Prospective study of photorefractive keratectomy for myopia using the VISX StarS2 excimer laser system.

PURPOSE: To evaluate the safety, efficacy, and predictability of excimer laser photorefractive keratectomy (PRK) for compound myopic astigmatism using the VISX StarS2 excimer laser system with international version 3.1 software. METHODS: We report a prospective consecutive study of myopic excimer laser PRK, performed in a multi-surgeon environment with 200 eyes of 117 patients, to correct naturally occurring compound myopic astigmatism of between -0.50 to -5.90 D manifest refractive sphere and up to -3.50 D manifest refractive astigmatism. Patients were assessed prior to surgery and at 1, 3, 6, and 12 months after treatment. RESULTS: One hundred and ninety-eight of 200 treatments (99%) were reviewed 1 year after surgery; 193 of 198 eyes (97%) achieved 20/40 or better uncorrected visual acuity and 163 of 198 eyes (82%) achieved 20/20 or better. One eye lost two lines of Snellen visual acuity assessed at 12 months but recovered acuity when assessed at 18 months. Mean spherical equivalent corneal plane power was reduced from -3.50 to +0.90 D 1 month after treatment and 0 D at 12 months (SD 0.67 D). Three eyes of three patients underwent further treatment, two with LASIK and one with PRK for residual refractive error. Refractive astigmatism of >1.00 D was reduced from a mean -1.70 to -0.70 D at 1 year after treatment. Vector magnitude was 79% of that intended and mean vector axis error (absolute) was 8.5 degrees. No eye had a severe haze response. Pelli-Robson contrast acuity was significantly reduced after treatment from a mean 1.72 D preoperatively to 1.63 D at 12 months (P<.01). CONCLUSIONS: PRK for myopia using the VISX StarS2 excimer laser system was effective in the treatment of low myopic astigmatism, although there was a significant reduction in Pelli-Robson contrast sensitivity.

Adult↗

The interaction between excimer laser energy and vascular tissue.

The effects of XeF1 excimer laser on isolated normal and atherosclerotic aorta were studied. Experiments were performed in flowing water at constant temperature, flow rate, water depth, pulse width (10 nsec), wavelength (351 nm), beam size (1 mm2) and focal length (50 cm). The number of pulses, the pulse energy, and the pulse frequency were varied, and the vascular tissue was studied histologically. The following observations were made: tissue ablation required a minimum threshold pulse energy and was nonlinearly proportional to the number of pulses and the pulse energy delivered; precise tissue ablation occurred at low pulse frequencies, but changes resembling a thermal process were seen as pulse frequency increased; calcified plaque was more photoresistant than atheroma or normal vessel; excimer laser energy was markedly attenuated by blood; and the time interval between pulses and high peak power are related to the precision of ablation by pulsed excimer laser. It is concluded that excimer laser can rapidly and precisely ablate vascular tissue by a photothermal process.

Aorta↗

Excimer laser phototherapeutic keratectomy for recurrent pterygium.

PURPOSE: To analyze the results of excimer laser phototherapeutic keratectomy (PTK) combined with simple excision in recurrent pterygium to minimize the recurrence rate and obtain a smooth corneal surface. SETTING: Veni Vidi Eye Health Centre, Istanbul, Turkey. METHODS: Combined pterygium excision and excimer laser PTK was performed in 22 eyes with recurrent pterygium (22 patients). Both spot and scan modes of the Meditec MEL 60 excimer laser were used to produce a wide ablation layer (depth 40 to 80 microns). RESULTS: During the mean follow-up of 16.5 months (range 6 to 27 months), visual acuity, refraction, slitlamp, and corneal topography examinations were recorded. Pterygium recurred in only 1 eye (4.5%). Postoperative visual acuity improved in 15 eyes (68.2%). Keratometric readings were not accurately measured preoperatively because of corneal surface irregularities but could be easily taken after the surgery. Corneal astigmatism ranged from 0 to 2.00 diopters (D) (mean 1.23 D). Three months after surgery, no haze persisted in any eye. No significant intraoperative or postoperative complication was detected. CONCLUSIONS: Excimer laser PTK appears to simplify pterygium surgery because a superficial keratectomy is sufficient to remove pterygium. The excimer laser can be used to ablate the visible residual tissues and smooth the corneal surface, resulting in good postoperative refraction and visual acuity. Consequently, this procedure seems to be effective and safe.

Adult↗

Three-dimensional organization of collagen fibrils during corneal stromal wound healing after excimer laser keratectomy.

PURPOSE: To investigate the structural changes in corneal stromal collagen fibrils after excimer laser keratectomy in relation to the degree of corneal haze. SETTING: University of Tokyo Hospital, Tokyo, Japan. METHODS: Corneal haze was quantitatively measured by analyzing the light scattering in Scheimpflug images of the corneas of white rabbits after excimer laser keratectomy. Collagen fibril structure was examined using scanning electron microscopy after chemical digestion with sodium hydroxide solution; the same specimens were examined by transmission electron microscopy after re-embedding. RESULTS: Corneal haze reached a peak 4 weeks after excimer laser keratectomy and then gradually decreased. The collagen fibrils of the normal cornea were regularly arranged parallel to the surface of the cornea, with small interfibrillar distances. After excimer laser keratectomy, the arrangement was highly disordered, with increased interfibrillar distances. These structural changes were most prominent 4 weeks after excimer laser keratectomy. CONCLUSION: The structural changes in the collagen fibrils of the corneal stroma, especially the increase in interfibrillar distances and the disordered arrangement, were associated with corneal haze after excimer laser keratectomy.

Animals↗

ArF excimer laser irradiation of human dentin.

BACKGROUND AND OBJECTIVE: The use of excimer lasers for treatment of dental hard tissues has considerable potential because the combined characteristics of low wavelength and short pulse result in limited heat diffusion and, therefore, tissue ablation without the problems of collateral damage. To date, there are relatively few published studies concerning the effects of excimer laser irradiation on dental hard tissues. Thus the present study was conducted to examine the morphological changes in tooth dentin subsequent to ArF excimer laser irradiation. STUDY DESIGN/MATERIALS AND METHODS: The morphologic changes induced in normal, nondiseased human dentin following irradiation by an ArF excimer laser at fluences ranging from 1 to 4 J/cm2 and the number of laser pulses ranging from 50 to 1,000 were evaluated by scanning electron microscopy. RESULTS: Two modes of ablation, photochemical at low fluences and thermal at high fluences, were observed. A fluence of 1 J/ cm2 when combined with 50 or 100 pulses produced a uniform ablation of the dentin surface without signs of tissue melting. At fluences > 1.5 J/cm2, the thermal mode of ablation was more efficient at removing intertubular dentin than peritubular dentin. Further, when compared to the lower fluences, the higher settings produced a rougher ablation crater surface. Additionally, the higher fluences produced surface melting with each pulse and sealing of exposed dentinal tubules after irradiation with 100-300 laser pulses. CONCLUSIONS: The photochemical and thermal mechanisms of tooth dentin ablation were identified based on significant differences in tissue morphology following laser irradiation. The rates of tissue ablation and the observed morphologic changes indicate that the ArF excimer laser could be useful for caries removal and sealing of exposed dentinal tubules.

Dentin↗

[History of excimer laser refractive surgery in Poland].

First publication about excimer laser in 1983 became the beginning of laser refractive surgery. At the beginning excimer laser was used for PRK procedure for correction of myopia. Laser refractive surgery developed rapidly in 90-ties when LASIK and LASEK procedures started to be used for any kind of refractive errors. In Poland laser refractive surgery begun to be used in 1990.

History, 20th Century↗

Early and late quantitative angiographic results of vein graft lesions treated by excimer laser with adjunctive balloon angioplasty.

BACKGROUND: Percutaneous excimer laser coronary angioplasty (PELCA) has been approved for treatment of diseased saphenous vein bypass grafts. However, detailed and complete quantitative angiographic analysis of immediate procedural and late follow-up results has not been performed. METHODS AND RESULTS: PELCA using the CVX-300 excimer laser system was performed in 125 bypass lesions (mean graft age, 96 +/- 53 months; range, 2 to 240 months) in 106 consecutive patients at eight centers. Quantitative analyses of the procedural and follow-up angiograms were done with the Cardiac Measurement System. Stand-alone PELCA was done in 21 lesions (17%). Lesions were located at the ostium (20%), body (67%), or distal anastomosis (13%). The graft reference diameter was 3.26 +/- 0.79 mm (mean +/- SD). Minimal lumen diameter increased from 1.09 +/- 0.52 mm before treatment to 1.61 +/- 0.69 mm after laser and 2.18 +/- 0.63 mm after adjunctive balloon dilation (P < .001) but had declined at follow-up to 1.40 +/- 1.17 mm. Dissections were evident in 45% of lesions after laser treatment (types A and B, 27%; types C through F, 18%), including 7% occlusions. Angiographic success (< or = 50% diameter stenosis [% DS]) was 54% after laser and 91% after adjunctive PTCA, with an overall clinical success rate of 89%. In-hospital complications were death, 0.9%; myocardial infarction (Q-wave and non-Q-wave), 4.5%; and bypass surgery, 0.9%. Independent predictors of % DS after laser were reference diameter, lesion length, and minimal lumen diameter before laser. At angiographic follow-up in 83% of eligible patients, the restenosis rate per lesion (DS > 50%) was 52%, including 23 occlusions (24%). The only independent predictor of increased % DS at follow-up was lesion symmetry. Logistic regression indicated that smaller reference diameter was an independent predictor of late occlusion. Overall 1-year mortality was 8.6%. Actuarial event-free survival (freedom from death, myocardial infarction, bypass surgery, or target vessel percutaneous transluminal coronary angioplasty) was 48.2% at 1 year. CONCLUSIONS: Excimer laser angioplasty with adjunctive balloon angioplasty can be safely and successfully performed in diseased, old saphenous vein bypass graft lesions considered at high risk for reintervention. The extent of laser ablation remains limited by the diameter and effectiveness of the catheters. Late restenosis and, in particular, total occlusion mitigate the early benefits of the procedure. Other approaches such as the routine use of additional anticoagulation (eg, warfarin) should be considered to reduce the risk of late occlusions and restenosis after laser angioplasty of bypass grafts.

Aged↗

Early and late healing responses of normal canine artery to excimer laser irradiation.

Acute in vitro histologic studies have shown that the pulsed xenon chloride excimer laser causes precise microablation without the surrounding thermal tissue injury associated with frequently used continuous-wave lasers such as the argon, carbon dioxide, and neodymium:yttrium aluminum garnet lasers. However, the in vivo healing response of artery wall to excimer laser injury is not known. Accordingly, a xenon chloride excimer laser (308 nm, 40 nsec pulse width, 39 mJ/mm2/pulse) was transmitted via a 600 micron fused silica fiber to create 420 craters of varying depths (30 to 270 micron) in 21 normal canine femoral and carotid arteries. At 2 hours, 2 days, 10 days, and 42 days after excimer laser ablation, the artery segments were perfusion fixed in situ and analyzed by light, scanning, and transmission electron microscopy. At 2 hours, craters were covered by a carpet of platelets and entrapped red blood cells. Fibrin and exposed collagen fibers were seen at the crater base. There was a sharp demarcation of the crater-artery wall interface without lateral laser tissue injury. At 2 days, adherent platelets persisted with thrombus covering the base of the craters. Early healing responses were present, consisting of polymorphonucleated leukocytes and new endothelial cells, which extended over the crater rims. At 10 days, no thrombi were seen, and healing continued with almost complete reendothelialization. Macrophages, fibroblasts, fibrin, and entrapped red blood cells were present below the reendothelialized surface. At 42 days, healing was complete with obliteration of the craters by fibrointimal ingrowth. The surface was completely covered by a smooth monolayer of axially aligned endothelial cells. There were no aneurysms or surface hyperplastic responses. These favorable healing responses in normal canine arteries suggest that pulsed lasers with high tissue absorption coefficients, such as the xenon chloride excimer laser, may be suitable energy sources for clinical laser angioplasty procedures. However, further studies in atherosclerotic animals are required before human clinical responses can be accurately predicted.

Animals↗

Filtering glaucoma surgery using an excimer laser.

PURPOSE: To evaluate the results of excimer laser trabecular ablation in the treatment of open-angle glaucoma. SETTING: Clínica de Ojos Maldonado Bas Privada, Córdoba, Argentina. METHODS: This study comprised 32 eyes that had surgery for open-angle glaucoma between May 1997 and May 2000. The surgical procedure included topical anesthesia, a conjunctival incision, a lamellar scleral flap, and ablation of Schlemm's canal and the trabeculum with a scanning or diaphragm excimer laser system until a microperforation was produced in the underlying corneotrabecular tissue. The microperforation had no effect on the treatment and was used only as a sign that the ablation was deep enough and should be stopped. Schlemm's canal was unroofed, and its inner wall and the trabeculum were partially ablated. The scleral flap and conjunctiva were sutured. No antimetabolites were used. RESULTS: The mean intraocular pressure was 28.06 mm Hg +/- 9.82 (SD) preoperatively and 13.09 +/- 2.67 mm Hg postoperatively. Complications included hyphema (n = 3), choroidal detachment (n = 5), posterior synechias (n = 1), and posterior synechias and cataract (n = 1). CONCLUSION: Excimer laser ablation appears to be an effective option for the treatment of glaucoma that may be easier to perform than other procedures for many surgeons.

Adolescent↗

Excimer laser keratoplasty. Part 1: Basic concepts.

A commercially available ophthalmic excimer laser was used with a new "open mask system" to perform noncontact and nonthermal excimer laser keratoplasty in 20 human and 40 pig cadaver eyes. Circular penetrating corneal trephinations and corneal grafts were performed with the excimer laser set at 193 nm. Light microscopy and scanning and transmission electron microscopy of the human and pig eyes demonstrated the high quality of excimer laser trephination (smooth wound margins that were approximately parallel to the optical axis of the eye), and the superior wound configuration and geometry.

Animals↗

Harvest and storage of adult human photoreceptor cells: the vibratome compared to the excimer laser.

PURPOSE: To develop a method using the vibratome and the excimer laser to harvest a sheet of human photoreceptor cells from the retinas of cadaveric donors. METHODS: Adult human photoreceptor cells were harvested as intact sheets from the retinas of cadaver eyes using a vibratome or excimer laser. The sheets were embedded in 50% gelatin (in minimum essential medium and 300 mM sucrose) and stored at 4 degrees C. The morphology, integrity, viability and sterility of the harvested photoreceptor cells was studied. RESULTS: Light and scanning electron microscopy demonstrated sheets of adult human photoreceptor cells with an outer nuclear layer and inner and outer segments with either method of harvest. The initial viability of the outer nuclear layer, harvested an average of 28.2 h after death, was > or =94.7%. Sheets stored up to 72 h after harvest maintained a viability of > or =86.5%. The sheet of cells harvested with the vibratome frequently fragmented (n = 25, 35%) during passage through the delivery cannula in contrast to the excimer laser. Harvested sheets were sterile when the gelatin powder was irradiated prior to reconstitution. CONCLUSIONS: Intact, viable adult human photoreceptor cell sheets can be isolated from the retina of a cadaver using either the vibratome or the excimer laser and stored up to 72 h at 4 degrees C. With the vibratome, there is damage to the outer segments of the photoreceptors, the sheets are fragile, and the harvest of specimens is time-consuming as only one or two specimens can be harvested from a single donor retina. These technical limitations are avoided with the excimer laser.

Cadaver↗

Excimer laser ablative treatment of microbial keratitis.

The 193-nm excimer laser was used to ablate experimental septate fungal (Fusarium) and an atypical mycobacterial (Mycobacterium fortuitum) keratitis in an animal model. The infections were allowed to proceed for 24 and 72 hours. After incubation, ablation with a 193-nm excimer laser with 5.0-mm treatment zones was performed until all suppurative areas were treated. The corneas were excised, halved, homogenized, and plated. All cultures were negative in the 24-hour group. However, in those corneas in which the infections were allowed to proceed to 72 hours, post-treatment cultures were positive for both organisms. Histopathologic examination confirmed that 24-hour infections had been eradicated and that 72-hour infections had organisms present. Three of the eight eyes in the M. fortuitum group perforated during treatment, even though the treatment depth by computer preselection was only 150 microns. Excimer laser photoablation may be a useful technique to eradicate early, localized microbial infections. However, it is apparent that advanced infections with deep stromal involvement and suppuration cannot be eradicated using this technique. Because corneas may be perforated inadvertently during treatment, excimer laser treatment of infectious keratitis should be approached with caution and used for superficial and well circumscribed lesions.

Animals↗

[The 308 nm excimer laser in dermatology].

THE EFFICACY OF THE 308 NM EXCIMER LASER in the treatment of common psoriasis has been demonstrated. THE DOSES USED have progressively decreased, hence, limiting the adverse events that appear redhibitory with high doses. THE ADAPTATION OF THE DOSES not to the patients themselves but to each of the plaques treated should reduce the number of sessions and the cumulated close necessary to obtain clinical remission. THE 308 NM EXCIMER LASER is effective and tolerance is good in the treatment of vitiligo. It should be proposed for limited vitiligo and essentially of the "UV sensitive" areas, which have shown aesthetically correct percentage of repigmentation. THE PLACE AND INTEREST of its association with other treatments, notably with topical tacrolimus, remains to be defined. Although the results obtained in the treatment of vitiligo are promising, they have to be confirmed in larger cohorts and ensure the absence of median and long term side effects. This therefore limits its use in combined treatments in the context of controlled clinical traits. THE 30 NM EXCIMER LASER IS AN EFFECTIVE AND WELL TOLERATED TREATMENT in localised and non-nodular forms of mycosis fungoid (MF). Although the number of patients treated is limited, the clinical and histological cure observed demonstrates the interest of this new technique in the treatment of MF. These results must be confirmed in a greater number of patients. THE 308 NM EXCIMER LASER is an interesting therapeutic alternative in the treatment of plaques of alopecia areata, erosive oral lichen planus, post-surgical hypopigmentation, vergetures and localised forms of atopic dermatitis. Because of the sparcity of data and in the absence of long term follow-up, it must not be proposed in first intention.

Administration, Topical↗

Smooth muscle cell proliferation and restenosis after stand alone coronary excimer laser angioplasty.

It has been shown that coronary excimer laser angioplasty can remove atherosclerotic intracoronary tissue. Stand alone coronary excimer laser angioplasty was successfully performed in a 53 year old white man with 90% stenosis of the left anterior descending coronary artery and exertional angina (Canadian Cardiovascular Society class III). The lesion was reduced to a 30% residual stenosis with use of a 1.2 mm and subsequently a 1.8 mm diameter laser catheter. Early follow-up angiography 24 h later revealed persistent patency and unchanged lesion diameter of the target vessel. The patient was free of symptoms during the 2 month follow-up period, but died suddenly while playing in a tennis tournament 63 days after the procedure. Postmortem histologic examination revealed 80% restenosis at the lesion site without plaque disruption or thrombosis. Specific staining of the histologic specimen for smooth muscle cells using alpha-actin revealed significant smooth muscle cell proliferation at the site of coronary excimer laser angioplasty. However, most of the vessel narrowing appeared to be due to underlying fibrotic plaque as a result of insufficient tissue ablation. This was probably related to the size of the currently available catheters, which are too small to create a large channel.

Angioplasty, Laser↗

Corneal lathing using the excimer laser and a computer-controlled positioning system.

PURPOSE: To present the excimer laser corneal shaping system (ELCS-S), an add-on device to the Keratom, a commercially available 193-nm excimer laser built by Schwind. METHODS: The system is designed for the preparation of donor corneas under sterile conditions using the ultraviolet laser to offer greatest possible flexibility. Lenticules for planolamellar grafting and refractive epikeratoplasty, as well as donor buttons for penetrating keratoplasty can be computer-designed by the surgeon or technician and lathed with the system. RESULTS: Using the excimer laser corneal shaping system (ELCS-S) on human donor corneas, the central surface of the epikeratoplasty lenticule exhibited only narrow, flat concentric notches corresponding to the single lathing steps. Transmission electron microscopy revealed a damage zone of less than 0.3 microm in close approximation to the treated surface. The final thickness revealed a difference of less than +/-53 microm from the intended, initially programmed value. Ultrastructural studies showed the perpendicular stromal surface of the penetrating keratoplasty buttons to be smooth with minimal protrusion of Descemet's membrane. Endothelial injury was observed in a zone averaging between 40 and 100 microm adjacent to the cutting edge only. CONCLUSION: The excimer laser corneal shaping system (ELCS-S) allows a computer-controlled, surgeon-designed, sterile preparation of lamellar and penetrating corneal grafts with the use of the excimer laser. This could offer significant advantages in comparison to presently available systems for lamellar dissection and trephination.

Computers↗

A comparative study of corneal incisions induced by diamond and steel knives and two ultraviolet radiations from an excimer laser.

This paper reviews the potential role of excimer lasers in corneal surgery. The morphology of incisions induced by two wavelengths of excimer laser radiation, 193 nm and 248 nm, are compared with the morphology of incisions produced by diamond and steel knives. Analysis suggests that ablation induced by excimer laser results from highly localised photochemical reactions and that 193 nm is the optimal wavelength for surgery. The only significant complication of laser surgery is loss of endothelial cells when incisions are within 40 micron of Descemet's membrane.

Animals↗

Corneal light scattering and visual performance in myopic individuals with spectacles, contact lenses, or excimer laser photorefractive keratectomy.

Corneal transparency and visual performance are currently receiving much attention after excimer laser surgery. To date, emphasis has been on comparison of eyes on which laser surgery has been performed to eyes with emmetropia. A more appropriate comparison should be between eyes on which laser surgery has been performed and eyes with other forms of correction for myopia. Forward-scattered light, back-scattered light, and visual acuity were investigated and data were collected from 35 myopic individuals with various types of correction for myopia (spectacles, hard and soft contact lenses, and excimer laser surgery). Forward-scattered light was measured by using a new computerized technique, back-scattered light was measured with a charge coupled device-camera system, and visual acuity was measured with a computerized system at various levels of contrast. Spectacles, hard contact lenses, and excimer laser surgery are all superior to soft contact lenses in terms of light scatter and low-contrast visual acuity and excimer laser photorefractive keratectomy produces comparable results to spectacles one year postoperatively. At low-contrast visual acuity, mean visual acuity was 2.45 minutes of arc for the spectacle wearers, 3.21 minutes of arc for the hard contact-lens wearers, and 5.04 minutes of arc for the soft contact-lens wearers. Excimer laser patients had a mean visual acuity of 9.04 minutes of arc three months postoperatively, and 2.53 minutes of arc after one year. A mean value of 2.4% contrast for forward light scatter was obtained for spectacle wearers compared with a level of 3.84% contrast for hard contact-lens wearers and 16.1% contrast for soft contact-lens wearers. The mean value for excimer laser patients was 20% contrast three months postoperatively and 2.1% contrast one year postoperatively.

Contact Lenses↗