Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Automatism”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89Linked to original sources

Automatic versus intentional uses of memory: aging, attention, and control.

In 2 experiments, the authors used a process dissociation procedure (Jacoby, 1991) to separately examine the effects of aging on automatic and consciously controlled memory processes. In Experiment 1, a group of young adults in either a full-attention or divided-attention condition were compared with a group of elderly adults on a fame judgment task. Both age and divided attention had a detrimental effect on consciously controlled memory processing but left automatic processing intact. In Experiment 2, the same age-related pattern was found using a more demanding forced-choice recognition paradigm.

Adolescent↗

Dual-task assessment of age differences in automatic process development.

The present experiment assessed dual-task performance in 20 young (mean age 21) and 20 old (mean age 72) adults. Ss first received extensive single-task practice on consistent and varied search tasks. Next, they received dual-task practice in 2 conditions: (a) varied visual search plus varied memory search and (b) consistent visual search plus varied memory search. In the varied-varied condition, young and old adults showed similar dual-task decrements. These results, along with the current data in the literature, suggest that practice may play an important role in determining age-related dual-task differences (or lack thereof). In the consistent-varied condition, young adults attained single-task performance levels, because they had automatized the consistent task. Old adults were unable to match their single-task performance levels, indicating that they were unable to automatize the consistent task.

Adolescent↗

Variability in the likelihood of automatic attitude activation: data reanalysis and commentary on Bargh, Chaiken, Govender, and Pratto (1992)

This commentary addresses J. A. Bargh, S. Chaiken, R. Govender, and F. Pratto's (1992) conclusion that automatic attitude activation depends not on the idiosyncratic strength of the association in memory between an attitude object and an individual's evaluation of the object but on normative considerations constant across individuals. A variety of difficulties with the bases for this conclusion are discussed. Moreover, additional analyses of the J.A. Bargh et al. data reveal the superiority of an idiosyncratic measure of associative strength (a given individual's latency of response to an attitudinal inquiry) in predicting automatic attitude activation over the various normative measures (latency, extremity, ambivalence, polarization, and consensus or consistency) that were examined. These results support the theoretical premise that attitude activation varies as a function of position along an idiosyncratically defined attitude-nonattitude continuum.

Association↗

Dissociating the effects of automatic activation and explicit expectancy on reaction times in a simple associative learning task.

After repeated associations between two events, E1 and E2, responses to E2 can be facilitated either because participants consciously expect E2 to occur after E1 or because E1 automatically activates the response to E2, or because of both. In this article, the authors report on 4 experiments designed to pit the influence of these 2 factors against each other. The authors found that the fastest responses to a target in a reaction time paradigm occurred when automatic activation was highest and conscious expectancy lowest. These results, when considered together with previous findings indicating that, under most conditions, the relation between expectancy and reaction times is in the opposite direction, are indicative of a reversed association-an interaction pattern that J. C. Dunn and K. Kirsner (1988) demonstrated to be the only one that unambiguously points to the involvement of independent processes.

Adolescent↗

Effects of alcohol on controlled and automatic memory processes.

The authors used the process-dissociation procedure (L. L. Jacoby, 1998) to examine the effects of alcohol on controlled and automatic influences on memory performance. Participants studied 1 of 2 word lists and subsequently were cued with word stems to recall the words from both lists. Fifty-four men were administered either a moderate dose of alcohol (0.82 g/kg) or placebo prior to studying the word list. Results indicated that alcohol decreased estimates of controlled contributions to performance on the task. In contrast, alcohol did not appear to affect automatic influences on this task. Integrated with recent findings using a different cognitive task, these data suggest that alcohol impairs performance on implicit, conceptually driven tasks but not on implicit, perceptually driven tasks.

Adult↗

Automatic design and manufacture of robotic lifeforms.

Biological life is in control of its own means of reproduction, which generally involves complex, autocatalysing chemical reactions. But this autonomy of design and manufacture has not yet been realized artificially. Robots are still laboriously designed and constructed by teams of human engineers, usually at considerable expense. Few robots are available because these costs must be absorbed through mass production, which is justified only for toys, weapons and industrial systems such as automatic teller machines. Here we report the results of a combined computational and experimental approach in which simple electromechanical systems are evolved through simulations from basic building blocks (bars, actuators and artificial neurons); the 'fittest' machines (defined by their locomotive ability) are then fabricated robotically using rapid manufacturing technology. We thus achieve autonomy of design and construction using evolution in a 'limited universe' physical simulation coupled to automatic fabrication.

Computer Simulation↗

Automatic gain control in the echolocation system of dolphins.

In bats and technological sonars, the gain of the receiver is progressively increased with time after the transmission of a signal to compensate for acoustic propagation loss. The current understanding of dolphin echolocation indicates that automatic gain control is not a part of their sonar system. In order to test this understanding, we have performed field measurements of free-ranging echolocating dolphins. Here we show that dolphins do possess an automatic gain control mechanism, but that it is implemented in the transmission phase rather than the receiving phase of a sonar cycle. We find that the amplitude of the dolphins' echolocation signals are highly range dependent; this amplitude increases with increasing target range, R, in a 20 log(R) fashion to compensate for propagation loss. If the echolocation target is a fish school with many sound scatterers, the echoes from the school will remain nearly constant with range as the dolphin closes in on it. This characteristic has the same effect as time-varying gain in bats and technological sonar when considered from a sonar system perspective.

Acoustics↗

Therapeutic concordance of two portable monitors and two routine automatic oral anticoagulant monitoring systems using as reference the manual prothrombin time technique.

Two models of capillary blood prothrombin time (PT) monitoring systems were evaluated for analytical performance and then compared with two routine PT systems using the reference manual technique and a high-sensitivity thromboplastin. Two sets of 60 and 80 plasmas were analyzed from anticoagulated patients stabilized over 3 months in an INR range 2-3.5 for therapy. Capillary PT determination was performed in two portable monitors, CoaguChek S and CoaguChek PT (Roche Diagnostics), and plasma automatic methods were Neoplastine/STA (Diagnostics Stago) and PT-FibrinogenHsPlus/ACL7000 (Instrumental Laboratories). Thromboplastin Bilbao (TBi), an in-house high-sensitivity rabbit thromboplastin (ISI=1.08), recommended as the reference reagent by an External Spanish Oral Anticoagulant Quality Assessment, was used in the PT manual technique. The two monitors' coefficients of correlation with the reference system were 0.74 for CoaguChek S and 0.81 for CoaguChek PT. The automatic routine systems showed a correlation of 0.92 (Neoplastine/STA) and 0.91 (PT-FbHsPlus/ACL7000). Clinical agreement expressed as the percentage of simple correlation ranged between 75.0% (CoaguChek S) and 88.9% (Neoplastine/STA). The systems having the best kappa index with the manual technique were CoaguChek PT (71.9%) and the Neoplastine/STA system (73%). The routine PT management systems exhibited better correlation and percentage of concordance when using the TBi/manual technique than did the portable monitors, which moreover performed unequally in this regard.

Anticoagulants↗

Automatization of correct production at two levels of articulatory acquisition.

This study investigated the assumption that children who are in the process of acquiring correct production of a misarticulated phoneme are also in the process of developing automatization of correct production. Using the McDonald Deep Test of Articulation, children's articulation was tested under two conditions: Condition 1 without masking and Condition 2 with 85 dB SLP of competing speech masking. Children were classified into one of two levels of articulatory acquisition according to their performance during Condition 1. Children scoring below 80% correct were classsified as demonstrating low acquisition. Children scoring above 80% correct were classified as demonstrating high acquisition. Only children with /s/ or /r/ misarticulations were studied. Results indicated that the correct articulation of children demonstrating low acquisition was significantly more affected by the auditory masking than the correct articulation of those children demonstrating higher levels of acquisition. There was no significant difference in the performance of the children with the /s/ or /r/ misarticulations. The results support the concept that articulatory acquisition and automatization of correct articulation relate in a predictable manner.

Age Factors↗

Automatic phonetogram recording supplemented with acoustical voice-quality parameters.

A new method for automatic voice-quality registration is presented. The method is based on a technique called phonetography, which is the registration of the dynamic range of a voice as a function of fundamental frequency. In the new phonetogram-recording method fundamental frequency (Fo) and sound-pressure level (SPL) are automatically measured and represented in an XY-diagram. Three additional acoustical voice-quality parameters are measured simultaneously with Fo and SPL: (a) jitter in the Fo as a measure for roughness, (b) the SPL difference between the 0-1.5 kHz and the 1.5-5 kHz bands as a measure for sharpness, and (c) the vocal-noise level above 5 kHz as a measure for breathiness. With this method, the voice-quality parameter values, which may change substantially as a function of Fo and SPL, are pinned to a reference position in the patient's total vocal range. Seen as a reference tool, the phonetogram opens the possibility for a more meaningful comparison of voice-quality data. Some examples, demonstrating the dependence of the chosen quality parameters on Fo and SPL are given.

Humans↗

Automatic and effortful processing of emotional intonation after right or left hemisphere brain damage.

This study assessed the effects of unilateral right (RHD) or left hemisphere brain damage (LHD) on the knowledge and processing of emotional information imparted by vocal intonation. Semantically neutral statements that conveyed a mood through prosody were used as targets in a mood priming task. These targets were preceded by story primes. The events described in the primes were either congruent with the mood conveyed by the intonation of a target phrase, incongruent with target mood, or emotionally neutral. Prime-target pairs were presented in two attention conditions designed to favor either relatively automatic or effortful mental processing. Response time (RT) data were recorded for accurate judgments of target moods. In the automatic condition, there were no qualitative differences between RHD, LHD, or normally aging control subjects. In the effortful condition, RTs for each group were similarly improved by congruent primes (relative to neutral primes), but RHD subjects were disproportionately slower when targets were preceded by incongruent primes. Results indicate that brain-damaged adults retain knowledge of emotional meanings, and use that knowledge to facilitate effective interpretations in some circumstances. Demands for emotional inference revision were not exclusively responsible for RHD adults' poor performance with incongruent primes, as they successfully revised initial predictions in other conditions. Rather, these subjects' difficulties arose when increased processing demands converged with decreased availability of mental resources. These findings are integrated with those from a related study of lexical metaphor, and are interpreted within a cognitive resource framework.

Aged↗

Development of a two-stage procedure for the automatic recognition of dysfluencies in the speech of children who stutter: I. Psychometric procedures appropriate for selection of training material for lexical dysfluency classifiers.

This program of work is intended to develop automatic recognition procedures to locate and assess stuttered dysfluencies. This and the following article together, develop and test recognizers for repetitions and prolongations. The automatic recognizers classify the speech in two stages: In the first, the speech is segmented, and, in the second, the segments are categorized. The units that are segmented are words. Here assessments by human judges on the speech of 12 children who stutter are described using a corresponding procedure. The accuracy of word boundary placement across judges, categorization of the words as fluent, repetition or prolongation, and duration of the different fluency categories are reported. These measures allow reliable instances of repetitions and prolongations to be selected for training and assessing the recognizers in the subsequent paper.

Adolescent↗

Laser surgery in a patient with Romano-Ward (long QT) syndrome and an automatic implantable cardioverter defibrillator.

A 48-year-old woman with Romano-Ward syndrome (a hereditary long QT syndrome), asthma and an automatic implantable cardioverter defibrillator presented for laser surgery for debulking of a massive nasopharyngeal tumour prior to radiotherapy. Automatic implantable cardioverter defibrillators have only relatively recently been used to treat patients with the long QT syndrome and are indicated for the high-risk individual when conventional treatment has failed or when beta-blockers are contraindicated. If surgery requires the use of surgical diathermy, a cardiac technician must be present to deactivate the defibrillator and external pacing electrodes are sited on the chest until the defibrillator can be reactivated. Radiotherapy requires both deactivation and shielding of the device.

Defibrillators, Implantable↗

Retrospective analysis of the frequency and recognition of adverse drug reactions by means of automatically recorded laboratory signals.

AIMS: To estimate the frequency of adverse drug reactions (ADRs) identified through the use of automatic signals generated from laboratory data (ALS) in hospitalised patients. To determine the frequency of spontaneous recognition of these ADRs by the attending physicians and to assess the potential value of ALS for detection of ADRs. METHODS: Laboratory results of patients hospitalised in a nine bed medical ward were automatically recorded over a period of 17 months. Values exceeding defined boundaries were used as ALS. Charts of every third patient were analysed retrospectively with regard to adverse drug related reactions and causality was evaluated as well as whether the ADR had been recognised during the period of hospitalisation. RESULTS: The charts and ALS of 98 patients were analysed. In 18 cases a drug-related adverse reaction was probable. Awareness to the reaction by the treating physicians was evident in 6 out of these 18 ADRs. Approximately 80% of the ADRs were considered predictable. Three ADRs were regarded as serious. CONCLUSIONS: Adverse drug reactions are common and often preventable. Only one third of ADRs which could have been detected through ALS were recognised by the attending physicians. An increased doctor's awareness of the frequency of drug related abnormal laboratory results by means of ALS is likely to increase the recognition rate of ADRs and might help to prevent them.

Adult↗

Automatic computerized analysis of heart rate variability with digital filtering of ectopic beats.

Analysis of heart rate variability (HRV) has been used in studies of autonomic function and risk assessment in different patient groups such as in patients with diabetes mellitus, after myocardial infarction (MI) and other cardiovascular disease. Ectopic beats can, however, interfere with HRV analysis and give erroneous results. We have therefore studied the impact of ectopic beats on HRV analysis and the ability of a filter algorithm to correct this. Power spectral analysis of synthetic data with an increasing proportion of ectopic beats and 24-h Holter recordings from 98 healthy subjects and 93 post MI patients was done with and without digital filtering and interpolation of errors in the data stream. The analysis of HRV was seriously hampered by less than 1% of ectopic beats. A filter algorithm based on detection and linear interpolation of ectopic beats and other noise in the data stream corrected effectively for this in the synthetic data employed. In the healthy subjects and the post MI patients, filtering markedly reduced the extra variability related to non-normal beats. The software could automatically analyse over one hundred 24-h files in one batch. HRV analysis should include filtering for ectopic beats even with a small number of such beats. It is possible to make a fast analysis automatically even in huge clinical series, which makes it possible to use the method both clinically and in epidemiological studies.

Adult↗

Examination of accuracy of sleep stages by means of an automatic sleep analysis system 'Sleep Ukiha'.

We examined the differences between the results of an automatic sleep analysis system and inspection decision. Subjects were 10 males (average age 21.6 years). One section consists of 20 s records. The sections that deviated from the algorithm could not be decided. Each sleep stage decided by automatic analysis was compared with the inspection decision. The agreement ratio of stage 3 was 91.6% in the highest, and followed by stage 2, stage 4, stage W and stage 1. The lowest was 62.5% for movement time. The total agreement ratio was 85.8%. The agreement ratios of the apnea index (AI) and the apnea hypopnea index (AHI) were relatively high, but for types of sleep apnea, agreement ratios require improvement.

Adult↗

Influence of automatic word reading on motor control.

We investigated the possible influence of automatic word reading on processes of visuo-motor transformation. Six subjects were required to reach and grasp a rod on whose visible face the word 'long' or 'short' was printed. Word reading was not explicitly required. In order to induce subjects to visually analyse the object trial by trial, object position and size were randomly varied during the experimental session. The kinematics of the reaching component was affected by word presentation. Peak acceleration, peak velocity, and peak deceleration of arm were higher for the word 'long' with respect to the word 'short'. That is, during the initial movement phase subjects automatically associated the meaning of the word with the distance to be covered and activated a motor program for a farther and/or nearer object position. During the final movement phase, subjects modified the braking forces (deceleration) in order to correct the initial error. No effect of the words on the grasp component was observed. These results suggest a possible influence of cognitive functions on motor control and seem to contrast with the notion that the analyses executed in the ventral and dorsal cortical visual streams are different and independent.

Acceleration↗

Adjustment of the evoked response sensitivity after hospital discharge in pacemaker patients with automatic ventricular threshold tracking activated.

Automatic threshold tracking in cardiac pacemakers allows ventricular capture verification and self-adaptive pacing output regulation. The Autocapture algorithm detects the evoked response (ER) signal immediately after the pacing pulse to verify the efficacy of ventricular pacing. Before hospital delivery, the ER sensitivity must be programmed individually so that the pacemaker detects the ER signal adequately without sensing lead polarization. The aims of the study were to assess the frequency of patients in whom Autocapture could be activated and whether the ER sensitivity had to be adjusted after hospital discharge. The study included 44 patients who received the VVIR pacemaker Regency SR+ (St. Jude Medical) connected to the model 1450 T pacing lead. ER signal, lead polarization, and ER sensitivity were evaluated before hospital discharge and 1, 3, and 6 months after implantation. The system recommended activating Autocapture in 42 of 44 patients. The mean ER signal was 8.4+/-1.2 mV at discharge, 9.0+/-3.9 mV at month 1, 8.9+/-4.9 mV at month 3, and 9.3+/-4.5 mV at month 6. Polarization was 1.0+/-0.1 mV at discharge, 1.1+/-0.5 mV at month 1, 1.1+/-0.2 mV at month 3, and 1.1+/-0.5 mV at month 6. Mean ER sensitivity was 3.7+/-1.8 mV at discharge, 4.0+/-1.8 mV after 1, 4.1+/-2.2 mV after 3, and 4.1+/-1.8 mV after 6 months. ER sensitivity could remain unadjusted in 14 patients. Programming to a less sensitive ER setting from 2.9+/-1.2 mV to 4.3+/-1.5 mV was possible in 21 patients. Programming to a more sensitive ER setting from 4.1+/-1.1 mV to 2.5+/-0.9 mV was required in nine patients because of the decrease of the ER signal. The automatic threshold tracking algorithm Autocapture could be activated in 95% of patients. Programming to more sensitive ER settings was recommended in 21% of the patients after hospital discharge. Therefore, ER signal and polarization must be checked at each follow-up, as a decrease in ER signal amplitude can make reprogramming of the ER sensitivity necessary. There is no risk for the patient if the ER is not sensed, as high voltage backup stimulation is present.

Aged↗