Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prosthesis Coloring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

Further evidence of gaseous embolic material in patients with artificial heart valves.

OBJECTIVE: We undertook this study to evaluate the hypothesis that most microemboli signals in patients with artificial heart valves are gaseous, assuming that microemboli counts in cerebral arteries would progressively decline with increasing distance from the generating heart valve. METHODS: A total of 10 outpatients with CarboMedics (Sulzer Carbomedics Inc., n = 5) and ATS prosthetic heart valves (n = 5) in the aortic (n = 8), mitral (n = 1), or both aortic and mitral positions (n = 1) were recruited. Monitoring was performed simultaneously over the middle and anterior cerebral arteries and the common carotid artery for 30 minutes with the 2 MHZ transducers of a color duplex scanner (common carotid artery) and pulsed-wave Doppler ultrasonography (intracranial arteries). All data were harvested in an eight-channel digital audio tape recorder, and microembolic signal counts were evaluated online by two separate observers. RESULTS: Significantly higher microembolic signal counts were recorded in the common carotid artery (112 [75 to 175]) compared with the middle and anterior cerebral arteries (30 [18 to 36], p < 0.0001). Interobserver variability was satisfactory (k = 0.81). CONCLUSIONS: Our results strongly argue for gaseous underlying embolic material in patients with artificial heart valves because bubbles are bound to implode with time.

Adult↗

Early diagnosis of stuck Starr-Edwards disc valve in mitral position: inconstant and interrupted mitral regurgitation.

The patient was a 40-year-old man with Starr-Edwards disc valve for 21 years without symptoms. Newly developed systolic murmur at the apex was noticed at the monthly medical examination. Doppler color flow mapping indicated severe mitral regurgitation. However, the appearance of mitral regurgitation was not constant. Continuous wave Doppler recording indicated that some of the mitral regurgitations were abruptly terminated at early or mid systole with the disc closing signal. Mitral regurgitation was observed only at bradycardia and on the left lateral position. Cardiac surgery demonstrated no abnormality on the disc valve except small sulci on the rim of the disc. When the disc was tilted in the cage, it was stuck and did not move. Echocardiography was useful in detecting the early stage of stuck artificial valve that might be fatal in the mitral position.

Adult↗

Thrombotic and hemorrhagic complications in chronic myeloproliferative disorders.

Bleeding and thrombosis are major causes of morbidity and mortality in patients with chronic myeloproliferative disorders. We retrospectively evaluated 101 consecutive patients affected by primary thrombocytosis (46 male, 55 female, aged 18-84 years; mean +/- SD 61 +/- 15) followed for a period ranging from 6 months up to 10 years (median 5 years) at our hematological unit. At the time of diagnosis 48 patients were asymptomatic; 26 had clinical evidence of atherothrombosis (cerebral ischemic attacks, ischemic heart disease, peripheral occlusive arterial disease), ten had venous thrombosis, four experienced major hemorrhages, 23 presented microvascular ischemic manifestations namely erythromelalgia, paresthesias, acrocyanosis and dizziness. At presentation 51.2% of the patients had elevated serum lactic dehydrogenase, 34.5% hyperuricemia, and 23.4% serum creatinine > 1.2 mg/dL. Color Doppler ultrasound provided evidence of vascular stenosis or medium-intimal hyperplasia of epiaortic vessels in 48.9% of patients studied, and similar alterations of lower limb arteries in 23.8% of cases. Therapy modality included an antiplatelet agent (picotamide 300 mg/bid); a cytoreductive agent (busulphan, hydroxyurea, pipobroman or melphalan) was used when platelet count was > 800000/microL. Symptoms due to microvascular ischemia promptly regressed after picotamide and cytoreductive therapy. During follow-up. nine patients suffered from atherothrombotic events (transient ischemic attacks, ischemic stroke, unstable angina pectoris) and five developed deep vein thrombosis or superficial thrombophlebitis. Five patients experienced major hemorrhages (two melena, two hematuria, one perioperative bleeding); the two gastrointestinal hemorrhages occurred in patients self-medicated with non steroidal anti-inflammatory drugs, and the two episodes of hematuria occurred on oral anticoagulant therapy and aspirin respectively. No major bleeding occurred in patients on continuative therapy with picotamide, even in the presence of upper digestive tract disorders. Seven patients died: mortality resulted from one sudden coronary death, three solid neoplasia, one blast crisis, one anile, and one massive hemorrhage due to abdominal aortic prosthesis tearing. Our study suggests that a long-term antithrombotic prophylaxis with picotamide may be of benefit in patients affected by primary thrombocytosis; a controlled clinical trial is warranted to assess whether picotamide can ameliorate the natural history of the disease.

Adolescent↗

Effect of aortic valve replacement for aortic stenosis on severity of mitral regurgitation.

The severity of mitral regurgitation (MR) was determined by color Doppler echocardiography in 44 adult patients with severe symptomatic aortic stenosis before and after isolated aortic valve replacement. Preoperative MR was absent in 17, mild in 14, moderate in 11 and severe in 2 patients. Three to 388 (mean 58) days after surgery, 14 patients continued to have no MR. In the other 30 patients, MR decreased in 18 (60%), remained unchanged in 8 (27%) and increased in only 4 (13%). Furthermore, in 13 patients with significant (moderate or severe) MR, the severity decreased in 12 (92%). Thus, the severity of MR often decreases after aortic valve replacement for aortic stenosis.

Adult↗

A case of anaerobic abscessed hydroxyapatite orbital implants.

The purpose of this report is to document an unusual case of implant infection in a patient who had undergone enucleation and hydroxyapatite orbital implant surgery. A 32-year-old woman presented with chronic orbital discomfort and discharge following a history of hydroxyapatite orbital implant surgery at another hospital 4 years previous. She exhibited profuse discharge with a yellow, creamy color and marked conjunctival chemosis. Granulation tissue was noted on the central conjunctival surface. Following the removal of the conjunctival granulation tissue, a central 3x5 mm conjunctival dehiscence was present with exposure of the hydroxyapatite implant. A culture of purulent drainage emanating from the exposed implant showed a growth of Clostridium acetobutylicum. Removal of the orbital implant was done. The implant was noted to be filled with pus. This case suggests that anaerobic infection may be suspected when the granulation tissue is observed and a discharge with a foul odor is found.

Abscess↗

[Extensive indication of mitral valvuloplasty for non-rheumatic mitral regurgitation and postoperative QOL].

Between January 1993 and June 1996, 108 patients with non-rheumatic mitral regurgitation (MR) underwent surgical treatment. Mitral valvuloplasty (MVP) was performed in 94 patients (87%) and mitral valve replacement (MVR) was performed in 14 patients. The patients were reviewed based on the location of the prolapse, active endocarditis, and re-valvuloplasty. The proportion of MVP patients to the total number of cases was 92%, 96% and 94% for prolapse of the anterior mitral leaflet (MVP: n = 22), the posterior mitral leaflet (n = 47) and of both leaflets (n = 15), respectively; it was 60% and 33% in the patients with active infective endocarditis (n = 3) and in reoperation cases (n = 3). Reoperation was required in 2 patients. Other than reoperation cases, 3/4 grade MR was detected by color Doppler echocardiography in 6 patients although they were asymptomatic. Thromboembolism occurred in 3 patients. The event-free rate at 42 months was 80.4%. Concomitant maze procedure was performed in 36 of 39 patients with atrial fibrillation and normal sinus rhythm was obtained in 25 of the 36 patients. Only 6 patients received warfarin anticoagulation after MVP. In current cases with non-rheumatic MR, the MVP could be performed in 87% of all patients and in 94% of the patients with simple prolapse, regardless of the prolapse area. Concomitant maze procedure might provide a better quality of life after MVP.

Adult↗

[Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder: initial results and mid-term follow-up].

INTRODUCTION AND OBJECTIVES: Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and mid-term results of the treatment of PDA with the Amplatzer duct occluder. PATIENTS AND METHODS: From October 1999 to December 2001, 30 children underwent transcatheter closure of persistent ductus arteriosus at a mean SD age of 5 4.02 years (range: 3 months to 14 years) and weight of 20.3 10.3 kg (range: 4.5-45 kg). Infants under 10 kg weight made up 46% of total patients. A lateral view aortogram was made to determine the morphology of the ductus and select the size of the device. Occlusion was achieved using the anterograde venous approach. Follow-up evaluations were made with chest X-ray and echocardiogram at 24 hours and 1, 4 and 12 months after implantation. RESULTS: Twenty-eight patients (93.3%) immediately achieved complete occlusion, and on color Doppler examination the closure rate was 100% within 24 hours of implantation. There was no device embolization. In the follow-up, a 19-month-old patient developed a 20 mmHg gradient across the aortic arch. CONCLUSIONS: Patent ductus arteriosus can be easily occluded with the Amplatz Duct Occluder, which is effective and particularly useful in infants and children with relatively large PDA. Further experience and long-term follow-up are still needed to assess the safety of this device in smaller children.

Adolescent↗

A three-dimensional evaluation of a laser scanner and a touch-probe scanner.

STATEMENT OF PROBLEM: The fit of a dental restoration depends on quality throughout the entire manufacturing process. There is difficulty in assessing the surface topography of an object with a complex form, such as teeth, since there is no exact reference form. PURPOSE: The purpose of this study was to determine the repeatability and relative accuracy of 2 dental surface digitization devices. A computer-aided design (CAD) technique was used for evaluation to calculate and present the deviations 3-dimensionally. MATERIAL AND METHODS: Ten dies of teeth prepared for complete crowns were fabricated in presintered yttria-stabilized tetragonal zirconia (Y-TZP). The surfaces were digitized 3 times each with an optical or mechanical digitizer. The number of points in the point clouds from each reading were calculated and used as the CAD reference model (CRM). Alignments were performed by registration software that works by minimizing a distance criterion. In color-difference maps, the distribution of the discrepancies between the surfaces in the CRM and the 3-dimensional surface models was identified and located. RESULTS: The repeatability of both scanners was within 10 microm, based on SD and absolute mean values. The qualitative evaluation resulted in an even distribution of the deviations in the optical digitizer, whereas the dominating part of the surfaces in the mechanical digitizer showed no deviations. The relative accuracy of the 2 surface digitization devices was within +/- 6 microm, based on median values. CONCLUSION: The repeatability of the optical digitizer was comparable with the mechanical digitization device, and the relative accuracy was similar.

Computer-Aided Design↗

High-resolution computed tomography of temporal bone: Part IV: Coronal postoperative anatomy.

The purpose of this 4-part series is to illustrate the nuances of temporal bone anatomy using a high-resolution (200 micro isotropic) prototype volume computed tomography (CT) scanner. The normal anatomy in axial and coronal sections is depicted in the first and second parts. In this, the fourth part, and the third part, the structures that are removed and/or altered in 9 different surgical procedures are color coded and inscribed in the same coronal (article IV) and axial (article III) sections. The text stresses clinically important imaging features, including the normal postoperative appearance, and common complications after these operations. The superior resolution of the volume CT images is vital to the comprehensive and accurate representation of these operations. Minuscule intricate structures that are currently only localized in the mind's eye because of the resolution limit of conventional CT are clearly seen on these scans. This enhanced visualization, together with the information presented in the text, should assist in interpreting temporal bone scans, communicating with surgeons, and teaching this complex anatomy.

Cochlear Implantation↗

Replacement of the aortic root with a pulmonary autograft in children and young adults with aortic-valve disease.

BACKGROUND: The optimal substitute for severely diseased aortic valves in children and young adults is unknown. The use of a mechanical prosthesis requires permanent treatment of the patient with anticoagulants and is associated with thromboembolic and hemorrhagic complications. Aortic-valve allografts and porcine bioprostheses, which do not necessitate anticoagulant therapy, may deteriorate and have limited durability. METHODS: We therefore evaluated the use of the autologous pulmonary valve (i.e., the patient's own pulmonary valve) and the adjacent pulmonary artery as a replacement for the aortic valve and aortic sinuses in 33 patients. Five of the patients were from 8 to 16 years of age, and 28 were from 20 to 47 years of age. The pulmonary valve and the main pulmonary artery were used to replace the diseased aortic valve and the adjacent aorta. The coronary arteries were detached from the aorta and implanted into the pulmonary artery. The pulmonary valve and artery were replaced with a cryopreserved pulmonary allograft. RESULTS: There were no deaths during follow-up of up to 48 months (mean, 21 months). There were no episodes of infective endocarditis, and no reoperations on the aortic root were necessary. Also, there was no evidence on echocardiography of progressive dilatation of the autografts. With color-flow Doppler imaging, 22 patients were found to have only trivial regurgitation or none, 9 patients to have mild regurgitation, and no patients to have moderate or severe regurgitation across the autograft at the most recent follow-up visit. The mean peak velocity of flow across the autograft was 1.3 m per second (upper limit of normal, 1.8), indicating the absence of stenosis. One patient required reoperation for stenosis of the pulmonary allograft. CONCLUSIONS: Although the pulmonary-autograft procedure is more complex than simple aortic-valve replacement, it has been safely applied in selected patients, including young adults. Intermediate follow-up indicates satisfactory function of the autografts, with no dilatation or progressive valvular regurgitation. Pulmonary-root autografts may thus be the best available substitute for diseased aortic valves in children and young adults.

Adolescent↗

Construction of neoglans penis: a new sculpturing technique from rectus abdominis myofascial flap.

INTRODUCTION: Construction of a neoglans penis may be required following glans amputation at circumcision, strangulation by a hair coil, or self-mutilation, among other indications. It may also be combined with phalloplasty to imitate the natural appearance and to support a penile prosthesis. AIM: This is a report on a novel technique of neoglans construction for a patient with an amputated glans penis as a result of circumcision injury. METHODS: A rectus abdominis myofascial flap was used. The flap was designed to be a 12 x 4 cm segment of the infraumbilical portion of the muscle, based on the inferior epigastric vessels. The flap was harvested through a paramedian incision. The penis was partially degloved through a circumferential incision 1 cm below its summit. The distal penile skin was utilized to elongate the urethra, so that the urethral meatus would be at the tip of the neoglans. The flap was reflected and tunneled underneath the mons veneris and alongside the penis, to emerge distal to the summit of the penis. The flap was fashioned into the shape of a glans and secured in place around the neourethra. The impression of a corona was achieved by tucking the proximal edge of the flap to its undersurface. RESULT: Six months following surgery, the patient had a neoglans penis, a corona, and a urethral meatus at the very tip. The neoglans had similar consistency, color, and shape to the normal glans. CONCLUSION: Construction of a neoglans penis is possible using the described sculpturing techniques, with satisfactory cosmetic results.

Adult↗

Acetabular involvement in osteonecrosis of the femoral head.

When an arthroplasty is needed to treat osteonecrosis of the femoral head, the use of a component that replaces or resurfaces only the femoral head is often considered as an alternative to total hip replacement if the acetabulum appears radiographically normal. However, the long-term results of the use of endoprostheses have often been poor, secondary in part to progressive degeneration of the acetabular cartilage and to protrusio acetabuli. To help to explain these observations, we examined the acetabular cartilage in forty-one hips in which a primary total hip replacement had been performed because of osteonecrosis of the femoral head in association with a radiographically normal acetabulum. The cartilage in the superior, weight-bearing region of the acetabulum was grossly abnormal in forty of the forty-one hips and it was histologically abnormal in all thirty-three hips that were so evaluated. In all but one hip, gross degeneration of the cartilage was apparent, involving less than 20 percent of the acetabulum; the degeneration was graded as mild (superficial fibrillation and slight irregularity of the surface) in sixteen hips, moderate (moderate fibrillation, alteration in color and consistency, and thinning of cartilage without complete erosion to bone) in twenty hips, and severe (marked fibrillation, alteration in color and consistency, and marked thinning of cartilage with areas of complete erosion to bone) in four hips. These observations emphasize the fact that radiographs cannot demonstrate early degeneration of cartilage and that, by the time that an arthroplasty is needed, degenerative changes are already present in the acetabular cartilage of a high percentage of hips with osteonecrosis, even when radiographs of the acetabulum show no abnormalities. These findings should be kept in mind when a decision is being made regarding which type of arthroplasty should be done in a patient who has osteonecrosis of the femoral head and regarding when to do the procedure.

Acetabulum↗

Intra- and paraprosthetic valve regurgitation. A color Doppler echocardiographic study.

We prospectively followed a cohort of 64 patients bearing an aortic or mitral prosthetic valve (mean follow-up 5.2 +/- 3.2 months) in order to evaluate if color-coded two-dimensional Doppler echocardiography (CFD) could provide some major advantages with respect to pulsed (PW) and continuous wave (CW) Doppler in the diagnostic accuracy of detection of intra-, and paraprosthetic leaks. During follow-up 4 cases of pathologic prosthetic regurgitation ensued and were all correctly and easily identified by CFD while one of them was missed both by PW and CW Doppler. Based on our results we conclude that CFD is the best noninvasive tool actually available for the correct identification of prosthetic valvular regurgitation because it can provide useful accessory information difficult to obtain with other echocardiographic techniques.

Adult↗

[Percutaneous closure of interatrial defect using the buttoned double-disk prosthesis].

BACKGROUND: Surgical repair is the procedure of choice for atrial septal defect correction. Even though surgical mortality is low (< 1%), morbidity is significant (anesthesia, thoracotomy, cardiopulmonary bypass, longer hospitalization and intensive care unit monitoring). Transcatheter methods to occlude atrial septal defects have been in development during the last two decades. We report our experience in Italy with the Sideris buttoned double-disk device. METHODS: From March 1992 to April 1993, 14 patients aged 20 months to 52 years, weight 10 to 82 kg, underwent transcatheter atrial septal defect occlusion with the Sideris buttoned device. The buttoned device is a miniaturized two disk device introduced through small venous sheaths (8-9 F). The diameter of atrial septal defects by echocardiography varied between 9 and 23 mm, while the balloon stretched diameter of the defects varied between 13 and 24 mm. The devices selected were 19 +/- 4 mm larger than the stretched diameter of the defect, but less than the total length of the septum (33-56 mm) by echo. RESULTS: Pulmonary-to-systemic flow ratio varied between 1.5 to 4.0. Mean pulmonary artery pressure varied between 10 and 24 mmHg (mean value 17 +/- 3.5 mm Hg). The relationship between different atrial septal defect measurements (echo, shunt flow, stretched diameter) was statistically analysed: transthoracic echo diameter had a good correlation with the balloon stretched diameter (r = 0.63, p < 0.001). The atrial septal defect was occluded in 12 patients (86% success rate). There was one early "unbuttoning" which was surgically corrected with success. The other patient underwent surgical correction 3 months later because of unsuitability for transcatheter closure. Minimal residual shunt detected by color flow mapping at 1 month follow-up was seen in 4 patients (33%). No complications occurred in any of our patients. CONCLUSIONS: This initial experience with the Sideris buttoned double-disk device demonstrated that transcatheter closure of atrial septal defect is feasible and effective. It can be accomplished through small introducing sheaths. Further clinical trials are justified. This method could become the procedure of choice for the correction of small ASDs.

Adolescent↗

Management of valvular heart disease: an illustrative cases approach.

As indicated by the 22 illustrative cases included in this monograph, a stepwise approach to the assessment of valvular heart disease provides the information necessary to make good clinical decisions. The ECG and chest x-ray add useful information to the history and physical examination. Echocardiography, Doppler, and color flow Doppler techniques have an important role in defining the presence and severity of valvular stenosis and regurgitation. Nuclear techniques provide useful information about global biventricular systolic function, regional wall motion, and myocardial perfusion. Exercise testing is most valuable in confirming objectively the patient's functional status and exercise tolerance. Newer imaging techniques, such as cine CT and MRI, are capable of displaying and measuring cardiac chamber size and myocardial thickness; however, visualization of the cardiac valves and demonstration of flow abnormalities are difficult, limiting the current usefulness of these techniques in patients with valvular heart disease.

Adult↗

Comparison of implantation techniques using freestyle stentless porcine aortic valve.

Stentless porcine aortic valves demonstrate superior hemodynamic performance when compared with their stented counterparts. The technical considerations for implanting these valves can be demanding. The Medtronic Freestyle aortic root bioprosthesis resembles an allograft, has zero-pressure-fixed leaflets treated with an antimineralization agent, and can be implanted using a variety of techniques. In this study of that valve, total root replacement (TRR) was compared with a partial scallop aortic inclusion technique (PSI). Implications were performed in 75 patients (49 PSI and 26 TRR). There were no significant differences with respect to age, sex, or incidence of concomitant procedures. Mean aortic cross-clamp times were significantly less in the PSI group than in the TRR group (51.8 +/- 11.7 minutes versus 125.5 +/- 19.7 minutes; p = 0.0001). At discharge, mean systolic gradients seen on color-flow Doppler echocardiography were less in the TRR group than in the PSI group (6.17 +/- 3.66 versus 10.01 +/- 4.83 mm Hg; p = 0.014). Discharge echocardiography revealed trivial valve regurgitation in 8.3% of the TRR group and in 41.7% of the PSI group (p = 0.004). No patient experienced any significant valvular regurgitation on discharge echocardiography. We conclude that early experience with the Medtronic Freestyle aortic root bioprosthesis shows excellent short-term function regardless of implantation technique. Shorter cross-clamp times, comparable with those of stented valve procedures, occurred with PSI implantation. We anticipate that effects on long-term durability will be beneficial.

Adult↗

Intraoperative transesophageal echo-Doppler evaluation of stentless aortic xenografts. Incidence and significance of moderate gradients.

BACKGROUND: The aim of this study was to assess the utility of intraoperative transesophageal echocardiography (TEE) in the evaluation of patients undergoing aortic valve replacement with the CryoLife-O'Brien (CLOB) Stentless Porcine Aortic Bioprosthesis. METHODS: Between May 1994 and March 1995, 26 patients (15 men, mean age 68.4+/-10.78 years) had a CLOB valve in the aortic position. Transprosthetic gradients and valve regurgitation were detected by intraoperative TEE. Prosthetic regurgitation and transvalvular gradients were evaluated at six-month intervals using transthoracic echo-Doppler (TTE). RESULTS: The majority of implants resulted in low gradients (83.7%), with only four patients exhibiting a moderate gradient (15.3%). Color flow Doppler imaging showed central aortic regurgitation in only four of 25 patients (trivial, n=4; mild, n=1). There was one paravalvular leak (trivial, n=1). At follow-up examination (mean 37+/-12 months), 24 of 25 patients exhibited low mean gradients (7.25+/-2.81 mmHg). At follow-up one patient who had low velocities in the LVOT at perioperative evaluation exibited a moderate gradient (45 mmHg) with an effective orifice area of 0.8-0.9 cm(2). CONCLUSIONS: Intraoperative TEE was effective in assessing prosthetic stentless valve function.

Aged↗

Assessment of valve disease: qualitative and quantitative.

Evaluation of valve disease has changed significantly with the development of color Doppler echocardiography. Nevertheless, this technique has limitations, particularly in the assessment of valvular regurgitation. MR imaging, with its ability to provide three-dimensional morphologic data, dynamic cine information, and functional evaluation with flow-sensitive techniques, can be envisioned as a complementary noninvasive modality, able to provide the complete information required for planning therapeutic options. With MR imaging, qualitative as well as accurate and reproducible quantitative information such as volume measurements, cardiac function, and flow velocity profiles are unique for the evaluation of the severity of valve disease. This article reviews the different MR imaging techniques used in assessing valvular heart disease and discusses the advantages and limitations of these techniques in current clinical applications in comparison with classical imaging methods.

Heart Valve Diseases↗