Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Body Fluids”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

IgE regulation by nematodes: the body fluid of Ascaris contains a B-cell mitogen.

Nematode infection of human beings or laboratory animals leads to markedly increased levels of circulating IgE, most of which is not specific to worm antigens. This phenomenon is known to be interleukin-4-dependent, but little is known about the mechanism of activation of the response. In an attempt to elucidate this mechanism, we have used a reductive approach with worm products rather than infections. In a previous article we showed that injection of the body fluid of the nematode Ascaris yields a marked increase in circulating IgE. In this study we demonstrate that the body fluid contains a B-cell mitogen. Incubation with purified splenic B cells with 50 micrograms/ml body fluid yields marked proliferation of B cells, as measured by tritiated thymidine uptake. Similarly, Ascaris body fluid stimulates G0 B cells to enter the cell cycle. T cells are unaffected by the mitogen, and the response is dependent on viable accessory cells. Contamination of Ascaris body fluid or reagents by bacterial lipopolysaccharide has been ruled out as a source of artefactual data. A model is proposed, which suggests that the B-cell mitogen in Ascaris body fluid stimulates polyclonal B-cell activity and that other nematode factors either stimulate the release of interleukin-4 or act in an interleukin-4-like manner to cause class switch to IgE.

Animals↗

Serological distinction of A antigen between red blood cells and saliva in blood grouping of blood and body fluid stains.

A antigens of red blood cells and body fluids such as saliva, semen and sweat could be serologically distinguished using rabbit or guinea pig immune anti-A. As for antisera specific for red blood cell A, A+ rabbits were intravenously immunized with A group red blood cells. The resulting antisera were absorbed with O and B red cells and with A. Se saliva. The absorbed anti-A reacted with A red cells (titer 1:32) and was not inhibited with A. Se saliva. Guinea pigs were intramuscularly injected with A. Se saliva. Crude antisera contained agglutinins to human red cells which were abolished by absorption with A red cells. After absorption with O. Se saliva, the antisera were proved to have agglutinin activity with A group saliva using latex coated with A. Se saliva. A antigens from blood or body fluid stains could be distinguished by the elution method with these anti-A sera.

ABO Blood-Group System↗

A refractometry-based glucose analysis of body fluids.

In principle, refractometry appears to be a suitable method for the measurement of glucose concentrations in body fluids (such as blood and the intercellular fluid), even though the refractive index of the measured samples, as an additive property, is not specific. But, if certain conditions are fulfilled, the glucose content can be calculated using the refractive index in combination with values from a further measurement. This study describes the determination of the glucose content using refractometry in human blood serum derivates, which were selected - due to their ready availability - to be used as a model for interstitial fluid. Refractometry of body fluids requires the elimination of disturbing components from the measurement sample. First of all, a homogenous fluid (i.e. consisting of one phase) is required, so that all cells and components in suspension need to be separated out. Furthermore, certain dissolved macromolecular components which are known to disturb the measurement process must also be removed. In human serum samples which had been ultrafiltrated with a range of ultrafilters of different pore sizes, a comparative evaluation showed that only ultrafiltration through a filter with a separation limit of between 3 and 30kDa resulted in maximal reduction of the refractive index (compared to native serum), whereas ultrafilters with greater separation limits did not. The total content of osmotically active solutes (the tonicity) also exerts a clear influence. However, exemplary measurements in blood plasma fluid from one volunteer showed that the electrical conductivity is (without an additive component) directly proportional to the osmolality: physiological changes in the state of body hydration (hyperhydration and dehydration) do not lead to any considerable changes in the relation between ionised and uncharged solute particles, but instead result in a sufficiently clear dilution or concentration of the blood fluid's low molecular components. This finding allows the use of the--technically easy to measure--electrical conductivity as a measure for the tonicity of the measurement samples. Using measurements of these two parameters--refractive index and electrical conductivity--in blood serum obtained from a healthy volunteer, a two-dimensional calibration function (calibration matrix) for the assessment of the glucose content of ultrafiltrated human blood serum was constructed, and the measurement of blood glucose levels in non-diabetic (four females and four males) volunteers in comparison to a reference method was evaluated showing (as a proof of concept) a linear association. Assessment of the inaccuracy of these measurements made with the described measuring devices and methods showed a deviation from the reference values of less than 10%. An estimation of the maximum possible error showed relative deviations (maximum measurement uncertainties) of up to 20%.

Adult↗

Body fluid levels of lysergide (LSD).

Published lysergide (LSD) levels in body fluids are summarised, together with the results of 20 cases in which we determined LSD in body fluids by radioimmunoassay. The validity of methods used for LSD analysis is discussed.

Adolescent↗

Noninvasive oxygen partial pressure measurement of human body fluids in vivo using magnetic resonance imaging.

RATIONALE AND OBJECTIVES: The oxygen partial pressure (pO2) of human body fluids reflects the oxygenation status of surrounding tissues. All existing fluid pO2 measurements are invasive, requiring either microelectrode/optode placement or fluid removal. The purpose of this study is to develop a noninvasive magnetic resonance imaging method to measure the pO2 of human body fluids. MATERIALS AND METHODS: We developed an imaging paradigm that exploits the paramagnetism of molecular oxygen to create quantitative images of fluid oxygenation. A single-shot fast spin echo pulse sequence was modified to minimize artifacts from motion, fluid flow, and partial volume. Longitudinal relaxation rate (R1 = 1/T1) was measured with a time-efficient nonequilibrium saturation recovery method and correlated with pO2 measured in phantoms. RESULTS: pO2 images of human and fetal cerebrospinal fluid, bladder urine, and vitreous humor are presented and quantitative oxygenation levels are compared with prior literature estimates, where available. Significant pO2 increases are shown in cerebrospinal fluid and vitreous following 100% oxygen inhalation. Potential errors due to temperature, fluid flow, and partial volume are discussed. CONCLUSIONS: Noninvasive measurements of human body fluid pO2 in vivo are presented, which yield reasonable values based on prior literature estimates. This rapid imaging-based measurement of fluid oxygenation may provide insight into normal physiology as well as changes due to disease or during treatment.

Adult↗

[Cardiothoracic ratio and roentgenologic heart size as the indices of body fluid retention in uremics under hemodialysis].

We evaluated the cardiothoracic ratio (CTR) and the roentgenologic heart size (RHS) as the indices of body fluid retention in 31 of uremic patients under hemodialysis. The maximum changes of the roentgenologic thoracic diameter, measured monthly for one year in 31 patients, varied from 10 to 68 mm. The average differences of RHS and CTR between maximum inspiration and forced inspiration in 18 healthy people were 1 mm (RHS) and 2.5% (CTR), respectively, and the change of roentgenologic thoracic diameter was 12 mm. The error of repeated CTR measurements in a period of one year could be estimated more than 2%. In 22 patients the body weight reduction of 1 kg corresponded to a 4 mm decrease of RHS (p less than 0.005) and 1.5% of CTR (p less than 0.05), respectively. In relation to the change of body fluid balance assessed by the change of body weight, RHS showed a higher correlation than CTR. These results could be attributed that RHS was hardly influenced by the respiration, whereas CTR was surprisingly affected. It is concluded that the measurement of RHS is more useful as an index of control of body fluid balance than CTR.

Adult↗

Prepartum nutrition and solar radiation in beef cattle: I. Relationships of body fluid compartments, packed cell volume, plasma urea nitrogen, and estrogens to prenatal development.

Adaptations in body fluid pools during pregnancy were monitored in cows (n = 19) assigned to either low (LO, 70% NRC total feed intake) or high (HI, 110% NRC total feed intake) nutritional level (sudangrass hay) and to either shade (S) or no shade (NS) treatments in a 2 x 2 factorial experiment. Body water distribution (empty body water [EBW] by urea dilution; extracellular water [ECW] by thiosulfate dilution; intracellular water [ICW] by difference; plasma volume by Evans Blue dilution; interstitial water [ISW] by difference) was measured at 4-wk intervals beginning at 3 mo of pregnancy until birth and then immediately after birth. Both EBW and ICW in LO cows showed a steady decline (P < or = .05), whereas HI cows tended to maintain these body pools throughout gestation. Shading did not affect the pattern of change in EBW; however, it did produce a greater (P < or = .05) ICW in the S than in the NS cows throughout gestation. Generally, other body fluid pools (ECW, ISW, and plasma) were either not affected, or were just slightly affected, by shading or nutrition. Most of the body fluid pools (EBW, ECW, ICW, and ISW) inversely followed the seasonal changes in solar radiation. Calf birth weights were not affected by treatments but were moderately correlated to EBW (r = .49; P < or = .05) and ICW (r = .50; P < or = .05). Plasma urea nitrogen change, although not affected by nutrition, was affected (P < or = .05) by shading.(ABSTRACT TRUNCATED AT 250 WORDS)

Adaptation, Physiological↗

Redistribution of body fluids during postural manipulations.

Inter-compartmental body-fluid distribution is contingent upon posture, exercise state and environmental temperature. This investigation aimed at quantifying the distribution of intra- and extravascular fluid volumes during postural manipulations. Fluid shifts were measured in eight males utilizing a simultaneous, radionuclide dilution technique, in which radioiodinated serum fibrinogen, radiochromated erythrocytes, radiobromine and tritiated water were used to measure plasma, red cell, extracellular and total body water volumes. Subjects were exposed to three postural changes [seated (control), supine and standing] for 30 min at an air temperature of 22.0 degrees C, with each posture separated by 30 min seated rest. Total body water content remained stable throughout postural changes (P = 0.842). Relative to seated volumes, BV increased by 89 mL when supine, and decreased by 406 mL while standing (P = 0.003), with such shifts being primarily a result of plasma movement (P = 0.011). Red cell volume changes were not significant. Vascular fluid lost during standing was filtered into the interstitial compartment (P = 0.014), with the extracellular and intracellular volumes remaining unaffected. (P = 0.271 and P = 0.800, respectively). These observations confirmed the influence of posture on inter-compartmental body-fluid distribution. The intravascular fluid loss when standing was caused by the filtration of plasma into the interstitium, while, during supine rest, intravascular volume increased, reflecting fluid flux from the interstitium to the circulation.

Adult↗

Body fluid compartments in humans during acute high-altitude exposure.

Body fluid compartments were studied in a group of sea level residents at sea level and during 12 d of acute exposure to an altitude to 3,500 m. Measurements of total body water and extracellular water were done on the third and 12th days of exposure, while plasma volume was measured on 12th day only. The intracellular water, blood volume, and red cell mass were computed from the above parameters. Total body water and extracellular water decreased progressively, the decrease being 4.7% (p less than 0.001) and 6.0% (p less than 0.05) respectively on the 12th day. Plasma volume and blood volume decreased significantly with a slight increase in red cell mass. Intracellular water, computed from total body water and extracellular water, decreased by 4.3% on 12th day. This study suggested hypohydration on acute altitude exposures.

Adult↗

Enzymic analysis for rapid detection of microbial infection in human body fluids: an overview.

One possible means of rapidly detecting microorganisms in patients with suspected infectious diseases is the direct measurement of microbial enzymes in body fluids. This technique is based on the fact that bacterial, fungal, and viral organisms possess enzymes that are not produced by mammalian cells and are thus not found in uninfected human body fluids. Detection of one of these microbial enzymes in blood, cerebrospinal fluid, or other body fluids would thus be indicative of microbial infection. Potentially useful enzymes for this purpose include bacterial beta-lactamases, fungal adenine deaminases, and viral thymidine kinases. In addition, glycosidases such as neuraminidases and galactosidases can be used as markers for microbial infection, provided that the enzymic activity can be appropriately identified as being of microbial origin. The direct measurement of microbial enzymes offers great potential for the rapid diagnosis of infectious diseases.

Bacteria↗

The impact of educational interventions on primary health care workers' knowledge of occupational exposure to blood or body fluids.

AIM: To assess the impact of educational interventions on primary health care workers' knowledge of management of occupational exposure to blood or body fluids. METHODS: Cluster-randomized trial of educational interventions in two National Health Service board areas in Scotland. Medical and dental practices were randomized to four groups; Group A, a control group of practices where staff received no intervention, Group B practices where staff received a flow chart regarding the management of blood and body fluid exposures, Group C received an e-mail alert containing the flow chart and Group D practices received an oral presentation of information in the flow chart. Staff knowledge was assessed on one occasion, following the educational intervention, using an anonymous postal questionnaire. RESULTS: Two hundred and fifteen medical and dental practices were approached and 114 practices participated (response rate 53%). A total of 1120 individual questionnaires were returned. Face to face training was the most effective intervention with four of five outcome measures showing better than expected knowledge. Seventy-seven percent of staff identified themselves as at risk of exposure to blood and body fluids. Twenty-one percent of staff believed they were not at risk of exposure to blood-borne viruses although potentially exposed and 16% of exposed staff had not been immunized against hepatitis B. Of the 856 'at risk' staff, 48% had not received training regarding blood-borne viruses. CONCLUSIONS: We found greater knowledge regarding management of exposures to blood and body fluids following face to face training than other educational interventions. There is a need for education of at risk primary health care workers.

Allied Health Personnel↗

Apatite formed on the surface of plasma-sprayed wollastonite coating immersed in simulated body fluid.

Wollastonite coatings on titanium alloys substrates were prepared by plasma spraying and incubated in simulated body fluids for different periods to investigate the nucleation and growth of apatite on their surface. Surface structural changes of the specimens were analyzed by XRD and IR technologies. SEM and EDS were used to observe surface morphologies and determine the composition of wollastonite coatings before and after immersion in simulated body fluid. The changes in the concentrations of calcium, silicon and phosphorus in the simulated body fluids due to the immersion of the specimens were measured by inductively coupled plasma atomic emission spectroscopy. The results obtained showed that hydroxycarbonate apatite can be formed on the surface of the coating soaked in SBF for 1 day. With longer immersion periods, the coating surface was covered by hydroxycarbonate apatite, which indicated that the wollastonite coating possesses good bioactivity.

Alloys↗

Comparison of the antimicrobial adhesion potential of human body fluid glycoconjugates using fucose-binding lectin (PA-IIL) of Pseudomonas aeruginosa and Ulex europaeus lectin (UEA-I).

Pseudomonas aeruginosa produces a fucose-binding lectin (PA-IIL) which strongly binds to human cells. This lectin was shown to be highly sensitive to inhibition by fucose-bearing human milk glycoproteins. Since the glycans of these glycoproteins mimic human cell receptors, they may function as decoys in blocking lectin-dependent pathogen adhesion to the host cells. Human saliva and seminal fluid also contain such compounds, and body fluids of individuals who are "secretors" express additional fucosylated (alpha 1,2) residues. The latter are selectively detected by Ulex europaeus lectin UEA-I. The aim of the present research was to compare the PA-IIL and UEA-I interactions with human salivas and seminal fluids of "secretors" and "nonsecretors" with those obtained with the respective milks. Using hemagglutination inhibition and Western blot analyses, we showed that PA-IIL interactions with the saliva and seminal fluid glycoproteins were somewhat weaker than those obtained with the milk and that "nonsecretor" body fluids were not less efficient than those of "secretors" in PA-IIL blocking. UEA-I, which interacted only with the "secretors" glycoproteins, was most sensitive to those of the seminal fluids.

Bacterial Adhesion↗

Use of bioelectrical impedance analysis to estimate body fluid compartments after acute variations of the body hydration level.

Physiological measurements including body mass, plasma osmolality, natremia, plasma volume measured by Evans Blue dilution, and total body water (TBW) and extracellular water (ECW) volumes estimated by bioelectrical impedance analysis (BIA) were recorded in eight healthy young Caucasian subjects before and after acute variations of their body hydration state on four separate occasions: 1) euhydration or control trial (C); 2) heat-induced dehydration of 2.8% body mass (D); 3) exercise-induced dehydration of 2.8% body mass (E); and 4) glycerol-hyperhydration (H). Heart rate, rectal and mean skin temperatures were also recorded throughout the experiment. The main result of the study is that BIA only half predicted the body water loss after exercise, although conditions were standardized (electrode placement, side of the body, limb position, posture, and ambient temperature). Differences in body temperatures cannot explain such an unexpected result, nor did the study of plasma osmolality and sodium concentration. If BIA appears to adequately predict changes in TBW after heat-induced dehydration and glycerol hyperhydration, further studies including measures of TBW and ECW by dilution tracer methods would be necessary to establish the validity of using the BIA method to measure such changes and to interpret ECW variations.

Adult↗

Human body fluid proteome analysis.

The focus of this article is to review the recent advances in proteome analysis of human body fluids, including plasma/serum, urine, cerebrospinal fluid, saliva, bronchoalveolar lavage fluid, synovial fluid, nipple aspirate fluid, tear fluid, and amniotic fluid, as well as its applications to human disease biomarker discovery. We aim to summarize the proteomics technologies currently used for global identification and quantification of body fluid proteins, and elaborate the putative biomarkers discovered for a variety of human diseases through human body fluid proteome (HBFP) analysis. Some critical concerns and perspectives in this emerging field are also discussed. With the advances made in proteomics technologies, the impact of HBFP analysis in the search for clinically relevant disease biomarkers would be realized in the future.

Acute-Phase Proteins↗

Body fluid compartments in hypertension.

BACKGROUND AND OBJECTIVES: There is a correlation between the fluid and ionic homeostasis and blood pressure but it is not known if these body fluid changes represent the cause or rather the effect of the blood pressure rise. We have estimated the compartmental distribution of body fluids by means of the Bioimpedance Spectroscopy (BIS) analysis in a hypertensive cohort compared to control subjects. MATERIAL AND METHODS: We have enrolled 28 hypertensive patients (14 females, 14 males, mean age 47 +/- 5) and a sex- and age-matched control group of 37 healthy subjects (17 females and 20 males, mean age 45 +/- 8). They underwent anthropometric measurements, then extracellular (ECW) and intracellular water (ICW) were assessed using BIS. RESULTS: Both mean weight and BMI of hypertensive patients resulted significantly higher than of the control group (p < 0.05). We found higher ICW values in hypertensive compared to normotensive subjects. This difference was proportional to the difference of mean blood pressure values, reaching significance only as regards the stage II hypertensive subgroup (p < 0.03). DISCUSSION: Our data confirm that the blood pressure increases are associated to TBW, and caused mainly by ICW increases. The BIS, a simple, reliable, non invasive and cost effective methodical approach, estimating the distribution of body fluids, offers new possibility of the management of the hypertensive disease, to establish a more appropriate antihypertensive treatment. Moreover, the BIS, estimating the volume restoration of the different body compartments, may be helpful in evaluating the effectiveness of the pharmacological treatment.

Anthropometry↗