Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Dentures”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

A 12-month study on changes in the barrier properties of denture-loaded palatal mucosa in immediate denture wearers.

The changes of barrier properties and surface cytology of the palatal mucosa during a denture-wearing period of 12 months has been studied in 18 adult subjects. Transmucosal rates of water transport and that of a 1.10 osmol sucrose solution were registered gravimetrically before denture treatment, after 3 months and after 12 months of denture wearing according to procedures described earlier. The keratinization pattern and the leukocyte migration were evaluated from scrapings taken from the palate and the fitting surface of the denture. The clinical appearance was recorded photographically. After 3 months of denture wearing only minor changes in permeability and surface cytology were observed. After 12 months a distinct grouping of the material was possible with regard to permeability reactions, as seven subjects showed no changes, five subjects demonstrated an increased osmotic activity in the palatal mucosa, and six subjects exhibited a severely decreased barrier function. The color photos revealed inflammatory reactions of the palatal mucosa in the latter group. The cytologic observations showed after 12 months a significant decrease in the proportion of anucleated cells in the inflammatory group, but only minor changes in the remaining material.

Adult↗

The effect of dentures and denture adhesives on mouth alcohol retention.

A total of 24 alcohol-free, denture-wearing subjects were tested for mouth-alcohol retention times with an Intoxilyzer 5000. The subjects were given 30 mL doses of 80 proof brandy to swish in their mouths without swallowing for 2 min prior to expectorating the dose. Subjects were tested under three conditions: 1) with dentures removed, 2) with dentures held loosely in place without an adhesive, and 3) with dentures plus an adhesive. Beyond 20 min following expectoration, mouth alcohol made no significant contribution to the apparent breath alcohol concentration (BrAC), with trace (less than or equal to 0.01 g/210 L) readings found in only two of the subjects. Denture use, both with and without the concurrent use of adhesives does not significantly affect BrAC as long as a pretest alcohol deprivation period of 20 min is observed.

Adhesives↗

A comparison of mandibular denture base extension in conventional and implant-retained dentures.

A border outline for mandibular implant-retained dentures is described. The lingual extension of the impression is greatly reduced compared with a conventional mandibular denture. Because of the implant attachment, the shortened border is more comfortable and does not compromise denture retention. Improper implant position is also discussed with respect to denture extension.

Dental Implants↗

The swing-lock denture: its use in conventional removable partial denture prosthodontics.

This article describes the uses of the swing-lock retained removable partial denture in partially dentate patients where the potential for achievable retention with a conventionally designed removable partial denture is less than adequate. The article presents two case reports detailing effective use of the swing-lock concept in removable partial denture design and it is hoped that this article will increase the awareness of practitioners to the use of this prosthesis type when planning removable partial dentures.

Aged↗

Age and denture experience as determinants in patient denture satisfaction.

Sixty-nine male patients participated in a self-evaluation survey measuring their satisfaction with maxillary and mandibular dentures. Patients generally had a high evaluation of their dentures, with the highest scores given to appearance. Age was not a significant predictor of denture success. Patients receiving their first dentures consistently had more difficulties in all categories of function, comfort, and appearance than patients with past experience with dentures.

Age Factors↗

The effect of heat- and auto-polymerized denture base polymers on clonogenicity, apoptosis, and necrosis in fibroblasts: denture base polymers induce apoptosis and necrosis.

Eluates from poly(methyl methacrylate)-based denture base polymers have recently been found to enhance death by apoptosis and necrosis in U-937 human monoblastoid cells. The present study investigated the potential of such polymers to induce apoptosis and/or necrosis and to alter clonogenicity in L929 murine fibroblasts. A fibroblast cell line was chosen because the impairment of fibroblasts subjacent to denture bases may result in a weaker or more permeable mucosa. Two aspects were addressed: the effect of direct contact with the denture base polymers and the effect of eluates extracted from the polymers. For this purpose L929 fibroblasts were seeded on disks manufactured from three heat-polymerized and four autopolymerized denture base polymers or in different concentrations of their eluates. The effects were evaluated by light, fluorescent, confocal and electron microscopy, counting of colonies, and flow cytometry. Disks and eluates of all polymers enhanced cell death by apoptosis and necrosis in L929 cells and decreased their clonogenic potential in a dose-dependent manner. Apoptosis was the main form of cell death. In general, the deleterious effects were stronger when cells were plated directly on the polymer disks than in the eluates. The autopolymerized polymers, except one, yielded higher percentages of apoptosis and necrosis than the heat-polymerized polymers. The results of the study indicated that poly(methyl methacrylate)-based denture base polymers trigger death-signals in L929 fibroblasts and open doors for possible modulation of the cell/biomaterial interaction.

Animals↗

Colour effect of denture base on denture tooth materials.

A study using a HunterLab colorimeter was conducted to determine the colour effect of denture base materials on denture tooth acrylics. The results show that denture base materials create a measurable change in the chroma of denture tooth acrylics and suggest that optimal shade selection of teeth should include a determination of the background effects of denture base materials.

Acrylic Resins↗

Assessment of denture plaque pH in subjects with and without denture stomatitis.

To evaluate the "resting" pH and induced pH changes in denture plaque, soft deposits were collected from the fitting surface of the denture, pooled and suspended in water. Plaque pH was determined with microelectrode equipment before and after mouth rinsing with a sucrose solution. A characteristic level in the "resting" pH of denture plaque was found in most of 12 subjects tested. pH values below the baseline level were recorded for more than 2 h after a rinse. The pH depressions were more pronounced in maxillary than in mandibular plaque. Further, the pH minima tended to be lower in subjects with denture stomatitis than in controls. No clear relationship could be established between the "resting" pH and the concentration of Candida hyphae in denture smears or palatal inflammation.

Aged↗

Validation of communication between elderly denture wearers and dentists: a questionnaire on satisfaction with complete dentures using semi-structured interviews.

OBJECTIVES: To validate a semi-structured interview (SSI) for communication between complete denture wearers and dentists. DESIGN: A SSI using a questionnaire with eight questions on satisfaction with complete dentures (CD): covering function, aesthetics and comfort. The first seven questions used a five-point Likert scale and the last was dichotomous. Two dentists, carefully trained in the use of the structured questionnaire, administered the SSI. SETTING: A Greek Department of Prosthetic Dentistry. SUBJECTS: A consecutive sample of 78 CD wearers took part in the study. All subjects presented with complaints from their dentures. INTERVENTION: All participants and their dentures underwent clinical examination. RESULTS: The method showed good reliability, verified by the Cronbach alpha (0.86). Both dentists used the questionnaire produced very similar results. (Wilcoxon test 61-99%). Further, the association of the answers with respect to the five-point Likert scale was very high; all gamma coefficients were statistically significant except for pain and discomfort from the upper CD (CDU). CONCLUSIONS: This method of communication between patients and dentists is reliable and can be used to give good repeatability for qualitatively assessing satisfaction with CD. It can be valuable for clinical use and for extending the study of denture quality to establish outcome measures based on the subjective criteria of satisfaction.

Aged↗

[Application of superplastic titanium alloy for denture base--Part 1. Adaptability of the titanium alloy denture base].

The adaptability of the upper complete denture base made from superplastic alloy 90Ti-6A1-4V was investigated by measuring the space between the master model and the denture base. The denture bases showed a high adaptability with the space less than 0.1 mm, whereas after curing resin for denture, it became worse especially with the heat-curing resin. In addition, the thinnest area of the denture base was observed at the middle of the plate with 38% reduction in thickness, and distortion of the base plate of 0.55mm thickness by curing resin was found to be nearly the same as that of type 304 stainless steel plate of 0.50 mm thickness.

Dental Alloys↗

[Comparative histological study of palatal mucosa in patients with and without complete dentures before and after insertion of new dentures].

The authors verified histologically in 20 no dentates patients, the influence of complete dentures on the hard palate mucosa. The patients were divided in two groups: I. Patients that never used complete dentures; II. Patients that were using complete dentures when this research was realized. New prosthesis were made for each one of the 20 patients. Immediately before they received the new prosthesis and ninety days after this, biopsies were realized. The circunferencial pieces of the hard palate mucosa were fixed in formol 10% and coloured with Hematoxylin/Eosin and Mallory's Tricomic for histomorphologic analysis and measuring of the stratum corneum of the epithelium. It was made the statistical analysis and the results showed that: 1. In normal conditions, the utilization of the full dentures produces the reduce of the thickness of the stratum corneum. This was more observed in Group I. 2. The range difference of the thickness of the stratum corneum between the first and the second biopsies in the groups I and II (4.86 microns and 2.18 microns) were not statistically significant. 3. With the use of complete dentures the stratum corneum of the epithelium showed tendence to parakeratinization.

Adult↗

Ultrastructural relationship of denture surfaces, plaque and oral mucosa in denture stomatitis.

Denture plaque has been studied by transmission electron microscopy in glycolmethacrylate-embedded specimens from six patients presenting with typical denture stomatitis. Different types of thin and thick pellicles were found applied to the denture surface. These were in contact with a denture plaque made up predominantly of loosely packed Gram- positive and Gram- negative bacteria. Rounded, rod-shaped and filamentous micro-organisms were all evident. Group of Candida albicans with normal ultrastructure were noted in some limited zones. When surrounded by bacteria, especially by bacteria in corn-cob configurations the Candida showed cytological signs of degeneration. In one case out of six a bacterial penetration of the acrylic denture base was observed, through narrow and straight channels and subsurface cavities filled with micro-organisms. Bacterial penetration was also seen in the most superficial cell layers of the palatal mucous membrane.

Aged↗

Effect of water sorption on the resistance to plastic deformation of a denture base material relined with four different denture reline materials.

PURPOSE: The effect of water sorption on the flexural strength at the proportional limit (FSp) of a denture base material relined with four different denture reline materials was studied. MATERIALS AND METHODS: Denture base specimens were relined either after 24 hours or 30 days of water immersion. The relined specimens were tested after another period of 24 hours or 30 days of water immersion. RESULTS: Relined denture specimens generally exhibited lower FSp with an increase in water immersion time and an increase in the thickness of the reline material. CONCLUSIONS: The plasticizing effect of absorbed water molecules explains the general decrease in FSp of immersed relined specimens. The absence of a significant effect that water immersion had on some relined specimens under certain immersion conditions was explained by water sorption into the denture base achieving an equilibrium after a period of water immersion, and the resistance of some reline materials to the effect of water immersion.

Analysis of Variance↗

A 5-year longitudinal study of cantilevered fixed partial dentures compared with removable partial dentures in a geriatric population.

Prosthesis function and dental conditions were observed for 5 years in 27 elderly patients treated with mandibular cantilevered fixed partial dentures (FPDs) and in 26 elderly patients treated with distal-extension removal partial dentures (RPDs). All patients were treated with a complete upper denture. The patients were assigned randomly into two treatment groups that had the same composition with regard to sex, age, and distribution of teeth. The patients were under supervised oral hygiene and prosthodontic care. Clinical examination of prostheses, masticatory system, periodontal status, and caries was carried out yearly. Oral hygiene was good, and the periodontal status was maintained in both groups. Caries was observed six times more frequently in the RPD group than in the group with fixed restorations, however. Occlusal and functional conditions deteriorated in the RPD group only. Eight of 42 fixed partial dentures (19%) failed; of these, six were recemented with composite resin. Generally the need for dental and prosthetic follow-up treatment was more pronounced in the RPD group than in the FPD group.

Aged↗

Restoration of the partially edentulous mouth--a comparison of overdentures, removable partial dentures, fixed partial dentures and implant treatment.

OBJECTIVES: Loss of posterior teeth may result in the loss of neuromuscular stability of the mandible, reduced masticatory efficiency, loss of vertical dimension of occlusion and poor aesthetics. Prosthetic rehabilitation should aim at restoring the vertical dimension and increasing the occlusal contact area in the premolar/molar region. Overdentures are particularly indicated in patients with a severe loss of periodontal attachment, uncertain periodontal prognosis and complicated functional or aesthetic conditions. Removable partial dentures are particularly indicated in Kennedy Class I cases when there is need for a simple and economic solution. Placement of a removable partial denture with occlusal overlays is a simple way to restore occlusal face height. Cross-arch cantilevered fixed partial dentures are primarily indicated for stabilization of periodontally weakened abutments. Short unilateral or bilateral bridges are a solution in patients who refuse removable appliances and who cannot afford more extensive rehabilitation with fixed prosthodontics. Rehabilitation with a fixed partial denture supported by means of osseointegrated implants is the optimal solution in Kennedy Class II cases provided that the bone conditions are appropriate. For any prosthetic treatment, a definite recall system should be established depending on the patient's degree of cooperation, caries susceptibility, periodontal status and the rate of residual ridge resorption. This is essential in order to obtain a satisfactory prognosis. In a patient with poor oral hygiene, the best solution, with regard to the prognosis of the remaining teeth, is to abstain from any prosthetic treatment. METHODS: This manuscript reviews the current literature to identify treatment options for the Kennedy Class I and II partially edentulous patient.

Bicuspid↗

Longitudinal study on torque transmitted from a denture base to abutment tooth of a distal extension removable partial denture with circumferential clasps.

Not only forces but also torque exerted on abutment teeth are important factors for planning the construction of distal extension removable partial dentures. The purpose of this study was to make longitudinal analysis of torque transmitted from denture base to a direct abutment tooth of these dentures with circumferential clasps. The results are summarized as follows: (i) Vertical Max. MT (maximal mean value of torque) was decreased and became constant after one or one and half months of the insertion of new dentures. (ii) Lateral Max. MT in one subject was changed from the lingual direction to the buccal direction while in another subject it was constant. (iii) In the vertical direction, there were no remarkable differences of Max. MT and Ave. T (average value of torque) between subjects. Max. MT was 5-10 x 10(-3) kgm-1 in the downward. Ave. T was 2-3 x 10(-3) kgm ss-1 in the downward and 0.3 x 10(-3) kgm ss-1 in the upward. (iv) In the lateral direction, there were considerable differences of Max. MT and Ave. T between subjects. Max. MT was less than 20 x 10(-3) kgm. Ave. MT was 2-8 x 10(-3) kgm ss-1.

Aged↗

Swinglock removable partial denture and biting forces in partially edentulous patients. Comparison of individual biting forces with and without swinglock removable partial denture.

Several studies have shown that swinglock removable partial dentures are effective for stability of the abutment teeth and the surrounding tissues including alveolar bone. This efficacy has been thought to be due to the dynamic structure of the swinglock attachment. Individual biting force was measured to determine the physiological efficacy of teeth splints by use of the attachment. The results showed that individual biting forces with the swinglock removable partial denture were 10-25% higher than those without the denture. Furthermore, statistical analysis showed that the individual biting forces with the swinglock removable partial denture were significantly higher. The swinglock attachment can stabilize partially edentulous dentition by splinting all residual teeth. In addition, when physical forces are applied to the abutment teeth and the artificial teeth, this attachment can deliver and distribute the stress to the other abutment teeth and alveolar mucosa. The present findings suggest that the swinglock attachment augments the ability to withstand physical forces such as those occurring during biting and mastication.

Bite Force↗

[Characteristics of the electrical values of metal denture parts in patients wearing plate dentures].

The electric characteristics were lowered or absent in 87 patients wearing removable metal-based dentures. The explanation is as follows: in patients with plastic plate dentures and permanent metal prostheses in the oral cavity the electric charges pass between the prostheses via the saliva and oral tissues; in patients with metal-based plate dentures the charges pass along the metal basis, which fact is due to high electric conductivity of metal. Therefore in patients with plastic removable dentures the electric charges have a more detrimental effect on the oral tissues.

Dental Alloys↗