Credentialing of surgeons as interventionalists for carotid artery stenting: experience from the lead-in phase of CREST.

BACKGROUND: Credentialing of vascular surgeons to perform carotid artery stenting (CAS) continues to be a major issue confronting the specialty of Vascular Surgery. Cannulation of aortic arch branches, and placement of carotid antiembolic devices and stents constitute the major technical challenges to vascular surgeons becoming credentialed to perform CAS. The multicenter Carotid Revascularization Endarterectomy vs Stenting Trial (CREST), supported by the National Institute of Neurological Disorders and Stroke, National Institute of Health, reviews credentials of interventionalists, including surgeons, for the trial's "lead-in" phase of CAS to treat symptomatic (>50% stenosis) and asymptomatic (>70% stenosis). METHODS: Vascular surgeons requesting participation in CREST must have achieved basic interventional credentialing criteria as recommended by the Society of Vascular Surgery. Each interventionalist is asked to submit notes and narrative summaries from a series of 10 to 30 CAS procedures for review by a multi-specialty review committee before being approved to participate in CREST. Thereafter, during the lead-in phase of CREST, each approved interventionalist is asked to perform CAS procedures using the study devices in as many as 20 patients. In this interim report from the CREST lead-phase, the association of specialty of operator (vascular surgeon, neurosurgeon, other specialist) and periprocedural stroke and death rate was examined in patients undergoing CAS. In addition, current enrollment volume in the lead-in phase by specialty of the principal investigator was examined. RESULTS: Thirty-two of 134 (23.9%) CREST-credentialed interventionalists are vascular surgeons (n = 22; 16.4%) or neurosurgeons (n = 10; 7.5%). For events monitored through March 31, 2004, 789 patients had undergone CAS procedures performed by these 134 specialists. Thirty-day stroke and death rate was 4.6%, and myocardial infarction was observed in 1.1% of patients. Serious adverse events have not been clustered at individual institutions, and no significant differences have been observed between vascular surgeons or neurosurgeons and other credentialed specialists. CONCLUSIONS: Vascular surgeons with basic catheter and guide wire skills, particularly those who have incorporated diagnostic cerebral angiography into their practice, can be credentialed to perform CAS. Individuals or groups should devote a number of cases (n = 10-30 per surgeon) to CAS to accomplish this goal. Pending US Food and Drug Administration approval of devices and Center for Medicaid and Medicare Services reimbursement, institutional financial support for the performance of these procedures must be secured. The learning curve for CAS should not be considered so formidable as to discourage surgeons from adding these techniques of CAS to their procedural inventory.

Angioplasty, Balloon↗

Legislation to regulate medical devices.

The history of medical device regulation began with the need to rid the marketplace of bogus inventions which were either harmful in themselves or harmful because they delayed meaningful treatment of illness. Since World War II, sophistication in medical technology and development of electronic and other types of medical devices has created a new need for regulation of safety and performance of devices used to cure and mitigate disease in man. The 1938 amendments to the Food, Drug, and Cosmetic Act gave FDA authority over labeling and advertising of devices, enforceable only after devices were marketed. In 1969 a study by an HEW commission documented the need for further legislation. The commission recommended three categories of medical devices: those requiring premarket clearance or scientific review, those for which standards could be established to protect the public, and those which are generally recognized as safe and for which nor standards would be necessary. In 1974 the Senate unanimously approved Senator Kennedy's "Medical Device Amendments of 1973" legislation which fulfills the recommendations of the HEW commission report. The House of Representatives failed to pass their version of the legislation in the 93rd Congress. Senator Kennedy re-introduced the bill in the 94th Congress and it passed the Senate in April 1975. Representative Rogers re-introduced an amended bill. The bill is expected to become law in 1975.

Equipment and Supplies↗

Designing medical devices for conformance with harmonized standards: a case study of non-active implants.

The European Community's Medical Devices Directives represent an ambitious effort to streamline the regulation of medical devices within the European Economic Area, an area comprising more than 380 million people. In this, the second of two special reports, Jean A. Goggins uses a case study format to demonstrate the process that would be used to gain European approval for a hypothetical medical device. In the first report, appearing on page 284, Richard C. Fries and Mark D. Graber describe the Medical Devices Directives and their effect on the product-development process.

Biocompatible Materials↗

Achievement of normal sagittal plane alignment using a wedged carbon fiber reinforced polymer fusion cage in treatment of spondylolisthesis.

BACKGROUND CONTEXT: Previous clinical studies of interbody fusion cages have generally failed to report sagittal plane alignment. In some cases, parallel-sided cages have contributed to loss of lumbar lordosis. A wedged-shaped carbon-fiber-reinforced polymer (CFRP) cage implant filled with autologous bone was designed to allow surgeons to more easily achieve normal sagittal plane alignment in posterior lumbar interbody fusion (PLIF). PURPOSE: This study was conducted to test the safety and efficacy of the wedged CFRP cage and the ability of surgeons to achieve normal anatomic alignment using an implant of this shape. STUDY DESIGN/SETTING: The wedged CFRP cage with pedicle screw fixation was evaluated in the treatment of patients with spondylolisthesis in a 2-year prospective study performed at 12 centers under a Food and Drug Administration (FDA)-approved protocol PATIENT SAMPLE: Inclusion criteria included patients with isthmic or degenerative spondylolisthesis at a single level below L4 with a translational malalignment of 3 mm or greater. Exclusion criteria included patients with more than 90% translation, previous surgery or abnormalities at more than two levels. OUTCOME MEASURES: Traditional outcome measures have included clinical success (improvement in pain and function) and fusion success (proof of living bone bridging the fusion area). This study adds a more complete analysis of anatomic success (restoration or maintenance of normal disc space height and sagittal plane alignment). METHODS: A clinical study of PLIF with pedicle screw fixation included a prospective group of 46 patients treated for spondylolisthesis. This article presents the data from the FDA-approval protocol. RESULTS: Fusion success was achieved in 35 of 36 patients (97.2%) reaching the 2-year follow-up interval. Clinical success was achieved in 35 of 37 (94.6%), and overall success was achieved in 33 of 36 (91.2%). Disc space height averaged 8.3 mm preoperatively, was increased to 10.2 mm at surgery and was maintained at 9.8 mm at 2 years. L4-S1 sagittal plane alignment was maintained within normal range, averaging 30.6 degrees after surgery. Clinical and fusion success rates trended higher than previous results with the rectangular cage but were not statistically different. Fusion success was significantly better than prior literature for treatment of spondylolisthesis (p=.0160). Complications of the surgery trended lower but were not statistically different from the study of the rectangular cage. CONCLUSIONS: The wedged CFRP cage with pedicle screw fixation allows surgeons to maintain normal sagittal plane alignment. These devices are safe and effective for treatment of spondylolisthesis and are FDA approved in the United States.

Adult↗

European medical device regulatory law and product liability.

The regulatory system for medical devices is quite different from that for pharmaceuticals and may catch many people unawares. For instance, it does not involve the grant of a marketing authorization by a medicines agency. Instead, a declaration of conformity is made by the manufacturer, but in many instances this is subject to approval by an independent certification house (known as a notified body). The Medical Devices Directive 93/42/EEC is applied in each EEA State by national Legislation. In the UK, for example, the relevant law is the Medical Devices Regulations 1994, and responsibility for enforcement rests with the Medical Devices Agency. Non-compliance with the regulations can incur a criminal penalty.

Device Approval↗

Financial disclosures of scientific papers presented at the 2003 RSNA Annual Meeting: association with reporting of non-Food and Drug Administration-approved uses of industry products.

PURPOSE: To retrospectively characterize the extent and nature of financial relationships with industry that are disclosed in the abstracts of scientific papers presented at the 2003 Radiological Society of North America (RSNA) Annual Meeting and to retrospectively assess whether the presence of relationships between researchers and industry was associated with a discussion on the use of products or devices that are not yet approved by the U.S. Food and Drug Administration (FDA). MATERIALS AND METHODS: Printed abstracts of scientific papers published in the 2003 Radiological Society of North America Scientific Assembly and Annual Meeting Program were classified according to the number and type of financial relationships disclosed. Also recorded was whether the abstracts discussed non-FDA-approved use of a product. Abstracts with and those without disclosures were then compared by using the Fisher exact test with respect to the percentage of abstracts that reported non-FDA-approved use. RESULTS: Of the 1549 published abstracts, 271 (17%) disclosed at least one author with financial ties to a company whose products or services were reported. The most common disclosures were for authors who were employees (39%), corporate grant recipients (34%), corporate consultants (23%), or shareholders (18%) of the corporation whose product was studied. A total of 87 (32%) of 271 abstracts with disclosed corporate relationships discussed non-FDA-approved use of a commercial product compared with 197 (15%) of 1278 abstracts with no disclosed tie to industry (P<.001). CONCLUSION: RSNA abstracts in which authors disclosed corporate financial relationships were twice as likely as those without such disclosures to discuss non-FDA-approved use of a commercial product. This raises the possibility that corporate relationships may influence radiology research.

Conflict of Interest↗

Longer life span for Copper T 380 A.

Copper T 380 A, the intrauterine device (IUD), has now been clinically approved by the US Food and Drug Administration (FDA) to have a longer lifespan. According to a population council news release, the device, which originally had a 4-year term duration, has been found out to be effective for 6 years. The extension was based on data from a study conducted by the World Health Organization (WHO) and submitted to the FDA by the Population Council, developer of the IUD. This extension will undoubtedly have many advantages, as the less frequently the device is replaced, the fewer the risks of pelvic inflammatory disease, perforation, and other complications that occur mainly soon after insertion. More so, less frequent insertions will cost less and be more convenient. The president of the Population Council, Mr. George Zeidenstein, welcomed the FDA action and said "when we licensed Cynopharma (the sole distributors of the product) to introduce the Copper T 380A IUD in the US 3 years ago, we knew it was a superior, long-acting reversible method that would expand contraceptive options. The fact that this IUD is approved for 6 years makes it an even more attractive option for women choosing a contraceptive method."

Americas↗

Medical devices; reclassification and codification of suction lipoplasty system for aesthetic body contouring--FDA. Final rule.

The Food and Drug Administration (FDA) is announcing that it has issued an order in the form of a letter to the American Society for Aesthetic Plastic Surgery (ASAPS) reclassifying the suction lipoplasty system for use in aesthetic body contouring from class III (premarket approval) to class II (special controls). The reclassification is based on information regarding the device contained in a reclassification petition submitted by ASAPS and other publicly available information. Accordingly, the order is being codified in the Code of Federal Regulations. This action is taken under the Medical Device Amendments of 1976 (the 1976 amendments) as amended by the Safe Medical Devices Act of 190 (the SMDA).

Device Approval↗

Integrating the patient's perspective into device evaluation trials.

Innovations in medical device technology have greatly expanded the range of therapeutic options available to physicians and their patients. The understanding of treatment effects from the patient's perspective is an essential component of a comprehensive assessment of any new therapy, including medical devices. The term "patient-reported outcomes" (PROs) has been growing in use to refer to a cluster of variables such as health-related quality of life, symptoms, physical functioning, psychological well-being, treatment satisfaction, and treatment preferences. As in drug trials, the use of PROs in device evaluation has several methodological challenges, ranging from general concerns about interpretation, to more specific issues related to study design and regulatory approval (use of PROs as primary end points, incorporation in labeling, and product promotion). Successful approaches for integrating PROs into device evaluation trials include the careful selection of appropriate, interpretable PRO end points, accounting for possible confounding factors, and the use of alternatives to placebo-controlled trial designs, such as single-arm pre-post, observational, and registry studies, when the use of placebo control groups is not feasible. This article discusses the potential value and difficulties in measuring PROs in device studies.

Clinical Trials as Topic↗

Cardiovascular and neurological devices; reclassification of two embolization devices. Final rule.

The Food and Drug Administration (FDA) is issuing a final rule to reclassify two embolization device types from class III (premarket approval) into class II (special controls). The agency is also changing the names and revising the identifications of these devices. The vascular embolization device (previously the arterial embolization device) is intended to control hemorrhaging due to aneurysms, certain types of tumors, and arteriovenous malformations. The neurovascular embolization device (previously the artificial embolization device) is intended to permanently occlude blood flow to cerebral aneurysms and cerebral arteriovenous malformations. FDA is reclassifying these devices on its own initiative on the basis of new information. FDA is taking this action under the Federal Food, Drug, and Cosmetic Act (the act), as amended by the Medical Device Amendments of 1976 (the 1976 amendments), the Safe Medical Devices Act of 1990, the Food and Drug Administration Modernization Act of 1997, and the Medical Device User Fee and Modernization Act of 2002. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document that will serve as the special control for these devices.

Cardiology↗

Amotosalen: Allogeneic Cellular Immunotherapies system, INTERCEPT Plasma System, INTERCEPT Platelet System, S 59.

Adis CommentsCerus Corporation is developing a variety of pathogen-inactivation systems, based on its Helinx technology. Three of the systems include amotosalen [S 59] as the inactivation compound. Amotosalen is a light-activated, DNA-, RNA-crosslinking psoralen compound, which is used to neutralise pathogens. The systems that utilise amotosalen are called the INTERCEPT Platelet System, the INTERCEPT Plasma System and the Allogeneic Cellular Immunotherapies (ACIT) system. The INTERCEPT Platelet System and INTERCEPT Plasma System are two of the systems that make up Cerus' INTERCEPT Blood Systems. The other system is the INTERCEPT Red Blood Cell System, which contains S 303 as the inactivation compound rather than amotosalen. Cerus' Helinx technology is able to prevent replication of DNA or RNA that is present in pathogens but not in the blood components being treated (e.g. platelets and plasma). When added to the blood components, the inactivation agent (in this case amotosalen) crosses the membrane or cell wall of the pathogen. When activated by light, amotosalen binds to the nucleic acid of the pathogen and prevents replication. This process prevents infection. INTERCEPT Platelet System: Cerus developed its INTERCEPT Platelet System, in collaboration with Baxter Healthcare, for use in blood centres. Platelets are an essential component of the coagulation process and may be required by patients undergoing surgery, cancer chemotherapy, transplantation or with bleeding disorders. The system is made up of an illuminator device, a compound absorption device and a processing kit containing amotosalen. In October 2002, the two companies announced that CE Mark approval had been received for the illuminator device for the INTERCEPT trade mark Blood System. Application of this technology to platelets is the first to be approved. As it is a new technology, the system is currently undergoing process validation in accordance with European Blood Bank GMP requirements. This validation process is currently being conducted in Denmark, France, Germany, Sweden and the UK. Marketing approval applications for the INTERCEPT Platelet System have also been submitted in Australia and Canada. In addition, the regulatory submission process has begun in the US. A phase III trial (EuroSPRITE) has been conducted in 103 patients in Europe with pooled random donor platelets. The platelets were collected using the buffy coat process. Another two 20-patient clinical trials have also been conducted in Europe, as well as a 40-patient trial using platelets collected by an apheresis collection system. Cerus has also conducted a phase III trial (SPRINT) in the US. The trial was conducted in 671 patients and used platelets collected by Baxter's apheresis collection system. INTERCEPT Plasma System: Cerus is also developing the INTERCEPT Plasma System in collaboration with Baxter Healthcare. The system also combines amotosalen, an illumination device and a compound absorption device. The two companies are currently preparing regulatory applications for the INTERCEPT Plasma System for the US. This application will be followed by a submission for CE Mark designation in Europe. Patients undergoing surgery, or transplantation, or with bleeding disorders, may require transfusions of plasma, often to control bleeding. The type of plasma is stored in frozen form and is called fresh frozen plasma (FFP). The INTERCEPT Plasma System is currently in phase IIIc development in the US. Patient enrolment in the trial is still ongoing. The trial is comparing INTERCEPT trade mark Plasma System treated versus untreated FFP in 30 patients with thrombotic thrombocytopenic purpura. Allogeneic Cellular Immunotherapies system: Cerus is also investigating the potential of its Helinx technology to improve the outcome of bone marrow transplantation procedures (used to treat leukaemia and lymphoma) through the treatmatment for many forms of leukaemia and is most effective when the donor is very closely matched to the patient for the major human leucocyte antigen (HLA) groups. As part of the transplant procedure, patients receive donor T cells to improve engraftment of the bone marrow transplant and strengthen the patient's immune system. However, donor T cells expose the patient to a high risk of contracting graft-versus-host disease (GVHD) caused by the proliferation of donor T cells, which attack the patient's healthy tissue. GVHD has a high mortality rate. Cerus' ACIT system has been developed to decrease the stringency of matching donors to patients and to inhibit the ability of donor T cells to cause GVHD. Light-activated amotosalen binds and permanently crosslinks DNA, preventing replication and thus stopping proliferation of donor T cells. Phase I development is currently being conducted in this area in the US using amotosalen as the neutralising agent. Cerus completed a phase I study investigating the safety and tolerability of its ACIT system in 2001. The study was conducted in patients receiving closely matched allogeneic bone marrow transplants for leukaemia. The company is currently collaborating with the National Marrow Donor Program in order to conduct further clinical studies in patients receiving bone marrow transplants from unmatched donors. Cerus has development, manufacturing and marketing agreements with Baxter covering the INTERCEPT Blood Systems, which includes the INTERCEPT Platelet system, the INTERCEPT Plasma System, and the INTERCEPT Red Blood Cell System. Under the terms of the agreements the two companies usually share the very early development activities. Cerus then conducts preclinical and clinical trials, while Baxter is responsible for the development of the systems disposables and devices. Following commercialisation Cerus will supply amotosalen and Baxter will supply the other components of the system and market, sell and distribute the system In January 2001, Cereus announced that it has entered into a collaborative agreement with the Pharmaceutical Division of Kirin Brewery in Japan to develop and market products for stem cell transplantation based on Cerus' proprietary Helinx technology. Under terms of the agreement, Cerus and Kirin will jointly develop the products. Cerus has received an initial license fee of US dollar 1 million. In addition it may receive up to US dollar 11 million in future payments upon achievement of development milestones. Kirin will also fund all development expenses for the Asia-Pacific region and a portion of Cerus' development activities aimed at obtaining product approval in the US. Kirin will market the products in the Asia-Pacific region, including Japan, China, Korea and Australia, and Cerus will receive a specified share of product revenues. Cerus will retain marketing rights in the rest of the world, including the US and Europe.

Anti-Infective Agents↗

The drug-eluting stent information gap.

Drug-eluting stents are quickly replacing bare-metal stents as the arterial revascularization device of choice. Because nearly all the information we have about patient outcomes with drug-eluting stents is from trials designed for US Food and Drug Administration approval, we are missing some of the information critical to a more comprehensive understanding of how these new devices will perform at the population level.

Coated Materials, Biocompatible↗

Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: physiologic implications and their relationship to patient selection.

BACKGROUND: We have been investigating continuous-flow circulatory support devices for 20 years. Unlike pulsatile assist devices, continuous-flow pumps have a simplified pumping mechanism and they do not require compliance chambers or valves. In the 1980s, clinical experience with the Hemopump proved a high-speed, intravascular, continuous-flow pump could safely augment the circulation. Subsequently, a decade of animal experiments with a larger, longer-term continuous-flow pump (the Jarvik 2000) confirmed the safety and efficacy of intraventricular placement, leading to its clinical application. METHODS: We analyzed the physiologic and anatomic effect of using the Jarvik 2000 pump for cardiac support in 23 patients in whom the device was applied as a bridge to transplant under the protocol approved by the Food and Drug Administration Investigational Device Exemption. The device was used as a bridge to transplantation in 20 patients and as destination therapy in 3 patients. RESULTS: In the bridge-to-transplant group, 14 patients underwent transplantation, 5 died during the circulatory support period and 1 is in an ongoing study. The support period lasted an average of 90 days. For the survivors, the follow-up period has averaged 16 months. Within the first 48 postoperative hours, the average cardiac index increased by 65% (from 1.77 +/- 0.24 to 2.92 +/- 0.60 L. min(-1). m(-2), p = 0.00000002), the systemic vascular resistance decreased by 42% (from 1604 +/- 427 to 930 +/- 330 dynes/sec per cm(2), p = 0.00001), and the pulmonary capillary wedge pressure (PCWP) decreased by 41.8% (from 23 +/- 5.1 to 13.4 +/- 6.6 mm Hg, p = 0.00009). Similar results were seen for the patients undergoing destination therapy. Cardiac index increased 89.5% (from 1.9 +/- 0.1 to 3.6 +/- 0.6, p = 0.046) and PCWP decreased by 52.2% (from 23 +/- 10 to 11 +/- 2, p = 0.22). In that group, 1 patient died unexpectedly from an accident 382 days after device implantation. The 2 survivors remain in New York Heart Association (NYHA) functional class I at 700 to 952 days after implantation. CONCLUSIONS: The Jarvik 2000 can offer effective long-term support for patients with chronic heart failure and NYHA class IV status. However, the new physiology produced by continuous offloading of the heart throughout the cardiac cycle has introduced unique clinical problems. The understanding of the problems generated by this biotechnological interface is essential for obtaining optimal clinical outcomes.

Adult↗

Development of cardiovascular drugs: the U.S. regulatory milieu from the perspective of a participating nonregulator.

The Food and Drug Administration (FDA) is responsible for assuring that drugs, devices, and biologicals available in the U.S. are effective and acceptably safe for their intended uses. Both law and regulation define the procedures to be followed by the FDA in judging the effectiveness and safety of therapies. The FDA comprises a cadre of highly skilled public servants who receive and evaluate all data collected by the manufacturer during therapy, not just the portion that reaches publication. To assist in reaching final conclusions about approvability, the FDA can empanel legally constituted advisory committees and external consultants when the need is perceived for additional specific scientific/technical expertise and substantial experience in clinical practice. Evidentiary standards for marketing approval of drugs, biologicals, and devices generally require direct demonstration of clinical benefit, rather than inferences drawn from "surrogate" pharmacologic/device-mediated effects, sufficient exposure to enable a reasonable assessment of countervailing risk, consideration of specific design elements in the pivotal clinical trials (including prespecified hypotheses [implicitly incorporated in "primary end points"], rigorous plans for statistical analyses, and so on), and assessment of persistence of effectiveness and associated stability of safety over time. Finally, sufficient information must be available so that practitioners can receive written instructions for use (the label) adequate to support the likelihood that recipients of the therapy will receive the expected benefits within the envelope of the stated risks. This article will discuss and expand on these issues, with examples.

Cardiovascular Agents↗

The FDA's role in medical device clinical studies of human subjects.

This paper provides an overview of the United States Food and Drug Administration's (FDA) role as a regulatory agency in medical device clinical studies involving human subjects. The FDA's regulations and responsibilities are explained and the device application process discussed. The specific medical device regulatory authorities are described as they apply to the development and clinical study of retinal visual prosthetic devices. The FDA medical device regulations regarding clinical studies of human subjects are intended to safeguard the rights and safety of subjects. The data gathered in pre-approval clinical studies provide a basis of valid scientific evidence in order to demonstrate the safety and effectiveness of a medical device. The importance of a working understanding of applicable medical device regulations from the beginning of the device development project is emphasized particularly for novel, complex products such as implantable visual prosthetic devices.

Clinical Trials as Topic↗

Summary of safety and effectiveness data from FDA: a valuable source of information on the performance of global endometrial ablation devices.

OBJECTIVE: To provide an overview of the approved second-generation endometrial ablation technologies. STUDY DESIGN: Data from the FDA Summary of Safety and Effectiveness Data were compared for Thermachoice, HydroThermablator, Her Option and Novasure devices. RESULTS: At 12 months' follow-up, Novasure and HydroThermablator had the highest amenorrhea rates. Thermochoice and Novasure had the highest success rates at 12 months. Novasure had the lowest adverse event rates in the first 24 hours, between 24 hours and 2 weeks and between 2 weeks and 1 year of follow-up. CONCLUSION: Summary of Safety and Effectiveness Data, obtainable on the FDA Web site, offers objective data for comparing second-generation endometrial ablation technologies.

Amenorrhea↗

A fracture movement monitoring system to aid in the assessment of fracture healing in humans.

This paper presents a new design for a device to monitor the motion of fracture fragments in diaphyseal tibial fractures. The device measures the motion that occurs at the fracture site when loaded by gait or by manipulation. It has undergone rigorous calibration and acceptance trials. The device has been used in ethically approved research clinics held at the North Staffordshire Hospital (40 patients). The paper presents a selection of results obtained using the new device. The results demonstrate several new ways of assessing fracture healing by examining fracture site motion. The following conclusions were drawn: 1. If fracture monitoring devices are to be attached to bone screws, it is essential to minimize bone screw errors. To do this, each patient must have similar bone screw lengths, orientations, alignment and siting. This is only achievable using a peroperative reduction device. 2. If fracture stiffness is to be used as a measure of fracture healing, load rate should be controlled; at the very least strain rate should be controlled. 3. It is imperative that fracture stiffness be measured in more than one plane by a biplanar device so that asymmetry may be accommodated. 4. Fracture stiffness, on its own, is probably not a sufficiently rigorous measure of healing end-point. The quantifiably viscoelastic properties of healing callus should be taken into account.

Bone Screws↗