The US Food and Drug Administration investigational device exemptions and clinical investigation of cardiovascular devices: information for the investigator.

The conduct of a clinical investigation of a medical device to determine the safety and effectiveness of the device is covered by the investigational device exemptions (IDE) regulation. The purpose of IDE regulation is "to encourage, to the extent consistent with the protection of public health and safety and with ethical standards, the discovery and development of useful devices intended for human use, and to that end to maintain optimum freedom for scientific investigators in their pursuit of this purpose." Conducting a clinical investigation may require an approved IDE application. The US Food and Drug Administration encourages early interaction with the agency through the pre-IDE approval process during the development of a device or technology and during the preparation of an IDE application. This facilitates approval of the IDE application and progression into the clinical investigation. This paper reviews the terminology and applicability of the IDE regulation and the type of study that requires an IDE application to the Food and Drug Administration. The pre-IDE approval process and the development of an IDE application for a significant risk study of a cardiovascular device are discussed.

Cardiology↗

Complications of indwelling venous access devices in patients with gynecologic malignancies.

OBJECTIVE: The purpose of this study was to evaluate the complication rates associated with indwelling venous access devices in patients with gynecologic malignancies. METHODS: Following IRB approval, a computerized database identified women that had indwelling access devices placed for chemotherapy from March 1999 to June 2001. A retrospective chart review identified 116 venous access devices that were placed in 104 patients. All devices were silicone and had a closed tip design with a three-position valve. Data were collected on patient demographics, clinicopathologic features, type of venous device, and complications. The chi(2) test was used for statistical analysis. RESULTS: Of the 104 patients, 79 had ovarian cancer, 11 had uterine cancer, 10 had cervical cancer, 2 had fallopian tube cancer, and 2 had vaginal cancer. The median age was 61 years. There were a total of 116 venous devices placed: 65 external catheters (EC) and 51 subcutaneous ports (SP). Seventy-nine percent of the patients were administered low-dose coumadin (1 mg/day) for catheter clot prophylaxis. There were three operative complications in the EC group and two in the SP group (P = NS). The most common postoperative complications were infection and thrombosis. Nineteen patients in the EC group experienced a catheter-related infection versus 5 in the SP group (P = 0.025). In the EC group, there were 11 cases of site infection and 8 cases of line sepsis. In contrast, there were 3 cases of exit site infection and 2 cases of line sepsis in the SP group. Deep vein thrombosis occurred in 5 patients with EC and 3 patients with SP (P = NS). Twenty-seven patients with EC had the device removed for catheter-related complications versus 2 patients with SP (P = 0.001). Six patients inadvertently removed their EC. CONCLUSION: There is a significantly higher postoperative complication rate in gynecologic oncology patients with external catheters versus subcutaneous ports. Infection and catheter-related malfunction are more common in patients with external catheters. We recommend the use of subcutaneous ports in the majority of patients with gynecologic malignancies.

Adult↗

Dynamic laryngotracheal closure for aspiration: a preliminary report.

OBJECTIVES/HYPOTHESIS: An estimated 500,000 patients per year in the United States. are affected by stroke-related dysphagia. Approximately half experience aspiration, which can lead to pneumonia or death. Aspiration may result from many factors, including delayed transport of the bolus, faulty laryngeal elevation, and poor coordination or inappropriate timing of vocal cord closure. Interventions carried out to protect the lungs are usually irreversible, destructive to the upper airway, and rarely prevent the need for enteral tube feeding. STUDY DESIGN: We present a report of the first implantations of a new device in an FDA-approved study to restore dynamic laryngotracheal separation. Two stroke patients needing tracheostomy were selected based on chronic aspiration verified by clinical and radiologic criteria (modified barium swallow [MBS]). METHODS: The left recurrent laryngeal nerve was exposed and electrically stimulated to verify vocal fold adduction. Huntington Medical Research Institute Bipolar Helical Electrodes were then implanted around the nerve. The leads were tunneled and linked to a NeuroControl Implantable Receiver-Stimulator placed subcutaneously on the chest wall. Activation of the stimulator was performed through an external transmitter linked by induction. RESULTS: The device was successfully triggered intra- and postoperatively. Serial flexible fiberoptic endoscopies and MBS demonstrate that aspiration is systematically arrested using low levels of electrical stimulation (42 Hz, 48-100 microsec, 1 mA). DISCUSSION: This pioneering work has shown that aspiration can be controlled without airway damage for a wide population of neurologically impaired patients because it appears more physiological than standard therapies. CONCLUSION: Based on the first two patients, paced laryngotracheal separation is clinically effective in controlling aspiration.

Aged↗

Effects of decreasing inspiratory flow rate during simulated basic life support ventilation of a cardiac arrest patient on lung and stomach tidal volumes.

If the airway of a cardiac arrest patient is unprotected, basic life support with low rather than high inspiratory flow rates may reduce stomach inflation. Further, if the inspiratory flow rate is fixed such as with a resuscitator performance may improve; especially when used by less experienced rescuers. The purpose of the present study was to assess the effect of limited flow ventilation on respiratory variables, and lung and stomach volumes, when compared with a bag valve device. After institutional review board approval, and written informed consent was obtained, 20 critical care unit registered nurses volunteered to ventilate a bench model simulating a cardiac arrest patient with an unprotected airway consisting of a face mask, manikin head, training lung [with lung compliance, 50 ml/0.098 kPa (50 ml/cmH(2)O); airway resistance, 0.39 kPa/l/s (4 cmH(2)O/l/s)] oesophagus [lower oesophageal sphincter pressure, 0.49 kPa (5 cmH(2)O)] and simulated stomach. Each volunteer ventilated the model with a self-inflating bag (Ambu, Glostrup, Denmark; max. volume, 1500 ml), and a resuscitator providing limited fixed flow (Oxylator EM 100, CPR Medical devices Inc., Toronto, Canada) for 2 min; study endpoints were measured with 2 pneumotachometers. The self-inflating bag vs. resuscitator resulted in comparable mean +/- SD mask tidal volumes (945 +/- 104 vs. 921 +/- 250 ml), significantly (P < 0.05) higher peak inspiratory flow rates (111 +/- 27 vs. 45 +/- 21 l/min), and peak inspiratory pressure (1.2 +/- 0.47 vs. 78 +/- 0.07 kPa), but significantly shorter inspiratory times (1.1 +/- 0.29 vs. 1.6 +/- 0.35 s). Lung tidal volumes were comparable (337 +/- 120 vs. 309 +/- 61 ml), but stomach tidal volumes were significantly (P < 0.05) higher (200 +/- 95 vs. 140 +/- 51 ml) with the self-inflating bag. In conclusion, simulated ventilation of an unintubated cardiac arrest patient using a resuscitator resulted in decreased peak flow rates and therefore, in decreased peak airway pressures when compared with a self-inflating bag. Limited flow ventilation using the resuscitator decreased stomach inflation, although lung tidal volumes were comparable between groups.

Cardiopulmonary Resuscitation↗

Innovations in design and technology. The story of hip arthroplasty.

The current study reviews the early history of surgeon-initiated trial and error development in hip joint arthroplasty and the subsequent methodological evolution to proper criteria for hypothesis testing using bioengineers and other research scientists. The interplay and relationships to industry, universities, scientific organizations, and the Food and Drug Administration with respect to device development in hip arthroplasty are reviewed. The ethics of and responsibilities to involved parties are outlined, citing the history of many contemporary developments. Examples are provided from the evolution and introduction of unsuccessful innovations, and the problems inherent in the current methodology of the approval process from the Food and Drug Administration using the 5-10K, Investigative Device Exemption, and the Pre-Market Approval protocols. The pros and cons of randomized trials for devices are outlined with the conclusion that they are not appropriate for device introduction. The proper, rational methodology for introduction of new devices is a phased-in clinical trial process after pertinent bench testing. Finally, the ethical dilemmas created by managed care are addressed. Industry involvements of the surgeon-spokesmen are cited.

Device Approval↗

Preliminary clinical outcome and imaging criterion for endovascular prosthesis development in high-risk patients who have aortoiliac and traumatic arterial lesions.

PURPOSE: This report reviews our preliminary experience of prospective treatment of arterial lesions with endoluminal grafts in a Food and Drug Administration (FDA)-approved, investigator-sponsored Investigation Device Exemptions study. The utility and accuracy of various imaging methods, including angiography, cinefluoroscopy, computed tomography (CT), intravascular ultrasonography (IVUS), and duplex scanning, in performing the procedures was also assessed. METHODS: Thirty-one patients were evaluated; 17 patients were treated, including 11 with abdominal aortic aneurysms, one with an aortic occlusive lesion, two with iliac artery aneurysms, and three with traumatic arteriovenous fistulas. Twelve of the 14 patients who had aorta and iliac artery lesions were high-risk. The mean follow-up of patients treated was 9 months (range, 6 to 15 months). RESULTS: Aortoaortic endoluminal interposition procedures were not successful for treating abdominal aortic aneurysms early in the study (n = 3). Aortoiliac endoluminal bypass, contralateral iliac artery occlusion, and femorofemoral bypass procedures were successful in seven of eight subsequent cases (88%), with no incidence of endoleaks at either the proximal or distal fixation sites using the deployment methods described in this report. The 30-day operative mortality rate on follow-up evaluations for patients who underwent aortoiliac procedures was 14% (two of 14). Other major complications included transient renal failure in three patients that required short-term (two to eight times) dialysis, one arterial perforation and one dissection, and one prolonged intubation. No myocardial infarctions or strokes occurred. After major complications or identification of limitations in the study, the protocol was modified with the approval of the FDA to help avoid the recurrence of the same problems. There were no deaths or complications in the trauma cases. CONCLUSIONS: Contrast-enhanced CT (axial images and spiral reconstructions) was the most accurate method to determine candidacy for aortoiliac procedures and to choose the site for deployment of the devices. Angiographic scans were misleading in several patients regarding the critical determinants of patient candidacy and device deployment, particularly regarding the presence of a distal aortic neck. Cinefluoroscopy was used in all patient and was particularly useful for determining the continuity of vascular structures and the anatomy of branch arteries and for enabling precise positioning of stent devices. Determination of fixation sites and assessing dimensional information by cinefluoroscopy and angiography were limited by inaccuracies produced by image magnification, parallax, and uniplanar views. IVUS was used to determine the morphologic features of vascular structures (i.e., calcium, thrombus), to perform real-time observation of the expansion of devices, and to assure firm fixation of balloon-expanded stents before the procedures were completed. Duplex scanning was very helpful in assessing and identifying precisely the location of arteriovenous fistulas before intervention and provided assessment at follow-up intervals. Three-dimensional reconstruction imaging technologies such as spiral CT were particularly helpful for assessing the morphologic features of vascular anatomy before the intervention and at follow-up intervals, whereas 3-D IVUS provided a similar real-time perspective during the procedure.

Aged↗

Endopyelotomy with the Acucise cutting balloon device. Early clinical experience.

OBJECTIVES: To evaluate the efficacy of the Acucise balloon cutting device in the treatment of ureteropelvic junction (UPJ) stenosis. METHODS: Forty-four patients with primary (21) or secondary (23) UPJ stenosis underwent Acucise endopyelotomy between July 1992 and February 1995. RESULTS: The average operating time was 53 min and the average hospital stay was 6 +/- 4 days. The follow-up schedule included a symptom questionnaire, intravenous urography and diuretic renal scan. Of the 44 patients, 38 have been followed for a minimum of 3 months postoperatively (mean: 12 months, range: 3-39 months). Overall success was achieved in 29 (76%). The procedure was successful in 16 out of 19 cases (84%) with secondary strictures. When the technique was used for the treatment of primary UPJ strictures, the success rate was only 68% (13 out 19). The presence of a large periureteric urinoma was identified as the cause of failure in 2 cases of primary strictures. CONCLUSION: We recommend the use of the Acucise device as the first-line therapy for treatment of secondary UPJ stenosis (except in the presence of large enclosed stones). We do not approve the use of the Acucise device for treatment of primary UPJ strictures. In primary hydronephrosis, the negative role of periureteric extravasation probably explains the low success rate of 68% (as opposed to 85% for a large series of percutaneous endopyelotomies.

Adolescent↗

Regulation of medical devices in radiology: current standards and future opportunities.

Today's radiology community depends heavily on cutting-edge diagnostic and therapeutic medical devices to serve patients. These products are regulated by the U.S. Food and Drug Administration (FDA) under a system that grants marketing approval for only those indications for which the safety and effectiveness have been established. Although this complex system is the result of a societal decision to ensure device safety and effectiveness, it has the potential to delay product marketing and impede innovation. Medical device regulation recently has undergone major changes with the enactment of the Food and Drug Administration Modernization Act of 1997 (FDAMA), legislation that is intended to increase system efficiency while retaining the requirement of safety and effectiveness. However, many of the envisioned improvements cannot occur without cooperative interaction between stakeholders in the device development process, including the FDA and the clinical medicine community. The radiology field must continue to build on its strong history of productive dialogue with the FDA to transform the legislative vision of FDAMA into regulatory reality. Such action will ensure timely access to the new device technologies that are necessary for the growth of our specialty and the effective care of our patients.

Device Approval↗

Establishing an endovascular carotid stent program.

FDA approval of carotid stent and distal protection devices has transformed carotid artery stenting (CAS) from an investigational procedure to a practical application. Recent approval by the Center for Medicare Services (CMS) has ensured that CAS will be a part of everyday practice throughout the country. To establish a competitive endovascular carotid stent program, one needs to develop an effective strategy. The key to success is substance and service. A high-quality clinical program with excellent communication between the patient and referring physician is essential. You must first get access to the patient by establishing a clinical practice. As a radiologist, you have the advantage of gaining access by identifying appropriate patients through noninvasive vascular labs, CTA, and MRA. An algorithm-driven evaluation and treatment protocol with good pre- and postoperative care, along with a quality assurance program, will ensure that your carotid stent program has substance and delivers optimal service. With good planning, you will have a firm clinical foundation for treatment of carotid artery stenosis in your community. Putting all of the ingredients together will ensure a successful carotid endovascular program.

Algorithms↗

Clinical and angiographic results of transluminal extraction coronary atherectomy in saphenous vein bypass grafts.

BACKGROUND: Transluminal extraction coronary (TEC) atherectomy is a relatively new device that has recently been approved by the Food and Drug Administration. Because of its ability to aspirate clot and atheromatous material, TEC atherectomy may be useful in patients with stenoses in saphenous vein bypass grafts. METHODS AND RESULTS: TEC atherectomy was performed on 158 saphenous vein graft lesions in 146 consecutive patients with a mean age of 65 +/- 8 years (78% men). Clinical indications for atherectomy included stable angina (37%), unstable angina (54%), and postinfarction angina after recent (< 1 month) myocardial infarction (8%). Patients with acute myocardial infarction and target vessels < 2 mm in diameter were excluded. The mean age of the bypass graft was 8.3 +/- 3.0 years, and 17% were diffusely diseased and degenerated. Complex lesion morphology included total occlusion (6%), eccentricity (64%), ulceration (18%), and thrombus (28%). The TEC atherectomy cutter was successfully advanced through 144 lesions (91%), but technical failures occurred in 14 lesions (9%), and these were subsequently managed by successful balloon angioplasty. Quantitative angiography revealed an increase in lumen diameter from 0.9 +/- 0.5 mm, to 1.5 +/- 0.7 mm after TEC atherectomy, to 2.3 +/- 0.8 mm after percutaneous transluminal coronary angioplasty (PTCA) (P < .001), which corresponded to decreases in diameter stenosis from 75 +/- 14%, to 58 +/- 20% after TEC atherectomy, to 36 +/- 22% after PTCA (P < .001). Device success was achieved in 39.2% (post-TEC atherectomy decrease in diameter stenosis > or = 20%), and procedural success was achieved in 84% (final diameter stenosis < 50% in the absence of a major complication). Angiographic complications were evident in 33 lesions (20.7%) immediately after TEC atherectomy and in 8 lesions (5%) after PTCA, including distal embolization (11.9%), no-reflow (8.8%), and abrupt closure (5.0%), but no perforations. Adjunctive PTCA (and other medical therapy) successfully managed 61% of angiographic complications. Serious clinical complications included in-hospital death in 3 patients (2.0%), emergency bypass surgery in 1 patient who died (0.7%), Q wave myocardial infarction in 3 patients (2.0%), non-Q wave myocardial infarction in 4 patients (2.7%), vascular injury requiring surgical repair and/or blood transfusion in 9 patients (6.1%), and hemorrhagic cerebral infarction in 4 patients (2.7%). Using a composite clinical end point defined as in-hospital death, emergency bypass surgery, or myocardial infarction, the strongest independent correlate (P < .001) of a severe clinical complication was the development of one or more serious angiographic complications (no-reflow, distal embolization, or abrupt closure) immediately after TEC atherectomy. Complete clinical follow-up was available in 118 (92%) of 128 eligible patients at an interval of 6.0 +/- 2.5 months after discharge. Late cardiac outcome included recurrent angina treated with medical therapy (18%), repeat percutaneous intervention on the original target lesion (26%), repeat coronary artery bypass surgery (5%), Q wave myocardial infarction (4%), and late cardiac death (7%). Angiographic follow-up in 105 (80%) of 132 eligible lesions revealed a restenosis rate of 69% (defined as a diameter stenosis > 50%), including 30 lesions (29%) with total occlusion of the original lesion. CONCLUSIONS: In patients with stenoses in saphenous vein bypass grafts, TEC atherectomy is limited by the frequent need for adjunctive balloon angioplasty to achieve adequate lumen enlargement and to manage TEC atherectomy-induced complications. Although the incidence of serious clinical complications is similar to that of other percutaneous interventions in vein grafts, there is a high incidence of restenosis and late vessel occlusion. Prospective randomized studies are needed to determine the best revascularization strategy for high-risk patients with old degenerated vein

Aged↗

Wrist measurement of blood pressure: some critical remarks to oscillometry.

UNLABELLED: Oscillometric blood pressure measuring devices worn at the wrist are preferred by a growing part of hypertensive patients for self-measurement because of their compactness and ease of use. However, little is known about the accuracy of such instruments. The accuracy of such devices was evaluated by measuring the blood pressure at the end of a coronary angiography procedure in 27 subjects nearly simultaneously in the aortic arch, using a Statham P23 transducer, and at the wrist, using the blood pressure watch (BPW) by NAIS-Matsushita. Four replicate comparative measurements were performed in each subject. On average, the blood pressure measured by the BPW was found to be higher: systolic +1.2+/-(SD)10.2 mm Hg, diastolic +4.1+/-7.2 mm Hg. The correlation coefficient between the two methods was 0.85 for the systolic and 0.84 for the diastolic pressure, but 39% of the systolic and 22% of the diastolic differences were outside the range of +/-1 SD. There was no correlation between systolic differences and blood pressure or patients' variables, but multiple regression analysis revealed that the diastolic blood pressure differences were negatively correlated with the aortic diastolic pressure (r = 0.89, p<0.001), indicating that the BPW is less accurate to detect lower values. CONCLUSIONS: (1) Though the average systolic and diastolic deviations between both methods and the relative correlation coefficients suggest that the BPW is to be used carefully for monitoring blood pressure, the great variability of differences and the inability of the BPW to detect lower diastolic blood pressure calls for a mandatory validation test by an approved protocol before this new device can be recommended for general use. (2) On the basis of our results for wrist oscillometry with the BPW and data reported in the literature for upper-arm oscillometric devices, we recommend to use oscillometric devices only when they were validated properly. In particular, the oscillometric measurement should be employed with caution for epidemiological studies or for investigation of population groups (e.g., children or pregnant women) that are expected to display lower diastolic pressures.

Adult↗

Medical devices; classification of temporomandibular joint implants--FDA. Final rule.

The Food and Drug Administration (FDA) is classifying four temporomandibular joint (TMJ) implants, the total temporomandibular joint prosthesis, the glenoid fossa prosthesis, the mandibular condyle prosthesis, and the interarticular disc prosthesis (interpositional implant), into class III (premarket approval). These actions are being taken under the Federal Food, Drug, and Cosmetic Act (the act), as amended by the Medical Device Amendments of 1976 (the 1976 amendments) and the Safe Medical Devices Act of 1990 (the SMDA).

Dental Prosthesis↗

An anti-reflux prosthesis in the treatment of gastroesophageal reflux.

The Angelchik anti-reflux prosthesis, a C-shaped, silicone filled device surgically secured around the distal esophagus, received premarket approval by the Food and Drug Administration's Bureau of Medical Devices in 1979. Despite its use in over 9000 patients, there are few physiologic data documenting its effectiveness. We studied ten patients before and 3 months after prosthesis implantation with barium meal, endoscopy, esophageal biopsy, standard acid reflux testing, esophageal manometry, gastroesophageal scintigraphy, and symptom scoring. After surgery all patients were able to discontinue cimetidine and elevation of the head of the bed. Two patients had documentation of mild reflux, one of whom needed to have the prosthesis removed because of its herniation into the mediastinum. Eight patients had no reflux. There was statistically significant improvement in endoscopic, symptomatic, and biopsy grading as well as increased lower esophageal sphincter pressure after surgery. Prosthesis implantation is a promising surgical treatment of intractable esophageal reflux, but we believe additional and long-term studies are needed before its general use.

Adult↗

Functional characteristics of a new coronary perfusion balloon: comparison with the Flowtrack 40 in closed chest swine.

This study was designed to compare a new investigational coronary perfusion balloon (Wave, Scimed Life Systems Inc.) with that of an approved, widely used, current generation device (Flowtrack 40, Advanced Cardiovascular Systems). Domestic swine were anesthetized with pentobarbital and instrumented using standard percutaneous technique. Left ventricular contractile function (dP/dt) was monitored using a micromanometer while intracoronary and surface ECGs were also recorded. Eight target vessels were studied (4 LAD and 4 Cx) in random order. The perfusion balloons were kept inflated for 10 min. Complete coronary occlusion with a standard angioplasty balloon produced marked decreases in mean aortic pressure, left ventricular developed pressure, peak +dP/dt, peak -dP/dt, and significant ST segment elevation in both intracoronary and surface ECG at 30 seconds. Neither the Wave or Flowtract 40 produced any change in heart rate or mean aortic pressure. Both catheters caused a drop in left ventricular developed pressure immediately after balloon inflation. At 10 min, however, there was a small but significant decrease only with the Flowtrack 40. Similarly, peak +dP/dt was slightly depressed during Flowtrack 40 inflation at 10 min but not with the Wave catheter. Both catheters produced ST segment elevation on the surface and intracoronary electrocardiographic records. These changes were significantly greater with the Flowtrack 40 system. Thus, both the Flowtrack 40 and Wave perfusion balloons are effective in preventing ischemia during coronary occlusion in swine; however, the latter system may be more effective in this model.

Angioplasty, Balloon↗

Cataract surgery with the AlphaCor artificial cornea.

PURPOSE: To review the outcomes of AlphaCor artificial cornea (Argus Biomedical Pty Ltd.) implantation concurrent with or subsequent to cataract surgery. SETTING: Nonrandomized multicenter clinical trial. METHODS: AlphaCor devices were implanted under an approved protocol. Extracapsular cataract extraction with intraocular lens implantation was concurrently performed in 5 cases; an additional case had a displaced cataractous lens removed after severe blunt trauma subsequent to AlphaCor implantation. RESULTS: Cataract surgery was difficult because the view was restricted and residual soft lens matter was retained. There was an increased incidence of postoperative complications (eg, melt, glaucoma) in cataract cases compared with noncataract AlphaCor cases. The mean best corrected visual acuity was worse in cases with cataract than in cases without. CONCLUSIONS: The technique for cataract surgery in AlphaCor cases needs to be refined. Imaging studies performed postoperatively may help ascertain whether soft lens matter remains so additional antiinflammatory medication can be considered. Melting appears to be preventable by topical medroxyprogesterone 1% therapy.

Adult↗

Perioperative differences between endovascular repair of thoracic and abdominal aortic diseases.

BACKGROUND: With the US Food and Drug Administration approval of the TAG thoracic device, more thoracic pathologies are being treated using endovascular techniques. Although endovascular abdominal and thoracic aortic repairs have some apparent similarities, there are substantive anatomic, pathologic, and technical differences that could impact perioperative outcomes. The purpose of this study is to identify these differences. METHODS: During a 5-year period, 121 endovascular thoracic aortic repairs (TEVAR) and 450 abdominal aortic repairs (EVAR) were performed at a single institution. Preoperative, intraoperative, and early postoperative data were prospectively collected and retrospectively reviewed. Aggregate outcome measures were compared between the two cohorts, with statistical significance achieved at P < .05. RESULTS: The mean age of patients undergoing EVAR was 72.8 +/- 8.3 compared with 68.3 +/- 13.9 for TEVAR (P = .02). More women underwent TEVAR (30.6% vs 11.1%, P < .001). Aneurysms undergoing TEVAR were larger than those for EVAR (62.0 mm vs 58.3 mm, P = .01). Intraoperatively, EVAR required 26.2 minutes of fluoroscopy compared with 22.1 minutes for TEVAR (P < .001). The amount of contrast used was higher in TEVAR (133.6 mL vs 93.6 mL, P < .001). The mean procedure times were 164 minutes for EVAR and 115 minutes for TEVAR (P < .001). Iliac conduits were required in 46 patients (10.2%) undergoing EVAR, and in 24 (19.8%) undergoing TEVAR (P = .007). The 30-day or in-hospital mortality was 2.0% for EVAR and 5.0% for TEVAR (P = NS). The median length of stay was longer for TEVAR (3 days vs 2 days, P =.034). There were 54 postoperative complications in 36 TEVAR patients (29.8%), including 13 neurologic (10.7%), 8 renal (6.6%), 7 pulmonary (5.8%), 6 ischemic (5.0), and 5 (4.1%) hemorrhagic events. Among the EVAR group, 136 (30.2%) patients had postoperative complications, which included 45 ischemic (10.0%), 34 wound (7.6%), 22 renal (4.9%), 12 cardiac (2.7%), 8 pulmonary (1.8%), 5 gastrointestinal (1.1%), and 4 neurologic (0.9%) events. CONCLUSIONS: A relatively higher proportion of women underwent TEVAR than EVAR, and this was reflected in the greater need for iliac conduits to accommodate the larger delivery catheters of the thoracic devices. Intraoperative imaging techniques were also different, and TEVAR required higher contrast volumes despite shorter overall procedure times. The incidence of strokes and spinal cord ischemia was also higher during TEVAR. Despite apparent similarities of devices and techniques, EVAR and TEVAR are fundamentally different procedures with different perioperative outcomes.

Adult↗

The laryngeal mask airway: a new standard for airway evaluation in thoracic surgery.

BACKGROUND: Thoracic surgeons typically perform fiberoptic bronchoscopy (FOB) before thoracotomy, usually on the day of the operation after intubation with a single-lumen endotracheal tube (ETT) and before insertion of a double-lumen ETT. This routine requires two laryngoscopies and two intubations. The laryngeal mask airway (LMA) is an airway device developed in England and approved by the Food and Drug Administration in 1991 for clinical use in the United States. It requires neither mask ventilation nor laryngoscopy and allows FOB visualization of the epiglottis, larynx, and entire trachea. We assessed the LMA as an alternative to a single-lumen ETT for FOB before thoracotomy. METHODS: Through prospective assessment, 50 patients underwent FOB after insertion of an LMA before thoracotomy. Pulse rate, blood pressure, ease of insertion of the LMA, quality of FOB, and complications of LMA insertion were assessed. RESULTS: During LMA insertion, blood pressure and pulse rate increased less than 5% from baseline in all patients. The LMA was inserted successfully in all patients within 10 seconds. No complications occurred as a result of LMA insertion. CONCLUSIONS: Insertion of the LMA causes minimal hemodynamic response. From the time of induction of general anesthesia, insertion of the LMA is quick, simple, and safe and eliminates the need for endotracheal intubation with a single-lumen ETT before double-lumen tube insertion. The LMA, in contrast to the ETT, allows a complete survey of the larynx and trachea. The LMA is autoclavable, reusable, and cost effective. Therefore, in patients who require FOB immediately before thoracotomy, LMA use should be the standard for airway evaluation.

Bronchoscopy↗

Total implantation of the Implex TICA hearing amplifier implant for high frequency sensorineural hearing loss: the Tübingen University experience.

Hearing devices may be classified as sound-producing hearing aids, electrically stimulating devices, and vibratory hearing aids. Because patients may lose physiologic cochlear amplification, hearing devices for the treatment of sensorineural hearing loss are used as signal amplifiers. The totally implantable communication assistance (TICA) device is a European-approved totally implantable vibratory amplifier implant. It picks up the sound signal transcutaneously from the external auditory canal near the eardrum, amplifies the signal, and transduces the signal into microvibrations that are delivered to the ossicular chain.

Acoustics↗