Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMBS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,603 records · Page 89Linked to original sources

[Kineplastic reconstruction after upperlimb amputation (author's transl)].

In our country the preprosthetic surgical reconstruction of the upper-limb stumps based on the idea of kinematization has become a separate part of reconstructive surgery. Kineplastics- the formation of the skin-muscular canals-aimed at controlling the prosthetic-orthotic devices has acquired a new trend closely connected with the achievements of prosthetics, particularly with the development of the upper-limb externally powered prostheses. At the Leningrad Research Institute of Prosthetics 80 patients underwent kineplastic operations and 102 skin-muscular canals were formed in the period of 1975-1980. Most of the patients were severely disabled; among 65 cases there were upperlimb amputations, congenital deficiencies of the proximal shoulder girdle and disarticulations of shoulder joints. The authors improved the technique of the kineplastic operations, developed the original operations for fastening the prostheses and controlling the functional externally powered prostheses. The physiological investigations showed that the skin-muscular canals possessed a required number of commands and may be a reliable source of control. The skin-muscular canals are used for controlling prostheses, holding different devices for self-help, work and sports. This complex treatment enables the amputees not only to control the prostheses and aid devices, but also to become highly skilled workers.

Amputation, Surgical↗

The status of lower-limb amputation in Bangladesh: a 6-year review.

We conducted a review of 450 single lower-limb amputations performed in our hospital in Bangladesh between July 1982 and June 1987. The incidence of amputation in the specific area of 1000000 inhabitants covered by the hospital was 0.75/10(3) per year. The indications for amputation were: limb ischemia in 366 patients (81%), traumatic crush injury in 45 (10%), diabetes-associated complications in 20 (5%), severe limb infection in 10 (2%), and neoplasm growth in 10 (2%). The ratio of above-knee (AK) to below-knee (BK) amputation was 1:65, and 36 patients (8%) required reamputation, 22 of whom had undergone BK amputation previously. Thus, the number of patients with a final amputation at AK level was 302 (67%). The operative mortality was 21% and the uncomplicated primary wound healing rate was 89% within the survivors. Among the 355 patients who survived the amputation, 265 (75%) were given a prosthesis, 50 (14%) refused a prosthesis, and the remaining 40 (11%) were unfit for a prosthesis. Rehabilitation was successful in 44% of the AK and 86% of the BK amputees. In conclusion, when amputation is inevitable, maximum consideration should be given to the type of surgery performed to avoid rehabilitation failure.

Adolescent↗

An analysis of extended physiological proprioception as a prosthesis-control technique.

This research was devoted to an investigation of the practicality and potential effectiveness of applying the concept of extended physiological proprioception (EPP) to the control of upper-limb prostheses. The purpose of this study was to verify that EPP control, implemented by coupling prosthesis function to residual shoulder motion in a position-servo relationship, could be effectively applied in multifunctional prostheses for shoulder disarticulation amputees. Although Simpson has shown that the principle works, the authors wanted to quantify its effectiveness and analyze its limitations. Studies were performed analyzing the feasibility of using shoulder elevation-depression and protraction-retraction as prosthesis control inputs. The results of this study showed that a prosthesis mechanism with nonlimiting dynamic response characteristics and shoulder-activated EPP control of wrist rotation and elbow flexion/extension, exhibited functional characteristics comparable to those of the physiological elbow and wrist as defined by tracking capabilities. The results of this investigation also showed that shoulder-effected position control of prosthesis function has considerably more potential for providing effective control than similarly effected velocity control.

Arm↗

An aggressive approach to limb dystonia: a case report.

A 15-year-old boy presented with a severe fluctuating foot and ankle dystonia resulting from a basal ganglia insult at the age of 4. This followed an embolic event related to an undiagnosed prolapsed mitral valve. Functionally, the patient was ambulatory with rocker bottom crutches and an ankle-foot orthosis, but there were periods of up to a year when pain and increased dystonic deformity required him to use a wheelchair. A new orthotic was made nearly every month because the orthotist could find no material that would withstand his tone without breaking, yet he could not ambulate without one. Multiple interventions, including biofeedback, contrast baths, stretching and strengthening, oral lioresal (Baclofen), diazepam (Valium), benztropine mesylate (Cogentin), carbidopa-levodopa (Sinemet), carbamazepine (Tegretol), and injections of botulism toxin (BOTOX) were tried, all with minimal effects. Amputation was recommended, based on anatomic and functional considerations. The patient and his family adjusted well to this decision, although not all orthopedists and therapists adjusted easily to the choice. The patient is now functionally independent with a prosthesis and has a normal teenage lifestyle for the first time.

Adolescent↗

Claimed walking distance of lower limb amputees.

PURPOSE: Walking ability in general and specifically for lower limb amputees is of major importance for social mobility and ADL independence. Walking determines prosthesis prescription. The aim of this study was to mathematically analyse factors influencing claimed walking distance of lower limb amputees of 500 m or more. METHOD: A total of 437 patients returned two questionnaires: the Groningen Questionnaire Problems after Leg Amputation, in which walking distance was assessed, and the RAND 36. RESULTS: The chance of walking 500 m or more reduced when a transfemoral amputation was performed. The chance reduced even more when phantom pain or stump pains were present. If the amputation was performed because of vascular disease or because of vascular problems because of diabetes the chance reduced again. Independently of these factors, age reduced the chance of walking 500 m or more. CONCLUSION: The chance of walking 500 m or more reduces with increase in age and a more proximal amputation. The chance reduces even further when the amputation is performed because of diabetes or vascular disease and also if phantom pain and or stump pain is present.

Age Factors↗

The social and economic outcome after upper limb amputation.

This paper reports a study of 66 upper limb amputees in County Funen, Denmark who were visited in their homes by the author. The purpose of this study was to evaluate for the same period of time the social and economic outcome for a population of upper limb amputees compared with the normal population. The number of amputees investigated corresponds to the annual number of persons becoming upper limb amputees in Denmark. The aetiology of registered amputees also corresponds to the Danish Amputation Register. The amputees had become "better placed" in the social system after amputation independent of prosthetic use. The mean age of the amputees corresponded with the age where people reach their best social grouping. Their social migration quotient was higher than the background population and reflected the amputees better income and housing conditions. The reasons for these surprising results must be the high grade social system in a sophisticated industrial county. None of the amputees were required to pay for rehabilitation or prosthetic supply. A lower divorce rate for the amputees was explained by a symbiosis between the amputees and their partners to protect their future existence. Only 14% lived alone. Those who had their sexual debut after amputation were 3 years later in sexual experience than the rest of the amputees because of difficulties during the maturing process.

Age Factors↗

Through-knee amputation in high-risk patients with vascular disease: indications, complications and rehabilitation.

During a 10-year period 104 patients (mean age 72 years) had 106 through-knee amputations. Indications for surgery were: limb gangrene, 67 (64 per cent); ischaemic ulceration, 22 (21 per cent); rest pain, 9; knee contractures, 6. Thirty patients had had previous unsuccessful vascular reconstructive surgery and five had had a failed femoral embolectomy. The through-knee disarticulation used lateral skin flaps. The mortality was 21 (20 per cent). Of the 83 survivors, 59 (71 per cent) underwent uncomplicated primary wound healing; 36 (43 per cent) of the survivors were unsuitable for rehabilitation on a prosthesis. The remaining 47 (57 per cent) were walking before discharge 30-130 days (mean 68 days) after amputation. Through-knee amputation is a rapid, relatively bloodless, amputation and is a useful debridement procedure. The many surgical and functional advantages, in conjunction with the recent reports of better rehabilitation compared with the above-knee or Gritti-Stokes amputation, suggests that the through-knee amputation deserves greater consideration.

Aged↗

Biomechanical comparison of the energy-storing capabilities of SACH and Carbon Copy II prosthetic feet during the stance phase of gait in a person with below-knee amputation.

In this study, the energy-storing capabilities of solid-ankle cushion heel (SACH) and Carbon Copy II prosthetic feet during the stance phase of gait were compared. A person with a unilateral below-knee amputation served as a component of the instrumentation to test the feet under dynamic loads. Ten trials per foot of bilateral stride at "free" velocity were collected with a video-based, three-dimensional data-acquisition system and two force plates. There were no differences between the prosthetic conditions in step length, single-limb support time, and swing period (analysis of variance) or in double-limb support time, cadence, and velocity (Student's t test). Angular kinematics and moments of the hip and knee were unaffected bilaterally by the type of foot. The progression of the center of pressure under the Carbon Copy II was delayed from 15% to 80% of stance as compared with the SACH foot. The Carbon Copy II showed slower unloading in late stance and a later peak propulsive force than did the SACH foot. The Carbon Copy II performed greater work in both the energy-storage (Carbon Copy II = 2.33 J, SACH = 1.16 J) and energy-return (Carbon Copy II = 1.33 J, SACH = 0.34 J) phases of stance and returned energy with 57% efficiency. Although the energy returned by the Carbon Copy II was clinically insignificant during level walking, these results confirm that it performs as an energy-storing device.

Adult↗

Tolerance of early walking with total contact among below-knee amputees--a randomized test.

In order to reduce the need for repeated changes of socket due to postoperative atrophy and resorption of oedema simple temporary limbs are required to delay the casting of individual sockets until the stump is more mature. A randomized study of 95 below-knee amputees was performed with a re-usable temporary one-size prosthesis of endoskeletal type with adjustable tube length. Total contact was obtained by moulding a thin plastic pillow containing small plastic pellets around the stump in parallel connected sections. As air was evacuated the pillow became rigid. The pillow was kept in place about the stump by Velcro bands. Physiotherapists were able to make all adjustments and ambulate the patient 1-2 hours a day. The training started 2-4 weeks after amputation and lasted for 1-4 weeks. Healing problems due to training did not occur in well healed stumps where training started 3 weeks or more after amputation. No negative influence on maturing of stump, hospital stay and walking ability three months after amputation was found.

Aged↗

Biomechanical basis of choosing the rational mass and its distribution throughout the lower limb prosthesis segments.

A solution for finding a rational distribution of mass in lower limb prostheses has been considered based on the formal premise favoring the identification of the movements of a prosthetic and an intact leg. For the purpose of simplicity, and analysis has been carried out for only the swing phase, the data about the properties of moving segments being determined without integrating differential equations of motion. At the formation of equations of motion, an assumption that body segments are absolutely rigid and have constant moments of inertia and locations of the center of mass was taken into consideration. Based on independent proportions formed of combinations of the coefficients of equations of motion, a system of three equations has been formulated and solved in relation to the mass values sought: a static radius and a radius of inertia of the prosthesis complex link "shin + foot + footwear." From the six unknowns included in the equations, three values are chosen as mean values determined empirically. The solution of obtained equations results in the following conclusions: the parameters of the mass distribution in a "shin + foot + footwear" complex link depend on the amputation level and the patient's mass. These data, reported in appropriate tables, may be used in prosthetics practice. Recommendations have also been presented with regard to a prosthesic mass relative to the age of the person with amputation and a method of a balancing of prostheses aimed at the achievement of a rational distribution of masses. The analysis of obtained equations has also allowed us to make recommendations about the artificial foot mass. It has been concluded that a reasonable desire to reduce the mass of the prosthetic segments is not an end in itself, but is only the means of a rational distribution by means of balancing. It has been proved that rational prosthetic fitting results in decreased energy costs and overloads are decreased and a normalized gait.

Amputation, Surgical↗

Repeatability of kinetic and kinematic measurements in gait studies of the lower limb amputee.

During the last few years considerable attention has been given to the use of gait analysis as a tool for clinical use. The instrumentation for measurement of the kinetics and kinematics of human locomotion was originally designed for research use. Extension of its use into the clinical field calls for simplified methodology and clearly defined protocols with precise identification of the relevant parameters for the analysis. Force platforms, TV-computer and pylon transducer systems were used for collection of kinetic and kinematic data of five normal subjects, 10 below-knee, 10 above-knee and one hip disarticulation amputee. The repeatability tests showed significant differences in the measured parameters. These variations are attributed to the methodology of the analysis and the step to step variation of the subjects' gait. Differences in the degree of step to step variation between various amputee and normal subjects are quantified. In this presentation the capability of present day systems to perform repeatable gait measurements is discussed. A computational method for determination of representative measurements for the purposes of biomechanical evaluation and comparison as well as quantification of the degree of repeatability is described.

Adult↗

Brown's procedure for congenital absence of the tibia revisited.

The results of reconstructive surgery in tibial hemimelia using a modified fibular transfer procedure as described by Brown were reviewed. A modified Brown's procedure was carried out on five patients with a total of seven affected limbs. A Syme's-type amputation of the foot was carried out in each case. All of the knees had quadriceps function preoperatively, which was considered a prerequisite for surgery. Average length of follow-up was 7 years, with a range of 2-12 years. The average age at time of surgery was 12.7 months, with a range of 7-26 months. At the time of review, all patients had reasonably good function of their lower extremities. All were ambulating with patellar tendon-bearing prostheses and thigh extensions for collateral support. The average arc of motion at review was 57.4 degrees, with further passive motion possible in all cases. Average extension was -18.5 degrees, and the average active flexion was 76 degrees. We found that a fibular centralization procedure in a patient with at least grade III+ quadriceps function can give good functional results that do not appear to deteriorate over time.

Abnormalities, Multiple↗

[Influence of wall thickness on the stress distribution within transtibial monolimb].

Monolimb is a new type of lower-limb prostheses made of macromolecule polymer, in which the socket and prosthetic shank are integrative. Compared with traditional prosthesis, monolimb is more economical, good-looking and portable, so it indicates a possible direction in the future. Biomechanical research on trans-tibial monolimb is necessary and helpful just like traditional prosthesis. In this article, a 3D FE model based on real geometry shape of an endoskeletal trans-tibial monolimb is established. Keeping the same geometrical shape, three 3D FE models of transtibial monolimbs with different wall thickness are established. The influence of wall thickness on the stress distribution is analyzed under the load corresponding to the subphase of stance of Heel Off. The results indicate that stress within transtibial monolimb and pressure on the surface of soft tissue could be decreased with wall thickness of transtibial monolimb increased. This study will be helpful for the standard of wall thickness in designing transtibial monolimb.

Amputees↗

A modular six-directional force sensor for prosthetic assessment: a technical note.

A device designed to measure the forces and moments transmitted through prostheses of persons with lower limb amputation is presented. The sensing unit design is an advancement over previous prosthesis force measurement devices in that it is very thin (19 mm) and lightweight (527.5 g, including signal-conditioning instrumentation). The disk-shaped transducer fits between the socket and socket adapter of a standard modular prosthesis, measuring all six force and moment components at this location. Twelve strain gages were used, configured into six two-arm active Wheatstone bridge circuits. A 6X6 matrix was constructed from calibration data to relate the 6-component bridge-output vector to a 6-component force and moment vector. In a bench-test setting, the sensor was evaluated under typical load combinations encountered during the walking of a person with transtibial amputation (TTA) and shown to have errors less than 7.2% of the full-scale output for each direction. Data collected on a subject with TTA walking at different speeds are presented.

Amputation, Surgical↗

The experimental demonstration of a multichannel time-series myoprocessor: system testing and evaluation.

A multichannel time-series myoprocessor which combines the advantages of the parallel filtering limb function classifiers of Doerschuk et al. and the "optimal myoprocessor" muscle force estimators described by Hogan et al. have been developed and evaluated experimentally. Magnitudes and directions of knee movements were identified accurately and robustly from EMG sites intermediate to the major thigh muscles of intact individuals. Electrode placement criteria were tested, and system performance and sensitivity to contraction level as functions of channel number were computed. By including spatially distributed information into the structure of the processor, gains in accuracy and reliability over systems with fewer channels were demonstrated. Operating range increased with the number of channels included in the processor. Joint moment was estimated from multiple channels of temporally correlated data, extending and generalizing previously reported techniques. Identifying the parameters of AR models of the EMG at low levels of contraction resulted in more robust classification and joint moment estimation. Optimal electrode position could not be predicted a priori. The system may be applicable to the proportional control of myoelectric prostheses.

Adult↗

Early clinical evaluation of a robot arm/worktable system for spinal-cord-injured persons.

In Part I, "Developmental Case Study", this evaluation traces anecdotally the increasing application of microcomputer technology in a research program examining the uses of a robot arm in the rehabilitation of the high-spinal-cord-injured person. This program, supported by the Veterans Administration since 1974, built upon still earlier VA-supported work at Johns Hopkins on powered upper-limb prostheses. The Johns Hopkins University powered shoulder prosthesis served as the basis for the Robotic Arm/Worktable System, whose evolution is described in applications ranging from handling simple reading materials to self-feeding and the operation of a personal computer, all under the user's control through the same chin control interface employed for the control of the user's power wheelchair. Part II of this report focuses on the results of clinical evaluation in the development of the system. In the early stages of development, evaluation was provided by four subjects who used the system regularly for periods ranging from 4 months to a year. A later stage of evaluation featured a total of 16 subjects located in two VA Medical Centers, using the system for periods of from a few days to 4 months in duration. The VA's new Rehab R&D Evaluation Unit has begun an intensive evaluation process based upon 25 of the Robotic Arm/Worktable Systems currently on order.

Adult↗

Prosthetic use and functional and social outcome following major lower limb amputation.

A total of 175 consecutive below and above-knee amputees sent to the prosthetic workshop in Helsinki for prosthetic fitting from 32 hospitals were reviewed to determine their functional ambulation and social adaptation. The average age of the patients was 62.2 years at the time of the prosthetic fitting. The mortality was 11% (19) during the first postoperative year. One-year postoperative information was obtained for 141 of the surviving patients (90%) by personal contact. At the time of the review, 68% of the amputees (96 patients) who had been fitted with a prosthesis made extensive and regular use of it. Half of all the above-knee amputees and 79% of the below-knee amputees used their prosthesis throughout the day or over seven hours a day. A total of 72% of the above-knee amputees (33/46) and 85% of the below-knee amputees (67/79) had useful ambulation, at least indoors. Of the 141 patients contacted, 124 (88%) lived in their own homes. The remaining 16 patients (11%) lived in apartment houses for the aged or old people's homes. A total of 48 amputees (34%) needed a regular home help.

Adolescent↗

A prospective study examining balance confidence among individuals with lower limb amputation.

PURPOSE: In this study we assessed whether balance confidence scores changed over a 2-year follow up period, and identified predictors of balance confidence and predictors of change in balance confidence among lower limb amputees. METHOD: A prospective follow-up survey of 245 community living adults with unilateral below and above knee lower limb amputation who used their prosthetic limb daily was conducted. Balance confidence, assessed using the 16-item Activity-specific Balance Confidence (ABC) Scale, socio-demographic, health and amputation related variables were collected at baseline and 2 years later. RESULTS: ABC scores were similar at baseline (mean = 67.6; SD = 25.7) and follow up (mean = 68.0; SD = 25.8). Lower balance confidence scores at follow up were predicted by older age, being female, use of a mobility device, poor perceived health, increased symptoms of depression, having to concentrate while walking, and fear of falling (all p < 0.05). Predictors of change in balance confidence included gender and perceived health (all p < 0.05). CONCLUSION: Balance confidence appears to be a persistent problem in the amputee population. Health professionals are encouraged to consider balance confidence as a potentially important variable that may influence function in this clinically unique group of individuals. The identified predictor variables may be useful to clinicians in targeting individuals who require attention to improve balance confidence.

Activities of Daily Living↗