Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Angioscopes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Angioscopic observation during carotid angioplasty with stent placement.

This clinical report is the first to describe angioscopy during carotid angioplasty with stent placement. The average observation time was 3 minutes 43 seconds in 18 cases. The view was clear in 67% of cases. Lesions in the endothelium, rupture of the fibrous cap, clots, debris detaching from plaque, and stent struts were observed. No symptomatic ischemic complications occurred. Diffusion-weighted MR imaging after angioscopy showed asymptomatic ischemic lesions in 47% of cases.

Aged↗

[Percutaneous angioscopy. Report of initial experiences with PTA and local lysis under angioscopic conditions].

In dogs and 11 patients a new endoscopic method for arteries has been developed. The approach is transfemoral, and endoscopy is combined with angiography, percutaneous transluminal angioplasty (PTA), and local lysis. An ultrathin endoscope with a diameter of 2.4 mm is used, which also provides a working channel with a diameter of 0.4 mm. Guide wires, contrast media, and drugs for local lysis can be inserted through this channel. Under fluoroscopic control, the endoscope is placed in the region of interest, followed by a special method for decreasing blood flow. Endoscopy is documented by video or by a high-speed camera. No complications have occurred. In all patients, it was possible to demonstrate the results of dilatation, recanalization, or local lysis before and after the interventional procedure.

Angioplasty, Balloon↗

[Simultaneous fluo-angioscope. Image superposition for macular photocoagulation].

A new, compact optical instrument developed in clinical work is presented and its optical properties are discussed: it allows simultaneous viewing of a patient's fundus and its fluorescein angiography. Both stereo and mono angiography can be superimposed in the slit lamp in a 1-to-1 juxtaposition of fundus topography and angiogram. In this way very precise transfer of angiographical data is possible. Safety during laser coagulation is increased, and the size of iatrogenic scotomas is thus reduced. The instrument is described, and image superimposition illustrated with clinical examples.

Fluorescein Angiography↗

[Angioscopic evaluation of the immediate result of coronary angioplasty in relation to balloon inflation time].

The aim of this study was to assess the effects of coronary angioplasty on the intima with respect to the duration of balloon inflation by percutaneous angioplasty. Twenty-seven patients were randomized according to the total duration of balloon inflation: Group I "standard" duration (total duration < or = 3 min, N = 13) and Group II: prolonged duration (total duration > or = 12 min, N = 14); the type and distribution of the lesions were comparable in the two groups. The results of angioplasty were evaluated immediately after dilatation by angiography and angioscopy. Angioscopy was performed without failure or complications with perfect definition of the images in all cases. Angioscopy showed 1) intimal tears, 2) thrombi, 3) longitudinal dissections. A classification in three grades was used taking the apparent gravity of the lesions into consideration. The mean duration of balloon inflation in Group I was 205 +/- 45 s and 958 +/- 129 s in Group II. The residual stenosis was 36 +/- 8% in Group I and 26 +/- 10% in Group II (p < 0.05). Angioscopy showed the frequency of intimal tears to be twice greater in Group I (9 cases) than in Group II (4 cases) (p = 0.05). Intravascular thrombi were observed in 13 cases, 6 in Group I and 7 in Group II. One case of longitudinal dissection was observed in each group: only one of these two cases was detected at angiography. The authors conclude that repeated and prolonged balloon inflations improve the immediate results of angioplasty with less residual stenosis at angiography and a lower incidence of intimal tears at angioscopy.

Aged↗

Relationship between coronary angioscopic and intravascular ultrasound imaging and restenosis.

In order to investigate the relationship between restenosis and the morphology detected by coronary angioscopy (CASC) and introvascular ultrasound imaging (IVUS), 17 patients were detected by CASC and IVUS immediately and 3 months after percutaneous transluminal coronary angioscopy (PTCA). The results showed that the dilation index by IVUS (DIu) was significantly lower in restenosis patients than in non-restenosis patients (0.42 +/- 0.08 versus 0.78 +/- 0.16, P < 0.01) and that the elastic recoil (ER) was higher in restenosis patients than in non-restenosis patients (4.51 +/- 1.42 mm2 versus 1.63 +/- 1.20 mm2, P < 0.01), and that the elastic recoil rate (ERR) was also higher in restenosis patients than in non-restenosis patients (57.3 +/- 8.07% versus 21.80 +/- 16.84% P < 0.01), and that coronary dissection, atheromatous plaque and calcification as well as the colour of inner coronary artery had no relation with chronic restenosis. In conclusion, the elastic recoil is one of the important factors of chronic restenosis after PTCA.

Aged↗