Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “STEAM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files.

The purpose of this study was to determine whether heat sterilization adversely effects the torsional properties of rotary nickel-titanium files, making them more prone to fracture under torsional stress. Nine hundred sizes 2 through 10 Profile Series 29.04 taper files were divided into groups of 10 files each and sterilized 0, 1, 5, or 10 times in the steam autoclave, Statim autoclave, or dry heat sterilizer. Then, they were subjected to torsional testing in a Torquemeter Memocouple. Complete data were collected for sizes 2 through 7, but not for sizes 8 through 10 because their torque resistance exceeded the testing limits of the Torquemeter Memocouple. A one-way analysis of variance was used to compare all experimental groups in sizes 2 through 7 with their unsterilized controls (p < 0.05). Fifty-four comparisons were made for torsional strength and 54 for rotational flexibility. Ten significant changes occurred for torsional strength and 10 for rotational flexibility. Eight of 10 changes in torsional strength were increases. Fifty-two of 54 (96.3%) comparisons for torsional strength and 47 of 54 (87%) for rotational flexibility showed a significant increase or no change. Therefore, heat sterilization of rotary nickel-titanium files up to 10 times does not increase the likelihood of instrument fracture.

Analysis of Variance↗

The use of indicators for quality control of sterilizing processes in hospital practice: a review.

The development over the last 100 years of spore preparations to challenge sterilization processes using steam is reviewed briefly, and efforts to standardize such biological indicators (BIs) in the last 30 years are reviewed in more detail. A similar review of BIs for the ethylene oxide processes is presented with discussion of spore test resistances compared to the potential resistances of organisms commonly found as contaminants in the materials being sterilized. The development and need for quick-reading chemical indicators (CIs) that produce color changes only when exposed to moist heat or ethylene oxide plus moisture, as planned, are discussed. It is emphasized that BIs and CIs can only indicate that the sterilization process has worked as planned. They do not indicate that the materials being sterilized are completely sterile.

Cross Infection↗

Bizarre paediatric facial burns.

Child abuse and neglect account for a significant number of paediatric burn injuries. It is of great importance because of the high mortality, high frequency of repeated abuse, as well as the physical, psychological and social sequelae that it causes. Burn abuse is often under-recognized and under-reported because it is difficult to define non-accidental injury. On the other hand, false accusation of burn abuse is extremely damaging to the family. Bizarre and unusual burn injuries can be caused by accident and should not automatically be assumed to be deliberate injury. Three boys of age 1-7 years with bizarre facial burns were admitted to the Burns Unit at the Prince of Wales Hospital between February 1995 and July 1999. One was burned by his baby-sitter with hot water steam and the other two were burned by their mothers with hot boiled eggs. The unusual causes of their burns raised the suspicion of child abuse and formal investigations were carried out by the Social Services Department. Detail assessment including a developmental history of the child and the psychosocial assessment of the family revealed that these three boys were burned because of poor medical advice and innocent cultural belief.

Burns↗

Sterilization of orthodontic instruments and bands in cassettes.

The purpose of this study was to determine whether orthodontic instruments and bands contaminated with blood or saliva and bacterial spores can be heat sterilized while contained in OMS-ASAPsys instrument and band cassettes. Hinged and nonhinged instruments and bands were contaminated and dried, placed in the cassettes, ultrasonically cleaned, rinsed, and dried. The cassettes were wrapped and then processed through standard steam, chemical vapor, or dry-heat sterilizing cycles. Each instrument and band was then cultured for the presence of live spores. The results showed that the residual spores on the instruments and bands after ultrasonic cleaning and rinsing had indeed been killed in all cases. The three types of sterilization were equally effective. The results indicate that contaminated orthodontic instruments and bands can be sterilized within OMS-ASAPsys cassettes.

Blood↗

Effects of sterilization on the mechanical properties and the surface topography of nickel-titanium arch wires.

The effects of sterilization on the mechanical properties and the surface topography were determined on 0.017 x 0.025-inch Nitinol and Titanal arch wires. Three approved heat sterilization methods were used: dry heat, formaldehyde-alcohol vapor, and steam autoclave. Elastic moduli were obtained on 1-inch segments in 3-point bending. Laser scans of flatwise wire surfaces were conducted to detect surface alterations--whether they were caused by tarnish, corrosion, or pitting. Tensile properties were determined on 7-inch lengths: the 0.1% yield strength, the ultimate tensile strength, and the percent elongation at break. Within the confines of the present sterilization experiments, no detrimental changes were observed for either the selected mechanical properties or the surface topography. When the mean values of the two products were compared, Nitinol was less compliant but stronger than Titanal. Laser spectroscopy showed that Titanal possessed at least three times more specular reflectivity than Nitinol.

Alloys↗

A study of the spread of Campylobacter jejuni in four large kitchens.

Campylobacters were sought in swabs taken from work surfaces, sinks and floors of four kitchens-i.e. hospital, university, cook-freeze and commercial, processing frozen or fresh chickens. Each kitchen was visited on four occasions. In the large commercial kitchen environmental contamination was found on each visit, whereas campylobacters were isolated on six of the twelve visits to the other kitchens. The hands of operatives were contaminated with campylobacters on only two of the 45 swabs taken during processing. Cleaning with detergent and hot water (or steam) and drying appears to be sufficient to remove the organism from the environment. Evidence of carriage of campylobacters by the birds was obtained on all 16 visits. In the three kitchens where only frozen birds were used the organism was isolated from 30% and 9.8% of swabs taken from the internal and external surfaces respectively, while 41% of giblets and 22.2% of thawed juices yielded campylobacters. The external surface of 30 (88%) of 34 fresh birds grew campylobacters.

Animals↗

Coriander spice oil: effects of fruit crushing and distillation time on yield and composition.

Crushing intensity and distillation time were evaluated for their effects on the oil yield and composition of steam-distilled essential oil from fruits of Coriandrum sativum var. microcarpum L. A comparison of oils produced by laboratory- and pilot-scale stills showed that the two still types gave comparable yields and oil composition. The laboratory still was then used to compare oil yields and compositions from fruits crushed at three different intensities, at intervals during a distillation period of 60 min. Both crushing intensity and distillation time had significant (P< 0.05) effects on the yield and composition of the oil. The maximum oil yield was less from the light-crushed fruits, but the rate of oil recovery was significantly P < 0.05) higher. From the light-crushed fruits, 95% of the maximum yield was extracted in 22.5 min compared with 32 and 39 min for the standard and heavy-crushed fruits, respectively. The effect of crushing intensity on oil composition was most pronounced on the low-boiling-point a-pinene and on the higher-boiling-point geranyl acetate. Crushing had little effect on linalool content, but distillation time could be manipulated to alter the linalool content of the oil.

Acyclic Monoterpenes↗

The effect of mechanical cleaning and thermal disinfection on light intensity provided by fibrelight Macintosh laryngoscopes.

The increased use of thermal decontamination procedures for fibrelight laryngoscope blades, to comply with international guidelines, will have considerable economical effects. We evaluated the effect of mechanical cleaning plus thermal disinfection at 90 degrees C, with or without subsequent steam sterilisation at 134 degrees C, on light intensity provided by fibrelight laryngoscopes. After mounting the blades in a special frame with a built-in light source, light intensity was measured using radiometer/photometer. In total, 14 blades provided by 11 companies were tested. The majority of fibrelight laryngoscope blades were fairly resistant to the damaging effects of machine washing plus disinfection at 90 degrees C (mean [range] reduction in light intensity 34.6%[2.1-78.3%]). However, when exposed to an additional sterilisation procedure at 134 degrees C, the majority of blades were unable to withstand the combined treatment for 300 cycles (mean [range] reduction in light intensity 86.5%[32.0-98.7%]). This study stresses the need for fibrelight laryngoscope blades which are more resistant to thermal decontamination procedures than those available at present.

Disinfection↗

How to increase efficiency, safety and cost control in hospital infectious waste treatment.

An efficient and cost-effective on-site infectious waste management program can be implemented by integrating the decontamination advantages offered by both steam sterilization and incineration. To do so requires the understanding of the interrelationship between the components that comprise the program. The physical and chemical characteristics of the various infectious waste constituents will dictate the mode by which each constituent will be decontaminated. The treatment mode will in turn dictate the packaging and containment necessary to ensure decontamination. An understanding of the operating principles, and design features of each treatment mode will further enhance treatment efficacy.

Cost Control↗

Evaluation of recycled HDPE milk bottles for food applications.

The possibilities of recycling milk-contaminated HDPE were investigated. Bottles were blown of respectively untreated, caustic-washed and caustic-washed/steam-stripped/air-dried recycled material. The migration characteristics of the different bottles were compared using various food simulants, as well as their sensorial and mechanical properties. From the analytical and sensorial experiments, it was shown that the untreated and caustic-washed recycled material could not be considered as a food packaging material. A high number of compounds able to migrate were detected, causing an off-flavour which could easily be recognized. The steam-stripped recycled material however, seemed to perform almost as well as its corresponding virgin material. Only low amounts of compounds able to migrate could be detected, resulting in a packaging material characterized by excellent sensorial properties which could not be distinguished from its virgin material. Furthermore it was proved that the mechanical properties of the recycled material did not change during the recycling process.

Air↗

The acute effect of pulmonary burns on lung mechanics and gas exchange in the rabbit.

To determine the role of the thermal element in the production of lung injury uncomplicated by the inhalation of fumes and soot, 18 anaesthetized, paralysed and ventilated rabbits were subjected to a steam burn of the respiratory tract. Transpulmonary pressure (difference between airway and pleural pressure) was recorded under static conditions between functional residual capacity and 40 ml above this point and the values obtained were used to calculate lung compliance. Static compliance decreased progressively with time in each of the experimental animals, the maximum decrease occurring within the 1st hour. Ten of the 18 animals died within 4 hr of the burn. There was little impairment of gas exchange. This data would suggest the clinical value of the early measurement of lung compliance in the evaluation of thermal pulmonary burns. Postmortem studies showed the presence of pulmonary oedema with intra-alveolar peribronchial and perivascular haemorrhages. The lesions were most prominent centrally, apparently because the dissipation of the heat resulted in less damage to the peripheral areas of the lung. Pulmonary megakaryocytosis was noted in seven of the experimental animals. This may have been a non-specific reaction to lung trauma.

Animals↗

Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments.

AIM: To evaluate the effect of repeated sterilization cycles in dry oven or autoclave, on the mechanical behaviour and fatigue resistance of rotary endodontic Ni-Ti instruments. METHODOLOGY: New Ni-Ti instruments were subjected to five consecutive sterilization cycles in a dry oven or steam autoclave. Microhardness was measured in the nonmachined parts of the shanks of instruments using a Vickers indenter. Specimens of Ni-Ti wires were submitted to the same sterilization protocol and tensile tested until rupture. A group of instruments were fatigued to one half of their average fatigue life and then sterilized. New and sterilized instruments were fatigue tested until rupture. anova tests at alpha = 0.05 were used for statistical analysis. RESULTS: Sterilization procedures resulted in no significant changes in Vickers microhardness, nor in the parameters describing the mechanical behaviour of the wires. However, the number of cycles to failure was statistically higher for all instruments after dry heat or autoclave sterilization cycles. In the instruments previously fatigued to one half of their fatigue life, autoclave sterilization gave rise to an increase of 39% in the remaining number of cycles to failure. CONCLUSIONS: Changes in the mechanical properties of Ni-Ti endodontic instruments after five cycles of commonly used sterilization procedures were insignificant. The sterilization procedures are safe as they produced a significant increase in the fatigue resistance of the instruments.

Analysis of Variance↗

Food safety through the meat supply chain.

Food poisoning in humans can be caused by many different bacterial genera. While the incidence of food poisoning in England, Wales and Scotland from Salmonella has reached a plateau, there has been an increase in the incidence from Campylobacter. The incidence from Escherichia coli O157:H7 rose to 1997 but declined slightly in 1998 (data from the Public Health Laboratory Service and the Scottish Centre for Infection and Environmental Health). This organism has a high virulence in humans and a very low infective dose. Infection can produce a wide range of responses, including death. The low infective dose presents a major threat. The organism is relatively heat-sensitive and the cooking of food products to achieve a centre core temperature of 70 degrees C for 2 min is sufficient to destroy it. It is relatively acid-tolerant and will survive for several weeks at pH 4.2. Several foodstuffs, as well as water, have been implicated in world-wide outbreaks. The E. coli O157:H7 food-borne outbreak in Lanarkshire in 1996 led to 21 fatalities. The Pennington Group report, issued in April 1997, reported on the circumstances leading to this outbreak, the implications for food safety and the lessons to be learnt. Four areas covered within the Pennington Group report specific to meat hygiene are reviewed in this paper. On-farm practices must ensure the presentation of clean animals for slaughter. There is a requirement for the development and introduction of risk assessment techniques based upon Hazard Analysis of Critical Control Points in abattoirs, and the Meat and Livestock Commission (MLC) is producing a manual for use by the abattoir sector. The Pennington report stated that there was a need for research into the potential use of end-process treatments such as steam pasteurization. The MLC is involved in evaluating such a system. Meat production premises and butchers' shops in England are introducing HACCP through an MLC scheme funded by the Department of Health. At the point of consumption, food safety is improved by the provision of practical guidelines regarding the handling of meat and meat products. These are distributed at retail outlets and communicated to secondary schools via MLC's educational publications.

Abattoirs↗

Free and conjugated catecholamines in human plasma during physical exercise.

To investigate changes of free and sulfoconjugated catecholamines in response to alterations in sympatho-adrenal activity, free and conjugated noradrenaline, adrenaline and dopamine were determined radioenzymatically in plasma of 49 subjects. During brief vigorous bicycle exercise (8 min, maximal heart rate: 177 beats/min) mean free noradrenaline and adrenaline values of 2.0 and 0.51 nmol/l at rest, increased to 6.7 and 2 nmol/l (P less than 0.001) respectively, at the maximal workload of 200 watt, whereas conjugated noradrenaline and adrenaline decreased from 3.4 and 0.8 nmol/l to 2.1 and 0.4 nmol/l (P less than 0.001) respectively. In the tenth min of the recovery period basal free and conjugated noradrenaline and adrenaline levels were measured. The moderate stress of a steam bath (20 min, maximal heart rate: 131 beats/min) doubled free noradrenaline and adrenaline levels. However, conjugated noradrenaline and adrenaline concentrations remained unchanged. The increase in free catecholamine values during an exhausting cross-country march over 20 km was associated with an accumulation of sulfated catecholamines. After a rest of 30 min free noradrenaline and adrenaline reached basal values, whereas conjugated noradrenaline and adrenaline remained elevated by 64 and 70% respectively, compared to pre-exercise concentrations. It was concluded that conjugated noradrenaline and adrenaline may be used as pools for free noradrenaline and adrenaline during brief vigorous exercise. In addition, they may also be indicators of chronic activation of the sympatho-adrenal system.

Adult↗

Biomechanical evaluation of a crimp clamp system for loop fixation of monofilament nylon leader material used for stabilization of the canine stifle joint.

OBJECTIVE: To test a crimp clamp system designed to secure monofilament nylon leader (MNL) material commonly used as lateral fabellotibial sutures (LFS) in extra-articular stabilization of the canine stifle joint. STUDY DESIGN: In vitro biomechanical tests of MNL loops secured with either the crimp clamp system or knots were performed. Suture loops (n = 94) were created from 27.3 kg tensile strength MNL and fastened with knots or crimp clamps. Tests were conducted on steam-sterilized, ethylene-oxide-sterilized, and nonsterilized MNL sutures. Loops were evaluated in single load tests and cycled tests. Values for load to failure, initial loop tension, loop elongation, mode of failure, and point of failure were determined. RESULTS: Crimp-clamped loops were superior to knotted loops in all parameters tested in both cycled and noncycled tests. Loop failure generally occurred by breaking within 3 mm of the fixation in both clamped and knotted tests. Loop elongation after cycling was greater in the knotted loops compared with clamped loops (P < .001). Load to failure was greater in clamped tests than in knotted tests (P < .001), regardless of sterilization technique used. Significantly higher initial loop tension could be achieved with the clamp system compared with knot fixation (P < .001). CONCLUSIONS: The crimp clamp system provides superior in vitro loop fixation characteristics compared with knot fixation in 27.3 kg test MNL. CLINICAL RELEVANCE: Based on the results of biomechanical testing and the known biocompatibility of the system's implant components, clinical trials using the crimp clamp system are warranted.

Animals↗

Biochemical and in vivo properties of commercial virus-inactivated factor VIII concentrates.

The following commercial virus-inactivated factor VIII concentrates were studied in vitro: AHF-Kabi and Octonativ, KabiVitrum; Hemofil T, Hyland; Factorate HP and Monoclate, Armour; Nordiocto, Nordisk Gentofte (dry heated); Kryobulin TIM3, Immuno (steam treated); Profilate, Alpha (heated as dry material slammed in heptane); Hemate P, Behring (wet heated) and Octa-V.I., Octapharma (solvent/detergent treated). The concentration of VIII:C was lowest in AHF-Kabi, whereas it ranged from 24 to 53 IU/ml in the high purity concentrates, except for Monoclate in which it ranged from 91-128 IU/ml. All concentrates but Octa-V.I. had higher values for VIII:Ag than for VIII:C. von Willebrand factor with normal distribution of multimers could only be demonstrated in AHF-Kabi and Hemate P. In vivo studies were performed in 12 severe hemophiliacs. Recovery and half-life of VIII:C did not differ between the various concentrates. Hemate P was given to 5 patients with severe von Willebrand's disease, in all of whom a correction of the hemostatic defect was seen.

Antigens↗

An assessment of cross-infection control procedures among English-speaking Caribbean general dental practitioners. A regional preliminary study.

A survey was undertaken to assess the level of compliance with recommended infection control procedures among English-speaking Caribbean general dental practitioners. A four page questionnaire was sent to all practitioners in 18 English-speaking Caribbean islands. A response rate of 32 per cent was obtained. A large proportion of dentists followed the recommended barrier techniques particularly the use of gloves and facemasks. The most commonly available methods of sterilisation were steam autoclaves (82 per cent) and cold solutions (94 per cent). Seventy four per cent of respondents had received hepatitis B vaccination. A high percentage of dentists showed willingness to treat HBV (95 per cent) and HIV (84 per cent) carriers and this level of willingness to treat infectious patients has rarely been reported previously. There is an urgent need for further improvements to avoid getting inoculation injuries and splatters in the face or eyes with body fluids. Disposal of sharps and collection of solid waste are to be upgraded. The Caribbean Atlantic Regional Dental Association is planning to carry out similar research before the end of the year 2000.

Cross Infection↗

Power plants: effects of chlorination on estuarine primary production.

Steam electric stations may reduce primary production of cooling water by 91 percent as a result of chlorine applications for control of fouling organisms. Bacterial densities and concentrations of chlorophyll a are also reduced. Slight stimulation of production may occur in the absence of chlorination. Based on the available supply of "new" water, we calculate a maximum loss of primary production of 6.6 percent for the adjacent tidal segment of the Patuxent River.

Bacteria↗