Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fractures, Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89Linked to original sources

[Clinical and neuroradiological evaluation of the long-term surviving siblings of Sanfilippo syndrome A type].

The siblings of Sanfilippo syndrome type A (MPS III A) have been reported. The relationship of their parents was the first cousins. Case 1: A 30-year-old Japanese man was hospitalized because of gait disturbance and mental impairment. His early somatic and mental development was normal until 9 years of age when mental deterioration had developed. Speech and gait disturbances and double incontinence occurred at 18 years of age. He could not walk at 21 years of age. Those symptoms were slowly progressive. Case 2: A 32-year-old Japanese man, the elder brother of case 1, had a similar clinical history to that of case 1. Their neurological findings revealed mental impairment, coarse face, positive forced grasp and sucking reflexes, and pyramidal signs. Lumbar X-ray showed platyspondylitis, compression fracture of L 1 and osteoporotic changes. Brain MRI of both cases showed brain atrophy, ventricular dilatation and abnormal high intensity signals near the posterior horn of the lateral ventricles on T2 weighted image. Low perfusion images of fronto-parietal regions were seen in the early phase of SPECT using 123I-IMP. This siblings were diagnosed as Sanfilippo syndrome type A because of heparan sulfaturia and deficiency of heparan sulfate sulfamidase of the lymphocytes. Average life span of Sanfilippo syndrome type A is not so long but the age of our cases is over 30 years of age.

Adult↗

Paleopathology in osseous remains from the 16th century. A survey of rheumatic diseases.

OBJECTIVE: To describe the rheumatic conditions found in skeletal remains of Amerindian ancestry disinterred from a 16th century Mexican cemetery. METHODS: A physical anthropologist and 2 rheumatologists surveyed the recovered skeletal remains. RESULTS: We examined the skeletal remains of 443 subjects. We found 19 cases of Pott's disease, 17 of osteoarthrosis in various anatomical locations, 2 spondyloarthropathies, probably ankylosing spondylitis or diffuse idiopathic skeletal hyperostosis, one probable septic arthritis in the stemoclavicular joint, and 2 compression fractures of the spine. We found no cases of gout or rheumatoid arthritis. CONCLUSION: This is the first report on the presence of rheumatic conditions in colonial Mexico. Studying the remains of these populations can provide useful information about the origin and evolution of different rheumatic conditions.

Adult↗

[MIDCAB procedure by original stabilizer and usual devices].

UNLABELLED: The key of MIDCAB is how to stabilize the left anterior descending artery. We introduce our MIDCAB procedure by using our original stabilizer and usual devices in this paper. METHOD: Between March 1997 and August 1997, 13 patients underwent left internal thoracic artery to left anterior descending artery revascularization without extracorporeal circulation, and one case underwent right internal thoracic artery to right coronary artery. In all cases, we exposed the internal thoracic artery through a 8 cm anterior fifth space thoracotomy. One case of MIDCAB to right coronary artery was added an inferior hemisternotomy for anastomosis to the right coronary artery. The internal thoracic artery was harvested by using the Kent retractor. The anastomosis were done by using our original stabilizer and retract O tapes. RESULTS: In our method, there was no mortality and no postoperative cardiac event. There were 5 postoperative complications, one was reoperation due to bleeding from a branch of the internal thoracic artery, two cases were wound infection. Cerebral infarction, bleeding due to urinary bladder tumor and lumbar compression fracture was seen in one case each. CONCLUSION: MIDCAB procedure was performed safety and effectively by using our original stabilizer and usual devices.

Aged↗

Different patterns of extension and recurrence in algodystrophy.

A true recurrence at exactly the same site is quite unusual in algodystrophy. Local or regional extension is possible. The bone scan is an easy way to demonstrate that the areas successively affected are not the same. An apparent local recurrence could in fact be a microscopic compression fracture of trabecular bone or cortical fractures or part of a factitious disorder.

Adult↗

Dual-head pinhole bone scintigraphy.

UNLABELLED: This article describes dual-head pinhole bone scintigraphy (DHPBS), which makes use of two opposing pinhole-collimated detectors to obtain one pair of magnified images of bone and joint at one time. The aims are to reduce scan time and solve the problem of the blind zone that is created in the background in single-head pinhole bone scintigraphy. METHODS: DHPBS was used for normal hip and knee joints and one case each of lumbar spondylosis, vertebral compression fracture and pyoankle. The gamma camera used was a digital dual-head SPECT camera (Sopha Camera DST; Sopha Medical Vision International, Buc Cedex, France) connected to an XT data processor and a printer. Each of two opposing detectors was collimated with either a 3- or 5-mm pinhole collimator. The scan was performed 2-3 hr postinjection of 12-25 mCi 99mTc-oxidronate. Some 1500-2000 Kilocounts were accumulated at 15-40 min per pair. Anterior and posterior views were taken for the spine and hip and medial and lateral views for the knee and ankle. DHPBS images were correlated to radiographs. RESULTS: DHPBS produced a pair of high-resolution bone and joint images at one time, reducing scan time by nearly half for each image. The paired DHPBS images clearly visualized both foreground and background objects, which effectively eliminated the blind zone. CONCLUSION: DHPBS can significantly improve efficiency and diagnostic acumen.

Aged↗

Percutaneous compression plating versus compression hip screw fixation for the treatment of intertrochanteric hip fractures.

Percutaneous compression plate (PCCP) devices are used for the fixation of intertrochanteric hip fractures by a minimally invasive technique. One hundred and eight patients who underwent this procedure were retrospectively compared with 155 patients who underwent compression hip screw (CHS) fixation. The general characteristics of the two groups, including age, sex, side of injury and co-morbidities assessed by the ASA score were similar. The operative time was significantly shorter in the PCCP group (67 versus 87 min, p=0.00). Postoperative blood transfusions were not required in 40% of the patients in the PCCP group compared to 24% of the patients in the CHS group (p<0.01). The rate of systemic postoperative complications was lower in the PCCP group (p=0.02) both in univariate and multivariate analyses. A considerable reduction was observed in cardiovascular complications (OR=3.1, p<0.05). Length of hospitalisation, implant failure and mortality rates were not significantly different between the two study groups. We conclude that the PCCP device offers several advantages over CHS device and may improve the current treatment of intertrochanteric hip fractures while maintaining a similar success rate in fracture fixation.

Aged↗

Ipsilateral hip and femoral shaft fractures treated with compression hip screw and long side-plate.

Complex femoral fractures involving the hip and shaft are not rare findings in the emergency room. The primary problem in the care of these patients is the preservation of their lives. The fracture combination under discussion is only a part of the injury complex sustained by these individuals. After the acute problems have been brought under control, care of the fractured femur and hip must be planned. Recently, most centers have favored giving priority to hip fractures, rigid fixation and early mobilization. However, for the fixation implants, variable fixation methods have been reported but are imperfect. In the past 5 years we have had some experience using compression hip screws with long side-plate to fix the different injured parts of these dual shaft and hip fractures at the same time. It seemed that application of these devices in dual hip and proximal shaft fractures, which are devoid of physiological bowing of the shaft, would get the best results. But when they are applied to dual fractures of the hip and the middle portion of the shaft, certain techniques, like adequate distal fixation, the prebending of the plate, primary bone graft and mobilization of the non-weight bearing pattern should be strictly adhered to for assurance of early callus formation and prevention of implant failure.

Adult↗

Volar fixation of dorsally displaced distal radial fracture using locking compression plate.

PURPOSE: To evaluate the functional and radiological results of treating unstable fractures of the dorsal distal radius with a volar locking plate. METHODS: Dorsally displaced distal radial fractures in 30 patients (11 men and 19 women; mean age, 58.6 years) were fixed by volar locking compression plate and followed up for a minimum of one year. RESULTS: At final functional assessment, 24 patients achieved excellent and 5 achieved good outcomes, with one patient exhibiting fair results. Radiological scores demonstrated 22 excellent and 8 good outcomes. No nonunion or infection occurred. CONCLUSION: Volar locking compression plating is a safe and effective treatment for unstable fractures of the dorsal distal radius.

Adult↗

Limited contact dynamic compression in diaphyseal fractures of the humerus: good outcome in 51 patients.

We reviewed 51 plate fixations for fracture of the humeral diaphysis managed during the last 3 years. The indications for surgery included non-union, delayed union, polytrauma, neurological involvement and inadequate reduction. All the fractures were stabilized with a Limited Contact Dynamic Compression Plate (LCDC Plate). We found that this plate gave adequate rotational and vertical stability to the fracture. 48 fractures healed after median 2.5 months. Early evidence of callus formation indicated minimal compromise with the vascularity of bone which may be attributed to the undercut design of the plate, causing relatively less cortical ischemia. In addition, the plate fixation was associated with fewer complications, as compared to those reported with intramedullary nailing.

Adolescent↗

Noninvasive reduction of open-book pelvic fractures by circumferential compression.

OBJECTIVES: To determine the efficacy and optimal application parameters of circumferential compression to reduce external rotation-type pelvic fractures. DESIGN: Biomechanical investigation on human cadaveric specimens. SETTING: Biomechanics laboratory. INTERVENTION: Partially stable and unstable external rotation injuries of the pelvic ring (OTA classification 61-B1 and 61-C1) were created in seven human cadaveric specimens. A prototype pelvic strap was applied subsequently at three distinct transverse levels around the pelvis. Circumferential pelvic compression was induced by gradual tensioning of the strap to attempt complete reduction of the symphysis diastasis. MAIN OUTCOME MEASUREMENTS: Pelvic reduction was evaluated with respect to strap tension and the strap application site. The effect of circumferential compression on intraperitoneal pressure and skin-strap interface pressure was measured. RESULTS: A successive increase in circumferential compression consistently induced a gradual decrease in symphysis diastasis. An optimal strap application site was determined, at which circumferential compression most effectively yielded pelvic reduction. The minimum strap tension required to achieve complete reduction of symphysis diastasis was determined to be 177 +/- 44 Newtons and 180 +/- 50 Newtons in the partially stable and unstable pelvis, respectively. CONCLUSIONS: Application of circumferential compression to the pelvic soft tissue envelope with a pelvic strap was an efficient means to achieve controlled reduction of external rotation-type pelvic fractures. This study derived application parameters with direct clinical implication for noninvasive emergent management of traumatic pelvic ring disruptions.

Aged↗

An in vitro study of the compressive load at fracture of Procera AllCeram crowns with varying thickness of veneer porcelain.

STATEMENT OF PROBLEM: When designing and cutting a crown preparation, a balance must be achieved between the amount of tooth structure conserved and the space created for the restoration. All-ceramic crowns, which contain a core, are usually veneered with porcelain to produce the desired aesthetics and contour. The effect of veneer porcelain on the strength of the restoration has been a cause of debate. PURPOSE: The purpose of this study was to investigate the effect of different thickness of veneer porcelain on the compressive load at fracture of Procera AllCeram crowns. MATERIAL AND METHODS: Sixty brass dies were fabricated with a crown-like preparation and a chamfer margin. Sixty crowns were fabricated with a 0.6-mm-thick core: Procera crowns with either a 0.4-mm- or 0.9-mm-thick veneer of AllCeram (Groups 1 and 2 respectively) and In-Ceram crowns with a 0.9-mm-thick veneer of Vitadur Alpha porcelain (Group 3). Each group consisted of 20 crowns. In-Ceram crowns were used as the control group. All crowns were measured at 4 axial and 1 occlusal random locations before autoglazing. They were air abraded and adhesively bonded onto the appropriate brass die using Clearfil Newbond Bonding Agent, Clearfil Porcelain Bond Activator, and Panavia 21 TC Dental Adhesive as the luting agent. After storage in distilled water at 37 degrees C for 24 hours, the specimens were placed in a compressive test rig within an Instron universal testing machine and loaded in the center of the occlusal surface with a 4-mm diameter stainless steel ball. An axial preload of 20 N was applied before compressive testing at a crosshead speed of 0.1 mm/minute until fracture occurred. An analysis of variance revealed no significant difference in the load at fracture between the 3 groups (P=.3). Using a Bonferroni correction, independent t tests revealed no significant difference in load at fracture for any of the pair-wise comparisons between the 3 test groups (P < .05). RESULTS: The mean load at fracture for Group 1 was 2197.6 N (SD = 776.4); Group 2, 2401.4 N (SD = 699.1); and Group 3, 2581.0 N (SD = 715.6). CONCLUSION: Within the parameters of this study, the axial thickness of veneer porcelain did not have a significant effect on the compressive load at fracture of Procera AllCeram crowns.

Aluminum Oxide↗

[Stable extraosseous compression osteosynthesis in fractures of the crural bones].

The article deals with the main principles of the conception of stable extraosseous compression osteosynthesis, the necessary conditions for its successful application. Operations were conducted on 87 patients for diaphyseal fractures of the leg bones by means of methods, instruments, and fixators suggested by the Osteosynthesis Association (OA, Switzerland). The late-term results of treatment were followed-up in 80 patients, 8 of them had complications (fracture and migration of the plate, nonunion of the fragments, osteomyelitis, recurrent fractures).

Adolescent↗

[Diffusion-weighted imaging of acute vertebral compression: Differential diagnosis of benign versus malignant pathologic fractures].

PURPOSE: Our purpose was to assess the value of diffusion-weighted steady-state free precession (SSFP) sequence for differentiating between benign and pathologic compression fractures. MATERIALS AND METHODS: Forty-nine patients with 63 acute vertebral compression fractures caused by osteoporosis (n = 23), trauma (n = 7), malignancy (n = 30), infection (n = 3) were examined with a diffusion-weighted SSFP sequence (diffusion gradient strength; 23 mT/m, diffusion pulse length 5 ms), T1-weighted turbo spin-echo sequence, and short-inversion-time (TI 150 ms) T2-weighted turbo inversion recovery sequence. The signal intensity characteristics were analyzed qualitatively and quantitatively for all sequences. Statistical analysis was performed with the Student's t test. RESULTS: In diffusion-weighted MR imaging, benign osteoporotic and traumatic fractures were hypo- to isointense to adjacent normal vertebral bodies. Pathologic and infectious compression fractures were hyperintense to normal vertebral bodies. Pathologic vertebral fractures had positive bone marrow contrast ratios at diffusion-weighted imaging, whereas non infectious benign vertebral fractures had negative values (p < 0.001). The difference in bone marrow contrast ratios for benign and pathologic compression fractures at T1-weighted TSE and T2-weighted turbo IR was not significant (p > 0.01). CONCLUSION: Diffusion-weighted SSFP sequence provides unique information that significantly impacts the accuracy of radiologic diagnosis. Diffusion-weighted SSFP sequence may allow the differentiation of acute benign osteoporotic fractures from malignant compression fractures. Acute benign osteoporotic or traumatic fractures show hypointense or isointense signal on diffusion-weighted sequences that reflects persistent free water proton mobility. Malignant compression fractures show hyperintensity compared with normal surrounding bone marrow probably due to altered water proton mobility within the neoplasm.

Adult↗

The treatment of spinal fractures with Harrington compression rods and segmental sublaminar wiring. A dangerous combination.

The increasing use of more rigid internal fixation constructs for spinal fractures, especially in association with spinal cord injury, has led surgeons to combine sublaminar segmental wiring with Harrington instrumentation systems. Two clinical cases whose neurologic condition deteriorated postoperatively were shown to have sustained direct cord injury by the combination of Harrington compression rods with segmental sublaminar wiring. Myelographic and surgical evidence of hook protrusion into the spinal canal with direct cord injury is presented. Laboratory spine simulations duplicating the clinical situation did demonstrate that sublaminar wiring of the Harrington compression rod system caused the standard hooks to protrude dangerously into the spinal canal. Caution should be exercised not to combine Harrington compression rods with segmental sublaminar wiring.

Female↗

Traumatic abdominal hernia and lateral compression type 1 pelvic fracture: a case report.

Pelvic fractures often are associated with concomitant injuries. In general, the more severe the pelvic fracture, the more likely other, potentially life-threatening injuries exist. We present a case of a typical type 1 lateral compression pelvic fracture with the less common associated injury of abdominal wall muscle disruption and large-bowel herniation.

Abdominal Injuries↗

Anterior interosseous nerve compression after supracondylar fracture of the humerus: a metaanalysis.

OBJECT: The authors conducted a metaanalysis of reports of anterior interosseous nerve syndrome, a rare nerve compression neuropathy that affects only the motor branch of the median nerve. This syndrome is characterized by paralysis of the flexor pollicis longus, the flexor digitorum profundus to the index finger, and the pronator quadratus, with weakness on flexion of the interphalangeal joint of the thumb and the distal interphalangeal joint of the index finger without sensory loss. METHODS: The authors reviewed reports of 34 cases of anterior interosseous nerve syndrome combined with supracondylar fractures of the humerus in children. They have added a new case identified in a 7-year-old boy in whom a diagnosis was made from the clinical findings and whose treatment and outcome are analyzed. The ages of patients reported in the literature ranged from 4 to 10 years. Ten patients (29%) were treated with closed reduction and application of a cast, whereas 25 patients (71%) were treated with open reduction and fixation of the fracture. CONCLUSIONS: All patients regained full flexion and strength after 4 to 17 weeks. The fractures that were surgically treated showed no entrapment of the anterior interosseous nerve.

Casts, Surgical↗