Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89Linked to original sources

Fiber-optic-based biomonitoring of benzene derivatives by recombinant E. coli bearing luciferase gene-fused TOL-plasmid immobilized on the fiber-optic end.

TOL plasmid in Pseudomonas putida mt-2 has a series of genes for the degradation of xylene, toluene, and their derivatives to pyruvate and acetaldehyde (or propionaldehyde). Two operons, i.e., upper operon and meta operon, play indispensable roles for the digestion of xylene derivatives: When XyIR protein recognizes xylene derivatives, another controlling gene, xyIS, is activated, which results in the activation of meta operon. Therefore, we have constructed a fusion gene between TOL plasmid and the firefly luciferase gene under the control of XyIR and the promoter of xyIS gene; i.e., by using fusions of the meta operon with promotorless luciferase expression vector from firefly, we have constructed and tested biomonitors for benzene derivatives. Bioluminescence specified by Escherichia coli (pTSN316), carrying xyIR and xyIS promoters, Ampr and luc, was measured in either a benzene derivative-saturated or o-methylbenzyl alcohol-dissolved medium both in the case of cell suspension and in the case of immobilized cell form. The utility of the biosensing system for monitoring in chemical plant drainage was demonstrated with samples supplemented with benzene derivatives. The xyIR-xyIS promoter-lux fusion carried by pTSN316 responded to a benzene-related chemical in sample solutions. Immobilization of the transformed E. coli, at one end of fiber optic, bearing firefly luciferase gene fused to TOL plasmid, has been demonstrated to fabricate a luminescent remote biomonitoring device for the protection of environmental deterioration. Due to the luminescent detection, the detection limits for benzene-related aromatics that are recognized by a binding protein (XyIR) were parts-per-million. We had already submitted a preliminary report concerning the possibility of environmental monitoring based on the above idea by using the transformed E. coli in a cell-suspended solution. This paper describes mainly a fiber-optic-based biomonitoring device for the protection of environmental deterioration.

Bacterial Proteins↗

[Plastics on the eye - plastics in the eye. Human-optic materials].

BACKGROUND: Materials of identical or similiar chemical classes are used for contact optics as well as for implantable intraocular devices. All of them derive from the chemistry of industrial product developments. PATIENTS AND METHODS: Materials used in and on the eye should behave indifferent. They should not provoke any reaction in the eye and not themselves be altered by the biological surroundings. For materials used in the eye an especially high purity of the polymers utilized as well as a long term light stability is to be demanded. Optical properties like transparency have to be stable over extended time periods under normal light influence. The long time stability of UV-absorbing additives in the materials used has to be verified. RESULTS: All materials used for IOL's - with the exception of the homopolymer of methylmethacrylate - consist of polymer mixtures forming socalled interpenetrating networks which appear as an uniform material. For the manufacturing of intraocular lense materials standardized or unanimous producer prescriptions are not existing. Based on the different polymer formulations different aging and fatigue properties are the outcome. In addition only inadequate knowledge about the long term light stability of the incorporated UV blockers is submitted. CONCLUSIONS: Polymeric materials used for IOL's should be subjected in addition to the test methods listed in EN-ISO 11 979/5 to chemical, polymeranalytic and mechanical substance examinations. As a standard in such examinations a polymethylmethacrylate, free of methylacrylate is proposed. Examinations of each lot should be compulsory. Identification of all ingredients of the intraocular materials should be prescribed and labeled in line with the revelations of common medical drugs prescriptions. The relevations commit the medical doctor to inform his patient about possible side effects of the intraocular implants.

Biocompatible Materials↗

Chaotic filtering of moving atoms in pulsed optical lattices by control of dynamical localization.

We propose a mechanism for a velocity-selective device which would allow packets of cold atoms traveling in one direction through a pulsed optical lattice to pass undisturbed, while dispersing atoms traveling in the opposite direction. The mechanism is generic and straightforward: for a simple quantum kicked rotor pulsed with unequal periods, the quantum suppression of momentum diffusion (dynamical localization) yields momentum localization lengths L which are no longer isotropic, as in the standard case, but vary smoothly and controllably with initial momentum.

Journal Article↗

[Monitoring of intracranial pressure].

A very small fiberoptic catheter initially developed as an intravascular pressure sensor was incorporated into a system to be used as an intracranial pressure (ICP) monitor. 13 patients with intracranial hypertension have been studied with this probe. The clinical experience confirmed the safety, accuracy and reliability of the device. The monitor has functioned very well, and there have been no complications except for two breakages of optic fiber as a result of nursing manoeuvres. This new device can be placed into the ventricular, subdural and epidural space. Camino System appears to offer advantages over other monitors presently in use.

Adult↗

Compound eyes: old and new optical mechanisms.

Over the last twenty years classical views of how compound eyes work optically have undergone a series of overhauls. Exner's central concept of an optically inhomogeneous lens cylinder has survived, and such devices are now made commercially. He was wrong, however, about some crustacean eyes. They produce images by a mirror mechanism that was not discovered until 1975, and which now shows promise as an optical system capable of development.

Coleoptera↗

Pushing the limits of lithography

The phenomenal rate of increase in the integration density of silicon chips has been sustained in large part by advances in optical lithography--the process that patterns and guides the fabrication of the component semiconductor devices and circuitry. Although the introduction of shorter-wavelength light sources and resolution-enhancement techniques should help maintain the current rate of device miniaturization for several more years, a point will be reached where optical lithography can no longer attain the required feature sizes. Several alternative lithographic techniques under development have the capability to overcome these resolution limits but, at present, no obvious successor to optical lithography has emerged.

Journal Article↗

In-line liquid-crystal microcell wave plates and their application for high-speed, reset-free polarization mode dispersion compensation in 40-Gbit/s systems.

We describe the design, fabrication, and performance of a high-speed, continuously tunable, and reset-free polarization controller based on nematic liquid-crystal (NLC) microcell wave plates fabricated directly between the tips of optical fibers. This controller utilizes a pulsed driving scheme and optimized NLC materials to achieve a stepwise switching speed of 1 deg/micros, for arbitrary rotation angles with moderately low voltages. This compact microcell design requires no bulk optical components and has the potential to have low insertion loss. We describe the performance of these devices when implemented in polarization mode dispersion compensators for 40 Gbit/s systems. The good optical properties and the nonmechanical, high-speed, and low-power operation suggest that this type of device might be considered for some applications in dynamic compensation of polarization mode dispersion, polarization analysis, polarization division demultiplexing, and polarization scrambling in high-speed optical communication systems.

Journal Article↗

Quality analysis of in vivo near-infrared fluorescence and conventional gamma images acquired using a dual-labeled tumor-targeting probe.

The cyclic peptide, cyclopentapeptide cyclo(lys-Arg-Gly-Asp-phe) (c(KRGDf)), which is known to target alpha(v)beta3 integrin, is dual-labeled with a radiotracer, (111)indium, for gamma scintigraphy as well as with a near-infrared dye, IRDye800, for continuous-wave (cw) imaging of alpha(v)beta3 positive human M21 melanoma in xenografts. Twenty-four hours after administration of the dual-labeled peptide at a dose equivalent to 90 microCi of (111)In and 5 nmol of near-infrared (NIR) dye, whole-body gamma scintigraphy and cw imaging was conducted. Image acquisition time was 15 min for the gamma scintigraphy images and 800 ms for the optical images acquired using an NIR sensitive intensified charge-coupled device. The results show that while the target-to-background ratio (TBR) of nuclear and optical imaging were similar for surface regions of interest and consistent with the origin of gamma and NIR radiation from a common targeted peptide, the signal-to-noise ratio (SNR) was significantly higher for optical than nuclear imaging. Furthermore, an analysis of SNR versus contrast showed greater sensitivity of optical over nuclear imaging for the subcutaneous tumor targets. While tomographic reconstructions are necessary to probe TBR, SNR, and contrast for interior tissues, this work demonstrates for the first time the direct comparison of molecular optical and planar nuclear imaging for surface and subsurface cancers.

Animals↗

Measurement of tumor oxygenation: a comparison between polarographic needle electrodes and a time-resolved luminescence-based optical sensor.

A novel oxygen sensor which does not rely on electrochemical reduction has been used to measure the oxygenation of the murine sarcoma F in a comparative study with an existing polarographic electrode that is available commercially. The prototype luminescence sensor yielded an oxygen distribution comparable with readings made using a pO2 histograph. The percentage of regions detected that had a pO2 less than 5 mm Hg was 79 and 75 using the Eppendorf pO2 histograph and the luminescence fiber optic sensor, respectively. These values were compatible with a measured radiobiologically hypoxic fraction of 67% in this tumor. The polarographic method detected more regions with a pO2 of 2.5 mm Hg or less (69%) compared with the optical sensor (50%) (P < 0.05). This could reflect differences in the oxygen use of the sensing devices. This initial assessment indicates the potential of a fiber-optic-based oxygen-monitoring system. Such a system should have several advantages including monitoring temporal oxygen changes in a given microregion and use with NMR procedures.

Animals↗

Imaging of hippocampal neural activity in freely behaving animals.

We examined intrinsic activity of neurons in the cat dorsal hippocampus following stimulation of the posterior medial hypothalamus and following a 2.5 mg/kg intravenous administration of cocaine. Posterior hypothalamic stimulation elicited banding of optical activity in the dorsal hippocampus, suggestive of spatial organization of neural activity underlying synchronous rhythmical slow wave activity. Cocaine administration resulted in a major decline in reflected light at 700 nm, possibly representing diminished oxygenation to the underlying tissue. The activity was examined by a new technique which uses principles of reflectance at specific bandwidths of light during cellular activity, and allows acquisition of images in the freely behaving animal. The imaging device consists of a 1.6 mm diameter coherent optic fiber bundle of 25 microns fibers attached to a 128 x 128 pixel charge-coupled device (CCD) array which can be cooled to reduce thermal noise. The target is illuminated by a light emitting diode array producing light at a number of operator-selectable narrow bandwidths which permits assessment of physiological characteristics of neural tissue. The CCD output is digitized, stored by computer, and the resulting images are averaged to obtain a greater signal-to-noise ratio. The procedure shows considerable promise for providing on-line, real-time indications of activity in localized brain regions.

Animals↗

Mapping cone- and rod-induced retinal responsiveness in macaque retina by optical imaging.

PURPOSE: To map the distribution of cone- or rod-induced retinal responsiveness by optical imaging from macaque retina. METHODS: The light reflectance changes in the posterior retina after a flash stimulus in anesthetized rhesus monkeys were measured by a modified fundus camera system equipped with a charge-coupled device (CCD) camera. The response topography of the optical signals was obtained in either light- or dark-adapted conditions. RESULTS: With infrared observation light, the whole posterior pole became darkened after the stimulus. The response topography in light-adapted conditions demonstrated a steep peak of darkening at the fovea, together with the gradual decrease of signal intensity away from the fovea toward the periphery. In dark-adapted conditions, the optical signal showed additional peaks along the circular region surrounding the macula at the eccentricity of the optic disc, together with the central peak at the fovea. A statistically significant positive correlation was obtained between the light reflectance changes in infrared observation light and the focal responses in multifocal electroretinogram (mfERG) at the corresponding retinal locations. CONCLUSIONS: The response topography in the retina, obtained by optical imaging, was consistent with psychophysical cone or rod sensitivity in humans and anatomic cone or rod distribution in humans and macaques. The cone- or rod-induced retinal responsiveness within the posterior pole region was noninvasively recorded within a short recording time.

Animals↗

Analysis of red cell and platelet morphology using an imaging-combined flow cytometer.

Laser-based flow cytometry and aperture-impedance methods are still the dominant technologies used for cell analysis in haematology, but both are limited to areas such as morphological analysis of red cell shape and high-sensitivity detection of platelet agglutinates and aggregates. Flow cytometry alone does not provide precise measurement of red cell volume without chemical pretreatment before detection and aperture-impedance is still considered the gold standard in the field of particle volume analysis. In the present study, an experimental prototype instrument called the imaging-combined flow cytometer (IFC) was evaluated. The IFC is equipped with an imaging device consisting of a pulse laser, lens units and a charge-coupled device (CCD) camera in addition to the flow-cytometric optical set-up. A personal computer was attached to the instrument to handle images derived from the imaging device. Laser illumination was triggered so that the image of an object was captured for each exposure of the CCD camera. Objects in the images were used to calculate size and shape information and to compute fractal texture features by image processing after each measurement. The advantage of the IFC is that it can capture images of selected cells of interest at the same time as flow-cytometric detection. Estimation of red cell volume, discrimination of red cells and platelets, and detection of platelet agglutinates and aggregates were attempted using the IFC in combination with image processing, It was found that image analysis on the IFC could provide a substitutional function for mean corpuscular volume (MCV) estimation and detection of platelet agglutinates and aggregates. The additional information generated by the IFC may be useful in diagnostic haematology.

Autoanalysis↗

Histology of AlphaCor skirts: evaluation of biointegration.

PURPOSE: To report histologic findings in 14 AlphaCor artificial corneas implanted during clinical trials and subsequently explanted from human subjects following complications, so as to evaluate biointegration within the device skirt. METHODS: Explants were fixed and sectioned in paraffin. Histologic findings related to the device skirt were compared with earlier histologic results from animal studies and correlated with clinical histories. RESULTS: Two devices had been removed due to complications related to the optic alone, 11 following stromal melting overlying the biointegratable sponge skirt and 1 due to a retroprosthetic membrane. All devices demonstrated normal skirt porosity. Biointegration was similar to that found in animal studies but qualitatively appeared reduced in the affected areas in patients with overlying stromal melting prior to explantation. Patients with a longer history of melting prior to explantation demonstrated presence of inflammatory cells around the device. CONCLUSIONS: Histologic findings of the AlphaCor skirt in humans are consistent with earlier animal studies. This study confirms that biointegration by host fibroblastic cells, with collagen deposition occurs after AlphaCor implantation in humans. In cases in which stromal melting had occurred, biointegration is seen to be reduced. On correlating preoperative clinical factors with biointegration observed histologically, preoperative vascularization appears not to be required for AlphaCor biointegration.

Aged↗

Optically programmable electron spin memory using semiconductor quantum dots.

The spin of a single electron subject to a static magnetic field provides a natural two-level system that is suitable for use as a quantum bit, the fundamental logical unit in a quantum computer. Semiconductor quantum dots fabricated by strain driven self-assembly are particularly attractive for the realization of spin quantum bits, as they can be controllably positioned, electronically coupled and embedded into active devices. It has been predicted that the atomic-like electronic structure of such quantum dots suppresses coupling of the spin to the solid-state quantum dot environment, thus protecting the 'spin' quantum information against decoherence. Here we demonstrate a single electron spin memory device in which the electron spin can be programmed by frequency selective optical excitation. We use the device to prepare single electron spins in semiconductor quantum dots with a well defined orientation, and directly measure the intrinsic spin flip time and its dependence on magnetic field. A very long spin lifetime is obtained, with a lower limit of about 20 milliseconds at a magnetic field of 4 tesla and at 1 kelvin.

Journal Article↗

Wireless spectroscopic compact photonic explorer for diagnostic optical imaging.

A remote, small-size spectroscopic-based device called Compact Photonics Explorer (CPE) was designed, assembled, and tested for medical and non-medical spectroscopic and imaging applications. Spatial images acquired using the spectroscopic CPE are presented. Operational principles are demonstrated for various biomedical and non-medical applications.

Colorimetry↗

Schemes for the optimization of chest radiography using a computer model of the patient and x-ray imaging system.

A computer program has been developed to model chest radiography. It incorporates a voxel phantom of an adult and includes antiscatter grid, radiographic screen, and film. Image quality is quantified by calculating the contrast (deltaOD) and the ideal observer signal-to-noise ratio (SNR(I)) for a number of relevant anatomical details at various positions in the anatomy. Detector noise and system unsharpness are modeled and their influence on image quality is considered. A measure of useful dynamic range is computed and defined as the fraction of the image that is reproduced at an optical density such that the film gradient exceeds a preset value. The effective dose is used as a measure of the radiation risk for the patient. A novel approach to patient dose and image quality optimization has been developed and implemented. It is based on a reference system acknowledged to yield acceptable image quality in a clinical trial. Two optimizations schemes have been studied, the first including the contrast of vessels as measure of image quality and the second scheme using also the signal-to-noise ratio of calcifications. Both schemes make use of our measure of useful dynamic range as a key quantity. A large variety of imaging conditions was simulated by varying the tube voltage, antiscatter device, screen-film system, and maximum optical density in the computed image. It was found that the optical density is crucial in screen-film chest radiography. Significant dose savings (30%-50%) can be accomplished without sacrificing image quality by using low-atomic-number grids with a low grid ratio or an air gap and more sensitive screen-film system. Dose-efficient configurations proposed by the model agree well with the example of good radiographic technique suggested by the European Commission.

Dose-Response Relationship, Radiation↗

Sinusoidal-wavelength-scanning interferometer with double feedback control for real-time distance measurement.

In addition to a conventional phase a the interference signal of a sinusoidal-wavelength-scanning interferometer has a phase-modulation amplitude Zb that is proportional to the optical path difference L and amplitude b of the wavelength scan. L and b are controlled by a double feedback system so that the phase alpha and the amplitude Zb are kept at 3pi/2 and pi, respectively. The voltage applied to a device that displaces a reference mirror to change the optical path difference becomes a ruler with scales smaller than a wavelength. Voltage applied to a device that determines the amplitude of the wavelength scan becomes a ruler marking every wavelength. These two rulers enable one to measure an absolute distance longer than a wavelength in real time.

Journal Article↗

Biomolecule-nanoparticle hybrids as functional units for nanobiotechnology.

Biomolecule-metal or semiconductor nanoparticle (NP) hybrid systems combine the recognition and catalytic properties of biomolecules with the unique electronic and optical properties of NPs. This enables the application of the hybrid systems in developing new electronic and optical biosensors, to synthesize nanowires and nanocircuits, and to fabricate new devices. Metal NPs are employed as nano-connectors that activate redox enzymes, and they act as electrical or optical labels for biorecognition events. Similarly, semiconductor NPs act as optical probes for biorecognition processes. Double-stranded DNA or protein chains that are modified with metallic nanoclusters act as templates for the synthesis of metallic nanowires. The nanowires are used as building blocks to assemble nano-devices such as a transistor or a nanotransporter.

Biotechnology↗