Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DIALYSIS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Price of dialysis, unit staffing, and length of dialysis treatments.

We analyzed the impact of the Medicare price for outpatient maintenance dialysis on the level and composition of staffing of dialysis units, and on the length (duration) of the average hemodialysis treatment for the period 1982 to 1987. With higher prices, dialysis units employ more total staff hours per patient per week (P less than 0.01) and use a higher proportion of registered nurses (RN) compared with other staff such as technicians and licensed practical nurses (LPN). Higher Medicare prices are also associated with longer average hemodialysis treatment duration for freestanding units (P less than 0.02), but there was no statistically significant association for hospital units. The impact of the Medicare price on both staffing and average treatment duration takes into account the calendar time trend, ie, 1987 versus 1982, which has a separate impact from the price effect. For example, to avoid the complication of technology changes over calendar time, we considered the impact of the price change at one point in time. Freestanding units that had a price cut of more than +15 in 1983, reported twice the reduction in the average dialysis treatment duration (-0.38 hours) compared with -0.20 hours (P = 0.01) for units that had a cut of less than +15. An analysis of the impact of average treatment duration on patient mortality provided some evidence that shorter treatment duration in freestanding units is associated with higher mortality. This result needs further analysis. There was no statistically significant relationship between the level of staffing in the dialysis unit or the percent of staff who were RNs and 3-year patient survival. The analysis in this report was based on 1,213 and 1,058 data forms filed with Medicare by freestanding and hospital units, respectively, for 1982 and 1987. In addition, we used a Cox proportional hazards model (multivariate) for the analysis of the 3-year patient survival for 14,807 new hemodialysis patients who started dialysis in 1984.

Fees and Charges↗

Long-term outcome in continuous ambulatory peritoneal dialysis: a 10-year-survey by the Italian Cooperative Peritoneal Dialysis Study Group.

Over a 10-year period, 1,990 end-stage renal disease patients in 30 centers were treated with continuous ambulatory peritoneal dialysis by the Italian Cooperative Peritoneal Dialysis Study Group. At the start of treatment, patients had an average age of 58.4 years, with a 66% prevalence of one or more clinical risk factors for premature death. Patient survival was 51% and 33% at 4 and 8 years on continuous ambulatory peritoneal dialysis, respectively, and technique survival was 62% and 48%, respectively. Occurrences of peritonitis progressively reduced until they reached an incidence of 0.50 episodes/yr in the last 5 years (1985 to 1989). Hernias and catheter-related problems did not influence the dropout rates. These Italian Cooperative Peritoneal Dialysis Study Group results demonstrate that continuous ambulatory peritoneal dialysis is a viable dialysis technique for long-term treatment of chronic renal failure and that it is an effective alternative to hemodialysis, especially for older and high-risk patients.

Adolescent↗

Multicentric study on paired filtration dialysis as a short, highly efficient dialysis technique.

Paired filtration dialysis (two-chamber haemodiafiltration) was evaluated as a short, highly efficient renal replacement therapy in 35 uraemic subjects belonging to three different dialysis centres. The study period was 1 year. Patients were divided into two groups according to their body-weight and drinking habits. The smaller patients underwent 150-min dialysis sessions three times weekly. The larger patients underwent 3-h treatments thrice weekly. The treatment was adequate in all patients according to the KT/V criteria of adequacy. The intradialytic symptomatology was remarkably low and the treatments were well tolerated in all patients. The study confirms the reliability of paired filtration dialysis as a short dialysis technique. In some patients 150 min may be insufficient to achieve an adequate dialysis efficiency and 180 min may be required for the majority of the population.

Adult↗

Dialysis-associated arthropathy: a multicentre survey of 171 patients receiving haemodialysis for over 10 years. The Co-operative Group on Dialysis-associated Arthropathy.

In order to determine the prevalence of dialysis-associated arthropathy (DAA) and what factors favour its development, we conducted a survey in 19 centres in northeastern France, of all patients receiving haemodialysis for over 10 years (171). A diagnosis of DAA was made in 84 patients (49%) by two investigators, using as criteria single or combined presence of carpal tunnel syndrome (32%), erosions and bone cysts of the large limb joints (33%) and destructive spondylarthropathy (14%). The 84 patients with DAA were compared with the 87 dialysis patients free of these clinical or radiological abnormalities. The affected patients were significantly older at the start of dialysis than unaffected patients. The risk of developing carpal tunnel syndrome increased with the duration of dialysis. Amyloid deposits were found in carpal tunnel tissue obtained from 24 of the 39 operated patients (62%) during surgery. Destructive spondylarthropathy was significantly associated with the presence of disc calcifications and more frequent in AN 69-treated patients in whom secondary hyperparathyroidism appeared to be more severe. The use of an AN 69 membrane for at least 90% of the dialysis period (in 15 patients) was not associated with a lower prevalence of DAA. We found that after 10 years of haemodialysis DAA occurred whatever type of membrane was used and the prevalence increased with the patient's age and the duration of dialysis.

Adolescent↗

The cardiovascular burden of the dialysis patient: the impact of dialysis technology.

There is widespread recognition that the poor survival rates of dialysis patients, attributed predominantly to cardiovascular disease, need to be addressed and improved. In this paper, we relate diverse aspects of modern dialysis technology with factors that are considered to contribute towards increased mortality and morbidity in the dialysis population. Firstly, we assess the overall cardiovascular burden of the dialysis patient: it is the sum of uraemia-related risk factors (URRF), traditional risk factors and dialysis-therapy-related factors. Secondly, we describe how key components of the dialysis procedure may be directly related to the more common URRF: the dialyser and the membrane, microbiological quality of water and dialysate, treatment modality and online monitory equipment. The judicious selection and application of these components may collectively help improve patient outcomes in hemodialysis therapy.

Cardiovascular Diseases↗

Dialysis, time and death: comparisons of two consecutive decades among patients treated at the same Brazilian dialysis center.

The survival of hemodialysis patients is likely to be influenced not only by well-known risk factors like age and comorbidity, but also by changes in dialysis technology and practices accumulated along time. We compared the survival curves, dialysis routines and some risk factors of two groups of patients admitted to a Brazilian maintenance hemodialysis program during two consecutive decades: March 1977 to December 1986 (group 1, N = 162) and January 1987 to June 1997 (group 2, N = 237). The median treatment time was 22 months (range 1-198). Survival curves were constructed using the Kaplan-Meier method and compared using the log-rank method. The Cox proportional hazard regression model was used to investigate the more important variables associated with outcome. The most important changes in dialysis routine and in patient care during the total period of observation were the progressive increase in the dose of dialysis delivered, the prohibition of potassium-free dialysate, the use of bicarbonate as a buffer and the upgrading of the dialysis equipment. There were no significant differences between the survival curves of the two groups. Survival rates at 1, 5 and 10 years were 84, 53 and 29%, respectively, for group 1 and 77, 42 and 21% for group 2. Patients in group 1 were younger (45.5 +/- 15.2 vs 52.2 +/- 15.9 years, P < 0.001) and had a lower prevalence of diabetes (11.1 vs 27.4%, P < 0.001) and of cardiovascular disease (9.3 vs 20.7%, P < 0.001). According to the Cox multivariate model, only age (hazard ratio (HR) 1.04, confidence interval (CI) 1.03-1.05, P < 0.001) and diabetes (HR 2.55, CI 1.82-3.58, P < 0.001) were independent predictors of mortality for the whole group. Patients of group 2 had a lower prevalence of sudden death (19.1 vs 9.7%, P < 0.001). After adjusting for age, diabetes and other mortality risk factors, the risk of death was 17% lower in group 2, although this difference was not statistically significant. We conclude that the negative effects of advanced age and of higher frequency of comorbidity on the survival of group 2 patients were probably offset by improvements in patient care and in the quality and dose of dialysis delivered, so that the survival curves did not undergo significant changes along time.

Ambulatory Care Facilities↗

Pre-dialysis glycemic control is an independent predictor of mortality in type II diabetic patients on continuous ambulatory peritoneal dialysis.

OBJECTIVE: To evaluate the impact of pre-dialysis glycemic control on clinical outcomes for type II diabetic patients on continuous ambulatory peritoneal dialysis (CAPD). MATERIALS AND METHODS: One hundred and one type II diabetic patients receiving CAPD for at least 3 months were enrolled in a single institute. The patients were classified into two groups according to status of glycemic control. In the good glycemic control group, more than 50% of blood glucose determinations were within 3.3-11.0 mmol/L and glycosylated hemoglobin (HbA1C) levels were within 5%-10% at all times. In the poor glycemic control group, less than 50% of blood glucose determinations were within 3.3-11.0 mmol/L, or HbA1C levels were above 10% at least 6 months before peritoneal dialysis was started. In addition to glycemic control status, pre-dialysis serum albumin, cholesterol levels, residual renal function, peritoneal membrane function, and modes of glycemic control were also recorded. RESULTS: The patients with good glycemic control had significantly better survival than those with poor glycemic control (p < 0.01). There was no significant difference in pre-dialysis morbidity between two groups. No significant differences were observed in patient survival between patients with serum albumin above 30 g/L and those with serum albumin under 30 g/L; between those with cholesterol levels above or below 5.2 mmol/L; and between those with different peritoneal membrane solute transport characteristics as evaluated by a peritoneal equilibration test (PET). Furthermore, there was no significant difference in survival between patients who controlled blood sugar by diet and those who controlled it by insulin. Cardiovascular disease and infection are the major causes of death in both groups. Although good glycemic control predicts better survival, it does not change the pattern of mortality in diabetic patients maintained on CAPD. CONCLUSIONS: Glycemic control before starting dialysis is a predictor of survival for type II diabetic patients on CAPD. Patients with poor glycemic control predialysis are associated with increased morbidity and shortened survival.

Blood Glucose↗

Tidal peritoneal dialysis to achieve comfort in chronic peritoneal dialysis patients.

Patients with end-stage renal disease on chronic peritoneal dialysis (CPD) can usually tolerate continuous ambulatory peritoneal dialysis (CAPD) or continuous cycling peritoneal dialysis (CCPD) without abdominal discomfort or pain. In some patients, pain or discomfort occurs with complete drain of the peritoneal dialysis solution or upon initiation of dialysis filling when the peritoneal cavity is empty. We report on the use of tidal peritoneal dialysis (TPD) as a modality to alleviate this pain. Of 136 patients in our CPD unit, 18 (13%) were complaining of pain with complete drain or upon instillation of PD fluid. All were placed on TPD after other causes for abdominal pain were excluded. Six patients were placed on 25% TPD, and 12 patients on 50% TPD. The mean Kt/V of the patients on TPD was 2.46 +/- 0.68. With TPD, all patients had complete relief of abdominal discomfort. Patients who develop abdominal pain with complete drain or fill when the abdominal cavity is empty would benefit from TPD and be able to continue with CPD.

Female↗

Tidal peritoneal dialysis vs. continuous cyclic peritoneal dialysis: children's preference.

The purpose of this survey was to determine if the shorter dialysis time of tidal peritoneal dialysis (TPD) was valuable enough to warrant additional training time and machine assembly. The subjects included 6 children ranging in age from 5-16 years and their parents. Children and parents were taught to use an automated cycler system to provide TPD. Dialysis was limited to 8 hours and overday volumes minimized. Prescriptions were altered to prevent uremia and maintain clearances of urea and creatinine at prior continuous cyclic peritoneal dialysis (CCPD) levels. At 6 months, subjects were surveyed. Subjects felt comfortable with TPD within 6 weeks of training. They preferred the shorter dialysis time. All asked to remain on TPD, which has improved the quality of life for these children and their families by decreasing the amount of time required for dialysis.

Adolescent↗

[The impact of glucose absorbed from dialysis solution on body weight gain in peritoneal dialysis treated patients].

A proportion of peritoneal dialysis (PD) patients experience substantial body weight (BW) gain with time. It is caused by fat tissue accumulation or fluid retention. It is believed that fat tissue accumulates due to caloric contribution of glucose absorbed from dialysis solution or to the mitochondrial fat regulatory uncoupling protein (UCP) gene polymorphism. This study examined BW fluctuations in 40 patients (24 females, 16 males), treated by PD at least 36 months (initial mean age 54.50+/-9.00 years, mean BW 68.00+/-8.50 kg and mean height 164.00+/-8.50 cm), relation of the BW fluctuation and caloric contribution of glucose absorbed from dialysis solution and characteristics of the patients with BW gain. Initial BW increased after 6, 12, 24 and 36 months by 5.90+/-3.50 kg, 7.90+/-4.90 kg, 9.50+/-5.00 and 11.00+/-5.00 kg, or for 8.68, 11.62, 13.97 and 16.18% of the initial value, respectively. After the first 6 and 12 months 38 patients gained weight, 39 after 24 and all 40 patients after 36 months. There was not significant correlation between BW gain and caloric contribution of glucose absorbed from dialysis solution. Female patients had initially lower BW, but for the first 12 months period significantly increased BW more than males, and not for the other observed periods. High transporters (patients with higher transport, higher transmission of glucose from peritoneal solution into the blood, and urea and creatinine in the opposite direction, with rapid decrement of osmolality gradient between dialysate and blood that is necessary for excessive fluid elimination), had lower initial BW and, although without statistical significance, only within the first period increased BW more than low transporters. In conclusion, with time BW gain was found in all the PD dialysis patients, it was not related to caloric contribution of glucose absorbed from dialysis solution, and women and high transporters increased BW weight more than men and low transporters in the first year of treatment. The BW gain is at least in part caused by fluid retention.

Energy Intake↗

The influence of dialysis fluid composition on the blood pressure response during dialysis.

To elucidate the relative role of osmolar (sodium) and acetate shifts during dialysis, 6 patients with problems of overhydration underwent rapid ultrafiltration for 1 hr (mean weight reduction 2.0 kg), using the 1 m2 RP 6 dialyzer. Ultrafiltration was carried out at the beginning of each of 5 dialysis treatments at weekly intervals. Ultrafiltration was undertaken without dialysis (controls) and with simultaneous dialysis using acetate (40 mmoles/1) or bicarbonate (25 mmoles/1) in the dialysis fluid with dialyzate sodium concentration of 133 and 145 mmoles/1. The systolic blood pressure and mean arterial pressure which were stable with ultrafiltration only fell slightly when a high dialyzate sodium concentration was used and much further when the dialyzate sodium concentration was kept low. These changes were apparently related to the changes in plasma osmolality. Acetate had no effect on blood pressure at the higher sodium concentration, but a slight (insignificant) additive effect when used in the low-sodium dialyzate. Shifts in osmolality (sodium concentration) seem to be more important than the effect of acetate in inducing dialysis-associated hypotension.

Acetates↗

Aluminum determination in whole blood, dialysis solution, and tap water samples from Maracaibo dialysis units (Venezuela) by graphite furnace atomic absorption spectrometry.

Patients with chronic renal failure (CRF) on periodical hemodialysis may accumulate aluminum in tissues and show typical disorders such as dialysis encephalopathy, osteodystrophy, and microcytic anemia. Aluminum contamination of the water used to prepare the dialysis solution (dialysate) is one of the metal sources that may affect people under hemodialysis, especially in units in which untreated water is used. Graphite furnace atomic absorption spectrometric methods for aluminum determination in whole blood, dialysis solution, and tap water samples from CRF patients were developed, based upon the use of the same furnace temperature program. Samples were diluted 4-fold with 0.6% triton X-100 (whole blood) or with 0.01 mol/L nitric acid (dialysis solution and tap water) and analyzed by aqueous standard (blood and tap water) or matrix-matching standard (dialysis solution) calibration curves. The characteristic masses were 33.8, 11.3, and 19.5 pg Al/0.0044 A.s for whole blood, dialysate, and tap water, respectively. In the diluted solutions, the detection limits (2 sigma) for the described methods were 0.5 microgram/L Al (whole blood), 0.4 microgram/L Al (dialysate), and 0.4 microgram/L Al (tap water). The methods were applied to samples from several CRF patients under hemodialysis at Maracaibo University hospital. The data revealed extremely high aluminum levels, which corresponded to the symptoms of dialysis encephalopathy and/or osteodystrophy showed by some of them. The proposed methods are reliable and reproducible.

Aluminum↗

Tidal volume peritoneal dialysis versus intermittent peritoneal dialysis.

In a 12-week crossover study we assessed the effect of tidal volume peritoneal dialysis (TVPD) on serum chemistry, patient well-being, appetite and sleep, blood pressure, and body weight period and compared it with the effect of intermittent peritoneal dialysis (IPD) on these same parameters over a similar period. We used similar volumes of dialysis solutions per exchange and session, and the exchanges were of the same duration in each session. There were 12 patients (6 males, 6 females) with a mean age of 76 years (range 61-88 years), and mean duration of peritoneal dialysis 49 months (range 20-148 months). Five patients started with TVPD and switched to IPD after 3 months; the remaining 7 patients started with IPD and switched to TVPD for the next 3 months. No differences were seen between TVPD and IPD in any of the measured parameters: body weight, appetite, sleep, and well-being by self-assessment, number of transfusions, and complications related to peritoneal dialysis. There were two episodes of peritonitis during the TVPD period and none during the IPD period. Our data indicate that TVPD and IPD are equally effective when applied over similar durations and with similar volumes of dialysis solutions in each session. The improved results with TVPD that others have reported probably can be explained by the use of higher volumes of dialysate.

Aged↗

A comparison of peritoneal dialysis-related infections in short- and long-term peritoneal dialysis patients.

OBJECTIVE: We hypothesized that the infection rates and organisms would differ in long-term peritoneal dialysis (PD) patients versus those who died or transferred to hemodialysis during the first 4 years on PD. DESIGN: Data on PD-related infections and outcome were collected from 1979 to 1991 (prospectively since 1982). SETTING: The patients were followed at University and Veterans Administration dialysis centers. PATIENTS: All patients on continuous ambulatory peritoneal dialysis (CAPD) or continuous cycling peritoneal dialysis (CCPD) for 4 years or more (n = 43) were compared to those patients who died or transferred to hemodialysis prior to 4 years on PD (n = 213). MAIN OUTCOME MEASURES: Infection rates due to various microorganisms and reasons for transfer to hemodialysis were examined. RESULTS: Peritonitis rates were 1.2/year versus 0.8/year (p < 0.001) in patients on peritoneal dialysis less than 4 years compared to those on 4 years or more, respectively, a difference due to S. epidermidis (0.32/year vs 0.20/year, p = 0.0001) and gram-negative rods other than P. aeruginosa (0.15/year versus 0.06/year, p < 0.001). Exit-site infection rates were 1.2/year versus 0.7/y (p < 0.0001) in the patients on less than 4 years compared to those on 4 years or more, respectively, a difference in part due to S. aureus (0.45/year vs 0.3/year, p < 0.001) and other gram-positive organisms (0.28/year vs 0.10/year, p < 0.001). The rates of infections that were similar in the two groups were tunnel infections (0.2/year), P. aeruginosa infections, and S. aureus peritonitis (0.18/year vs 0.14/year, p = 0.09). S. aureus was the most common cause of exist-site and tunnel infections in both groups. Forty-two percent of the patients on PD 4 years or more subsequently transferred to hemodialysis, most often due to infections, especially S. aureus. CONCLUSIONS: Although infection rates are lower in patients on peritoneal dialysis 4 years or more, S. aureus and P. aeruginosa continue to account for a high proportion of the infections. Improvement in technique survival will require prevention of these infections.

Bacterial Infections↗

Relationships between dialysis quantification and normalized protein catabolic rate in peritoneal dialysis.

Normalized protein catabolic rates (NPCR) and urea clearances (Kt/V urea) correlate significantly in peritoneal dialysis suggesting that the adequacy of dietary protein intake and dialysis dose are interrelated. However, both of these calculated parameters are mathematical functions of the normalized urea appearance rate (GN). NPCR, GN, Kt/V urea, total creatinine clearance, residual renal clearance, and peritoneal urea and creatinine clearances were determined in 29 stable peritoneal dialysis patients with no history of recent peritonitis or other catabolic illness. Multiple linear regression analysis showed that NPCR correlated closely with both GN (r = 0.96; p < 0.0001) and Kt/V urea (r = 0.77; p < 0.0001), whereas GN also correlated with Kt/V urea (r = 0.66; p < 0.0001). Total weekly creatinine clearances rather than Kt/V urea should be utilized in peritoneal dialysis to permit independent estimations of dialysis dose and NPCR, since both Kt/V and NPCR are related closely to GN. Total weekly creatinine clearances correlated with NPCR (r = 0.59; p < 0.0002), which supports the hypothesis that dietary protein intake is dependent on the delivered dialysis dose.

Creatinine↗

Simple equations for protein catabolic rate determination from pre dialysis and post dialysis blood urea nitrogen.

Several simple equations exist for Kt/V determination from pre dialysis (Cpre) and post dialysis (Cpost) blood urea. However, comparable equations have not been available for calculation of protein catabolic rate (PCR), an essential parameter for assessing patient status. Three simple formulas for PCR determination were developed from the urea mass balance equation for an anuric patient in protein steady state receiving thrice weekly dialysis. The simplest formula, PCR = 0.0076 [Kt/V] [Cpre + Cpost] + 0.17 relates PCR (in g protein/kg/day) to Kt/V and pre and post dialysis blood urea nitrogen measurements (in mg urea nitrogen/dl) for the midweek session. When tested for 540 simulated patients spanning a range of Kt/V (0.6-1.6); PCR (0.6-1.6 g/kg/day); dialysis duration t (2-4 hrs) and interdialytic weight gain expressed as a percentage of dry body weight gained daily (0-4%), this equation yielded a maximum error of less than +/- 5%, within the accuracy generally required for clinical needs. A more accurate formula, [formula: see text] where Clm is the logarithmic mean of Cpre and Cpost, gave maximum errors in PCR estimation for the same 540 simulated patients of less than +/- 0.6%. Both formulas require a precise value of Kt/V. The equation below incorporates a very accurate simple Kt/V equation recently published by the authors, allowing PCR to be expressed in terms of Cpre, the ratio of Cpost to Cpre (R), the ratio of session ultrafiltration volume (delta BW) to urea distribution volume (V), and dialysis time (t, in min). [formula: see text] This equation was accurate to within a maximum error of +/- 1% for the simulated patient group. These equations allow simple and accurate patient PCR determination, and should be used in conjunction with a simple formula for accurate Kt/V determination to guide end-stage renal failure patient therapy.

Blood Urea Nitrogen↗

Home dialysis and dialysis treatment modalities in the VA system.

A questionnaire was sent to 50 Veterans Administration dialysis centers to inquire about treatment utilization in preparation for a Cooperative Dialysis Study. Thirty-five completed questionnaires in this survey identified a dialysis population of 2,483 patients including 452 contract patients (13.5%). The number of patients treated in-center was 1,101 (48.5%), including 239 on self-care (10.2%), and 930 patients (38.0%) were dialyzed at home. This high utilization rate of home dialysis appears in excess of three times the prevalence of home dialysis experienced overall in non-VA programs. Identification of factors responsible for the present emphasis on home programs in the VA and a corresponding analysis of non-VA programs should provide important information for the planning of future national ESRD policies.

Ambulatory Care Facilities↗

Peritoneal clearances with different dialysis regimens in children undergoing continuous cycling peritoneal dialysis.

Peritoneal clearances and dialysate protein losses occurring in paediatric patients undergoing different continuous cycling peritoneal dialysis (CCPD) regimens have not been well defined. We, therefore, evaluated 10 children aged 15.8 +/- 2.5 (SD) years who were maintained on home peritoneal dialysis for 20.5 +/- 10 months. All patients had at least 3 months of CCPD. The patients were admitted to the Clinical Research Center for 48 hours and allocated to five different dialysis protocols. In protocol I, the frequency of exchanges was 10 per 10 hours; in Protocol II it was 5 per 10 hours; and in Protocol III it was 3 per 10 hours. Protocol II D and III D had, in addition, a daytime dwell of one-half the night-time volume. A 1.5% glucose dialysate solution was used for night-time dialysis, and 4.25% glucose dialysate solution for the daytime dwell. The mean inflow dialysate volume per exchange was 36.7 +/- 5.6 ml/kg body weight and was constant in each patient for each study protocol. BUN and creatinine clearances for each protocol were calculated and dialysate protein losses were measured. The data indicate that hourly night-time dialysis (Protocol I) provides best solute clearance. A daytime dwell further enhances the total solute clearance and should be used preferably in anuric patients. Residual urine output contributes significantly to the total solute clearance. Protein losses are maximum with low-frequency exchanges and a daytime dwell. No significant differences in the serum albumin concentrations were found during the different protocols; however, the long-term effect of the protein loss on the nutritional status of the patients requires further evaluation.

Activity Cycles↗