Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CASTS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89Linked to original sources

Intracranial cavity volume can be accurately estimated from the weights of intracranial contents: confirmation by the dental plaster casting method.

Intracranial cavity volume is used to evaluate brain size relative to the intracranial space. This volume can theoretically be obtained from the weights and densities of the brain and surrounding cerebrospinal fluid (weight method). However, the accuracy of this method has not been examined. In this study, we examined the reliability of the weight method, by comparing the intracranial cavity volumes of 41 post-mortem cases obtained by the weight method (ICVw) with those obtained by a dental plaster casting method (ICVcast) which was shown to be unbiased. The ICVw was not significantly different from the ICV cast (P=0.49, paired t-test), and the standard error of difference was 18 ml (1.3% of ICVcast). These results show that the weight method is reliable, and applicable to routine autopsies.

Aged↗

Surface roughness of gold alloy castings.

The present investigation has shown that the surface of gold alloys cast in both a new and probably improved investment and in two commercial gypsum-bonded investments fulfills all conventional clinical requirements as regards retention and precision of the cemented restorations and easy polishability. With a view to retention the sometimes slightly rougher surfaces of castings in the new investment are advantageous.

Dental Casting Investment↗

Effect of thickness of peridental restorations on the casting precision.

The present study has shown that the precision of peridental gold alloy castings depends both on the specific properties of the investment used and on the thickness of the pattern. In all cases the inside diameter of the castings decreased with increasing thickness. The most accurate results were obtained with an experimental investment characterized by a setting expansion of 0.05%, a thermal expansion high enough to compensate for the alloy contraction during cooling from solidus to room temperature, and a compressive strength of only 27 kg/cm2 at 670 degrees C.

Dental Casting Investment↗

The effect of casting ring liners on the potential expansion of a gypsum-bonded investment.

Cellulose paper (used wet) and ceramic paper (used dry) are replacing asbestos paper as cushioning ring liners in dental casting. A study was made of the effects of all three of these materials on the setting and subsequent thermal expansion of a gypsum-bonded cristobalite casting investment (W/P = 0.40). Thermal expansion measurements were made on the same specimens that were produced during the setting expansion tests. Control specimens setting against a smooth dry surface showed a total expansion of 1.7%. Specimens setting against dry ceramic liners had similar total expansions, in the range 1.6 to 1.7%. Specimens setting against either of the wet lining materials showed an increased total expansion (in the range 2.2 to 2.3%), by virtue mainly of a large increase in setting expansion. In order for reproducible setting expansion results to be obtained with wet liners, it was necessary to control the amount of absorbed water carefully. Dry asbestos and dry cellulose liners gave higher expansions than pre-wetted ones, since they abstracted water from the mix, reducing its effective W/P ratio (giving a thicker mix), and then functioned as wet liners. These results suggest that, at least as far as potential investment expansion is concerned, wet cellulose liners have an effect similar to that of the traditional wet asbestos liners. Dry ceramic liners give a much lower investment expansion, and when these liners are used, an investment with an increased measured expansion could be an advantage.

Asbestos↗

Labor reduction for mold preparation of a commercial titanium cast denture system using a heat-shock method.

The purpose of this study was to investigate the application of a heat-shock method to fabricate titanium cast plates. Duplications of a maxillary model were prepared using DM under different firing schedules. Molds with patterns on the duplications were made by an outer investment (D), followed by heat shock at 850 degrees C. Duplications heat shocked at 850 degrees C after 30 min from mixing exploded within a few minutes. This explosion was successfully avoided by a drying procedure prior to the heat-shock. The molds were available for the heat shock at 850 degrees C when the duplicate models were prepared by firing either using the conventional method and the heat shock above method described. Therefore, we could reduce the preparation time from about 16 hr with the conventional method to about 10 hr at the longest with the heat-shock method. These results suggested that the heat-shock method was labor-saving for fabricating titanium cast denture plates when controlling preliminary conditions prior to use.

Dental Casting Investment↗

Fit and dimensional changes of cast CP titanium crowns fabricated using sintered molds.

The present study was undertaken to evaluate the clinical applicability of cast CP titanium crowns fabricated with sintered molds. To this end, the dimensional changes and accuracy of fit of cast CP titanium crowns, manufactured under varying mold firing temperatures, were examined. Molds were fired at 7 temperatures. The outer height of the crown and outer width of the occlusal surface decreased under all sets of firing conditions. The outer width of the cervical part tended to increase at firing temperatures of 1,200, 1,300 and 1,400 degrees C. The inner widths of the occlusal surface and cervical part tended to increase under all sets of firing conditions. In the analysis of the fit of crowns, floating (gained latitude) was observed under all sets of conditions. However, the amount of floating was significantly smaller when the firing temperature was 1,200, 1,300 or 1,400 degrees C than when it was 800, 900, 1,000 or 1,100 degrees C.

Analysis of Variance↗

Grindability of dental cast Ti-Ag and Ti-Cu alloys.

Experimental Ti-Ag alloys (5, 10, and 20 mass% Ag) and Ti-Cu alloys (2, 5, and 10 mass% Cu) were cast into magnesia molds using a dental casting machine, and their grindability was investigated. At the lowest grinding speed (500 m min(-1)), there were no statistical differences among the grindability values of the titanium and titanium alloys. The grindability of the alloys increased as the grinding speed increased. At the highest grinding speed (1500 m x min(-1)), the grindability of the 20% Ag, 5% Cu, and 10% Cu alloys was significantly higher than that of titanium. It was found that alloying with silver or copper improved the grindability of titanium, particularly at a high speed. It appeared that the decrease in elongation caused by the precipitation of small amounts of intermetallic compounds primarily contributed to the favorable grindability of the experimental alloys.

Copper↗

[Study on casting precision of plat castable ceramic crowns].

The plat castable ceramic crown was made with investment material prepared in our college with our own casting technique by a Chinese-made casting machine. The accuracy and fitness of the crown were studied and appraised. Results show that the margin of fitness is 46 microns and that the cement film thickness of the dies in the spacer material group is 65.13 microns. Hence the results are satisfactory. The Plat castable ceramic crown might be used in clinical dentistry.

Crowns↗

[Application of gypsum-bonded investment containing niobium carbide on casting of alloy for metal-ceramic restoration].

Experimental gypsum-bonded investments containing 0.5-5.0 wt% NbC were prepared by mechanical mixing of each powder. Setting and thermal expansion measurement, compressive strength and casting accuracy for Ni-Cr alloy for metal-ceramic restoration were investigated. Analysis of NbC during heating was carried out by X-ray diffraction, TG-DTA and SEM. NbC was oxidized to Nb2O5 with a volume change between 300-600 degrees C, as in the following equation: 2NbC + 4 1/2O2----Nb2O5 + 2CO2 The theoretical volume of 1/2Nb2O5 calculated from the lattice constants according to JCPDS file was approximately 4 times larger than that of NbC. The experimental investments of 70 wt% cristobalite and 30 wt% gypsum containing 2.0, 3.0 and 5.0 wt% NbC showed large thermal expansion of 7.0, 10.0 and 13.0% respectively. The investment containing 2.0 wt% NbC showed nearly the same casting accuracy for Ni-Cr alloys for metal-ceramic restoration as the commercial phosphate-bonded investment.

Calcium Sulfate↗

[Evaluation of cervical gaps in complete metal crowns cast in alternative silver-tin alloys. Relationship to investing techniques].

The purpose of this study was to evaluate cervical mistifing of casting full metal crowns according to investment techniques using commercial available alloys made from silver stannum. Fifteen metal full crowns were obtained through stainless steel die with full crowns preparation, included into three groups as follows: conventional technique, vacuum technique and pressure technique. Readings of cervical disagreement were made through a comparing microscope increased 45 x and each crown was measured in 4 different regions (vestibular, lingual mesial and distal). This way it was verified which of the techniques proposed would balance the casting shrinkage for the silver-stannum alloy used. From the results obtained we conclude that the best cercical adaptation was the one got through pressure technique.

Crowns↗

[The influence of different conditions of refractory mold preparation on precision of casting of Co, Cr, Mo alloys].

The following hypothesis was made: different conditions of preparation and heat treatment of refractory mold change its physical and mechanical characteristics which is of great importance for the precision of casting of Co, Cr, Mo alloys. To prove this hypothesis measurements of setting time, setting and thermal expansion and transverse strength were performed regarding the relationship between the powder and the liquid of investment. The research was carried out on "Politerm C", "Rema Exakt" and "Widerit" investments. The obtained results proved the hypothesis that different conditions during the preparation of refractory mold had a certain influence on the quality of casting of Co, Cr, Mo alloys. The domestic investment was approximately of the same quality as the tested investments of foreign origin.

Chromium Alloys↗

Influence of mold materials and heat treatment on tensile properties of Ni-Ti alloy castings.

The influence of mold materials and heat treatment on the tensile properties and the transformation temperatures of Ni-Ti alloy castings was investigated by tensile test and differential scanning calorimetry (DSC) in order to apply the special properties of the alloy to dental field. The compositions of the two alloys examined were 49.0 and 49.2 at % Ti. A silica investment and a magnesia investment were used as the mold materials. Heat treatment at 440 degrees C for 1.8 ks was performed. Apparent proof strength decreased in both compositions, and residual strain increased in Ni-49.2Ti by the heat treatment. Elongation increased in Ni-49.0Ti with use of the magnesia mold or by the heat treatment. The transformation temperatures of Ni-49.2Ti increased with use of the magnesia mold. The change by the heat treatment suggested a structural change. The development of a suitable method for the casting of the alloy is expected to bring about the development of new devices and therapy in dentistry.

Calorimetry, Differential Scanning↗

Venous thromboembolism in patients undergoing laparoscopic and arthroscopic surgery and in leg casts.

The risk of venous thrombosis and need for prophylaxis in patients having undergone minimally invasive procedures and in patients immobilized in a leg plaster are poorly defined. We performed a literature search to evaluate the risk of developing venous thromboembolism after 2 minimally invasive procedures, laparoscopic surgery and arthroscopy, and in patients with lower limb plaster casts. Despite problems of "contamination" because some surgeons use prophylaxis in some of these patients, we were able to determine that (1) laparoscopic cholecystectomy can be considered a low-risk procedure and therefore routine use of prophylaxis is probably not justified; (2) patients undergoing arthroscopic knee surgery are at low to moderate risk and thus prophylaxis is optional; and (3) patients with plaster cast immobilization because of trauma have a moderate risk of thrombosis and should receive prophylaxis.

Arthroscopy↗

Microvasculature of the bovine claw demonstrated by improved micro-corrosion-casting technique.

A new and improved technique for microvascular corrosion casting was developed and verified by examination of corrosion casts of 90 bovine limbs. The described technique renders a complete filling of the vasculature of the claw even in regions that hitherto proved to be difficult regarding completeness of filling such as the dorsal area of the claw. This is demonstrated by an exemplary examination of all regions of the claw. The advantages and disadvantages of the new method are discussed.

Animals↗

SEM corrosion-casts study of the microcirculation of the flat bones in the rat.

BACKGROUND: Little is known about the organization of microcirculation in flat bones in comparison with long bones. This study, therefore, helps us to determine the design of this vascular system in flat bones in relation to their structure and function. METHODS: The organization of microvasculature in parietal, scapula, and ileum bones of 15 young sexually mature rats, aged 6-7 weeks, was studied by light and scanning electron microscopy (SEM) from vascular corrosion cast (vcc), a resin-cast obtained material. RESULTS: Our observations show that the pattern of the microcirculation in flat bones is different in the thick and thin parts of such bones. Where the bone is thinner than 0.4 mm, only periosteal and dural network exist. Larger vessels which do not form a real network connect the two tables of the bones in these regions. In thicker areas, the organization of the microvasculature is similar to that in long bones, with distinct periosteal, cortical and bone marrow networks. Moreover, in different bones, outer networks show slightly different characteristics according to the different adjacent structures (dura mater, muscles etc.). Different types of vessels were recognized by comparing their different diameter, course and endothelial imprints. CONCLUSIONS: The microvascular patterns of the flat bones are strongly influenced by the bone thickness. The different microvascular systems can interact both with the bone modelling and remodeling and with the variable metabolic needs, modifying the microvascular pattern and the blood flow. This is even more important in view of the reciprocal influence of the different networks within the same bone.

Animals↗

Microvascular architecture of the human urinary bladder wall: a corrosion casting study.

The vascular system of the urinary bladder wall effectively performs its function in spite of considerable spatial changes due to the filling/voiding cycle. However, only a few studies have dealt with the microvascular architecture of the bladder wall and only two, using old-fashioned techniques, were devoted to the human bladder. This study presents the microvasculature of the human bladder wall visualized by scanning electron microscopy of vascular corrosion casts. Postoperative bladder specimens obtained from patients with advanced bladder tumors were filled with small amount (80 ml) of saline and perfused via at least four largest arteries with anticoagulant-containing saline followed by paraformaldehyde/glutaraldehyde fixative and Mercox resin. After polymerization of the resin, the vascular casts were macerated with potassium hydroxide, cleaned with formic acid and water and freeze dried. Only regions of the bladder wall distant to the tumor were examined in light and scanning electron microscopes. The almost empty state of the bladder was manifested by extensive folding of the mucosa and tortuosity of almost all vessels other than capillaries. The branches of main arteries and veins formed an adventitial/serosal plexus which directly supplied/drained the capillary network of the muscularis and sent long perpendicular vessels to the mucosal plexus. These vessels had straight or coiled course depending on whether they terminated at the top or at the base of the mucosal folds. The rich mucosal plexus followed the folds parallel to their surface and gave off short, straight, mostly perpendicular twigs communicating with the subepithelial capillary network. Apart from very few vascular interconnections between the mucosal plexus and the muscularis, the submucosa was generally avascular. The subepithelial capillary network showed extreme density and uneven contours of the capillaries, only in less folded areas of trigone and urethral orifice the network was looser and capillaries thinner. The capillary system of the muscularis was poorly developed. Due to its architecture, tortuosity, and coiling/uncoiling capabilities, the microvasculature of the human urinary bladder wall seems to efficiently accommodate changes associated with cyclic contraction and stretching. Disturbances in blood flow induced by overdistension of the bladder reported in several studies may be due to pressure of the urine affecting the patency of the vessels rather than to the spatial insufficiency of the vascular system.

Adult↗

Scanning electron microscopy observation of vascularization around hydroxyapatite using vascular corrosion casts.

An intimate relationship exists between the regenerative response of the vascular and osseous elements following hydroxyapatite (HA) implantation. In order to fully comprehend the 3-dimensional vascular architecture around HA, dense HA particles were implanted into the tibiae of dogs. Following healing periods of 2 weeks, 1 month, and 3 months, the tibiae were prepared by the corrosion cast technique. Under scanning electron microscopy (SEM) observation, the characteristic vascular morphology of the HA-implanted cavity was successfully demonstrated. The initial vascularization began in the form of loose sinusoidal capillaries. Many sinusoids formed a complex network by anastomosing with each other. The newly formed vessels extended centripetally from the peripheral cavity wall and from the periosteal surface. Under greater magnification, the tapered vascular sprouting was shown to project into the space that was previously occupied by an HA particle. The presence of vascular sprouting is clearly an important indicator of angiogenesis. Increasing vascularization was demonstrated with time. The presence of vessels in the Haversian's canal indicated the more established vascularization. Almost full vascularization of the HA-implanted cavity was seen 3 months after implantation. The vascular organizational layout of the cavity was also clearly shown in the fractured transverse-sectioned sample. In the control without HA implantation, the central region of the cavity showed a hollow pattern in the initial stage. The vascularization looked like it was collapsing and not fully filling the cavity. However, remarkable differences of the final vascular pattern could not be found between the study and control group after 3-month implantation. The study provides the time-lapsed 3-dimensional vascular changes of the HA-implanted cavity, as well as the value of the corrosion cast technique in examining the bony circulation.

Animals↗

Thin sol-gel-derived silica coatings on dental pure titanium casting.

The sol-gel dipping process, in which liquid silicon alkoxide is transformed into a solid silicon-oxygen network, can produce a thin film coating of silica (SiO(2)). The features of this method are high homogeneity and purity of the thin SiO(2) film and a low sinter temperature, which are important in the preparation of coating films that can protect metallic ion release from the metal substrate and prevent attachment of dental plaque. We evaluated the surface properties of dental pure titanium casting coated with a thin SiO(2) or SiO(2)/F-hybrid film by the sol-gel dipping process. The metal specimens were pretreated by dipping in isopropylalcohol solution containing 10 wt% 3-aminopropyl trimethoxysilane and treated by dipping in the silica precursor solution for 5 min, withdrawal at a speed of 2 mm/min, air-drying for 20 min at room temperature, heating at 120 degrees C for 20 min, and then storing at room temperature. Both SiO(2) and SiO(2)/F films bonded strongly (above 55 MPa) to pure titanium substrate by a tensile test. SiO(2(-)) and SiO(2)/F-coated specimens immersed in 1 wt% of lactic acid solution for two weeks showed significantly less release of titanium ions (30. 5 ppb/cm(2) and 9.5 ppb/cm(2), respectively) from the substrate than noncoated specimens (235.2 ppb/cm(2)). Hydrophobilization of SiO(2(-)) and SiO(2)/F-coated surfaces resulted in significant increases of contact angle of water (81.6 degrees and 105.7 degrees, respectively) compared with noncoated metal specimens (62.1 degrees ). The formation of both thin SiO(2) and SiO(2)/F-hybrid films by the sol-gel dipping process on the surface of dental pure titanium casting may be useful clinically in enhancing the bond strength of dental resin cements to titanium, preventing titanium ions release from the substrate, and reducing the accumulation of dental plaque attaching to intraoral dental restorations.

Adhesiveness↗