Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Separation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89Linked to original sources

Separation and detection of phosphorylated and nonphosphorylated peptides in liquid chromatography-mass spectrometry using monolithic columns and acidic or alkaline mobile phases.

Efficient chromatographic separation is a prerequisite for the sensitive analysis of complex peptide mixtures using liquid chromatography-mass spectrometry. This is especially true for the analysis of mixtures of unmodified and posttranslationally modified peptides, for example, phosphorylated peptides in the presence of their unmodified analogues. Applying monolithic capillary columns based on poly(styrene/divinylbenzene), the influence of acidic eluents based on trifluoroacetic and heptafluorobutyric acid as well as an alkaline eluent based on triethylamine-acetic acid (pH 9.2) on the separation of synthetic phosphopeptides was evaluated. Heptafluorobutyric acid offered the longest retention times and highest selectivities and, hence, the most effective separation. Application of the alkaline eluent in conjunction with detection in negative ion mode electrospray ionization mass spectrometry, on the other hand, allowed the detection of phosphorylated peptides with significantly lower limits of detection, as compared to acidic eluents in combination with detection in positive ion mode. Pairs of phosphorylated and nonphosphorylated synthetic peptides, ranging from 7- to 16-mers, as well as phosphorylated peptides form a tryptic protein digest could be separated both at acidic and alkaline pH. Utilizing a 60 x 0.20-mm-i.d. capillary column, the limit of detection in negative ion detection mode for a 4-fold phosphorylated peptide in a beta-casein digest was 10 fmol. Together with the capability for fast separation of protein digests, monolithic columns, thus, facilitate the effective and sensitive analysis of this important posttranslational modification.

Chromatography, Liquid↗

Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Ion mobility spectrometry (IMS) has been explored for decades, and its versatility in separation and identification of gas-phase ions is well established. Recently, field asymmetric waveform IMS (FAIMS) has been gaining acceptance in similar applications. Coupled to mass spectrometry (MS), both IMS and FAIMS have shown the potential for broad utility in proteomics and other biological analyses. A major attraction of these separations is extremely high speed, exceeding that of condensed-phase alternatives by orders of magnitude. However, modest separation peak capacities have limited the utility of FAIMS and IMS for analyses of complex mixtures. We report 2-D gas-phase separations that join FAIMS to IMS, in conjunction with high-resolution and accuracy time-of-flight (TOF) MS. Implementation of FAIMS/IMS and IMS/MS interfaces using electrodynamic ion funnels greatly improves sensitivity. Evaluation of FAIMS/IMS/TOF performance for a protein mixture tryptic digest reveals high orthogonality between FAIMS and IMS dimensions and, hence, the benefit of FAIMS filtering prior to IMS/MS. The effective peak capacities in analyses of tryptic peptides are approximately 500 for FAIMS/IMS separations and approximately 10(6) for 3-D FAIMS/IMS/MS, providing a potential platform for ultrahigh-throughput analyses of complex mixtures.

Gases↗

Ultrahigh-throughput proteomics using fast RPLC separations with ESI-MS/MS.

We describe approaches for proteomics analysis using electrospray ionization-tandem mass spectrometry coupled with fast reversed-phase liquid chromatography (RPLC) separations. The RPLC separations used 50-microm-i.d. fused-silica capillaries packed with submicrometer-sized C18-bonded porous silica particles and achieved peak capacities of 130-420 for analytes from proteome tryptic digests. When these separations were combined with linear ion trap tandem mass spectrometry measurements, approximately 1000 proteins could be identified in 50 min from approximately 4000 identified tryptic peptides; approximately 550 proteins in 20 min from approximately 1800 peptides; and approximately 250 proteins in 8 min from approximately 700 peptides for a S. oneidensis tryptic digest. The dynamic range for protein identification with the fast separations was determined to be approximately 3-4 orders of magnitude of relative protein abundance on the basis of known proteins in human blood plasma analyses. We found that 55% of the MS/MS spectra acquired during the entire analysis (and up to 100% of the MS/MS spectra acquired from the most data-rich zone) provided sufficient quality for identifying peptides. The results confirm that such analyses using very fast (minutes) RPLC separations based on columns packed with microsized porous particles are primarily limited by the MS/MS analysis speed.

Chromatography, High Pressure Liquid↗

Making broad proteome protein measurements in 1-5 min using high-speed RPLC separations and high-accuracy mass measurements.

The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both time-of-flight (TOF) and Fourier transform ion cyclotron resonance (FTICR) MS were applied for identifying peptides using the accurate mass and time (AMT) tag approach. Peptide RPLC relative retention (elution) times that were generated by solvent gradients that differed by at least 25-fold were found to provide relative elution times that agreed to within 5%, which provides the basis for using peptide AMT tags for higher throughput proteomics measurements. For fast MS acquisition speeds (e.g., 0.2 s for TOF and either approximately 0.3 or approximately 0.6 s for FTICR), peptide mass measurement accuracies of better than +/-15 ppm were obtained with the high-speed RPLC separations. The ability to identify peptides and the overall proteome coverage was determined by factors that include the separation peak capacity, the sensitivity of the MS (with fast scanning), and the accuracy of both the mass measurements and the relative RPLC peptide elution times. The experimental RPLC relative elution time accuracies of 5% (using high-speed capillary RPLC) and mass measurement accuracies of better than +/-15 ppm allowed for the confident identification of >2800 peptides and >760 proteins from >13,000 different putative peptides detected from a Shewanellaoneidensis tryptic digest. Initial results for both RPLC-ESI-TOF and RPLC-ESI-FTICR MS were similar, with approximately 2000 different peptides from approximately 600 different proteins identified within 2-3 min. For <120-s proteomic analysis, TOF MS analyses were more effective, while FTICR MS was more effective for the >150-s analysis due to the improved mass accuracies attained using longer spectrum acquisition times.

Animals↗

Two-dimensional electrophoretic separation of proteins using poly(methyl methacrylate) microchips.

The work presented herein describes highly efficient, two-dimensional (2D) electrophoretic separations of proteins in a PMMA-based microchip. Sodium dodecyl sulfate microcapillary gel electrophoresis (SDS micro-CGE) and micellar electrokinetic chromatography (MEKC) were used as the separation modes for the first and second dimension of the electrophoresis, respectively. The microchip was prepared by hot embossing into PMMA from a brass mold master fabricated via high-precision micromilling. The microchip incorporated a 30-mm SDS micro-CGE and a 10-mm MEKC dimension length. Electrokinetic injection and separation were used with field strengths of up to 400 V/cm. Alexa Fluor 633 conjugated proteins, ranging in size from 38 to 110 kDa, were detected using laser-induced fluorescence with excitation/emission at 633/652 nm. Average plate numbers (N) of 4.8 x 10(4) and 1.2 x 10(4) were obtained in the SDS micro-CGE and MEKC separation dimensions, respectively, for the investigated proteins corresponding to plate heights (H) of 0.62 and 0.87 microm. Effluents from the first dimension (SDS micro-CGE) were repetitively transferred into the second dimension every 0.5 s of run time in the first dimension with the electrophoresis run time in the MEKC dimension being 10 s. The 2D separation was performed on the investigated proteins in approximately 12 min and provided a peak capacity of approximately 1000.

Electrophoresis, Gel, Two-Dimensional↗

Self-associating block copolymer networks for microchip electrophoresis provide enhanced DNA separation via "inchworm" chain dynamics.

We describe a novel class of DNA separation media for microchip electrophoresis, "physically cross-linked" block copolymer networks, which provide rapid (<4.5 min) and remarkably enhanced resolution of DNA in a size range critical for genotyping. Linear poly(acrylamide-co-dihexylacrylamide) (LPA-co-DHA) comprising as little as 0.13 mol % dihexylacrylamide yields substantially improved electrophoretic DNA separations compared to matched molar mass linear polyacrylamide. Single-molecule videomicroscopic images of DNA electrophoresis reveal novel chain dynamics in LPA-co-DHA matrixes, resembling inchworm movement, to which we attribute the increased DNA resolution. Substantial improvements in DNA peak separation are obtained, in particular, in LPA-co-DHA solutions at polymer/copolymer concentrations near the interchain entanglement threshold. Higher polymer concentrations yield enhanced separations only for small DNA molecules (<120 base pairs). Hydrophobically cross-linked networks offer advantages over conventional linear polymers based on enhanced separation performance (or speed) and over chemically cross-linked gels because hydrophobic cross-links can be reversibly broken, allowing facile microchannel loading.

DNA↗

Separation of no-carrier-added 52Mn from bulk chromium: a simulation study for accelerator mass spectrometry measurement of 53Mn.

53Mn radionuclide (T(1/2) = 3.7 x 10(6) y) is produced through the interaction of cosmic rays. Measurements of concentrations of 53Mn in rocks might help to understand Earth surface processes that occurred in time periods not accessible with other cosmogenic nuclides. Only accelerator mass spectrometry (AMS) can determine such ultratrace levels of 53Mn. The main interference in the detection of 53Mn by AMS is its stable isobar 53Cr, which is roughly approximately 10(12) times more abundant in nature. A prerequisite of any AMS measurement of 53Mn in geological samples is therefore chromium separation by an efficient chemistry. Thus, we have developed a method for the separation of chromium and manganese by using a radiometric simulation. The separation procedure was monitored by 51Cr (T(1/2) = 27.70 d) and 52Mn (T(1/2) = 5.59 d) as the corresponding radiotracers for chromium and manganese, respectively. The separation studies were performed by a liquid-liquid extraction technique using trioctylamine (TOA) diluted in cyclohexane. A high separation factor (approximately 16 000) for Mn and Cr can be obtained at optimal conditions of 0.8 M TOA and 9 M HCl. The developed method has been found equally applicable for real geological samples such as manganese crusts, lava, and sediment samples. Therefore, the method offers an important tool to improve 53Mn measurements by AMS.

Journal Article↗

Characterization of capillary-channeled polymer fiber stationary phases for high-performance liquid chromatography protein separations: Comparative analysis with a packed-bed column.

Capillary-channeled polymer (C-CP) fibers are investigated as reversed-phase (RP) stationary phases for high-performance liquid chromatography of proteins. A comparative analysis of column characteristics for polypropylene and poly(ethylene terephthalate) C-CP fiber columns and a conventional packed-bed (C4-derivatized silica) column has been undertaken. Five proteins (ribonuclease A, cytochrome c, lysozyme, myoglobin, bovine serum albumin) were used to investigate the separation characteristics under typical RP gradient conditions. Column performance was compared under standard (identical) and optimized RP chromatographic conditions. The gradient compositions utilized with the C-CP fiber columns are similar to those used with conventional columns, employing flow rates in the 1-6 mL/min range and gradient rates of approximately 1%/min. The packed-bed column was operated as prescribed by the column manufacturer. The retention factor (k'), separation factor (alpha), resolution (Rs), asymmetry factor (As), elution order, and peak capacity values of a four protein separations performed on the C-CP fiber columns are compared to the same separation on the C4 column. One unique feature observed here is the lessening of the percentage of organic modifier necessary to elute the proteins from the fiber phases with increased linear velocity. The potential contribution of the different stationary phases to protein denaturation was evaluated through a spectrophotometric enzymatic activity assay. The repeatability of retention times under both sets of conditions for six consecutive injections of lysozyme on each C-CP fiber column is < or =1.5% RSD. The column-to-column reproducibility of retention times for three columns of each fiber type is also < or =1.5% RSD. The overall performance of the C-CP fiber columns was comparable to the conventional column used in these studies. Basic characteristics demonstrated here suggested further developments in the areas of ultrafast protein separations and preparative-scale protein chromatography.

Animals↗

Monolithic porous polymer layer for the separation of peptides and proteins using thin-layer chromatography coupled with MALDI-TOF-MS.

Plates for thin-layer chromatography (TLC) with an attached layer of porous polymer monolith have been prepared and used for the separation of small molecules, peptides, and proteins. The 50-200-mum. thin poly(butyl methacrylate-co-ethylene dimethacrylate) layers were prepared in situ using UV-initiated polymerization. Precise control of the reaction conditions enables the preparation of monolithic layers with a well-defined porous structure that determines the chromatographic performance. Compared to conventional TLC and high-performance TLC using precoated layers based on silica, the small layer thickness and absence of any binder is expected to improve both retention characteristics and separation efficiency of the polymer-based monolithic thin-layer chromatographic plates. Spots of the separated compounds were first detected using typical UV imaging. Since the monolithic thin layers can be also prepared directly on the stainless steel MALDI carrier plate, the separation in TLC format can be coupled with MALDI-TOF-MS. Application of a conventional MALDI matrix facilitated desorption and ionization of peptides and proteins for molecular weight determination of the separated compounds.

Chromatography, Thin Layer↗

Silver(I)-mediated separations by capillary zone electrophoresis and micellar electrokinetic chromatography: argentation electrophoresis.

The addition of Ag(I) to the run buffer in capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC), containing sodium dodecyl sulfate, applies the principles of argentation chromatography to electrophoretic separations and is termed "argentation electrophoresis". This technique is shown to provide a complementary method to CZE and MEKC for the separation of specific types of solutes that selectively complex with Ag(I). Baseline resolution in the CZE separation of nine sulfonamides is achieved by the addition of 50 mM silver nitrate to the run buffer. Retention mechanisms in MEKC separations can also be manipulated by the addition of Ag(I) to the micellar solution. Only slight resolution of a pair of sulfonamides was achieved under normal MEKC conditions. Upon the addition of Ag(I) to the mobile phase containing SDS micelles, baseline resolution of the compounds is shown. The retention order and resolution of five sulfonamides changed significantly when 25 mM Ag(I) was added to the SDS-containing buffer. The use of Ag(I) addition in MEKC is also applied to the separation of various other compounds that show selectivity toward Ag(I) complexation, including S-containing heterocycles and vitamin D compounds. The effect of the addition of Ag(I) on the elution range in MEKC is also investigated. A steady increase in the elution range is seen upon increasing the concentration of Ag(I). With a constant percentage of organic modifier (15%), the addition of higher concentrations of silver nitrate (25-50 mM) results in elution ranges greater than 12. The results using Ag(I) as buffer additives in MEKC are also compared to studies utilizing a mixed counterion surfactant of sodium/silver dodecyl sulfate.

Electrochemistry↗

Polymer- versus silica-based separation media: elimination of nonspecific interactions in the chiral recognition process through functional polymer design.

A novel chiral stationary phase that contains a new chiral selector based on L-valine-3,5-dimethylanilide attached to monodisperse poly(glycidyl methacrylate-co-ethylene dimethacrylate) beads has been prepared. The polymeric separation medium provides greatly enhanced enantioselectivities and reduced retention times when compared to the analogous silica-based chiral stationary phase in the separation of the enantiomers of 3,5-dinitrobenzamido derivatives of alpha-amino acids under normal-phase HPLC conditions. Separation factors (alpha) of up to 7 were achieved with the polymeric separation medium, which is also useful for the separation of large samples under overload conditions.

Chemistry Techniques, Analytical↗

Sodium dodecyl sulfate-Tween 20 mixed micellar electrokinetic chromatography for separation of hydrophobic cations: application to adrenaline and its precursors.

Separation of hydrophobic cations in capillary electrophoresis under the mixed micellar system composed of SDS and Tween 20 was investigated from the viewpoints of thermodynamics and practical application. Hydrophobic cations interact strongly with the anionic SDS micelle, and this often lead to predominant dissolution of the analytes into the micellar phase, resulting in poor resolution. The ionic interaction was evaluated to be close in strength to the hydrophobic interaction between benzenes and the SDS micelle. Tween 20 as a component to the mixed micelle was found to weaken the attractive ionic interactions between the cationic solutes and SDS. In addition, the polyether chain of Tween 20 serves also as a hydrogen acceptor to cause the attractive hydrogen-bonding interactions with hydrogen-donating analytes. The two different functions of Tween 20 improve the separation of hydrophobic cations remarkably. Separation patterns are well controlled by varying the mixing ratio of the two surfactants. Adrenaline and its six precursors were successfully separated with this mixed micellar system. The improved separation efficiency was not affected by the presence of bovine serum matrix, realizing the direct MEKC analysis of serum sample without deproteination, in which proteins were comigrated with the micelle.

Animals↗

Application of classical gel electrophoresis to the chiral separation of milligram quantities of terbutaline.

Although the last couple of decades has been tremendous progress in the ability to do chiral separations, the ability to do larger scale chiral separations has lagged somewhat behind the current analytical chiral separation state of the art. The potential of classical gel electrophoresis for chiral separation of milligram quantities of chiral material is examined. A protocol for the chiral separation of milligram quantities of terbutaline using sulfated cyclodextrin as a chiral additive is demonstrated. The possible advantages of the approach are discussed.

Adrenergic beta-Agonists↗

Chiral separations using dipeptide polymerized surfactants: effect of amino acid order.

Chiral separations using various polymerized dipeptide surfactants in electrokinetic capillary chromatography (EKC) are investigated. The two main dipeptide surfactants used in this study were sodium N-undecylenyl-L-valine-L-leucine (L-SUVL), and sodium N-undecylenyl-L-leucine-L-valine (L-SULV). These studies were performed in order to determine if the order of amino acids in dipeptide surfactants is important in terms of chiral recognition and separations. Both the monomer and the polymer of these two surfactants were compared for the separation of two model atropisomers, (+/-)-1,1-bi-2-naphtol (BOH) and (+/-)-1,1'-bi-2-naphthyl-2,2'-diyl hydrogen phosphate (BNP). Some advantages and disadvantages of the polymer relative to the monomer are discussed. Four other surfactants, the polymers of sodium N-undecylenyl-L-leucine-L-leucine (L-SULL), sodium N-undecylenyl-L-valine-L-valine (L-SUVV), sodium N-undecylenyl-L-valine (L-SUV), and sodium N-undecylenyl-L-leucine (L-SUL), were also used in this study, and their performance was compared to that of poly(L-SULV). These data show conclusively that the order of amino acids in dipeptide surfactants has a dramatic effect on chiral recognition. Our investigations indicate that poly-(L-SULV) provides the best enantioselectivity among the four dipeptide and two single amino acid surfactants for the separation of BNP and BOH. The advantages of poly-(L-SULV) are demonstrated via the ultrafast separation of the enantiomers of BNP and BOH in less than 1 min.

Amino Acids↗

Separation of chemical warfare agent degradation products by the reversal of electroosmotic flow in capillary electrophoresis.

We report the development of analyses for nerve agent degradation products or related species by the reversal of electroosmotic flow in capillary electrophoresis (CE). The developed methods were used in this laboratory for analysis of samples in the second and third official proficiency tests (International Round-Robins) for the Provisional Technical Secretariat/Preparatory Commission for the Organization for the Prohibition of Chemical Weapons, and those results are reported here. Analytes studied include methylphosphonic acid (a dibasic acid), the monoisopropyl ester of ethylphosphonic acid, and the monoalkyl esters of methylphosphonic acid (R = ethyl, isopropyl, isobutyl, pinacolyl (3,3-dimethyl-2-butyl), cyclohexyl, and 2-ethylhexyl). The cationic surfactants used here for the reversal of electroosmotic flow are didodecyldimethylammonium hydroxide and cetyltrimethylammonium hydroxide. CE methods using conductivity or indirect UV detection provide a good separation efficiency and very high sensitivity for the analysis of such compounds. The detection limits for these species were about 75 micrograms/L when using conductivity detection and about 100 micrograms/L when using indirect UV detection. Because pH plays an important role in the CE separation of the alkylphosphonic acids and their monoesters, the influence of pH on these separation systems was investigated. Electrolytes were stable for at least 3 months. Excellent separation efficiency and freedom from interference due to common anions were obtained in the developed methods which typically achieved complete separations in less than 3 min. The method was applied to aqueous leachates of soil, wipes of surfaces, and vegetation sampled from a field site known to have been exposed to nerve agents and subsequently cleaned up. The data from these environmental samples indicated that the method can be expected to be useful for environmental monitoring.

Chemical Warfare Agents↗

Effective and reproducible capillary electrophoretic separation of thiols under conditions where exceptionally high current is generated.

There is an escalating interest in the role of endogenous nitric oxide (NO) in biological systems and how this chemical regulates physiology in normal and disease states. In biological systems, the cellular concentration can be estimated, in the simplest form, by accounting for NO and its common metabolites, nitrate and nitrite. However, since NO is also known to interact with other chemical entities, such as thiols, it would be valuable to have a rapid qualitative assay that could account for thiol binding and S-N bond cleavage in the presence of different reducing agents. A separation buffer consisting of 10 mM phosphate, 10 mM HCl, and 250 mM KCl is shown to be adequate for the separation of glutathione, nitrosylated glutathione, and glutathione disulfide solubilized in 2 M HCl. The current observed under these separation conditions (249 microA at 11 kV) is extremely high by capillary electrophoresis (CE) standards, with a total power (current x voltage/capillary length) calculated to be in excess of 7 W/m. While this exceeds the approximately 1.0 W/m recommended by previous studies as a maximum for CE-based separations, we demonstrate that effective CE separation of thiols can, in fact, be accomplished under these conditions with acceptable reproducibility, provided that buffer depletion issues are addressed.

Electricity↗

Comblike, monodisperse polypeptoid drag-tags for DNA separations by end-labeled free-solution electrophoresis (ELFSE).

The development of innovative technologies designed to reduce the cost and increase the throughput of DNA separations continues to be important for large-scale sequencing and genotyping efforts. We report research aimed at the further development of a free-solution bioconjugate method of DNA size separation by capillary electrophoresis (CE), in particular, the determination of an optimal molecular architecture for polyamide-based "drag-tags". We synthesized several branched poly(N-methoxyethyl glycine)s (poly(NMEG)s, a class of polypeptoids) as novel friction-generating entities for end-on attachment to DNA molecules. A 30-mer poly(NMEG) "backbone," comprising five evenly spaced reactive epsilon-amino groups, was synthesized on solid phase, cleaved, and purified to monodispersity by RP-HPLC. Three different comblike derivatives of this backbone molecule were created by (1) acetylating the epsilon-amino groups or (2) appending small, monodisperse NMEG oligomers (a tetramer and an octamer). Grafting of the oligo(NMEG)s was done using solution-phase amide bond formation chemistry. Once purified to total monodispersity, the three different drag-tags were studied by free-solution electrophoresis to observe the effect of branching on their hydrodynamic drag or "alpha" and hence their ability to separate DNA. Drag was found to scale linearly with total molecular weight, regardless of branch length. The octamer-branched drag-tag-DNA conjugate was used to separate ssDNA products of 50, 75, 100, and 150 bases in length by free-solution CE in less than 10 min. Hence, the use of branched or comblike drag-tags is both a feasible and an effective way to achieve high frictional drag, allowing the high-resolution separation of relatively large DNA molecules by free-solution CE without the need to synthesize very long polymers.

Acetylation↗

Kinetic characterization of the strand separation ("helicase") activity of the DNA packaging enzyme from bacteriophage lambda.

Bacteriophage lambda is assembled from preformed viral capsids (proheads), tails, and genomes that are excised from a concatemeric DNA precursor. The enzyme responsible for insertion of the genome into the precapsid is known as terminase. This enzyme possesses site-specific endonuclease, ATPase, and DNA strand separation ("helicase") catalytic activities, which work in concert to excise and package a single viral genome during phage assembly. We have previously characterized the endonuclease [Tomka, M. A., & Catalano, C. E. (1993) J. Biol. Chem. 268, 3056-3065] and ATPase [Tomka, M. A., & Catalano, C. E. (1993) Biochemistry 32, 11992-11997] catalytic activities of lambda terminase and present here similar studies on the strand separation activity of the enzyme. Strand separation requires terminase, divalent metal, and adenosine nucleotides with a hydrolyzable beta,gamma-phosphate bond. Two apparent binding sites for ATP-mediated strand separation were identified, one of which appears to be distinct from the high- and low-affinity sites previously observed for ATP hydrolysis [Hwang, Y., Catalano, C. E., & Feiss, M. (1995) Biochemistry 35, 2796-2803]. Salt stimulates the reaction at low concentrations but is strongly inhibitory at elevated concentrations, presumably due to impaired DNA binding. The above results are identical with either a complex DNA mixture (a nicked, annealed DNA duplex in the presence of excess nonspecific DNA) or a purified DNA substrate; however, a kinetic analysis of the reaction revealed that the observed rate was approximately 5-fold greater with the purified DNA substrate. Moreover, while Escherichia coli integration host factor (IHF) stimulates terminase-mediated strand separation with both substrates, the observed stimulation is more pronounced with the complex DNA mixture (10-fold rate increase) than the purified DNA substrate (5-fold rate increase). Our data are consistent with a model where IHF binding to the terminase assembly site forms a binary protein.DNA complex readily distinguishable from bulk DNA. The implications of these results to the process of DNA packaging in bacteriophage lambda are discussed.

Adenosine Triphosphatases↗