Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Capillaries”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Titanium dioxide coated surfaces for capillary electrophoresis and capillary electrochromatography.

The potential of titanium dioxide coatings to control the electroosmotic flow and to affect the migration behavior of analytes in capillary electrophoresis and open-tubular capillary electrochromatography was evaluated. The inner wall of a fused-silica capillary was applied with a solution of a titanium peroxo complex, followed by heating at an elevated temperature. The resultant product was ascertained to be titanium dioxide in a crystalline form of anatase by the results of Fourier transform-infrared spectrometry (FT-IR), X-ray photoelectron spectroscopy, and Raman spectroscopy. The capillary thus made had anodic or cathodic electroosmotic flow, depending on the pH and composition of the background electrolyte used. The titanium dioxide surface of the capillary was readily modified by a silanizing reagent. The performance of the titanium dioxide surfaces with or without chemical modifications was examined with inorganic anions, neutral compounds and peptides.

Anions↗

Functional maturation of the capillary wall in the fetal and neonatal rat heart: permeability characteristics of developing myocardial capillaries.

The development of the functional components of the myocardial capillary wall was characterized by time-course studies of transendothelial transport of intravascularly injected probes of graded size from 16 days of gestation in the fetal rat to seven days postpartum. Despite the morphological changes occurring in the developing endothelial cells, the interaction of the probes was similar throughout the developmental period studied. The carbon particles were retained within the capillary lumina without any association with interendothelial junctions or with plasmalemmal vesicles. Carbon also was associated with coated vesicles. In contrast to carbon, ferritin was localized sequentially, over 60 sec of circulation, in plasmalemmal vesicles on the lumenal surface, in the cytoplasm, and on the ablumenal surface of the endothelial cells as well as in the interstitial space. Ferritin was located also in coated pits and vesicles and, after 90 sec of circulation, in multivesicular bodies. Within 30 sec of circulation, reaction product of myoglobin was located in plasmalemmal vesicles, coated vesicles, and transendothelial cell channels. Also within 30 sec, myoglobin partially filled the interendothelial space from the capillary lumina to the level of the tight junction. At all developmental ages studied, the interendothelial cell junctions appeared structurally tight and were impermeable to all of the probes. Once ferritin or myoglobin had reached the ablumenal space, the basal lamina did not appear to restrain the passage of the probes. Plasmalemmal vesicles are the capillary structures which transendothelially transport ferritin and myoglobin in developing myocardial capillaries.

Animals↗

Capillary filtration coefficient is independent of number of perfused capillaries in cat skeletal muscle.

The capillary filtration coefficient (CFC) is assumed to reflect both microvascular hydraulic conductivity and the number of perfused capillaries at a given moment (precapillary sphincter activity). Estimation of hydraulic conductivity in vivo with the CFC method has therefore been performed under conditions of unchanged vascular tone and metabolic influence. There are studies, however, that did not show any change in CFC after changes in vascular tone and metabolic influence, and these studies indicate that CFC may not be influenced by alteration in the number of perfused capillaries. The present study reexamined to what extent CFC in a pressure-controlled preparation depends on the vascular tone and number of perfused capillaries by analyzing how CFC is influenced by 1) vasoconstriction, 2) increase in metabolic influence by decrease in arterial blood pressure, and 3) occlusion of precapillary microvessels by arterial infusion of microspheres. CFC was calculated from the filtration rate induced by a fixed decrease in tissue pressure. Vascular tone was increased in two steps by norepinephrine (n = 7) or angiotensin II (n = 6), causing a blood flow reduction from 7.2 +/- 0.8 to at most 2.7 +/- 0.2 ml x min(-1) x 100 g(-1) (P < 0.05). The decrease in arterial pressure reduced blood flow from 4.8 +/- 0.4 to 1.40 +/- 0.1 ml x min(-1) x 100 g(-1) (n = 6). Vascular resistance increased to 990 +/- 260% of control after the infusion of microspheres (n = 6). CFC was not significantly altered from control after any of the experimental interventions. We conclude that CFC under these conditions is independent of the vascular tone and number of perfused capillaries and that variation in CFC reflects variation in microvascular hydraulic conductivity.

Angiotensin II↗

Comparison of the capillary membrane properties determining fluid exchange in single capillaries and whole organs.

We have selected whole organ and single capillary data to examine the hypothesis that a network of fibrous molecules on the surface of the endothelial cell determines the selectivity and specific hydraulic conductivity of the walls of capillary blood vessels. Fibers with a 0.3-0.6 nm radius, occupying from 3 to 5% of the pathway volume, account for the albumin reflection coefficient and the specific hydraulic conductivity of transcapillary channels in the capillaries of frog mesentery and mammalian hindlimb, heart and lung. Similar fiber dimensions account for the selectivity of fenestrated capillaries of dog gastric wall to albumin, but they predict a specific hydraulic conductivity for this organ which is smaller than the observed value. Plasma proteins are required to maintain the integrity of the size-limiting structures in the capillary wall. The data from Ringer perfused vessels conform to the hypothesis that the fibers condense into a coarser network when protein is removed from the perfusate.

Animals↗

Selective trace enrichment by immunoaffinity capillary electrochromatography on-line with capillary zone electrophoresis - laser-induced fluorescence.

Limited by the lack of a sensitive, universal detector, many capillary-based liquid-phase separation techniques might benefit from techniques that overcome modest concentration sensitivity by preconcentrating large injection volumes. The work presented employs selective solid-phase extraction by immunoaffinity capillary electrochromatography (IACEC) to enhance detection limits. A model analyte, fluorescein isothiocyanate (FITC) biotin, is electrokinetically applied to a capillary column packed with an immobilized anti-biotin-IgG support. After selective extraction by the immunoaffinity capillary, the bound analyte is eluted, migrates by capillary zone electrophoresis (CZE), and is detected by laser-induced fluorescence. The column is regenerated and reused many times. We evaluate the performance of IACEC for selective trace enrichment of analytes prior to CZE. The calibration curve for FITC-biotin bound versus application time is linear from 10 to 300 seconds. Recovery of FITC-biotin spiked into a diluted urinary metabolites solution was 89.4% versus spiked buffer, with a precision of 1.8% relative standard deviation (RSD).

Buffers↗

Alcohols and wide-bore capillaries in nonaqueous capillary electrophoresis.

The feasibility of using C1-C5 alcohols as electrolyte solutions in nonaqueous capillary zone electrophoresis was investigated. The separation of basic narcotic analgesics and acidic diuretics was modified by changing the alcohol in an electrolyte solution containing alcohol-acetonitrile-acetic acid (50:49:1, v/v) and 20 mM ammonium acetate while other experimental conditions were kept constant. The alcohols studied were methanol, ethanol, 1-propanol, 2-propanol, 1-butanol, 2-butanol, and 1-pentanol. The results indicate that even longer-chain alcohols can be used in nonaqueous capillary zone electrophoresis and, because of the lower currents they allow, they are especially advantageous in wider capillaries. Basic analytes were separated in 200 microm and 320 microm ID capillaries with 1-butanol-acetonitrile-acetic acid (50:49:1, v/v) containing 20 mM ammonium acetate as electrolyte solution. Problems related to the use of wide-bore capillaries are discussed.

Acetates↗

Fused-silica capillaries for capillary electrophoresis and gas chromatography: inner surface corrosion, within-batch differences, and influence of drawing parameters studied by atomic force microscopy.

Fused-silica capillaries for capillary electrophoresis (CE) and gas chromatography (GC) were investigated by atomic force microscopy (AFM). Differences from batch to batch and within one batch were often observed. Surface heterogeneity can be caused by bulk material, manufacturing parameters, or by aging effects. One batch of a fused-silica capillary was stored in water for three years at room temperature. The significant increase in surface roughness (measured as rms = root mean square) during this time is demonstrated. The effect of different drawing temperatures was investigated. Other drawing parameters were kept constant using one capillary batch. If the chosen drawing temperature was too low, the roughness values more than doubled. This increase in roughness did not affect the separation efficiency. However, the relative standard deviation (RSD%) of migration times and peak areas increased at the same time. Three capillary batches for gas chromatography of different inner diameters (250 microm, 320 microm, 530 microm) were also investigated. In all cases the higher rms values for surface roughness could be found at the beginning of the drawing process, although all values were close to atomic flatness.

Chromatography, Gas↗

Fast separation of oligonucleotide and triplet repeat DNA on a microfabricated capillary electrophoresis device and capillary electrophoresis.

A laser-induced fluorescence detection system coupled with a highly sensitive silicon-intensified target (SIT) camera is successfully applied to the imaging of a band for DNA fragment labeling by fluorescence dye in a microchannel, and to the visualizing of the separation process on a microfabricated chip. We demonstrated that an only 6 mm separation channel is sufficient for the separation of triplet repeat DNA fragment and DNA molecular marker within only 12 s. The separation using the microfabricated capillary electrophoresis device is confirmed to be at least 18 times faster than the same separation carried out by conventional capillary electrophoresis with 24.5 cm effective length. The use of a short capillary with 8.5 cm effective length is also efficient for fast separation of DNA; however, the microchip technology is even faster than capillary electrophoresis using a short capillary.

DNA↗

Rapid capillary coating by epoxy-poly-(dimethylacrylamide): performance in capillary zone electrophoresis of protein and polystyrene carboxylate.

A fast and simple method for the internal coating of capillaries in capillary zone electrophoresis (CZE) is that with epoxy-poly(dimethylacrylamide) (EPDMA). Duration of coating by that method is 30 min, compared with that of 24 h when using uncross-linked polyacrylamide (PA) under otherwise identical conditions. Under the conditions used for the CZE of proteins (pH 9.0, 2% polyethylene glycol), the capillary coating with EPDMA is stable for at least 50 consecutive runs as judged by the constancy of low electroosmotic flow, equalling the stability of coating achieved by PA. Protein mobilities and protein peak asymmetry (suggestive of reversible interaction with the capillary wall) are also found to be the same in EPDMA and PA coated capillaries. Differences between EPDMA and PA coating also exist: The former is unstable upon lowering the ionic strength of the buffer to 0.003, upon the addition of sodium dodecyl sulfate (SDS) to the buffer and in application to the hydrophobic analyte, polystyrene carboxylate.

Acrylic Resins↗

Capillary electrophoretic bioanalysis of therapeutically active peptides with UV and mass spectrometric detection after on-capillary preconcentration.

An earlier developed capillary electrophoresis (CE) system with an on-capillary adsorptive phase is investigated for its suitability to quantitate low concentrations of angiotensin II and gonadorelin in plasma. An off-line solid-phase extraction is used for sample preparation. The on-line preconcentration CE system allows multiple capillary volumes of sample solution to be injected, increasing the concentration sensitivity of CE with 3-4 orders of magnitude. Furthermore, possible influence of matrix salts can be ruled out by employing a rinsing step after sample application. Using short-wavelength UV detection, reproducibility and linearity in the low nanomolar range were satisfactory. The capillary could be efficiently regenerated using a programmed between-run rinsing procedure, allowing 20-30 large injections of sample extracts. Coating of the capillary improved the robustness of the method. Mass spectrometric detection via a previously reported sheathless interface increased the selectivity and sensitivity substantially. Recommendations are provided for the sample preparation process, the most critical part of the system. Further purification of the sample is required to allow the loading of larger sample volumes and to optimize the system's robustness.

Angiotensin II↗

DNA capillary electrophoresis using poly(vinyl alcohol). I. Inner capillary coating.

Two new methods of inner capillary coating with poly(vinyl alcohol) (PVAL) have been investigated and evaluated by performing DNA capillary electrophoresis (CE) using PVAL as a separation medium and by measuring the electroosmotic flow (EOF) mobility. The treatment of capillaries with a silanol-group modified PVAL (PVAL-Si) has been found to give good coating effects for improving the resolution of DNA CE and for reducing the EOF. This coating must be effectively achieved by combining the adsorptive property of PVAL chains onto silica with the reaction between the silanol groups of PVAL-Si and the silica surface. The adsorption of PVAL onto silica has been observed by using atomic force microscopy (AFM) for PVAL-Si as well as for a nonmodified PVAL as a control. The coating with PVAL that links to the capillary wall surface with more hydrolytically stable bonding, -Si-C-, has been formed by performing the Grignard reaction, followed by in-capillary polymerization of vinyl acetate (VAc) and hydrolysis. This coating has been found to be effective for improving the resolution of DNA CE and for reducing the EOF.

Adsorption↗

High-efficiency peptide analysis on monolithic multimode capillary columns: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry.

High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.

Electrophoresis, Capillary↗

Determination of different forms of human interferon-gamma in single natural killer cells by capillary electrophoresis with on-capillary immunoreaction and laser-induced fluorescence detection.

A novel method for determining different forms of human interferon-gamma (IFN-gamma) in single natural killer cells was developed by capillary electrophoresis (CE) with on-capillary immunoreaction and laser-induced fluorescence (LIF) detection. Cells were perforated with digitonin and one single cell was electrokinatically introduced into the front end of a separation capillary. The monoclonal antibody labeled with fluorescein isothiocyanate of IFN-gamma was hydrodynamically injected into the front end of the capillary around the cell introduced. After the cell was lysed by ultrasonication, the front end of the capillary was used as a microreactor to allow different forms of IFN-gamma to process the immunoreaction with their labeled antibody. Finally, the complexes of different forms of IFN-gamma with their labeled antibody were separated and detected by CE with LIF detection with a limit of detection of zeptomoles (10(-21) mol).

Cell Extracts↗

Measurement of alkaline phosphatase isoenzymes in individual mouse bone marrow fibroblast cells based on capillary electrophoresis with on-capillary enzyme-catalyzed reaction and electrochemical detection.

A novel method for the determination of alkaline phosphatase (ALP) isoenzymes in individual fibroblast cells of mouse bone marrow was developed by combining capillary electrophoresis with an on-capillary enzyme-catalyzed reaction and electrochemical detection. In this method, a single an cell, followed by 5.0 x 10(-2) mol/L Na2B4O7- 3.0 x 10(-2) mol/L NaCl (pH 9.8) as cell lysis solution, was injected into the inlet of the separation capillary by electromigration. The cell was lysed by applying a voltage of 2 kV. The ALP isoenzymes in the cell were preseparated at 20 kV for 1 min, and then allowed to react for 30 min with disodium phenyl phosphate as enzyme substrate in the running buffer. ALP converted disodium phenyl phosphate into its product, phenol, at a relatively high reaction rate without consumption, with resultant amplification of the signal on prolonged reaction time, producing an adequate amount of product for final detection. A mass detection limit as low as 3.5 x 10(-21) mol/L (corresponding to 1.5 nU) was achieved. Finally, the two zones of products generated by ALP isoenzymes were detected at the outlet of the capillary by using the end-capillary amperometric detection at a carbon fiber microdisk bundle electrode with a constant potential.

Alkaline Phosphatase↗

Control of electroosmotic flow in nonaqueous capillary electrophoresis by polymer capillary coatings.

In aqueous capillary electrophoresis the electroosmotic flow (EOF) can be strongly suppressed or eliminated by coating the capillary surface silanols either by buffer additive adsorption or chemical modification. Hydrophilic coatings, e.g., polyvinyl alcohol (PVA) proved to be most efficient for EOF control in applications like DNA analysis. In nonaqueous capillary electrophoresis (NACE), however, the EOF cannot be totally suppressed with these capillaries and coating efficiency turned out to be solvent-depending. In this paper, fused-silica capillaries with monomeric and polymeric coatings differing in hydrophobicity and chemical properties (vinyl, vinyl acetate, vinyl alcohol and acrylates with different alkyl chain length) were investigated. Besides studying the EOF characteristics with different organic solvents and water, gas chromatography (GC) measurements were carried out to probe the silanol reduction via ether retention and the surface hydrophobicity by retention of nonane. Good correlations between GC results and EOF magnitude could be found. It could be demonstrated that the polymeric coating has to be solvatized by the buffer solvent to reduce the EOF. The PVA coating was optimal for aqueous systems but not effective for some nonaqueous buffers. On the other hand, polyvinyl acetate and polyethyl acrylate as polymeric coatings proved to be optimal to reduce the EOF in NACE.

Electrophoresis, Capillary↗

Capillary electrophoresis analysis of a wide variety of seized drugs using the same capillary with dynamic coatings.

Capillary electrophoresis methodology is presented for the routine analysis of a wide variety of seized drugs using the same capillary with dynamic coatings and multiple run buffers. The types of exhibits analyzed using diode array UV detection include phenethylamines, cocaine, oxycodone, heroin, lysergic acid diethylamide (LSD), opium, hallucinogenic mushrooms, and gamma-hydroxybutyrate-gamma-butyrolactone (GHB-GBL). Both qualitative and quantitative analyses are achieved using run buffers that contain additives that provide for secondary equilibrium and/or dynamic coating of the capillary. Dynamic coating of the capillary surface is accomplished by rapid flushes of 0.1 N sodium hydroxide, water, buffer containing polycation coating reagent, and a buffer containing a polyanionic coating reagent (with or without cyclodextrin(s)) or a micelle coating reagent. Dynamic coating with a polyanionic coating reagent is used for the analysis of moderately basic seized drugs and adulterants. The use of cyclodextrin in the run buffer not only allows for chiral analysis but also greatly enhances separation selectivity for achiral solutes. A capillary dynamically coated with a micelle allows for the analysis of neutral, acidic, and weakly basic drugs (GHB, GBL and neutral, acidic, and weakly basic adulterants). Dynamic coating, which gives rise to a relatively high and robust electroosmotic flow at pH < 7, allows for rapid, precise and reproducible separations. For a wide variety of drugs, excellent linearity and migration time precision and good peak area precision (external and internal standard) is obtained. Quantitative results for synthetic mixtures are in good agreement with actual values. Screening for adulterants is greatly enhanced by the use of automated library searches.

Alkaloids↗

Study of the electroosmotic flow as a means to propel the mobile phase in capillary electrochromatography in view of further miniaturization of capillary electrochromatography systems.

In this paper, we investigate the phenomenon of electroosmosis as a means to propel a mobile phase, in particular in view of an application in microfluidic systems, which are characterized by significantly smaller volumes of the reservoirs and the separation channels compared to conventional instrumentation. In the microfluidic chip, pH changes due to water electrolysis quickly showed an effect on the electroosmotic flow (EOF), which could be counteracted by either regularly exchanging or buffering the mobile phase. Surface treatment was of no effect in regard to EOF stabilization in empty channels but may have an influence in channels filled with a charged monolith. In fused-silica capillaries the EOF was generally found to decrease from 'naked' to surface-treated to monolith-filled capillaries. The EOF tended to be higher when an organic solvent (acetonitrile) was added to the mobile phase and could be further increased by substituting the water with equal amounts of methanol. In addition, the hydrostatic pressure exerted by the EOF was investigated. In a microfluidic chip with empty (cross-)channels such an effect could be responsible for a redirection of the flow. In capillaries partially filled with a noncharged (non-EOF-generating) monolith, a linear relationship could be established between the EOF created in the empty section of the capillary (apparent mobility) and the length of the monolith (backpressure). In capillaries partially filled with a charged (EOF-producing) monolith, flow inhomogeneities must be expected as a consequence of a superimposition of hydrodynamic pressure and EOF as mobile phase driving force.

Chromatography, Micellar Electrokinetic Capillary↗

On-line sample enrichment for the determination of proteins by capillary zone electrophoresis with poly(vinyl alcohol)-coated bubble cell capillaries.

Field-amplified sample stacking (FASS) is used to separate basic proteins in a poly-(vinyl alcohol)-coated bubble cell capillary. To our knowledge, this is the first paper describing the on-column stacking of proteins (as cations) using FASS in bubble cell capillary. The bubble cell capillary is fabricated using a one-step method. Cetyltrimethylammonium chloride is added into the running buffer to reverse the EOF and, thus, to pump the water plug out during the sample stacking step. The effect of the water plug lengths and sample injection durations were investigated and optimized. The results obtained were compared with those for the normal capillary without bubble cell in terms of resolution and sensitivity enhancement. Under the optimal condition, this method can improve the sensitivity of the peak areas ranging from 5000- to 26 000-fold. The RSDs (n = 5) of the migration time and peak area are satisfactory (less than 0.6 and 12%, respectively). Application of the capillary electrophoresis method with bubble cell, FASS, and UV detection thereby leads to the determination of these proteins at concentrations ranging from 3 to 10 ng/mL, based on a signal-to-noise ratio of 3:1.

Chymotrypsinogen↗