Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Optical Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

Broadband modulation of light by using an electro-optic polymer.

A major challenge to increasing bandwidth in optical telecommunications is to encode electronic signals onto a lightwave carrier by modulating the light up to very fast rates. Polymer electro-optic materials have the necessary properties to function in photonic devices beyond the 40-GHz bandwidth currently available. An appropriate choice of polymers is shown to effectively eliminate the factors contributing to an optical modulator's decay in the high-frequency response. The resulting device modulates light with a bandwidth of 150 to 200 GHz and produces detectable modulation signal at 1.6 THz. These rates are faster than anticipated bandwidth requirements for the foreseeable future.

Journal Article↗

Coherent properties of a two-level system based on a quantum-dot photodiode.

Present-day information technology is based mainly on incoherent processes in conventional semiconductor devices. To realize concepts for future quantum information technologies, which are based on coherent phenomena, a new type of 'hardware' is required. Semiconductor quantum dots are promising candidates for the basic device units for quantum information processing. One approach is to exploit optical excitations (excitons) in quantum dots. It has already been demonstrated that coherent manipulation between two excitonic energy levels--via so-called Rabi oscillations--can be achieved in single quantum dots by applying electromagnetic fields. Here we make use of this effect by placing an InGaAs quantum dot in a photodiode, which essentially connects it to an electric circuit. We demonstrate that coherent optical excitations in the quantum-dot two-level system can be converted into deterministic photocurrents. For optical excitation with so-called pi-pulses, which completely invert the two-level system, the current is given by I = fe, where f is the repetition frequency of the experiment and e is the elementary charge. We find that this device can function as an optically triggered single-electron turnstile.

Journal Article↗

Ultrafast all-optical modulation on a silicon chip.

We experimentally demonstrate ultrafast all-optical modulation using a micrometer-sized silicon photonic integrated device. The device transmission is strongly modulated by photoexcited carriers generated by low-energy pump pulses. A p-i-n junction is integrated on the structure to permit control of the generated carrier lifetimes. When the junction is reverse biased, carriers are extracted from the device in a time as short as 50 ps, permitting greater than 5 Gbit/s modulation of optical signals on a silicon chip.

Journal Article↗

Detection of dual-gene expression in arteries using an optical imaging method.

We evaluate the in vivo use of an optical imaging method to detect the vascular expression of green fluorescent protein (GFP) or red fluorescent protein (RFP), and to detect the simultaneous expression of GFP and RFP after transduction into arteries by a dual-promoter lentiviral vector driving their concurrent expression. This method involves using a charge-coupled device camera to detect fluorescence, a fiber optic probe to transmit light, and optical filters to distinguish each marker. In animal models, these vectors are locally delivered to target arteries, whereas the gene for a nonfluorescent cell-surface protein is transduced into contralateral arteries as the sham control. The images show distinct areas of bright fluorescence from GFP and RFP along the target arteries on excitation; no exogenous fluorescence is observed in the controls. Measured signal intensities from arteries transduced with the single- and dual-promoter vectors exceed the autofluorescence signal from the controls. Transgene expression of GFP and RFP in vivo is confirmed with confocal microscopy. We demonstrate the use of an optical imaging method to concurrently detect two distinct fluorescent proteins, potentially permitting the expression of multiple transgenes and their localization in the vasculature to be monitored.

Animals↗

X-ray imaging with amorphous selenium: theoretical feasibility of the liquid crystal light valve for radiography.

A novel radiographic imaging system based on a liquid crystal light valve is described. A liquid crystal light valve is a photon addressed spatial light modulator that consists of a high resolution, solid-state electrostatic detector (photoconductor) and an electro-optic light modulator (liquid crystal cell) physically coupled in a sandwich structure. We propose a light valve with a thick, x-ray sensitive photoconductive layer and call the system under study the x-ray light valve (XLV). The image formation in the XLV is based on x-ray exposure controlled modulation of light from an external source; the XLV is essentially an x-ray image intensifier that allows the image brightness to be adjusted independently from the x-ray exposure. Thus the XLV may be coupled to an optical imager, such as a charge coupled device (CCD), for image digitization without a secondary quantum sink. A model of the XLV operation is developed to investigate its sensitivity, speed, noise, and resolution. The imaging properties of the XLV are found to be time dependent, which leads to an unusual transmission versus exposure characteristic. The feasibility of clinical use of the XLV based on amorphous selenium (a-Se) photoconductor and a twisted nematic liquid crystal cell is analyzed, and the device is shown to be adaptable to a variety of radiographic imaging tasks.

Biophysical Phenomena↗

Phase-locked widely tunable optical single-frequency generator based on a femtosecond comb.

We present an arbitrary optical single-frequency generator based on a femtosecond optical frequency comb. The functions of this device are comparable to those of a radio-frequency synthesizer. However, this device operates at hundreds of terahertz. The absolute frequency accuracy of this synthesizer is approximately 1 kHz at a 282 THz carrier frequency. The stability is approximately 2 x 10(-14) at 100 s, and the tuning speed exceeds 30 GHz/s. This source demonstrates the integration of a phase-locked optical comb into a versatile and easy-to-use system for the generation of tunable, absolute optical frequencies. By using downconversion, one could generate tunable terahertz frequencies that are phase locked to a microwave reference, such as a Cs atomic clock, and high-precision interferometry could benefit greatly from the stability and accuracy of this widely tunable source.

Journal Article↗

[A study of the necessity of cooling of charge-coupled devices in x-ray imaging systems].

The goal of this work was to study one of the widely used X-ray imaging systems: luminescent screen-optical system-matrix of photosensitive charge-coupled device (CCD)-amplifier-analog-to-digital converter. Experimental and theoretical studies were performed to substantiate the necessity of cooling of charge-coupled devices for improvement of X-ray image characteristics. The obtained results reveal the necessity of cooling of CCD-matrix crystals in the X-ray imaging system under consideration.

Cold Temperature↗

Volume relaxation in polymers and its effect on waveguide applications.

Volume relaxation in polymers and the effect intrinsic to glassy polymers can significantly affect their refractive index over time. Its beta rate has been found to be related only to relaxation temperature T and the glass transition temperature of the polymer Tg and not to the polymeric chemical structure. Universal values of beta have been obtained for polymers and were used to predict the minimum index change related to volume in polymers. The index change is in the range from 7.86 x 10(-5) to 5.26 x 10(-4) when the Tg - T value of polymers is between 90 and 350 degrees C. These volume-relaxation-induced changes can cause serious deterioration or even failure in corresponding polymer waveguide devices, such as arrayed waveguide gratings and variable optical attenuators, when the Tg of a polymer is not sufficiently high. A minimum requirement is therefore suggested for the Tg of polymers used to fabricate waveguide devices.

Journal Article↗

[Quality improvement of the medical images in digital and optoelectronic devices].

The realization of image processing algorithms in a hybrid optoelectronic device is discussed. The linear part of the algorithm is carried out in the optical block, and the nonlinear part of the algorithm in the electronic processing block of the device. These studies indicate the expediency of using the optical methods for processing the images of medico-biological objects to facilitate their visual analysis.

Analog-Digital Conversion↗

Design of computer-generated hologram with ring focus for nonmechanical corneal trephination with Er:YAG laser in penetrating keratoplasty.

PURPOSE: To calculate a beam-shaping optical element for homogeneous intensity distribution within a focal ring to be used in nonmechanical trephination with the Er:YAG laser in penetrating keratoplasty instead of a spot guiding device. METHODS: The phase distribution behind a holographic optical element (HOE) k psi(u) can be described by the addition of the hologram phase phiH(u) to the beam phase phiE(u): k psi(u) = phiH(u) + phiE(u), k = 2pi/lambda, where u denotes the coordinates inside the hologram aperture, k an integer, and lambda the laser wavelength. To avoid discontinuous wavefronts leading to speckle noise, a smooth phase function is necessary. After transforming the hologram aperture coordinates into the focal plane x in a focal distance f, psi can be retrieved from the slope equation: inverted delta psi(u) = x(u) - u/f. RESULTS: Creating a ring focus can be reduced to an essentially one-dimensional problem by separation of variables due to the symmetry condition. We calculated a computer-generated eight-level phase-only HOE with 4096 x 4096 pixels from a Gaussian-distributed 2.94 Er:YAG laser spot with a beam diameter of 10 mm and a focal distance of 100 mm. Thereby, a ring focus with an inner/outer radius of 7/8 mm can be created. To avoid Poisson's spo, the symmetry of the problem was broken by circular modulation of the phase leading to a spiral-like structure. The calculated efficiency of the HOE relating the energy within the ring to the total energy was 91%. CONCLUSION: With an HOE it is possible to redistribute the energy along the desired focal ring. The HOE design can be adapted to the intensity distribution of the impinging laser beam with its characteristic aperture shape. A circular homogeneous corneal trephination depth is possible, because the energy fluctuation from pulse to pulse does not locally affect the ablation process. A ring focus for the Er:YAG laser has the potential to render superfluous a manual beam control via micromanipulator and to allow a more rapid and more regular corneal trephination along aperture masks.

Cornea↗

Two-spatial-mode parametric amplifier in lithium niobate waveguides with asymmetric Y junctions.

For optical parametric amplifiers in proton-exchange waveguide devices reported to date, both the signal and the idler photons are in the TM00 mode, causing difficulty in distinguishing signal from idler. We report a two-mode optical parametric amplifier. The key components, asymmetric Y junctions, successfully launch the pump wave in a pure TM10 mode and separate the signal and the idler in the TM10 and TM00 modes with a power ratio of as much as 27.5 dB. With high parametric gain, optical parametric generation with a threshold of 300 pJ/pulse was demonstrated for 1.8 ps long pump pulses near 780 nm. These periodically poled lithium niobate waveguides are efficient integrable photon sources.

Journal Article↗

Model for deriving the optical performance of the myopic eye corrected with an intracorneal ring.

BACKGROUND: The intracorneal ring has been advanced as a mechanical device for the correction of myopia. The device may reduce refractive error, but the effect on the overall optical performance of the eye has been neglected. This paper addresses this issue by presenting mathematical models that will predict the effect of the intracorneal ring on refractive error, corneal asphericity, and the spherical aberration of the eye. MATERIALS AND METHODS: Algorithms are derived for predicting the corneal apical radius, asphericity, and the change in myopia after inserting intracorneal rings of any thickness and diameter. RESULTS: The model predicts that the magnitude of myopia reduction is a function of both ring thickness and diameter. The large diameter (9 to 10 mm), thin (0.1 to 0.2 mm) intracorneal ring is less likely to adversely affect corneal asphericity and therefore not significantly enhance the spherical aberration of the eye. CONCLUSIONS: An intracorneal ring cannot correct more than 4.00 diopters (D) of myopia without significantly increasing ocular spherical aberration, which, in turn, will compromise the final visual outcome.

Algorithms↗

Theory and experiments of a tunable wavelength-selective photodetector based on a taper cavity.

We demonstrate a wavelength-selective photodetector that combines a Fabry-Perot filtering cavity (FPC) with a taper absorption cavity (TAC). The taper cavity shows a nonresonant effect but exhibits an absorption enhancement effect, so that high speed, high quantum efficiency, wide tuning range, and an ultranarrow spectral linewidth can be achieved simultaneously. Device performance was theoretically investigated by including key factors such as taper angle, finite-size diffracting-beam input, and lateral walk-off in the taper cavity. The device was fabricated by bonding a GaAs-based FPC, which can be tuned via thermal-optic effect, with an InP-based TAC. An integrated device with a spectral linewidth of 0.6 nm (FWHM), a wavelength tuning range of 10.2 nm(1518.0-1528.2 nm), a 3 dB bandwidth of 12 GHz, and a quantum efficiency of approximately 70% was demonstrated, and the absorption layer thickness is only 0.3 microm.

Journal Article↗

Optical emission from a charge-tunable quantum ring

Quantum dots or rings are artificial nanometre-sized clusters that confine electrons in all three directions. They can be fabricated in a semiconductor system by embedding an island of low-bandgap material in a sea of material with a higher bandgap. Quantum dots are often referred to as artificial atoms because, when filled sequentially with electrons, the charging energies are pronounced for particular electron numbers; this is analogous to Hund's rules in atomic physics. But semiconductors also have a valence band with strong optical transitions to the conduction band. These transitions are the basis for the application of quantum dots as laser emitters, storage devices and fluorescence markers. Here we report how the optical emission (photoluminescence) of a single quantum ring changes as electrons are added one-by-one. We find that the emission energy changes abruptly whenever an electron is added to the artificial atom, and that the sizes of the jumps reveal a shell structure.

Journal Article↗

Concept of a miniature optical spectrometer using integrated optical and micro-optical components.

We describe the concept of a super compact diffractive imaging spectrometer, with optical components a few millimeters across in all dimensions, capable of detecting optical fluorescence spectra within the entire visible spectral range from 400 nm to 700 nm with resolution of the order of 2 nm. In addition, the proposed spectrometer is capable of working simultaneously with multiple, up to 35, independent input optical channels. A specially designed diffractive optical element integrated with a planar optical waveguide is the key component of the proposed device. In the preliminary experimental tests, a uniform waveguide grating with a microlens was used to mimic operation of the diffractive optical element. A microspectrometer with optical components measured below 1 cm in all dimensions covers the spectral range from 450 nm to 650 nm and shows a spectral resolution of 0.5 nm at wavelengths close to 514 nm and 633 nm.

Journal Article↗

Sampling field sensor with anisotropic fan-out.

We describe a new common-path, phase-shift, and shearing interferometric device capable of single-shot detection of optical phase profiles. It samples the input field and uses birefringent plates to fan out phase-shifted copies of the samples in the empty space between them. The phase shifts are given by the thickness of the plates and not by the relative position of the components, as in classical interferometers. This makes the device insensitive to vibrations. We recorded repeatability better than lambda/100, even though strong shocks were applied to the air table in proximity to the system. We recorded better than lambda/1000 repeatability under quiet conditions and estimated the accuracy to be better than lambda/3000 at the shot-noise limit. In addition, the device is compact and easy to integrate in a variety of setups that require the measurement of optical phase profiles.

Journal Article↗

Ultrafast random-access scanning in two-photon microscopy using acousto-optic deflectors.

Two-photon scanning microscopy (TPSM) is a powerful tool for imaging deep inside living tissues with sub-cellular resolution. The temporal resolution of TPSM is however strongly limited by the galvanometric mirrors used to steer the laser beam. Fast physiological events can therefore only be followed by scanning repeatedly a single line within the field of view. Because acousto-optic deflectors (AODs) are non-mechanical devices, they allow access at any point within the field of view on a microsecond time scale and are therefore excellent candidates to improve the temporal resolution of TPSM. However, the use of AOD-based scanners with femtosecond pulses raises several technical difficulties. In this paper, we describe an all-digital TPSM setup based on two crossed AODs. It includes in particular an acousto-optic modulator (AOM) placed at 45 degrees with respect to the AODs to pre-compensate for the large spatial distortions of femtosecond pulses occurring in the AODs, in order to optimize the spatial resolution and the fluorescence excitation. Our setup allows recording from freely selectable point-of-interest at high speed (1kHz). By maximizing the time spent on points of interest, random-access TPSM (RA-TPSM) constitutes a promising method for multiunit recordings with millisecond resolution in biological tissues.

Action Potentials↗

Fluorescence detection system for capillary separations utilizing a liquid core waveguide with an optical fibre-coupled compact spectrometer.

A fluorescence detection system for capillary liquid separation methods is described. The system is based on a silica capillary coated with a low refractive index fluoropolymer Teflon AF that serves both as a separation channel and as a liquid core waveguide (LCW). A fibre-coupled laser excites separated analytes in a detection point and arising fluorescence is collected at one end of the LCW capillary into the other optical fibre which brings it to a compact charge-coupled device (CCD) array spectrometer installed in a desktop computer. No additional components such as focusing optics or filters are necessary. This system was used for detecting isoelectrically focused fluorescent low-molecular-mass pI (isoelectric point) markers and fluorescein isothiocyanate (FITC) labelled proteins. The ability of the system to acquire fluorescent spectra is also demonstrated.

Calibration↗