Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Spectral estimation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

Inference of motor unit recruitment order in voluntary and electrically elicited contractions.

The relationship between surface myoelectric signal parameters and the level of voluntary or electrically elicited contractions was studied in 32 experiments on the tibialis anterior muscle of 22 healthy human subjects. Contractions were performed at 20 and 80% of the maximum voluntary contraction torque. Two levels of stimulation current were used, yielding, respectively, a maximum M wave and an M wave approximately 30% of the maximum. A four-bar electrode probe was used to detect single- and double-differential signals from which mean and median frequency of the power spectrum and average muscle fiber conduction velocity were estimated. Measurements obtained from voluntary contractions showed a positive correlation between contraction levels and both conduction velocity and spectral parameters. Conduction velocity increased by 21.2 +/- 10.9% when voluntary contraction level increased from 20 to 80% of the maximal value. Spectral parameters increased by similar amounts. Tetanic electrical stimulation was applied to a muscle motor point for 20 s via surface electrodes. Rectangular current pulses with 0.1-ms width and frequencies of 20, 25, 30, 35, and 40 Hz were used. Four types of behavior were observed with increasing stimulation level: 1) the two spectral parameters and conduction velocity both increased with stimulation in 15 experiments, 2) the two spectral parameters decreased and conduction velocity increased in 8 experiments, 3) the two spectral parameters and conduction velocity both decreased in 6 experiments, and 4) the two spectral parameters increased and conduction velocity decreased in 3 experiments. Conduction velocity increased with increasing stimulation current in 72% of the experiments, indicating a recruitment order similar to that of voluntary contractions, although it decreased in the other 28% of the cases, indicating a reverse order of recruitment. Contrary to what is observed in direct stimulation of nerves, motor units are not in general recruited in reverse order of size during electrical stimulation of a muscle motor point. This discrepancy may be the result of geometric factors or a lack of correlation between axonal branch diameter and the diameter of the parent motoneuron axon. Changes of conduction velocity and spectral parameters in opposite directions may be the result of the combined effect of the motor unit recruitment order and of the different tissue filtering function associated with the geometric location of the recruited motor units within the muscle.

Adult↗

[Time-frequency analysis of ventricular fibrillation. An experimental study].

INTRODUCTION AND OBJECTIVES: The analysis of frequency variability during ventricular fibrillation has yielded inconsistent results. We used an experimental model of ventricular fibrillation, with a short timescale, to analyze variations in frequency and their associated spatial distribution. METHODS: Epicardial recordings of ventricular fibrillation were made in 10 perfused isolated rabbit heart preparations using a multiple electrode system (i.e., 240 unipolar electrodes). Both spectral and time-frequency analysis were used to derive the dominant frequency in the anterolateral wall of the left ventricle. RESULTS: Linear regression analysis showed that there was a good correlation between the dominant frequency obtained using the two signal analysis methods: frequency (spectral analysis) = 1.01 x frequency (time-frequency analysis) -- 0.4 (r=0.9; P< .0001; standard error of the estimate, 2.2 Hz). In all cases except one, the dominant frequency exhibited a significant temporal variation on a short timescale (time-frequency analysis); the coefficient of variation was between 0.19 (0.06) and 0.24 (0.07) (NS). In all cases, there were significant differences between regions. The location at which the frequency was highest varied according to the timepoint considered, though it was predominantly in the apical or anterior zone. CONCLUSIONS: In the absence of external modulating factors, the frequency of ventricular fibrillation exhibits temporal and spatial variations which can be observed at short timescales. In the free wall of the left ventricle, the dominant frequency is highest in the apical and anterior zones, and the maximum frequencies are most often found in these zones.

Animals↗

Song discrimination by male cicadas Cicada barbara lusitanica (Homoptera, Cicadidae).

Cicada barbara lusitanica males presented a stereotyped singing response behaviour when exposed to a playback of the conspecific song. Males preferred (as measured by the time taken to sing) the conspecific signal to heterospecific songs that differed markedly in temporal pattern. Manipulation of the gross temporal pattern of C. barbara calling song significantly reduced stimulus attractiveness. Indeed, C. barbara males stopped responding to stimuli in which the temporal pattern approached the characteristic C. orni song, a sympatric and closely related species. If present in females, the preference for stimuli with pauses not exceeding 30 ms could reflect the evolution of a behavioural pre-copulatory isolating mechanism based on song analysis. Males discriminated frequencies within 3-15 kHz, clearly preferring 6 and 9 kHz; both these frequencies matched the main spectral peaks of the song. The preference for specific frequencies was not associated with maximum neuronal excitation as estimated by auditory nerve recordings, which suggests that this frequency-dependent behaviour is not based on the strength of the auditory system's response to different frequencies. Rather, it is likely to reflect fine frequency resolution in the central nervous system.

Acoustic Stimulation↗

Identification of illuminant and object colors: heuristic-based algorithms.

In everyday scenes, from perceived colors of objects and terrains, observers can simultaneously identify objects across illuminants and identify the nature of the light, e.g., as sunlight or cloudy. As a formal problem, identifying objects and illuminants from the color information provided by sensor responses is underdetermined. It is shown how the problem can be simplified considerably by the empirical result that chromaticities of sets of objects under one illuminant are approximately affine transformations of the chromaticities under spectrally different illuminants. Algorithms that use the affine nature of the correlation as a heuristic can identify objects of identical spectral reflectance across scenes lit simultaneously or successively by different illuminants. The relative chromaticities of the illuminants are estimated as part of the computation. Because information about objects and illuminants is useful in many different tasks, it would be more advantageous for the visual system to use such algorithms to extract both sorts of information from retinal signals than to discount either automatically at an early neural stage.

Algorithms↗

Optimal signal bandwidth for the recording of surface EMG activity of facial, jaw, oral, and neck muscles.

Spontaneous pericranial electromyographic (EMG) activity is generally small and is contaminated by strong low-frequency artifacts. High-pass filtering should suppress artifacts but affect EMG signal power only minimally. In 24 subjects who performed a warned simple reaction time task, the optimal high-pass cut-off frequency was examined for nine different pericranial muscles. From four experimental conditions (visual and auditory reaction signals combined with hand and foot responses), 1-min EMG recordings were selected (bandwidth: 0.4-512 Hz) and divided into 60 1-s data segments. These segments were high-pass filtered, the -3-dB cut-off frequency varying from 5 to 90 Hz, and subjected to power spectral analysis. Optimal high-pass filter frequencies were determined for the mean power spectra based on visual estimation or comparison with a theoretical spectrum of the artifact-free EMG signal. The optimal frequencies for the different muscles varied between 15 and 25 Hz and were not influenced by stimulus or response modality. For all muscles, a low-pass filter frequency between 400 and 500 Hz was appropriate.

Adult↗

[Electron excitation temperature of argon dielectric barrier discharge at atmospheric pressure].

The electron excitation temperature was measured by the intensity ratio of two spectral lines in argon dielectric barrier discharge (DBD) at atmospheric pressure. The spectral range is from 690 to 800 nm. It is shown that all of the spectral lines are attributed to neutral Ar atoms. The spectral line 763.51 nm (2P(6)-->1S(5)) and 772.42 nm (2P(2)-->1S(3)) are chosen to estimate the electron excitation temperature. The experimental results show that the electron excitation temperature is in the range of 0.1-0.5 eV. The electron excitation temperature increases with increasing applied voltage, but decreases with increasing gas flow rate. The electron excitation temperature in flowing Ar gas discharge is much different from that in static Ar gas discharge. The result is of great importance to industrial application of DBD.

Algorithms↗

Characterization of arm-gun movement during air pistol aiming phase.

AIM: Air pistol shooting is a sport requiring extreme movement precision. The purpose of our study is to collect and analyze kinematic data of arm/gun complex during the pointing phase in order to characterize movement and between segment coordination by means of time and frequency domain analysis techniques. METHODS: Thirteen air pistol athletes participated to the recording sessions held at the 10 m shooting range. Kinematic data of neck, shoulder, elbow, wrist and gun were collected during the aiming phase using an optoelectronic motion capture system. Displacement series were split up in slow drift and tremor components. Amplitude of the movement of each segment and strength of the relationship between adjacent segments were estimated in time domain respectively by means of standard deviation and coefficient of regression. Moreover, coherence and phase spectral functions were calculated to assess between-segment coupling at different frequencies. RESULTS: Significantly larger movements were seen for slow drift component with respect to tremor one for all segments especially for lateral movements. Higher between segment correlation were found for lateral direction and for slow drift component. The coherence calculated on vertical series of tremor component showed significant coupling at 1.5 Hz and 5-7 Hz with phase opposition between wrist and gun motion at 5-7 Hz. CONCLUSIONS: Slow drift motion appears to affect mainly lateral movements and all the segments were equally involved indicating a probable origin in postural body sway. Vertical displacements could be referred to shoulder and wrist motion with features typical of physiological tremor. Quantitative characterization of segments displacements during aiming phase may serve as a basis for scientific evaluation and training in competitive precision shooting.

Adolescent↗

[Coherent-phase characteristics of the cortical potentials over a wide frequency range in dogs in a state of calm wakefulness].

The spectra of coherence (Coh) and phasic shifts (PhS) of cortical potentials were studied by correlation-spectral analysis in a wide frequency range (1--100 Hz) in dogs in a state of quiet wakefulness. Estimation was made by parameters: significant Coh (above 0.5), high Coh (above 0.75), considered PhS (not above +/- 30 degrees), small PhS (not above +/- 15 degrees C). The presence is shown of individual features in coherent-phasic characteristics of neocortex potentials. High values of cross-correlation coefficients (Cc) between cortical potentials correspond in Coh spectra to a great part (90--100% peaks) of significant Coh, in which the great part (90--70% peaks) belongs to the high Coh with small PhS (in most cases). A certain correspondence, though expressed weaker, persisted also for lower values of Cc, Coh, and considered PhS. Coherent-phasic relations between potentials of certain cortical areas are characterized by stability in each animal; a tendency to it is manifest in all animals, despite individual differences of the brain electrical activity.

Animals↗

[Spectrum analysis of stabilograms with special reference to changes following whole body vibration].

The location of the body's gravicenter in the horizontal plane was measured by means of a force platform. The 4 male subjects stood upright with eyes closed. Power-density spectra of the frontal and sagittal stabilograms were estimated. Repeated investigations made it possible to assess intraindividual variability and to evaluate significant interindividual differences. The power spectral density was not altered by a controlled sitting posture observed for 30 min. Low-frequency whole-body vibration with an exposure time of 30 min and a permissible level according to the "fatigue decreased proficiency boundary" (International Standard ISO 2631) induced a significant increase of the power spectral density below 0.25 Hz and a decrease above this frequency. The results indicate that the power density spectral analysis of stabilograms is a suitable method for evaluating a biological effect of vibration.

Humans↗

[Optical density of human macular pigment in spectral sensitivity measurements].

Optical density of the human macular pigment was measured by studying the spectral sensitivities to 1 degree, 200 ms test flashes on a 430 nm monochromatic background in the fovea and 10 degrees outside the fovea. Narrow-band (6 to 10 nm half band width) interference filters were used for the test lights. The difference between the spectral sensitivity in the fovea and outside the fovea coincided with the optical density of the macular pigment estimated previously by psychophysical means. We suggest that this method is useful for investigating the optical density of human macular pigment.

Adult↗

[The physicochemical status of the plasma membranes of rat fatty tissue and liver in the late periods after gamma irradiation at a dose of 1 Gy. Structural changes in the membranes].

The structural status of plasma membranes of adipose tissue and liver of rats was investigated at remote times (from 15 to 380 days) after single 1-Gy gamma irradiation. The structural status was estimated by pyrene excimerisation parameters and also by both induction resonance energy transfer method and membrane tryptophan fluorescence spectral characteristics. On days 50-100 following irradiation the microviscosity of a lipid phase of membranes increased and the mode of lipid/protein interactions changed, whereas at later times the indices under study did not vary from the controls. Comparison of the data obtained with the former results on lipid content changes indicates that the physicochemical status of plasma membranes in rat adipose tissue and liver is modified at remote times following 1-Gy gamma irradiation.

Adipose Tissue↗

[Hypochromic effect of signal attenuation in 31P-NMR spectra of linear polyphosphates].

Chemical shifts in 31P-NMR spectra of linear polyphosphates were studied. In each polyphosphate species tested, the sum of signal intensities of the internal (core) phosphate groups was proportional to the concentration of each polyphosphate, but the contribution of such groups to the total intensity of the signal decreased with increasing the length of the polyphosphate chain. An equation for estimating the polyphosphate chain length in biological objects taking into account a decrease in the 31P-NMR spectral intensity is proposed.

Nuclear Magnetic Resonance, Biomolecular↗

Rapid determination of Swiss cheese composition by Fourier transform infrared/attenuated total reflectance spectroscopy.

There is a need for rapid and simple techniques that can be used to predict the quality of cheese. The aim of this research was to develop a simple and rapid screening tool for monitoring Swiss cheese composition by using Fourier transform infrared spectroscopy. Twenty Swiss cheese samples from different manufacturers and degree of maturity were evaluated. Direct measurements of Swiss cheese slices (approximately 0.5 g) were made using a MIRacle 3-reflection diamond attenuated total reflectance (ATR) accessory. Reference methods for moisture (vacuum oven), protein content (Kjeldahl), and fat (Babcock) were used. Calibration models were developed based on a cross-validated (leave-one-out approach) partial least squares regression. The information-rich infrared spectral range for Swiss cheese samples was from 3,000 to 2,800 cm(-1) and 1,800 to 900 cm(-1). The performance statistics for cross-validated models gave estimates for standard error of cross-validation of 0.45, 0.25, and 0.21% for moisture, protein, and fat respectively, and correlation coefficients r > 0.96. Furthermore, the ATR infrared protocol allowed for the classification of cheeses according to manufacturer and aging based on unique spectral information, especially of carbonyl groups, probably due to their distinctive lipid composition. Attenuated total reflectance infrared spectroscopy allowed for the rapid (approximately 3-min analysis time) and accurate analysis of the composition of Swiss cheese. This technique could contribute to the development of simple and rapid protocols for monitoring complex biochemical changes, and predicting the final quality of the cheese.

Analysis of Variance↗

31P NMR spectra of rod outer segment and sarcoplasmic reticulum membranes show no evidence of immobilized components due to lipid-protein interactions.

31P NMR studies of rod outer segment (ROS) and sarcoplasmic reticulum (SR) membranes have been performed under conditions where broad and narrow spectral components can be clearly resolved. Control studies of an anhydrous, solid powder of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), as well as aqueous binary mixtures of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC) and 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC), demonstrate clearly that broad spectral components can be detected. For the codispersions of DSPC and DOPC in the mixed-phase region at 22 degrees C, the 31P NMR spectra consist of a superposition of a broad component and a narrow, axially symmetric component, due to coexisting solid and liquid-crystalline domains, which are in slow exchange on the 31P NMR time scale. The 31P NMR spectra of the native ROS and SR membranes, however, consist of only a narrow component, to within experimental error, indicating that most or all of the phospholipids are in the liquid-crystalline (L alpha) phase at 22 degrees C. The above conclusions are in agreement with many, but not all, previous studies [see, e.g., Yeagle, P.L. (1982) Biophys. J. 37, 227-239]. It is estimated that at most 10% of the phospholipids in the ROS and SR membranes could give rise to broad 31P NMR spectral components, similar to those seen for anhydrous or solid-phase lipids, corresponding to approximately 7 phospholipids/rhodopsin molecule and approximately 11 phospholipids/Ca2+-ATPase molecule, respectively.

Animals↗

Modeling systematic errors: polychromatic sources of Beer-Lambert deviations in HPLC/UV and nonchromatographic spectrophotometric assays.

It is well established that the use of polychromatic radiation in spectrophotometric assays leads to excursions from the Beer-Lambert limit. This Note models the resulting systematic error as a function of assay spectral width, slope of molecular extinction coefficient, and analyte concentration. The theoretical calculations are compared with recent experimental results; a parameter is introduced which can be used to estimate the magnitude of the systematic error in both chromatographic and nonchromatographic spectrophotometric assays. It is important to realize that the polychromatic radiation employed in common laboratory equipment can yield assay errors up to approximately 4%, even at absorption levels generally considered 'safe' (i.e. absorption <1). Thus careful consideration of instrumental spectral width, analyte concentration, and slope of molecular extinction coefficient is required to ensure robust analytical methods.

Chromatography, High Pressure Liquid↗

Homomeric and heteromeric ion channels formed from the kainate-type subunits GluR6 and KA2 have very small, but different, unitary conductances.

1. Patch-clamp methods were used to study recombinant glutamate receptor (GluR) ion channels expressed in human embryonic kidney cells (HEK 293) after transfection of the cells with cDNAs encoding kainate (KA)-type GluR subunits. Cells were transiently or stably transfected with the fully edited (R) version of GluR6 or they were contransfected with GluR6(R) and KA2. 2. Concentration-response data were obtained for KA and glutamate activation of homomeric GluR6(R) channels and fitted with Hill-type equations to give values for the agonist concentration at half-maximal activation (EC50), the Hill coefficient (nH), and the maximum current (Imax). Analysis of results obtained in seven cells with KA gave mean values of 0.47 microM and 1.47 for the EC50 and nH, respectively. The corresponding values for glutamate were 32 microM and 1.21 (n = 5). The Imax values obtained for KA and glutamate in the same cells were similar, suggesting that both KA and glutamate are full agonists at homomeric GluR6(R) channels. 3. Spectral density analysis of current noise evoked by KA and glutamate in GluR6(R)-expressing cells, or in outside-out patches from these cells, was used to obtain estimates of the apparent unitary conductance (gamma noise) of homomeric GluR6(R) channels. Results obtained with 10 microM KA in 15 cells gave a mean gamma noise value of 231 fS. The corresponding value from analysis of noise in outside-out patches was 259 fS (n = 4). Spectral density analysis of glutamate-evoked noise in six cells gave a mean gamma noise value of 264 fS. 4. Noise analysis of whole cell currents recorded in GluR6(R)/ KA2-expressing cell gave a mean gamma noise value of 572 fS (n = 9). Unlike homomeric GluR6(R) channels, GluR6(R)/KA2 heteromers were activated by alpha-amino-3-hydroxy-5-methyl-isoxazole-4-propionic acid (AMPA) (0.25-5 mM). The mean EC50 for KA activation of GluR6(R)/KA2 channels was 1.62 microM (n = 6). 5. The results indicate that both homomeric GluR6(R) and heteromieric GluR6(R)/KA2 channels have a unitary conductance in the femtosiemen range. The coassembly of KA2 with GluR6(R) results in channels that have a different affinity for AMPA and KA and a two- to threefold larger unitary conductance.

Cell Line↗

A comparison of noninvasive objective and subjective measurements of the optical density of human ocular media.

BACKGROUND: It is important for both researchers and clinicians to know the spectral composition of the light that reaches the retina. With this in mind, Johnson et al. developed a quick, objective instrument called the Lens Absorption Monitor (LAM) to measure the attenuation of light by the ocular media. Using a more refined method of measuring and correcting for scatter, we compared the results of the LAM against those with a subjective method utilizing a bipartite scotopic brightness-matching procedure (BIP). METHODS: We tested 41 healthy subjects (mean age, 35.9 years) with the LAM and BIP. RESULTS: Intereye correlation coefficients for the LAM were 0.70 at 410 nm and 0.83 at both 430 and 450 nm; for BIP, intereye correlation coefficients were 0.56 at 410 nm, 0.42 at 430 nm, and 0.38 at 450 nm. For optical density as a function of age, there was no statistically significant difference between the two instruments at 410 nm in either the slope (p > 0.43) or y intercept (p > 0.75). However, at both 430 and 450 nm, there was a significant difference in both slope (p < 0.001) and y intercept (p < 0.05) for the two instruments. CONCLUSIONS: With the latest refinements, LAM density measures correlated well with BIP estimates at 410 nm, but not at 430 or 450 nm. This underscores the fact that the LAM measures the spectral density of the anterior segment, whereas the BIP method is a measure of all the ocular media except for macular pigment. The difference between these two measures is consistent with the existence of a prereceptoral, presumably intraretinal, pigment (or pigments) located outside the anatomic fovea that absorbs light at short wavelengths.

Accommodation, Ocular↗

Human macular pigment assessed by imaging fundus reflectometry.

A computerized, television-based, imaging fundus reflectometer was used to obtain estimates of the spatial distribution of macular pigment (xanthophylls) from seven normal subjects. Digitized images of the bleached macula of each subject were acquired at illuminating wavelengths from 462 to 697 nm. An analysis of spectral reflectances indicated that differences in short-wavelength reflectance between the foveal center and parafovea were influenced by spatial variations in melanin and oxyhemoglobin absorption as well as by the distribution of macular pigment. To provide an estimate of the spatial distribution of macular pigment alone, we have corrected fundus images obtained at 462 nm for the effect of melanin and oxyhemoglobin absorption. The spatial variation in macular pigment double density across the horizontal and vertical meridians of the retina was well described by Gaussian functions. The peak double densities for the individual subjects ranged from 0.22 to 0.45 and the standard deviations of the Gaussian functions averaged approx. 1 degree.

Adult↗