recently had undergone intraarterial cerebral angiography. Imaging parameters studied included magnetization transfer, spatially variable radio frequency (RF) pulse profile (ramped RF), and imaging slab thickness. RESULTS: The combination of thin slabs (16 slices/slab), ramped RF, and magnetization transfer resulted in the highest CNR for all but the smallest vessel sizes. The smallest vessels (< 0.5 mm) had the highest CNR, using the thick slab (64 slices/slab) with ramped RF and magnetization transfer. Magnetization transfer always improved vessel CNR, but the improvement diminished as the slab thickness was reduced. The CNR increased with a decrease in slab thickness for all but the smallest vessel sizes. CONCLUSIONS: Overall, the results provide a quantitative demonstration that inflow enhancement of blood is reduced for small vessels. Thus, whereas magnetization transfer is important at all vessel sizes, it becomes the primary factor in improving the visibility of the smallest vessels.

Adult↗

Magnetic relaxation contrast agents in magnetization transfer imaging.

RATIONALE AND OBJECTIVES: The effects of magnetic relaxation agents are explored in the context of magnetization transfer pulse sequences using cross-linked protein gels as modeled tissue systems. METHODS: Magnetization transfer pulse sequences were used to study contrast agents that are designed to bind to rotationally immobilized protein targets. RESULTS: The dynamic range available from contrast agents, used in conjunction with magnetization transfer pulse sequences, is comparable with or better than that based on spin-echo imaging sequences with short repetition times. Furthermore, useful changes in the intensity of water resonances may be achieved by using this combined approach even though the paramagnetic metal center may not have a free coordination position in the chelate complex for water molecule exchange. CONCLUSIONS: The inclusion of magnetization transfer acquisition protocols in the context of magnetic imaging with contrast agents presents new opportunities for control of the information content of the image and for new classes of contrast agent structure and delivery.

Animals↗