Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Diamond”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Identification of the diamond-like B-C phase by confocal Raman spectroscopy.

The new diamond-like B-C phase was obtained from the graphite-like BC phase in a laser-heated diamond anvil cell at high temperature 2230+/-140 K and high pressure 45 GPa. Raman spectra of the new phase measured at ambient conditions revealed a peak at 1315 cm(-1), which was attributed to longitudinal-optical (LO) mode. The X-Y Raman mapping was used to investigate spatial distribution of the diamond-like phases and was shown to be a powerful tool in studying the sp(2)-to-sp(3) phase transformations occurring in the diamond cell under high temperature and high pressure.

Diamond↗

Diamond-dusted silicone cannula for epiretinal membrane separation during vitreous surgery.

PURPOSE: To report a diamond-dusted silicone cannula as a tool for membrane separation during vitreous surgery. METHODS: A diamond-dusted silicone cannula was fashioned from flexible silicone tubing with a beveled tip and coated with diamond fragments for use during vitreous surgery. RESULTS: The instrument was used successfully in seven eyes with idiopathic macular hole and was found to be particularly useful for removing residual vitreous cortex and epiretinal membranes from around the hole. It was also effective in removing "immature membranes" in three eyes with proliferative vitreoretinopathy. CONCLUSION: The diamond-dusted silicone cannula is a useful tool for removing thin epiretinal membranes and vitreous cortex that may be difficult or nearly impossible to remove safely using other techniques.

Catheterization↗

Electrochemical analysis of acetaminophen using a boron-doped diamond thin film electrode applied to flow injection system.

The electrochemistry of acetaminophen in phosphate buffer solution (pH 8) was studied at a boron-doped diamond (BDD) thin film electrode using cyclic voltammetry, hydrodynamic voltammetry, and flow injection with amperometric detection. Cyclic voltammetry was used to study the reaction as a function of concentration of analyte. Comparison experiments were performed using a polished glassy carbon (GC) electrode. Acetaminophen undergoes quasi-reversible reaction at both of these two electrodes. The BDD and GC electrodes provided well-resolved cyclic voltammograms but the voltammetric signal-to-background ratios obtained from the diamond electrode were higher than those obtained from the GC electrode. The diamond electrode provided a linear dynamic range from 0.1 to 8 mM and a detection of 10 microM (S/B approximately 3) for voltammetric measurement. The flow injection analysis results at the diamond electrode indicated a linear dynamic range from 0.5 to 50 microM and a detection limit of 10 nM (S/N approximately 4). Acetaminophen in syrup samples has also been investigated. The results obtained in the recovery study (24.68+/-0.26 mg/ml) were comparable to those labeled (24 mg/ml).

Acetaminophen↗

Diamond-tip versus blunt-tip caliper enlargement of clear corneal incisions.

PURPOSE: To assess corneal trauma after clear corneal incision (CCI) enlargement with a diamond-tip versus a blunt-tip caliper. SETTING: University of Vienna, Austria. METHODS: Human bulbi obtained from the eye bank of the University of Vienna had a 3.0 mm single-plane CCI enlarged to 5.0 mm using either a diamond-tip or a blunt-tip adjustable caliper. During the process, eye pressure was kept between 22 and 25 mm Hg by infusing balanced salt solution using an anterior chamber maintainer. Light, scanning electron, and transmission electron microscopy were performed according to standard procedures. RESULTS: Incisions enlarged with the diamond-tip caliper were well-defined and allowed good closure of the wound lips. In contrast, the blunt-tip caliper produced widened, drumstick-shaped recesses at the lateral ends of the incisions. Adjacent to these recesses, the collagen lamellae were severely dislocated and torn. CONCLUSION: Cutting the corneal tissue with diamond tips caused less tissue damage than expanding it with blunt tips. It was not possible to temporarily widen incisions using a blunt-tip caliper without significantly intensifying tissue damage.

Aged↗

Microchip capillary electrophoresis coupled with a boron-doped diamond electrode-based electrochemical detector.

The attractive behavior and advantages of a diamond electrode detector for a micromachined capillary electrophoresis (CE) system are discussed. A chemically vapor-deposited boron-doped diamond (BDD) film band (0.3 x 6.0 mm) electrode is used for end-column amperomettic detection. The favorable performance of the diamond electrode microchip detector is indicated from comparison to a commonly used thick-film carbon detector. The diamond electrode offers enhanced sensitivity, lower noise levels, and sharper peaks for several groups of important anaytes (nitroaromatic explosives, organophosphate nerve agents, phenols). The favorable signal-to-background characteristics of the BDD-based CE detector are coupled with a greatly improved resistance to surface fouling and greater isolation from high separation voltages. The enhanced stability is indicated from a RSD of 0.8% for 60 repetitive measurements of 5 ppm 2,4,6-trinitrotoluene (vs RSD of 10.8% at the thick-film carbon electrode). A highly linear response is obtained for the explosives 1,3-dinitrobenzene and 2,4-dinitrotoluene over the 200-1,400 ppb range, with detection limits of 70 and 110 ppb, respectively. Factors influencing the performance of the BDD detector are assessed and optimized. The attractive properties of BDD make it very promising material for electrochemical detection in CE microchip systems and other micromachined flow analyzers.

Air Pollutants, Occupational↗

Electrochemical oxidation of oxalic acid at highly boron-doped diamond electrodes.

Electrochemical oxidation of oxalic acid has been investigated at bare, highly boron-doped diamond electrodes. Cyclic voltammetry and flow injection analysis with amperometric detection were used to study the electrochemical reaction. Hydrogen-terminated diamonds exhibited well-defined peaks of oxalic acid oxidation in a wide pH range. A good linear response was observed for a concentration range from 50 nM to 10 microM, with an estimated detection limit of approximately 0.5 nM (S/N = 3). In contrast, oxygen-terminated diamonds showed no response for oxalic acid oxidation inside the potential window, indicating that surface termination contributed highly to the control of the oxidation reaction. An investigation with glassy carbon electrodes was conducted to confirm the surface termination effect on oxalic acid oxidation. Although a hydrogen-terminated glassy carbon electrode showed an enhancement of signal-to-background ratio in comparison with untreated glassy carbon, less stability of the current responses was observed than that at hydrogen-terminated diamond.

Boron↗

Covalently modified silicon and diamond surfaces: resistance to nonspecific protein adsorption and optimization for biosensing.

We report the direct covalent functionalization of silicon and diamond surfaces with short ethylene glycol (EG) oligomers via photochemical reaction of the hydrogen-terminated surfaces with terminal vinyl groups of the oligomers, and the use of these monolayers to control protein binding at surfaces. Photochemical modification of Si(111) and polycrystalline diamond surfaces produces EG monolayers linked via Si-C bond formation (silicon) or C-C bond formation (diamond). X-ray photoelectron spectroscopy was used to characterize the monolayer composition. Measurements using fluorescently labeled proteins show that the EG-functionalized surfaces effectively resist nonspecific adsorption of proteins. Additionally, we demonstrate the use of mixed monolayers on silicon and diamond and apply these surfaces to control specific versus nonspecific binding to optimize a model protein sensing assay.

Adsorption↗

Functional monolayers for improved resistance to protein adsorption: oligo(ethylene glycol)-modified silicon and diamond surfaces.

The interaction of proteins with semiconductors such as silicon and diamond is of great interest for applications such as electronic biosensing. We have investigated the use of covalently bound oligo(ethylene glycol), EG, monolayers on diamond and silicon to minimize nonspecific protein adsorption. Protein adsorption was monitored by fluorescence scanning as a function of the length of the ethylene glycol chain (EG3 through EG6) and the terminal functional group (methyl- versus hydroxyl-terminated EG3 monolayer). More quantitative measurements were made by eluting adsorbed avidin from the surface and measuring the intensity of fluorescence in the solution. The attachment chemistry of the tri(ethylene glycol) molecules and monolayer orientation was studied by X-ray photoelectron spectroscopy. Improvement in the selectivity of surfaces modified with EG functionality was demonstrated in two model biosensing assays. We find that high-quality EG monolayers are formed on silicon and diamond and that these EG3 monolayers are as effective as EG3 self-assembled monolayers on gold at resisting nonspecific avidin adsorption. These results show promise for use of silicon and diamond materials in many potential applications such as biosensing and medical implants.

Adsorption↗

DNA micropatterning on polycrystalline diamond via one-step direct amination.

We report a novel method of one-step direct amination on polycrystalline diamond to produce functionalized surfaces for DNA micropatterning by photolithography. Polycrystalline diamond was exposed to UV irradiation in ammonia gas to generate amine groups directly. After patterning, optical microscopy confirmed that micropatterns covered with an Au mask were regular in size and shape. The regions outside the micropatterns were passivated with fluorine termination by C3F8 plasma, and the chemical changes on the two different surfaces--the amine groups inside the patterned regions by one-step direct amination and fluorine termination outside the patterned regions--were characterized by spatially resolved X-ray photoelectron spectroscopy (XPS). The patterned areas terminated with active amine groups were then immobilized with probe DNA via a bifunctional molecule. The sequence specificity was conducted by hybridizing fluorescently labeled target DNA to both complementary and noncomplementary probe DNA attached inside the micropatterns. The fluorescence micropatterns observed by epifluorescence microscopy corresponded to those imaged by optical microscopy. DNA hybridization and denaturation experiments on a DNA-modified diamond show that the diamond surfaces reveal superior stability. The influence of a different amination time on fluorescence intensity was compared. Different terminations as passivated layers were investigated, and as a result, fluorine termination points to the greatest signal-to-noise ratio.

Adsorption↗

The nature and origin of interstellar diamond.

Microscopic diamond was recently discovered in oxidized acid residues from several carbonaceous chondrite meteorites (for example, the C delta component of the Allende meteorite). Some of the reported properties of C delta seem in conflict with those expected of diamond. Here we present high spatial resolution analytical data which may help to explain such results. The C delta diamond is an extremely fine-grained (0.5-10 nm) single-phase material, but surface and interfacial carbon atoms, which may comprise as much as 25% of the total, impart an 'amorphous' character to some spectral data. These data support the proposed high-pressure conversion of amorphous carbon and graphite into diamonds due to grain-grain collisions in the interstellar medium although a low-pressure mechanism of formation cannot be ruled out.

Carbon↗

Compatibility of the totally replaced hip. Reduction of wear by amorphous diamond coating.

Particulate wear debris in totally replaced hips causes adverse local host reactions. The extreme form of such a reaction, aggressive granulomatosis, was found to be a distinct condition and different from simple aseptic loosening. Reactive and adaptive tissues around the totally replaced hip were made of proliferation of local fibroblast like cells and activated macrophages. Methylmethacrylate and high-molecular-weight polyethylene were shown to be essentially immunologically inert implant materials, but in small particulate form functioned as cellular irritants initiating local biological reactions leading to loosening of the implants. Chromium-cobalt-molybdenum is the most popular metallic implant material; it is hard and tough, and the bearings of this metal are partially self-polishing. In total hip implants, prerequisites for longevity of the replaced hip are good biocompatibility of the materials and sufficient tribological properties of the bearings. The third key issue is that the bearing must minimize frictional shear at the prosthetic bone-implant interface to be compatible with long-term survival. Some of the approaches to meet these demands are alumina-on-alumina and metal-on-metal designs, as well as the use of highly crosslinked polyethylene for the acetabular component. In order to avoid the wear-based deleterious properties of the conventional total hip prosthesis materials or coatings, the present work included biological and tribological testing of amorphous diamond. Previous experiments had demonstrated that a high adhesion of tetrahedral amorphous carbon coatings to a substrate can be achieved by using mixing layers or interlayers. Amorphous diamond was found to be biologically inert, and simulator testing indicated excellent wear properties for conventional total hip prostheses, in which either the ball or both bearing surfaces were coated with hydrogen-free tetrahedral amorphous diamond films. Simulator testing with such total hip prostheses showed no measurable wear or detectable delamination after 15,000,000 test cycles corresponding to 15 years of clinical use. The present work clearly shows that wear is one of the basic problems with totally replaced hips. Diamond coating of the bearing surfaces appears to be an attractive solution to improve longevity of the totally replaced hip.

Arthroplasty, Replacement, Hip↗

Diamond paste based immunosensor for the determination of azidothymidine.

An amperometric immunosensor, based on diamond paste (diamond powder and paraffin oil), has been constructed for the assay of azidothymidine (AZT). The diamond paste is impregnated with anti-AZT. The immunosensor can be used reliably for the assay of azidothymidine in its pharmaceutical formulations. The potential used for azidothymidine assay was + 240 mV vs. Ag/AgCl electrode. The surface of the immunosensor can be regenerated by simply polishing, thereby obtaining fresh immunocomposite ready to be used in a new assay. The new amperometric immunosensor, based on diamond paste, gives reliable results for the assay of AZT as raw material and from its pharmaceutical formulation.

Diamond↗

X-ray studies of synthetic radiation-counting diamonds.

Synthetic diamonds with a nitrogen content less than 100 ppm may be used as radiation dosemeters in a conduction counting mode, and are especially useful in medical applications. Crystal imperfections, revealed by x-ray diffraction topography, were found to affect counting performance. The best quality diamond gave the highest photocurrent (500 nA at 50 V mm-1 and 2.75 Gy min-1). Diamonds containing dislocations had lower photocurrents but had the advantage of shorter settling times (seconds rather than minutes). Placing contacts on two opposite cube (100) faces gave a higher photocurrent than on a pair of octahedral (111) faces. Higher photocurrents were also achieved when the majority of dislocations were perpendicular rather than parallel, to the electric field. Some recommendations for selecting synthetic diamonds for dosemeters are given.

Carbon↗

Application of diamond detectors to the dosimetry of 45 and 100 kvp therapy beams: comparison with a parallel-plate ionization chamber and Monte Carlo.

Diamond detectors have become an increasingly popular dosimetric method where either high spatial resolution is required or where photon or electron spectra are likely to change with depth or field size. However, little work has been previously reported for superficial energies. This paper reports the response of a commercially available diamond detector (PTW Freiburg/IPTB Dubna) at 45 kVp (0.55 mm Al first HVL) and 100 kVp (2.3 mm Al first HVL) including dose and dose-rate linearity, percentage depth-dose and output factors as a function of applicator size. Comparisons are made with Br J. Radiol. supplement 25 data, measurements using a PTW parallel-plate chamber and Monte Carlo simulations based on spectra determined from transmission measurements in aluminium. Excellent agreement was obtained for percentage depth-dose curves between Monte Carlo and diamond after correcting for sublinearity of the dose-rate response and energy dependence of the diamond detector. However, significant differences were noted between diamond/Monte Carlo and the parallel-plate chamber, which is attributed to the perturbation caused by the polyethylene base of the chamber

Diamond↗

Development and application of CVD diamond detectors to 14 MeV neutron flux monitoring.

CVD diamond is an interesting material for radiation detection, its atomic number (Z = 6) is close to that of soft tissues (Z = 7.1) and it can also work in harsh environments. Since many years CVD diamond films have been grown at the Faculty of Engineering, Rome 'Tor Vergata' University, and in 1998 a collaboration with ENEA Fusion Division was established to develop fast neutron monitors to be used in fusion tokamak environment. In this paper the first test of a 120 microm thick polycrystalline CVD diamond detector used for monitoring 14.7 MeV neutrons emission produced with the Frascati Neutron Generator (FNG) is reported. The detector operates in air and in pulse mode. The time irradiation profiles recorded with the CVD diamond detector were compared with those recorded by the standard monitors available at FNG (SSD, fission chamber, NE-213). Good stability and capability to operate in neutron flux up to 1.5 x 10(8) n cm(-2) s(-1) was observed. The radiation hardness property was also investigated using a 460 microm thick film and these results are also reported.

Diamond↗

Improvements in CVD diamond properties for radiotherapy dosimetry.

The goal of this work was to compare the behaviour of a chemical vapour deposited (CVD) diamond sample, grown at the University of Florence using a local procedure, with that of a commercial CVD diamond. The comparison was performed exposing both systems to 25 MV photons and measuring the current response during irradiation. Properties of dosimetric interest such as stability of response, dose rate dependence and rise time were investigated. After a preliminary study, which evidenced better performances of the commercial device with respect to the local CVD diamond, the latter was irradiated with a high fluence of fast neutrons. As a result of the neutron treatment, the quality of the CVD home-made diamond has been improved to match with that of the commercial dosemeter.

Diamond↗

Dental cutting with diamond burs: heavy-handed or light-touch?

PURPOSE: The cutting efficiency of diamond dental burs using different handpiece loads was evaluated against simulated enamel, a machinable glass ceramic (Macor). MATERIALS AND METHODS: An ultra-high-speed dental handpiece was mounted in a frictionless bearing so that the pressure applied at the contact interface between the dental bur and the cutting substrate was controlled. One type of coarse- and two types of medium-grit diamond burs were studied. Handpiece loads of 44, 91.5, and 183 g were applied at the bur/Macor interface, and cutting efficiency was determined as the amount of Macor removed in ten 30-second-duration cuts that were 4 mm in length. The data were analyzed by one-way ANOVA and a post-hoc Scheffé test at an a priori alpha = 0.05. RESULTS: Cutting efficiency depended on both the diamond grit of the bur and the load applied to the handpiece. CONCLUSIONS: The pressure used by most dentists, about 100 g at the bur tip, appears to be optimal for medium-grit burs. If the pressure applied to the handpiece is markedly increased, there was no increase in cutting efficiency for medium-grit burs. In contrast, an increased handpiece pressure raises the cutting efficiency of coarse-grit burs but the effect of this enhanced rate of cutting on the pulpal tissues is uncertain. Cutting efficiency also appeared to be dependent on debris accumulation between the diamond chips.

Analysis of Variance↗

Root surface removal and resultant surface texture with diamond-coated ultrasonic inserts: an in vitro and SEM study.

BACKGROUND: A new diamond-coated ultrasonic insert has been developed for scaling and root planing, and it was evaluated in vitro for the amount of root surface removed and the roughness of the residual root surface as a result of instrumentation. METHODS: 48 extracted single-rooted human teeth were ground flat on one root surface and mounted (flat side up) in PVC rings of standard height and diameter with improved dental stone. Each tooth surface was treated with either a plain ultrasonic insert (PI), an ultrasonic insert with a fine grit diamond coating (DI) or sharp Gracey curettes (HI). The mounted teeth were attached to a stepper motor which drove the teeth in a horizontal, reciprocal motion at a constant rate. The thickness from the flattened bottom of the ring to the flattened tooth surface was measured before and after 10, 20, and 30 instrumentation strokes for each root surface with each of the experimental instruments. A number of treated teeth were randomly selected for examination with SEM and a profilometer. Statistical analysis (analysis of co-variance) was performed to compare the amounts of tooth structure removed among the 3 instruments and t-test was used to compare the roughness of the treated root surfaces. RESULTS: The mean depth of root structure removed was PI 10.7 microm, HI 15.0 microm, and DI 46.2 microm after 10 strokes; and PI 21.6 microm, HI 33.2 and DI 142.0 microm after 30 strokes, respectively. On average, 0.9 microm, 1.3 microm, and 4.7 microm of root surface was removed with each stroke of PI, HI and DI, respectively. PI and HI were not different from each other for all the stroke cycles, while DI was significantly different from PI and HI for all the stroke cycles (p<0.0001). Analysis with the profilometer showed that the smoothest surface was produced by the PI followed by the HI. The DI produced a surface that was significantly rougher than the surface produced by the PI or HI. CONCLUSION: These results suggest that diamond-coated ultrasonic instruments will effectively plane roots, and that caution should be used during periodontal root planing procedures. Additionally, the diamond-coated instruments will produce a rougher surface than the plain inserts or the hand curettes.

Analysis of Variance↗