Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Liquid Phase Microextraction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

[Determination of carbendazim and thiabendazole in tomatoes by solid-phase microextraction coupled with high performance liquid chromatography and fluorescence detection].

A novel method for the determination of carbendazim (MBC) and thiabendazole (TBZ) in tomatoes by solid-phase microextraction (SPME) coupled with high performance liquid chromatography (HPLC) and fluorescence detection was developed. The experimental conditions of SPME, including extraction fiber, extraction time, extraction temperature, desorption time, desorption solvent, desorption mode, pH value, organic solvent and ionic strength, and HPLC conditions were optimized. The SPME for MBC and TBZ was performed on a 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre for 50 min at room temperature with the solution being stirred at 1 100 r/min. The florescence detection was made at 315 nm with excitation wavelength at 280 nm. The method is linear for MBC and TBZ over the range assayed from 0.01 to 1.0 mg/kg tomatoes with the detection limits of 0.003 mg/kg and 0. 001 mg/kg and the correlation coefficients of 0.995 8 and 0.996 7, respectively. The average recoveries for MBC and TBZ were 83.5% and 85.6% with the relative standard deviations (RSDs) of 6.5% and 3.8%, respectively. The method is fast, simple, sensitive, solvent-free and suitable for the determination of MBC and TBZ in tomatoes.

Benzimidazoles↗

Determination of camptothecin and 10-hydroxycamptothecin in human plasma using polymer monolithic in-tube solid phase microextraction combined with high-performance liquid chromatography.

A biocompatible in-tube solid-phase microextraction (SPME) device was used for the direct and on-line extraction of camptothecin and 10-hydroxycamptothecin in human plasma. Biocompatibility was achieved through the use of a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column for extraction. Coupled to high performance liquid chromatography (HPLC) with UV detection, this on-line in-tube SPME method was successfully applied to the simultaneous determination of camptothecin and 10-hydroxycamptothecin in human plasma. The calculated detection limits for camptothecin and 10-hydroxycamptothecin were found to be 2.62 and 1.79 ng/mL, respectively. The method was linear over the range of 10-1000 ng/mL. Excellent method reproducibility was achieved, yielding RSDs of 2.49 and 1.59%, respectively. The detection limit (S/N = 3) of camptothecin was found to reach 0.1 ng/mL using fluorescence detection. The proposed method was shown to cope robustly with the extraction and analysis of camptothecin and 10-hydroxycamptothecin in plasma samples.

Camptothecin↗

Solid-phase microextraction coupled with high-performance liquid chromatography for the analysis of heterocyclic aromatic amines.

Solid-phase microextraction (SPME) coupled with high-performance liquid chromatography (HPLC) with UV diode array detection (DAD) for the analysis of heterocyclic aromatic amines (HAs) is described. Four kinds of fiber coatings: Carbowax-templated resin (CW-TPR), Carbowax-divinylbenzene (CW-DVB), poly(dimethylsiloxane)-divinylbenzene (PDMS-DVB) and polyacrylate (PA) were evaluated for extraction of nine most biologically active heterocyclic aromatic amines. Different parameters affecting to the microextraction and determination of HAs were studied, such as absorption and desorption time, desorption mode, composition of the solvent for desorption, pH, ionic strength, and percentage of methanol in the sample. To determine these amines in food samples a new simplified procedure is proposed, consisting of treatment of the sample with methanolic NaOH prior microextraction by CW-TPR fiber coating and HPLC-DAD determination. The advantages of this new method are the reduced amounts of time and organic solvents required.

Amines↗

Solid-phase microextraction coupled to high-performance liquid chromatography to determine phenolic compounds in water samples.

Solid-phase microextraction (SPME) coupled to high-performance liquid chromatography (HPLC) with ultraviolet (UV) and electrochemical detection (ED) has been applied to determine 11 phenolic compounds considered priority pollutants by the US Environmental Protection Agency. 85 microm polyacrylate fibers were used to extract the analytes from the aqueous samples. Two different designs of the liquid chromatograph were compared in combination with SPME. Dynamic and static modes of desorption in both HPLC designs were compared and the variables affecting both absorption and desorption processes in SPME-HPLC were optimized. Static desorption in both HPLC systems showed better recoveries for the phenolic compounds. The performance of the SPME-HPLC-UV-ED method was evaluated with river water and wastewater samples. The method enabled the determination of phenolic compounds at low levels in these water samples.

Chromatography, High Pressure Liquid↗

Solid-phase microextraction coupled with high-performance liquid chromatography for the determination of phenylurea herbicides in aqueous samples.

Solid-phase microextraction coupled with high-performance liquid chromatography was successfully applied to the analysis of nine phenylurea herbicides (metoxuron, monuron, chlorotoluron, isoproturon, monolinuron, metobromuron, buturon, linuron, and chlorbromuron). Polydimethylsiloxane-divinylbenzene (PDMS-DVB, 60 microm) and Carbowax-templated resin (CW-TPR, 50 microm) fibers were selected from four commercial fibers for further study because of their better extraction efficiencies. The parameters of the desorption procedure were studied and optimized. The effects of the properties of analytes and fiber coatings, carryover, duration and temperature of absorption, pH, organic solvent and ionic strength of samples were also investigated. External calibration with an aqueous standard can be used for the analysis of environmental samples (lake water) using either PDMS-DVB or CW-TPR fibers. Good precisions (1.0-5.9%) are achieved for this method, and the detection limits are at the level of 0.5-5.1 ng/ml.

Calibration↗

Solid-phase microextraction with capillary gas-liquid chromatography and nitrogen-phosphorus selective detection for the assay of antidepressant drugs in human plasma.

Solid-phase microextraction (SPME) was tested as a sample preparation for the simultaneous assay of ten antidepressant drugs and metabolites (TADs) in human plasma. Aqueous NaOH (0.5 ml, 1 M) and chloramitriptyline (50 microliters, 40 micrograms/ml) as internal standard (I.S.) were added to a 2-ml plasma sample. This mixture was extracted with a 100-micron polydimethylsiloxane SPME fiber (Supelco) for 10 min. After washing in water and methanol (50%) and subsequent drying at room temperature, desorption of the fiber was performed in the injection port of a gas chromatograph at 260 degrees C for 1 min (HP 5890, DB-17 30 m x 0.25 mm I.D., 0.25 micron capillary; 0.7 ml/min nitrogen; nitrogen-phosphorus selective detection). The recovery was found to be very low from plasma (0.3% to 0.8%) but considerably higher from water (about 15%). Therefore, the high protein binding of antidepressants appears to be the main limiting mechanism for a better extraction. However, the analytes were well separated and the calibrations were linear between 125 ng/ml and 2000 ng/ml. The limits of quantification were about 90 ng/ml for imipramine and desipramine, 125 ng/ml for amitriptyline, trimipramine, doxepine, nortriptyline and mianserine and about 200 ng/ml for maprotiline, clomipramine and desmethylclomipramine. The recovery was improved by increasing the extraction time. The influence of the concentrations of the sum of proteins and of alpha-acid glycoprotein on the peak-area ratios ATAD/A I.S. and on absolute peak areas was studied. Peak-area ratios increased with decreasing protein concentration but were found to be independent on alpha-acid glycoprotein. A simple model for the explanation of the effect is presented. Measures for the improvement of sensitivity are discussed. As presented in this paper, which first describes SPME for the analysis of drugs in plasma, SPME with a short extraction time can be of only very limited value for therapeutic drug monitoring. Lower concentrations than the limit of quantification are usually found at therapeutic doses. The method can be useful for toxicological analysis after the accidental or suicidal intake of higher doses. However, an about 10-fold improvement of the sensitivity of the method seems to be possible.

Antidepressive Agents↗

Development of an improved heated interface for coupling solid-phase microextraction to high-performance liquid chromatography.

The aim of the study described in this report has been the development and the evaluation of a new improved interface to be operated under continuous heating, for on-line coupling solid-phase microextraction (SPME) to high-performance liquid chromatography (HPLC). Heating is desirable to increase desorption rate and decrease carryover. The results obtained have been compared with that obtained by off-line desorption and online desorption without heating. The SPME-HPLC interface described here has an inner volume of 60 microL, fixation for infinite points and a novel leak less sealing system. When the heating system was used, the area values were almost 10-fold higher than that obtained using the off-line mode. The obtained chromatograms showed an increasing of the area and height of chromatographic peaks and proved the excellent performance and reproducibility of the interface developed in this work.

Chemical Fractionation↗

Determination of fluoroquinolones in eggs using in-tube solid-phase microextraction coupled to high-performance liquid chromatography.

A simple, rapid, and sensitive method using in-tube solid-phase microextraction (in-tube SPME) based on poly(methacrylic acid-ethylene glycol dimethacrylate) (MAA-EGDMA) monolith coupled to HPLC with fluorescence and UV detection was developed for the determination of five fluoroquinolones (FQs). Ofloxacin (OFL), norfloxacin (NOR), ciprofloxacin (CIP), enrofloxacin (ENRO), and sarafloxacin (SARA) can be enriched and determined in the spiked eggs and albumins. CIP/ENRO in eggs and albumins of ENRO-treated hens were also studied using the proposed method. Only homogenization, dilution, and centrifugation were required before the sample was supplied to the in-tube microextraction, and no organic solvents were consumed in the procedures. Under the optimized extraction conditions, good extraction efficiency for the five FQs was obtained with no matrix interference in the process of extraction and the subsequent chromatographic separation. The detection limits (S/N=3) were found to be 0.1-2.6 ng g(-1) and 0.2-2.4 ng g(-1) in whole egg and egg albumin, respectively. Good linearity could be achieved over the range 2-500 ng mL(-1) for the five FQs with regression coefficients above 0.9995 in both whole egg and albumin. The reproducibility of the method was evaluated at three concentration levels, with the resulting relative standard deviations (RSDs) less than 7%. The method was successfully applied to the analysis of ENRO and its primary metabolite CIP in the eggs and albumins of ENRO-treated hens.

Albumins↗

Determination of microcystins in water using integrated solid-phase microextraction with microbore high-performance liquid chromatography-electrospray quadruple time-of-flight mass spectrometry.

The development of a technique combining solid-phase microextraction (SPME) with microbore high-performance liquid chromatography (micro-HPLC)-tandem quadrupole time-of-flight (QTOF) mass spectrometry (MS) for determination of dissolved microcystins in water is reported. Several important parameters affecting the efficiency of SPME extraction of microcystins are investigated. A microbore C18 column HPLC coupled with tandem QTOF-MS with information-dependent acquisition (IDA) is developed to effectively analyze microcystins in microliter volumes of SPME extracts. The micro-HPLC-QTOF-MS with IDA technique provides comprehensive information, including a survey chromatogram (total ion chromatogram), full scan mass spectrum, and product ion scan mass spectra at different collision energies for individual analytes, which allows for both identification and quantitation in the same run. Linear calibration curves of microcystin standard [microcystin (MC)-arginine (R)R] 1-100 microg/L and of microcystin standard [MC-leucine (L)R] 1-250 microg/L are obtained with a correlation coefficient of 0.996. The combination of SPME with HPLC-QTOF-MS and IDA offers limits of detection of 0.6 pg for MC-RR and 1.6 pg for MC-LR. Analysis of spiked lake-water samples shows a recovery of > 86% for MC-RR and > 70% for MC-LR. This technique requires small sample volumes, minimizes the use of organic solvents, and provides sensitive and information-rich analysis of unknown samples.

Chromatography, High Pressure Liquid↗

Determination of endocrine disruptors in environmental waters using poly(acrylamide-vinylpyridine) monolithic capillary for in-tube solid-phase microextraction coupled to high-performance liquid chromatography with fluorescence detection.

A method for the determination of endocrine disruptors, bisphenol A and 17alpha-ethinylestradiol, in environmental water samples was developed using in-tube solid-phase microextraction followed by liquid chromatography and fluorescence detection. A poly(acrylamide-vinylpyridine) monolithic capillary column was applied as the extraction media in view of its greater phase ratio than open-tubular capillaries and thus higher extraction efficiency. After optimizing the extraction conditions, bisphenol A and 17alpha-ethinylestradiol were extracted directly from water samples in a wide dynamic linear range of 0.5-1000 ng mL(-1), with the detection limits obtained as 0.064 and 0.12 ng mL(-1), respectively. The precision of the method was satisfactory with the intraday and interday RSD values smaller than 7.2%. Environmental water samples of different sources were successfully analyzed with the presented method and the monolithic capillary was proved to be robust and reusable in analyzing real water samples.

Benzhydryl Compounds↗

Dynamic three-phase microextraction as a sample preparation technique prior to capillary electrophoresis.

Dynamic three-phase (liquid-liquid-liquid) microextraction was developed for capillary electrophoresis. Four aromatic amines as model compounds were extracted from 4-mL aqueous samples adjusted to basic condition (donor solution) through a small volume of organic solvent impregnated in a hollow fiber, which was held by the needle of a conventional syringe, and retracted into a 5-microL acidic acceptor solution inside the syringe. A renewable organic film and aqueous sample plug were formed inside the hollow fiber with the repeated movement of the syringe plunger enabled by a programmable syringe pump. This is believed to be the first reported instance of a semiautomated dynamic liquid-liquid-liquid microextraction (LLLME) procedure. Following this microextraction, the 5-microL acceptor solution was analyzed by capillary zone electrophoresis (CE). This new technique provided approximately 140-fold enrichment in 20 min. Utilizing 4-chloroaniline as internal standard, dynamic LLLME could provide good reproducibility (<4.0%). In addition, this method allowed the direct transfer of extracted analytes to a CE system for analysis.

Journal Article↗

Disposable ionic liquid coating for headspace solid-phase microextraction of benzene, toluene, ethylbenzene, and xylenes in paints followed by gas chromatography-flame ionization detection.

Solid-phase microextraction (SPME) with a disposable ionic liquid (IL) coating was developed for headspace extraction of benzene, toluene, ethylbenzene, and xylenes (BTEX) in paints. The SPME fiber was coated with IL prior to every extraction, then the analytes were extracted and desorbed on the injection port of gas chromatography, and finally the IL coating on the fiber was washed out with solvents. The coating and washing out of IL from the fiber can be finished in a few minutes. This disposable IL-coated fiber was applied to determine BTEX in water-soluble paints with results in good agreement with that obtained by using commercially available SPME fibers. For all the four studied paints samples, the benzene contents were under the detection limits, but relatively high contents of toluene, ethylbenzene and xylenes (56-271 microg g(-1)) were detected with spiked recoveries in the range of 70-114%. Compared to the widely used commercially available SPME fibers, this proposed disposable IL-coated fiber has much lower cost per determination, comparable reproducibility (RSD < 11%), and no carryover between each determination. Considering that IL possess good extractability for various organic compounds and metals ions, and that task-specific IL can be designed and synthesized for selective extraction of target analytes, this disposable IL coating SPME might has great potential in sample preparation.

Benzene↗

Solid-phase microextraction coupled with high performance liquid chromatography using on-line diode-array and electrochemical detection for the determination of fenitrothion and its main metabolites in environmental water samples.

The aim of this study was to develop a methodology for the analysis of the insecticide fenitrothion and its two main environmental metabolites, fenitrooxon and 3-methyl-4-nitrophenol. For this purpose, a solid-phase microextraction (SPME) method coupled to high performance liquid chromatography (LC) was optimized. Two on-line detectors, diode array (DAD) and direct current amperometrical (DCAD) were used in order to determine sensitivity and selectivity. The effects of the extraction parameters, including exposure and desorption time, pH, temperature, salt concentration and desorption mode on the extraction efficiency were studied. A satisfactory reproducibility for extractions from samples at 20 ppb-level with RSD < 12.5% (n = 10) was obtained. The calibration graphs were linear in the range of 10-1000 microg l(-1) and detection limits for the target compounds were between 1.2 and 11.8 microg l(-1) depending on which detector was used. The method was applied for determining fenitrothion and both its metabolites in river waters which run through forest areas near to aerial application of the pesticide.

Chromatography, High Pressure Liquid↗

Determination of daidzein and genistein in soybean foods by automated on-line in-tube solid-phase microextraction coupled to high-performance liquid chromatography.

An automated on-line method for the determination of the isoflavones, daidzein and genistein, was developed using in-tube solid-phase microextraction coupled to high-performance liquid chromatography (in-tube SPME-HPLC). In-tube SPME is a new extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. Daidzein, genistein and their glucosides tested in this study were clearly separated within 8 min by HPLC using an XDB-C8 column with diode array detection. In order to optimize the extraction of these compounds, several in-tube SPME parameters were examined. The glucosides daidzin and genistin were analyzed as aglycones after hydrolysis because the glucosides were not concentrated by in-tube SPME. The optimum extraction conditions for daidzein and genistein were obtained with 20 draw/eject cycles of 40 microl of sample using a Supel-Q porous layer open tubular capillary column. The extracted compounds were easily desorbed from the capillary by mobile phase flow, and carryover was not observed. Using the in-tube SPME-HPLC method, the calibration curves of these compounds were linear in the range 5-200 ng/ml, with a correlation coefficient above 0.9999 (n = 18), and the detection limits (S/N = 3) were 0.4-0.5 ng/ml. This method was successfully applied to the analysis of soybean foods without interference peaks. The recoveries of aglycones and glucosides spiked into food samples were above 97%.

Automation↗

Optimization of the SPME parameters and its online coupling with HPLC for the analysis of tricyclic antidepressants in plasma samples.

Solid-phase microextraction (SPME)-liquid chromatography (LC) is used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. Extraction conditions are optimized using a 2(3) factorial design plus a central point to evaluate the influence of the time, temperature, and matrix pH. A Polydimethylsiloxane-divinylbenzene (60-mum film thickness) fiber is selected after the assessment of different types of coating. The chromatographic separation is realized using a C(18) column (150 x 4.6 mm, 5-microm particles), ammonium acetate buffer (0.05 mol/L, pH 5.50)-acetonitrile (55:45 v/v) with 0.1% of triethylamine as mobile phase and UV-vis detection at 214 nm. Among the factorial design conditions evaluated, the best results are obtained at a pH 11.0, temperature of 30 degrees C, and extraction time of 45 min. The proposed method, using a lab-made SPME-LC interface, allowed the determination of tricyclic antidepressants in in plasma at therapeutic concentration levels.

Antidepressive Agents, Tricyclic↗

Analysis of anatoxin-a in aqueous samples by solid-phase microextraction coupled to high-performance liquid chromatography with fluorescence detection and on-fiber derivatization.

A simple method for analysis of anatoxin-a in aqueous samples was developed using solid-phase microextraction (SPME) and high-performance liquid chromatography (HPLC) with fluorescence detection. Anatoxin-a was derivatized to a fluorogenic agent on the surface of the SPME fiber. In the method an SPME fiber was immersed for 30 min in the aqueous sample. The fluorogenic derivatizing reagent (4-fluoro-7-nitro-2,1,3-benzoxadiazole, 1.0 mg/ml in methanol) was dropped or sprayed onto the fiber containing extracted analytes. The fiber was then heated for 10 min in an empty vial at 70 degrees C in a waterbath to promote derivatization. The derivatives formed on the fiber were desorbed in a SPME-HPLC interface. The interface was filled with methanol-1 mM hydrochloric acid (7:3, v/v) before inserting of the fiber into the interface. For desorption, the fiber was inserted in the interface for 5 min. For anatoxin-a in an aqueous sample, the calibration curve showed linearity in the range of 50-1500 ng/ml and the limit of detection of anatoxin-a was 20 ng/ml. No interferences were found, and the time for analysis was 55 min for one sample.

Bacterial Toxins↗

Analysis of phthalate contamination in infusion solutions by automated on-line in-tube solid-phase microextraction coupled with high-performance liquid chromatography.

Contamination of infusion solutions with phthalates was analyzed, and its origin was determined. Phthalates were determined by on-line in-tube solid-phase microextraction coupled with high-performance liquid chromatography (in-tube SPME-HPLC) with UV detection. In-tube SPME is an extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. The infusion solutions were used without any pretreatment, and the phthalates in these solutions were automatically analyzed by the on-line in-tube SPME-HPLC system. The limits of detection of phthalates in the infusion solutions were 1-10 ng/mL. With a few exceptions, the recoveries of phthalates added to the infusion solutions were above 80%. Di-n-butyl phthalate (DBP) was detected at a concentration of 7-60 ng/mL in most infusion solutions in plastic containers but was not detected in those in glass bottles. On the other hand, no other phthalates were detected in infusion solutions in either plastic or glass containers. Large amounts of DBP were detected in the adhesive used to affix the paper labels to the plastic bottles and bags, but not in the plastic containers themselves. Furthermore, DBP was shown to be readily eluted from the adhesive into water and alcohol and easily pass through the plastic. These results indicated that the source of the DBP was the adhesive used to affix the paper labels, and DBP contaminated the infusion solutions by passing through the plastic. The in-tube SPME-HPLC method is simple and rapid and provides a useful tool for the screening and determination of phthalate contamination in infusion solutions.

Adhesives↗

Monitoring of five sulfonamide antibacterial residues in milk by in-tube solid-phase microextraction coupled to high-performance liquid chromatography.

A simple, rapid, and sensitive method for the quantitative monitoring of five sulfonamide antibacterial residues in milk was developed by coupling in-tube solid-phase microextraction (SPME) to high-performance liquid chromatography with an ultraviolet detector. A poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was selected as the extraction medium for this on-line technique. To obtain optimum extraction efficiency, several parameters relating to in-tube SPME were investigated. By simple extraction with ethanol, dilution with phosphate buffer solution, and centrifugation, the sample solution then could be directly injected into the device for extraction. The calculated detection limits for sulfadiazine, sulfamethazine, sulfamethoxazole, sulfamonomethoxine sodium, and sulfacetamide sodium were 2.0, 2.8, 1.7, 2.5, and 22 ng/mL, respectively. The method was linear over the range of 20-5000 ng/mL (100-5000 ng/mL for sulfacetamide sodium) with a correlation coefficient R (2) value >0.9980. Excellent method reproducibility was found by intra- and interbatch precisions, yielding the relative standard deviations of <10.0 and <9.94%, respectively. The proposed method was proved to be robust in monitoring sulfadiazine, sulfamethazine, sulfamethoxazole, sulfamonomethoxine sodium, and sulfacetamide sodium residues in milk.

Animals↗