Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up.

BACKGROUND: We report the results of cementless total hip arthroplasty with a tapered, rectangular titanium stem that was introduced in 1979 and continues to be used today with only minor changes. The aim of the design is to achieve primary stability to resist rotational and axial forces through precision rasping and press-fit implantation of a tapered, rectangular femoral component. METHODS: Between October 1986 and November 1987, 208 total hip arthroplasties with insertion of a tapered, rectangular titanium stem and a threaded cup without cement were performed in 200 consecutive patients (average age, sixty-one years; range, twenty-two to eighty-four years). RESULTS: At the time of the latest follow-up, fifty-one patients (fifty-two hips) had died and sixteen patients had been lost to follow-up, leaving 133 patients. Twelve hips had been revised, two in patients who subsequently died, leaving 123 living patients without revision. The median follow-up time was 120.7 months. Five cups needed revision surgery because of aseptic loosening; two, because of massive polyethylene wear; one, because of posttraumatic migration; and one, because of breakage. Three femoral stems were revised: one because of malpositioning (the reoperation was done five days after implantation); one, because of infection; and the third, after multiple failed acetabular revisions. The mean Harris hip score for the patients who did not have revision was 85.4 points (range, 46 to 100 points) at the time of the latest follow-up. Four patients (3%) complained of thigh pain that was not associated with another disorder. According to the criteria of Engh et al., all femoral implants were graded as stable bone-ingrown. The probability of survival of both the femoral and the acetabular component at ten years, with any revision as the end point, was 0.92 (95% confidence interval, 0.88 to 0.97). The probability of survival of the cup was 0.93 (95% confidence interval, 0.89 to 0.97), and that of the stem was 0.99 (95% confidence interval, 0.97 to 1.00). CONCLUSIONS: The results of arthroplasty with a tapered, rectangular titanium stem combined with a conical threaded cup inserted without cement were excellent at a minimum of ten years. Our data suggest that femoral stem fixation continues to be secure, while the threaded cup is prone to aseptic loosening.

Adult↗

Management of Mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization.

BACKGROUND: Radial head fractures often occur in association with other elbow fractures and soft-tissue injuries. Radial head replacement is indicated for irreparable radial head fractures associated with elbow instability. The purpose of this study was to analyze the results after treatment of such injuries with a titanium radial head prosthesis, repair of torn collateral ligaments, and early mobilization of the elbow. METHODS: Sixteen patients with sixteen Mason type-III radial head fractures and collateral ligament injury were treated with use of a titanium radial head prosthesis over a five-year period at the Royal Adelaide Hospital and Modbury Public Hospital in South Australia. The surgery was performed acutely in ten patients and was delayed an average of thirty-seven days (range, fifteen to seventy-nine days) in six. All patients were followed clinically and radiographically for a mean of 2.8 years (range, 1.2 to 4.3 years). RESULTS: Eight patients had an excellent result; five, a good result; and three, a fair result, according to the Mayo Elbow Performance Score. The three fair results occurred in patients with delayed surgery. The mean flexion contracture was 15 degrees (range, 0 degrees to 42 degrees ), with an average loss of 10 degrees (range, 0 degrees to 25 degrees ) of full flexion compared with that of the contralateral elbow. Both pronation and supination decreased an average of 12 degrees (range, 0 degrees to 45 degrees ) compared with that of the contralateral forearm. CONCLUSIONS: The results of treatment of Mason type-III radial head fractures with a monoblock titanium radial head prosthesis and soft-tissue reconstruction are satisfactory. Early mobilization of the elbow is important for the restoration of elbow range of motion and function.

Adult↗

Management of Mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization. Surgical technique.

BACKGROUND: Radial head fractures often occur in association with other elbow fractures and soft-tissue injuries. Radial head replacement is indicated for irreparable radial head fractures associated with elbow instability. The purpose of this study was to analyze the results after treatment of such injuries with a titanium radial head prosthesis, repair of torn collateral ligaments, and early mobilization of the elbow. MATERIALS: Sixteen patients with sixteen Mason type-III radial head fractures and collateral ligament injury were treated with use of a titanium radial head prosthesis over a five-year period at the Royal Adelaide Hospital and Modbury Public Hospital in South Australia. The surgery was performed acutely in ten patients and was delayed an average of thirty-seven days (range, fifteen to seventy-nine days) in six. All patients were followed clinically and radiographically for a mean of 2.8 years (range, 1.2 to 4.3 years). RESULTS: Eight patients had an excellent result; five, a good result; and three, a fair result, according to the Mayo Elbow Performance Score. The three fair results occurred in patients with delayed surgery. The mean flexion contracture was 15 degrees (range, 0 degrees to 42 degrees ), with an average loss of 10 degrees (range, 0 degrees to 25 degrees ) of full flexion compared with that of the contralateral elbow. Both pronation and supination decreased an average of 12 degrees (range, 0 degrees to 45 degrees ) compared with that of the contralateral forearm. CONCLUSIONS: The results of treatment of Mason type-III radial head fractures with a monoblock titanium radial head prosthesis and soft-tissue reconstruction are satisfactory. Early mobilization of the elbow is important for the restoration of elbow range of motion and function.

Algorithms↗

Blade crossing of a pure titanium clip applied to a cerebral aneurysm--case report.

Titanium aneurysm clips are superior to cobalt clips in radiological features, biocompatibility, and hypoallergenicity, but the mechanical characteristics are less advantageous. A 56-year-old man was referred to our department due to dizziness and slurred speech. Cerebral angiography unexpectedly disclosed an aneurysm of the right middle cerebral artery. The patient underwent right frontotemporal craniotomy and neck clipping of the aneurysm with a commercially pure titanium clip. After application of the clip, the clip blades crossed and nearly sheared the wall of the aneurysm. The mechanical characteristics of titanium aneurysm clips require careful consideration because of possible clip malfunction.

Equipment Failure↗

[Application of chrome-cobalt alloys containing titanium in inner and outer cone-telescope crown].

The chrome cobalt alloys containing titanium (Dentitan) has excellent porcelain-to-metal bond strength. Therefore, it is used as outer telescope crown alloys of cone telescope denture in actual clinic. The purpose of this study is to investigate the fitness and the change of metal before or after porcelain firing of chrome-cobalt alloys containing titanium. The results of this investigation indicate that (1) chrome-cobalt alloys containing titanium can be used as metal for inner crown because it showed the same degree of fitness compared with precious metal, and (2) the optimal water/powder ratio of the outer telescope crown was 28 ml; 2 ml, or 27 ml; 3 ml, and (3) although the full porcelain veneer-coverage was greater vertical distortion than the partial-veneer-coverage, either metal can be applied to outer crown by adjusting of the retention.

Chromium Alloys↗

Bone nanostructure near titanium and porous tantalum implants studied by scanning small angle x-ray scattering.

Bone sections including either titanium or porous tantalum implant devices used for interbody spinal fusion were investigated with position-resolved small angle X-ray scattering (sSAXS). The samples were obtained from six-month-old pigs that had undergone surgery three months prior to sacrifice. The aim of the study was to explore the possibility of using sSAXS to obtain information about thickness, orientation and shape/arrangement of the mineral crystals in bone near the implant surfaces. Detailed sSAXS scans were carried out in two different regions of bone adjacent to the implant in each of the implant samples. In the implant vicinity the mineral crystals tended to be aligned with the surface of the implants. The mean crystal thickness was between 2.1 and 3.0 nm. The mineral crystal thickness increased linearly with distance from the implant in both regions of the porous tantalum implant and in one of the regions in the titanium sample. In the second region of the titanium sample the thickest mineral crystals were found close to the implant surface. The observed differences in mineral thickness with distance from the implant surfaces might be explained by differences in mechanical load induced by the implant material and the geometrical design of the implant. The study shows that sSAXS is a powerful tool to characterize the nanostructure of bone near implant surfaces.

Humans↗

Comparison of osseointegration between hydroxyapatite-coated and uncoated threaded titanium dental implants placed into surgically-created bone defect in rabbit tibia.

The purpose of this study was to compare the degree of osseointegration between hydroxyapatite (HA)-coated and uncoated threaded titanium dental implants placed into a surgically created bone defect with or without an expanded polytetrafluorethylene (ePTFE) membrane. A conventional implant site was prepared and either a HA-coated or an uncoated implant was placed in each tibia of 12 rabbits (conventional group). A bone defect approximately 3 mm in width was created on the distal end of the conventional site and either a HA-coated or an uncoated implant was placed there (bone defect group). For another group, the same procedure was performed as in the bone defect group, except the implant sites were covered with ePTFE membranes (ePTFE group). After 4 months, the rabbits were sacrificed. Specimens were prepared and examined histometrically. The results demonstrated that HA-coated threaded titanium dental implants consistently showed a greater amount of osseointegrated surface either in the conventional site or defect region with and without ePTFE membranes in this animal model. In conclusion, a HA-coated threaded titanium implant may be the choice of dental implants to establish greater osseointegration with the defect or conventional site.

Animals↗

Effects of ipriflavone on bone augmentation within a titanium cap in rabbit calvaria.

Ipriflavone (7-isopropoxyisoflavone, IP), a drug used in the treatment of osteoporosis, may promote bone formation during bone remodeling. IP has been shown to accelerate both the activity of, and formation of mineralized nodules by a human osteosarcoma cell line at an early stage. However, the direct effects of IP on bone augmentation have not been investigated. The purpose of this study was to determine whether IP induces bone augmentation within a titanium cap in rabbit calvaria at an early stage. Five adult male Japanese white rabbits were used. One cap (test site) was packed with IP in a collagen gel, and the other (control site) was packed with the collagen gel alone. After the one- and three-month healing periods, we measured the newly generated tissue and bone within the titanium caps. The amount of newly generated tissue within the titanium caps of the control sites was higher than the tests sites after one month and three months. However, the percentage of newly generated bone/bone marrow in the newly generated tissue at the test sites was higher than for the control sites after one month and three months. These results suggest that IP affects the quality of bone augmentation at an early stage.

Animals↗

Titanium, a major constituent of blue ink, causes resistance to Nd-YAG (1064 nm) laser: results of animal experiments.

A blue tattoo is more resistant to laser therapy than black or brown tattoos. This study aimed to confirm titanium as a key response-disturbing constituent in a blue tattoo ink after Nd-YAG (1064 nm) laser treatment by animal experiments. Rabbits' backs were tattooed with four ink colours, and the Nd-YAG (1064 nm) laser was used to remove the tattoos. The response to the laser treatment in the rabbits was evaluated and electron microscopic studies were also performed. Excellent to fair responses were observed for the black, brown and dark brown inks, but the blue ink responded poorly to the laser. Histological examination indicated that the blue pigments were unchanged even after the laser treatment. Quantitative energy dispersive spectrometry revealed that blue ink contained high amounts of titanium. Our animal experiments confirm that a blue tattoo ink containing titanium, is a key element in poor response to the Nd-YAG laser.

Animals↗

Use of a rivet-like titanium clamp closure system to replace an external frontal bone flap after transfrontal craniotomy in a dog.

A 10-year-old spayed female dog was referred for surgical removal of a brain tumor that had been identified following an acute onset of seizure activity 2 weeks earlier. A computed tomographic evaluation involving contrast agent revealed the presence of a contrast-enhanced mass within the left olfactory lobe of the brain. After removal of the mass via a transfrontal craniotomy, the overlying frontal bone flap was replaced and secured by use of a biologically inert rivet-like titanium clamp closure system and 3 titanium alloy craniotomy line clamps. On reevaluation 4 weeks after tumor removal, the dog was free of seizure activity and had no proprioceptive deficits; according to the owner, the dog had marked improvement in its overall behavior and attitude. The titanium clamp closure system appears to offer an effective and rapid technique for the secure replacement of craniotomy bone flaps in dogs.

Animals↗

Stabilization of the nipple base with titanium rings when reoperating patients with continent urostomies for nipple dysfunction.

Nipple dysfunction in Kock reservoirs used for continent urinary diversion is usually caused by a flattening out of the intestinal nipple due to a lateral tore at the base of the nipple when the reservoir expands. This study describes a new method to repair dysfunctioning nipples based on the use of titanium rings applied outside the reservoir around the base of the nipple. Experiments on dogs and rats have shown that rings and plates of titanium rapidly attach to the serosal surface of ileum exposed to urine with only minor signs of inflammation. Ten patients with Kock reservoirs for urinary diversion have been reoperated for nipple dysfunction due to nipple sliding with elongation of the nipple and fixation of the nipple base with titanium rings. The functional result is excellent in 9 out of the 10 patients. No signs of erosion of the rings into the reservoirs have been noted. With this new method for nipple repair the need for using more intestine to construct a new nipple is eliminated.

Adult↗

Titanium implants permanently penetrating human skin.

Titanium implants were allowed to penetrate the skin of the upper arm of 8 human volunteers in an attempt to investigate the conditions for a permanent implant transcutaneous passage. If a construction was used that restricted the skin movements around the implant no inflammatory or other adverse soft tissue effects were noted for follow-up periods of 7-25 months. In another clinical investigation of 4 patients with hearing impairment, titanium implants were firmly anchored in the temporal bone, allowed to penetrate the skin and external hearing aids were directly attached. These transcutaneous implants are still functioning without any problems at a follow-up period of 38-50 months. The reason for the favorable results achieved are thought to be connected to the material (non-alloyed titanium), the design of the implant and a minimally traumatising surgery. The results of this paper are pointing to new treatment possibilities using external prostheses anchored to the skeleton via skin penetrating mechanical connections as e.g. stable and permanent episthesis attachment in cases of severe facial injuries. A clinical trial along these lines is presently being performed.

Adult↗

Comparison of ceramic and titanium implants in cats.

The mechanical strengths of the bone-implant interfaces of titanium coated with glass ceramic and pure titanium implants were compared. The glass ceramic had a chemical composition similar to 45S5F Bioglass. Cylindrical implants were placed in feline femurs. Six weeks later the strength of the fixation was tested using pull-out tests. Energy dispersive X-ray microanalysis was applied to pursue any possible relationship between mechanical strength and changes in elemental composition at the bone-implant interface. The ultimate shearing force for the pure titanium implants was higher than for the implants coated with glass ceramic. Also, the glass ceramic coating was partly degraded by the tissues. Evidently, the mechanical properties of the glass ceramic to bone interface were governed by some sort of chemical reaction that implied transfer of elements from the implant to bone. It appears that this reaction eventually will destroy the coating which makes this kind of material unsuitable for prosthesis fixation.

Animals↗

Increased metal release from cemented femoral components made of titanium alloy. 19 hip prostheses followed with radiostereometry (RSA).

In 19 patients the concentrations of metal were measured in serum, urine and joint fluid 2 years after implantation of uncemented commercially pure titanium acetabular cups and cemented or uncemented femoral components made of titanium alloy. A ceramic against the polyethylene articulation was used. The fixation of the components was followed with radiostereometry (RSA). Samples from 12 patients scheduled for hip or knee prostheses and without any metallic implant were used as controls. High levels of titanium were found in cemented hips and when large acetabular cups had been inserted. Increased aluminum levels were also noted in the cemented hips. Vanadium was not detected in any of the samples. Micromotions were detected in most of the implants, but the magnitude of these movements could not be used to predict the release of metal into the synovial fluid.

Adult↗

Osseointegration of titanium implants in the tibia. Electron microscopy of biopsies from 4 patients.

We studied the ultrastructure of bone tissue around implants of pure titanium inserted into the tibia in 4 patients with arthrosis or rheumatoid arthritis. Three main appearances of the interface were noted. First, a close contact between titanium and calcified bone with living osteocytes inside the newly-formed bone was observed in all samples. Secondly, a close contact was also seen between the implant and osteoid, the newly formed collagenous matrix being either uncalcified or calcifying. Thirdly, a loose extracellular matrix with fibrillar and nonfibrillar materials was sometimes observed between bone mineral and implant. There was no inflammatory reaction at the interface. We concluded that the titanium implants were osseointegrated, but the calcification of the bone tissue was not complete even after 20 months. However, mineralization of osteoid and living bone cells revealed the presence of an active tissue.

Arthritis, Rheumatoid↗

Polyethylene and titanium alloy particles reduce bone formation. Dose-dependence in bone harvest chamber experiments in rabbits.

Particles similar to those generated from joint replacements affect net bone formation within the Bone Harvest Chamber in rabbits. Whether these effects depend on the concentration of particulate materials is unknown. In this study, we performed a histomorphologic and morphometric analysis of net bone formation in the Bone Harvest Chamber in the presence of different concentrations of phagocytosable particles of high density polyethylene and titanium 6-aluminum 4-vanadium alloy. Chambers were implanted in 9 mature New Zealand white rabbits bilaterally. Concentrations of 10(6), 10(7) and 10(8) polyethylene particles/mL, and 10(8) and 10(9) particles/ mL of titanium alloy in 1% sodium hyaluronate carrier were implanted for 3-week periods in sequence in each of the chambers. 3-week control periods in which nothing was implanted in the chamber were included between the treatments. Increasing concentrations of polyethylene particles were associated with a more marked foreign body response and fibrosis. Net bone formation for the three polyethylene doses was reduced by 11%, 21% and 33% of controls, respectively. For titanium alloy, net bone formation was reduced by 8% and 56% of controls, for concentrations of 10(8) and 10(9) particles/mL, respectively. Our findings suggest possible adverse effects of wear debris on net bone formation and bony remodeling in the prosthetic bed, when concentrations of specific particles reach critical local levels.

Alloys↗

Use of titanium mesh for reconstruction of large anterior cranial base defects.

The authors evaluated the role of titanium mesh used in combination with vascularized pericranium to provide rigid support during reconstruction of anterior skull base defects. Thirteen patients with large anterior skull base defects caused by tumor invasion or traumatic injury involving the cribriform plate, orbital roof, and planum sphenoidale were included in the study. The reconstruction technique involved placement of titanium mesh between two layers of continuous vascularized pericranium. Surgical glue and routine lumbar cerebrospinal fluid (CSF) drainage were not used in any patient. At a mean postoperative follow-up time of 22 months (range 8-39 months), none of the patients had developed infection or meningocele. Postoperative CSF rhinorrhea occurred in two patients with extensive dural defects, which resolved with temporary lumbar drainage. Use of titanium mesh and a two-layer vascularized pericranial graft is a safe, reproducible, and feasible method for reconstructing the anterior skull base. Patients with large dural defects may need temporary CSF diversion to avoid postoperative fistula formation.

Adult↗

Use of cylindrical titanium mesh and locking plates in anterior cervical fusion. Technical note.

After performing anterior cervical corpectomy or discectomy for cervical spondolytic myelopathy or radiculopathy, iliac crest bone graft and fibular auto- or allograft is often used to achieve arthrodesis in the cervical spine. The purpose of this study was to evaluate the use of a cylindrical titanium mesh and locking plate system as an alternative technique in achieving anterior cervical fusion and maintaining lordosis. Hospital records and radiographs of 38 patients who underwent anterior cervical discectomies (28 patients) or corpectomies (10 patients) from 1995 to 1997 were reviewed retrospectively. All patients had undergone arthrodesis in which autograft and a cylindrical titanium mesh and anterior locking plate fixation were used after discectomy or corpectomy. There were 20 men and 18 women (mean age 46.1 years; range 34-72 years). Presenting symptoms included radiculopathy (61%), myelopathy (37%), and neck pain (2%). Preoperative and postoperative radiographs were studied, and data were obtained on the following: overall lordosis or kyphosis of the cervical spine, segmental lordosis or kyphosis at each surgically treated level, and evidence of fusion. In all of the patients in whom lordosis was present preoperatively, lordosis was maintained during the follow-up period. The overall fusion rate was 100%. The average change in overall lordosis or kyphosis related to the fixation devices was 1.2 degrees (range 1-5 degrees) the average segmental change was 2.3 degrees (range 0-5 degrees); and the mean follow up was 16 months (range 12-36 months). Anterior cervical fusion with cylindrical titanium mesh and cervical locking plate system is an effective method of achieving arthrodesis and maintaining alignment in the cervical spine. The construct may provide additional load-sharing function, and it avoids the use of cadaveric bone or the need for harvesting tricortical iliac crest autograft.

Adult↗