Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Films”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89Linked to original sources

Mobility in thin polymer films ranging from local segmental motion, Rouse modes to whole chain motion: a coupling model consideration.

Large increases of mobility of local segmental relaxation observed in polymer films as the film thickness is decreased, as evidenced by decreases of the glass temperature, are not found for relaxation mechanisms that have longer length scales including the Rouse relaxation modes and the diffusion of entire polymer chains. We show that the coupling model predictions, when extended to consider polymer thin films, are consistent with a large increase of the mobility of the local segmental motions and the lack of such a change for the Rouse modes and the diffusion of entire polymer chains. There are two effects that can reduce the coupling parameter of the local segmental relaxation in thin films. One is the chain orientation that is induced parallel to the surface when the film thickness h becomes smaller than the end-to-end distance of the chains and the other is a finite-size effect when h is no longer large compared to the cooperative length scale. Extremely thin ( approximately 1.5 nm) films obtained by intercalating a polymer into layered silicates have thickness significantly less than the cooperative length scale near the bulk polymer glass transition temperature. As a result, the coupling parameter of the local segmental relaxation in such thin films is reduced almost to zero. With this plausible assumption, we show the coupling model can explain quantitatively the large decrease of the local segmental relaxation time found experimentally.

Journal Article↗

Self-organization of N(*) inclusions in SmC(*) free-standing films.

The behaviour of freely suspended smectic-C* ( SmC(*)) films at the bulk SmC(*)-cholesteric ( N(*)) phase transition has been investigated using polarized-reflected-light microscopy. Our experimental observations show that above the bulk SmC(*)- N(*) phase transition the N(*) order appears in different ways according to the film thickness. In thin films, the conventional layer-by-layer thinning occurs. In films of intermediate thickness N(*) inclusions nucleate inside the SmC(*) film. The distortions of the in-plane orientational order of the SmC(*) host phase induce elastic interactions between the inclusions and lead to their self-organization in chain-like structures. Both the dynamic of the chaining and the parameters driving the equilibrium distance between the inclusions in the chain are investigated. In thick films, N(*) fingers grow inside the film. The influence of the experimental conditions on the various processes is analysed.

Journal Article↗

Crystallization kinetics and crystal morphology in thin poly(ethylene oxide) films.

We present a detailed study of the kinetics of crystallization for thin films of poly(ethylene oxide) (PEO). Measurements of the growth rate have been carried out using optical-microscopy techniques on films of monodisperse PEO. Films with thicknesses from 13 nm to approximately 2 microm were crystallized isothermally at temperatures approximately 20 degrees C below the melting point. A remarkable non-monotonic slowing-down of the crystal growth is observed for films with thickness less than approximately 400 nm. The changes in the growth rate from bulk-like values is significant and corresponds to a factor of 40 decrease for the thinnest films studied. The morphologies of isothermally crystallized samples are studied using atomic-force microscopy. We find that a morphology, similar to diffusion-controlled growth (dendritic growth and densely branched growth), is observed for films with h<150 nm. In addition, changes in the morphology occur for thicknesses consistent with changes in the growth rate as a function of film thickness.

Journal Article↗

Radiotherapy planning: direct tumor location on simulation and port films using CT. Part I. Principles.

Although there have been great advances in cancer diagnosis in recent years, it remains difficult to transfer tumor location information from cross-sectional computed tomographic (CT) scans or magnetic resonance images to the simulation and verification films used in planning radiotherapy. A newly developed system uses radioopaque markers attached to the patient as reference points. These markers are identified on both CT scans and simulation films and their locations entered into the treatment planning computer. The tumor and any desired normal structures are then outlined manually on each CT section. Transparent overlays produced by the computer show the position of the reference markers and tumor outlines for any combination of gantry angles and source-film distance. Because the overlays are scaled to the simulation films, the reference points enable precise alignment of overlay and film. The tumor outline thus appears on the simulation or verification films exactly as it is "seen" by the therapy beam, making field verification straightforward and accurate, even on oblique films.

Adult↗

A vanadium/aspirin complex controlled release using a poly(beta-propiolactone) film. Effects on osteosarcoma cells.

A delivery system for vanadium was developed using poly(beta-propiolactone) (PbetaPL) films. The release kinetics of a complex of vanadium (IV) with aspirin (VOAspi) was evaluated with films prepared from polymers of different molecular weights, as well as with variable drug load. A sustained release of vanadium over 7 days was achieved. The drug release kinetics depends on contributions from two factors: (a) diffusion of the drug; and (b) erosion of the PbetaPL film. The experimental data at an early stage of release were fitted with a diffusion model, which allowed determination of the diffusion coefficient of the drug. VOAspi does not show strong interaction with the polymer, as demonstrated by the low apparent partition coefficient (approximately 10(-2)). UMR106 osteosarcoma cells were used as a model to evaluate the anticarcinogenic effects of the VOAspi released from the PbetaPPL film. VOAspi-PbetaPL film inhibited cell proliferation in a dose-response manner and induced formation of approximately half of the thiobarbituric acid reactive substances (TBARS), an index of lipid peroxidation. compared to that with free VOAspi in solution. The unloaded PbetaPL film did not generate cytotoxicity, as evaluated by cell growth and TBARS. Thus, the polymer-embedded VOAspi retained the antiproliferative effects showing lower cytotoxicity than the free drug. Results with VOAspi-PbetaPL films suggest that this delivery system may have promising biomedical and therapeutic applications.

Animals↗

Polyelectrolyte multilayer films modulate cytoskeletal organization in chondrosarcoma cells.

The aim of this study was to evaluate polyelectrolyte multilayer films as interfaces for implants. Polyelectrolyte multilayers were built up with different terminating layers by alternate deposition of oppositely charged polyelectrolytes on which chondrosarcoma (HCS-2/8) cells were grown in the presence of serum. Films formed by an increasing number of layers were investigated. The terminating layer was made of one of the following polyelectrolytes: poly-sodium-4-styrenesulfonate (PSS), poly-L-glutamic acid (PGA), poly-allylamine hydrochloride (PAH), or poly(L-lysine) (PLL). Cell viability, inflammatory response, adherence, and cytoskeletal organization were studied. Induction of interleukin-8 (IL-8) secretion was detected on PAH and PLL ending polyelectrolyte films. Early cellular adherence was enhanced with PGA, PAH, PLL, and, to a lower extent, PSS terminating layers. Adherence was independent of the number of layers constituting the films. The presence of actin filaments and vinculin focal adhesion spots was observed on PSS or PAH ending films. They were respectively partially and totally absent on PGA and PLL terminating multilayer architectures. For PLL ending films, vinculin and actin organization was clearly dependent on the number of deposited layers. The results of this study suggest that PSS ending multilayered films constitute a good interfacial micro-environment at the material surface for HCS-2/8 cells.

Actins↗

Cell-compatible properties of calcium carbonates and hydroxyapatite deposited on ultrathin poly(vinyl alcohol)-coated polyethylene films.

Poly(vinyl alcohol) (PVA) was coated onto polyethylene (PE) films by a repetitive adsorption and drying process, and then the PVA-coated PE films were alternately immersed into aqueous solutions of Ca2+ and CO3(2-) ions (alternate soaking cycles), to deposit calcium carbonate (CaCO3) onto the films. The PVA coating was essential for the CaCO3 deposition. The amount of CaCO3 deposited increased with an increasing number of cycles. Scanning electron microscopic observations and attenuated total reflection spectra revealed the presence of both calcite and aragonite as the crystal structures of CaCO3 on the film. L929 fibroblast cells adhered and proliferated on these CaCO3-deposited PE films, as well as the hydroxyapatite-coated PE films previously prepared. It was found that the PVA coating and the subsequent deposition of calcium salts on certain films facilitated cell compatibility.

Calcium Carbonate↗

Preparation of cross-linked hyaluronic acid film using 2-chloro-1-methylpyridinium iodide or water-soluble 1-ethyl-(3,3-dimethylaminopropyl)carbodiimide.

In order to obtain much slower biodegradable films, which are often required for biomedical applications, we have developed a series of studies on heterogeneous cross-linking of hyaluronic acid (HA) films by using 2-chloro-1-methylpyridinium iodide (CMPI) or 1-ethyl-(3,3-dimethylaminopropyl)carbodiimide (EDC) as cross-linking reagents. From the in vitro degradation rate, we found that EDC cross-linked HA films completely dissolved in PBS at 37 degrees C during the period of 4-6 days. However, CMPI cross-linked HA films showed only a low percentage of weight loss over 30 days. This phenomenon could be explained from the mechanism of reaction between carboxyl group of HA and EDC. The latter reacted with carboxyl group to form an unstable intermediate O-acylurea, which showed a relatively low reactivity and quickly rearranged to form a stable N-acylurea. Thus, most of the EDC-activated carboxyl groups in HA were chemically transferred into N-acylurea or left as unreactive O-acylurea, and only a few of cross-linking bonds were formed between HA. On the other hand, the intermediate obtained from the reaction between carboxyl group and CMPI showed a relatively high reactivity and reacted with the hydroxyl group of the same and/or different molecules of HA to form an inter- and intramolecular esterification. Apparently, CMPI cross-linked HA films have a much higher cross-linking density and constructed a more rigid three-dimensional network. Therefore, it produced HA films, which dramatically increased its enzymatic stability in aqueous solution of hyaluronidase. The obtained results from elemental analyses, FT-IR spectra and NMR spectra also indicate that acylurea groups were introduced into EDC-cross-linked HA films.

Biocompatible Materials↗

Synchronization of radiograph film exposure with the inspiratory pause. Effect on the appearance of bedside chest radiographs in mechanically ventilated patients.

The appearance of portable chest radiographs (CXRs) may be affected by changes in ventilation, particularly when patients are mechanically ventilated. Synchronization of the CXR with the ventilatory cycle should limit the influence of respiratory variation on the appearance of the CXR. This study evaluates the effect of synchronizing the CXR film exposure with ventilation on the appearance of the radiograph. Twenty-five patients who remained intubated postoperatively, were mechanically ventilated, and required a CXR were enrolled in this triple-blind, randomized prospective study. Each patient received one radiograph using conventional techniques and another using the interface. The sequence of the two films was randomized, and the two films were taken on the same patient within a few minutes of each other. Hence, each patient served as his own control and the position of the patient, source-film distance, intensity (Kvp), and duration of the exposure (mAs) were identical for the two films. Five board-certified radiologists were then asked to compare paired films for clarity of lines and tubes, definition of the pulmonary vasculature, visibility of the mediastinum, definition of the diaphragm, and degree of lung inflation. Radiologists were also asked to choose which films they preferred. A majority of board certified radiologists preferred CXRs taken with the interface in 21 of 25 patients (p < 0.0001). Furthermore, four of the five criteria evaluated were improved (p < 0.05) on synchronized CXRs. Synchronization of the bedside CXR with the end of inspiration ensures that they are always obtained at maximal inflation, which improves the appearance of a majority of radiographs by at least one of five criteria.

Diaphragm↗

Dielectric properties of KDP filled porous alumina nanocomposite thin films.

A new concept of a composite dielectric thin film fabrication is presented. The fabrication process consists of two stages. The first stage is anodizing a thin aluminum film to produce a porous alumina film that contains an array of nanometer sized parallel pores. The second stage is filling the pores with a saturated KDP (KH2PO4) liquid solution due to capillary forces. After drying KDP nanocrystals are formed inside the pores. This process results in a formation of a composite dielectric thin film composed of the alumina pores walls as one dielectric material and the KDP nanocrystals inside the pores as another dielectric material. The dielectric permittivity of this composite film is higher than that of the porous alumina film at all applied frequencies. The dielectric enhancement is more pronounced at low frequencies due to an interface polarization mechanism. This fabrication process enables controlling the size, composition, and microstructure of the composite dielectric film constituents and thus changing its dielectric properties over a wide range of values.

Aluminum Oxide↗

Nanoscale biomimetics: fabrication and optimization of stability of peptide-based thin films.

The method of thin film preparation known as layer-by-layer assembly is of growing interest for current and envisioned developments in bionanotechnology. Here, cysteine-containing 32mer peptides have been designed, synthesized, purified, and used to prepare polypeptide films. A range of methods-quartz crystal microbalance, Fourier transform infrared spectroscopy, circular dichroism spectroscopy, and high-performance liquid chromatography-have been used to probe the effect of ionic strength and polymer secondary structure in solution on peptide self-assembly, and on secondary structure formation and disulfide bond cross-linking in the multilayer film. The amount of designed peptide deposited per adsorption step of film fabrication increased with increasing ionic strength, as with conventional polyelectrolytes. Secondary structure content changed from random coil to beta sheet on incorporation of peptides into a film. "Peptide-inherent" cross-linking by disulfide bond formation increased film stability at acidic pH. Conditions for disulfide stabilization have been optimized. The results contribute to exploration of the physical basis of peptide self-assembly broaden the scope of applications of layer-by-layer assembly, particularly where biocompatibility and stability are key design concerns, and provide a basis for mass production of custom polypeptide thin films of high stability, even in harsh environments.

Amino Acid Sequence↗

Electrostatic layer-by-layer assembly of ultrathin films containing hexacyclen and p-sulfonatocalix[n]arene macrocycles.

Formation and characteristic properties of new layer-by-layer (LbL) assembled ultrathin films based on 1,4,7,10,13,16-hexaazacyclooctadecane (aza6) and p-sulfonatocalix[n]arenes with n=6 (calix6) and n=8 (calix8) are described. In particular, multilayered films of aza6 and polystyrenesulfonate (PSS), aza6 and calix8 or calix6, aza6 and hexacyanoferrate(II) (HCFII), calix8 and lanthanum(III), and calix8, 18-crown-6 and lanthanum(III) were investigated. The films were prepared upon alternating electrostatic adsorption of the cationic and anionic compounds from aqueous solution at charged substrates. Since the protonation of aza6 proceeds over a wide pH range, the film formation is strongly pH dependent. Linear growth of aza6/PSS films is found at pH 1.7 and 6.0, and superlinear growth at pH 0.9, 2.7, 3.7, and 5.0. The high affinity of aza6 towards inorganic ions favours the formation of LbL-assemblies of aza6 and HCFII counterions. Exposure of these films to Fe(III) leads to formation of Prussian Blue at the surface. The high affinity of p-sulfonato-calix[n]arenes towards La(III) favours the formation of LbL-assemblies of calix6 or calix8 and lanthanum. If additional 18-crown-6 is present in the La(III)-containing dipping solution, multilayered films of calix8, 18-crown-6 and La(III) are obtained.

Calixarenes↗

Tear film, contact lens, and patient-related factors associated with contact lens-related dry eye.

PURPOSE: To examine tear film, contact lens, medical, and patient-related factors associated with self-reported contact lens-related dry eye. METHODS: Four hundred fifteen contact lens wearers were recruited and enrolled in this phase of a larger cross-sectional study. A variety of tear film (e.g., interferometry, osmolality, phenol red thread, meibography, fluorescein, and lissamine green staining), contact lens (i.e., water content, refractive index, material), and patient-related (e.g., gender, sociodemographic, education, income, and medical health) factors were examined in relation to dry eye status. Univariate and multivariate logistic regression models were used to examine the relation between these tear film, contact lens, and patient-related factors associated with dry eye status. RESULTS: Of the 415 enrolled, the data from 360 were used in the analyses. The average age was 31.1 +/- 11.5 years, 245 (68%) participants were female, and 55.3% were classified as having-contact lens-related dry eye via self-report. Overall, 327 (90.8%) were hydrogel lens wearers and 33 (9.2%) were gas-permeable lens wearers. Several factors were shown to be related to dry eye status in multivariate modeling, including female gender (P = 0.007), lenses with higher nominal water content (P = 0.002), rapid prelens tear film thinning time (P = 0.008), frequent usage of over-the-counter pain medication (P = 0.02), limbal injection (P = 0.03), and increased tear film osmolality (P = 0.05). CONCLUSIONS: Contact lens-related dry eye may be explained mechanistically by increased tear film thinning times (evaporation or dewetting) resulting in increased tear film osmolality. Other contributing factors include the use of high-water-content lenses, which have traditionally been reported to be associated with less patient comfort than lower-water-content lenses, potentially due to spoilation and deposition. As found in other studies of dry eye, women are more likely to report contact lens-related dry eye than are men.

Adult↗

Estimation of the velocity of the salivary film at some different locations in the mouth.

Previously, we studied the clearance rates of KCl from agarose gels positioned at different locations in the mouth, and showed that the rates were much slower than when clearance was into a well-stirred solution. We designed the present in vitro study to test the effect on KCl clearance of the velocity of a 0.1-mm-thick film of water flowing over an agarose gel of the same diameter and composition as those used in vivo. The thickness of the salivary film overlying dental plaque has been estimated to be about 0.1 mm, and we assumed that when clearance rates in vitro matched those found in vivo, velocities of the fluid film (in vitro) and the salivary film (in vivo) must be equal. On this basis, it was calculated in the present experiments that when salivary flow was unstimulated, the velocity of the salivary film at the level of the teeth varied between about 0.8 mm/min (upper-anterior buccal region) and 8.0 mm/min (lower-anterior lingual region). When salivary flow was stimulated, this was estimated to increase the velocity of the salivary film from 2 to 40 times, depending on the location in the mouth. It is postulated that the slow movement of the salivary film when flow is unstimulated allows for accumulation of diffusants from dental plaque, which reduces the concentration gradient for diffusion from plaque and prolongs the clearance time of such metabolic products as acid.

Chemical Phenomena↗

An analysis of factors influencing diffusion from dental plaque into a moving film of saliva and the implications for caries.

Recent studies have indicated that saliva in the mouth is present as a film only about 0.1 mm thick, and that this film moves at different rates (about 0.8 to 7.6 mm/min) in different regions of the oral cavity. The clearance rates of KCl, as a model diffusant, from agarose gels at different sites in the mouth have also been found to vary markedly, and it has been proposed that these variations are related to differences in the velocity of the salivary film. A computer model has been developed for prediction of clearance half-times for substances diffusing from plaque of variable dimensions into a film of fluid 0.1 mm thick, moving at different velocities. The results show that over the range of velocities calculated to occur in the mouth, the clearance half-times are directly related to the length of plaque over which the fluid passes, and inversely related to the salivary film velocity. The predictions of the model are in good agreement with experimental results from a physical model. Tests were made of the predicted effect of salivary film velocity on the shape of the pH curve initiated by exposure of plaque to a saturated sucrose solution, followed by normal salivary clearance. With a low salivary film velocity, the fall in pH was greater and more prolonged.(ABSTRACT TRUNCATED AT 250 WORDS)

Dental Caries↗

Adhesion and function of rat liver cells adherent to silk fibroin/collagen blend films.

Collagen is often used in bioartificial livers as a biomimetic coating to promote liver cell adhesion and differentiation. Animal proteins are expensive and expose the host to risks of cross-species infection due to contamination with prions. Silk fibroin (SF) is a biocompatible protein produced by Bombyx mori silk worms and possibly an alternative to collagen. We prepared SF-collagen blend films with different SF content adherent to the bottom of standard tissue culture dishes, and characterized their surface morphology by SEM, their wettability and examined them for their capacity to support rat liver cell adhesion and metabolism. Cell metabolism was characterized by estimating the rate at which cells eliminated ammonia and synthesized urea for up to 48h of culture. SF-containing films were smooth, clear and more wettable than collagen. Cells readily adhered, formed junctions and small size aggregates on all films. As many cells adhered on SF as on collagen films. Cell adhesion to high collagen content blend films could not be reliably estimated because cells dwelt in the large cavities in the film. The effect of SF on cell metabolism differed with the investigated metabolic pathway. However, cells on SF-containing films eliminated ammonia and synthesized urea at rates generally comparable to, for urea synthesis at times higher than, that of cells on collagen. These results suggest that silk fibroin is a suitable substratum for liver cell attachment and culture, and a potential alternative to collagen as a biomimetic coating.

Animals↗

Effects of the degree of deacetylation on the physicochemical properties and Schwann cell affinity of chitosan films.

Chitosan is a potential material for the preparation of nerve repair conduits. In order to find a better chitosan for the application in peripheral nerve regeneration, the effects of the degree of deacetylation (DD) on the physicochemical properties and Schwann cell affinity of chitosan films have been evaluated. Six kinds of chitosan samples with similar molecular weight, but various DD in a range from 70.1 to 95.6% were prepared from one stock chitosan material and fabricated into films. X-ray diffraction analysis showed that there were more crystalline regions in the higher DD chitosan films. Swelling and mechanical property measurements revealed that the swelling index of chitosan films decreased and their elastic modulus and tensile strength increased with the increase in DD. The adsorption amount of fibronectin and laminin on chitosan films was measured by means of enzyme-linked immunosorbent assay (ELISA). Culture of adult rat Schwann cells on the films showed that the chitosan films with higher DD provided better substrata for Schwann cell spreading and proliferation. In conclusion, DD of chitosan plays an important role in their physicochemical properties and affinity with Schwann cells. The results suggest that chitosan with a DD higher than 90% is considered as a promising material for application in peripheral nerve regeneration.

Absorption↗

Biodegradation and in vivo biocompatibility of rosin: a natural film-forming polymer.

The specific aim of the present study was to investigate the biodegradation and biocompatibility characteristics of rosin, a natural film-forming polymer. Both in vitro as well as in vivo methods were used for assessment of the same. The in vitro degradation of rosin films was followed in pH 7.4 phosphate buffered saline at 37 degrees C and in vivo by subdermal implantation in rats for up to 90 days. Initial biocompatibility was followed on postoperative days 7, 14, 21, and 28 by histological observations of the surrounding tissues around the implanted films. Poly (DL-lactic-co-glycolic acid) (PLGA) (50:50) was used as reference material for biocompatibility. Rate and extent of degradation were followed in terms of dry film weight loss, molecular weight (MW) decline, and surface morphological changes. Although the rate of in vitro degradation was slow, rosin-free films showed complete degradation between 60 and 90 days following subdermal implantation in rats. The films degraded following different rates, in vitro and in vivo, but the mechanism followed was primarily bulk degradation. Rosin films demonstrated inflammatory reactions similar to PLGA, indicative of good biocompatibility. Good biocompatibility comparable to PLGA is demonstrated by the absence of necrosis or abscess formation in the surrounding tissues. The study provides valuable insight, which may lead to new applications of rosin in the field of drug delivery.

Animals↗