Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compression Algorithms”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88Linked to original sources

Feasibility of automated matching of supine and prone CT-colonography examinations.

Matching of prone and supine positions in CT colonography may improve accuracy of polyp detection. The purpose of this study was to investigate the feasibility of automatic prone-supine matching in CT-colonography using proven polyps as fixed points of reference. The method is based on similarities in the direction of centre-lines and allows for compression and extraction of the centre-lines in both positions. To illustrate the impact of the match error of the new method in practice, the visibility of the matched polyps in a primary three-dimensional unfolded cube setting was determined as well. The method was compared with a method that relies on the normalized distance along the centre-line (NDAC method). The median absolute match error was 14 mm (range 0-59 mm, average 20 mm) either proximal or distal from the actual polyp in prone position. In the observer study, 70% (26/37) of the polyps were directly visible in prone view. The overall difference in median absolute match error between both methods was small (2 mm), although half way along the centre-line there were polyps with substantial differences in match error (larger with NDAC). We concluded that automated prone-supine matching of CT-colonography studies is feasible and has a low match error. The difference with the NDAC method was small and not significant, although half way along the centre-line some differences were seen.

Algorithms↗

Wavelet-based ECG compression using dynamic vector quantization with tree codevectors in single codebook.

In this paper, we propose a novel vector quantizer (VQ) in the wavelet domain for the compression of electrocardiogram (ECG) signals. A vector called tree vector (TV) is formed first in a novel structure, where wavelet transformed (WT) coefficients in the vector are arranged in the order of a hierarchical tree. Then, the TVs extracted from various WT subbands are collected in one single codebook. This feature is an advantage over traditional WT-VQ methods, where multiple codebooks are needed and are usually designed separately because numerical ranges of coefficient values in various WT subbands are quite different. Finally, a distortion-constrained codebook replenishment mechanism is incorporated into the VQ, where codevectors can be updated dynamically, to guarantee reliable quality of reconstructed ECG waveforms. With the proposed approach both visual quality and the objective quality in terms of the percent of root-mean-square difference (PRD) are excellent even in a very low bit rate. For the entire 48 records of Lead II ECG data in the MIT/BIH database, an average PRD of 7.3% at 146 b/s is obtained. For the same test data under consideration, the proposed method outperforms many recently published ones, including the best one known as the set partitioning in hierarchical trees.

Algorithms↗

Elastographic image quality vs. tissue motion in vivo.

Elastography is a noninvasive method of imaging tissue elasticity using standard ultrasound equipment. In conventional elastography, axial strain elastograms are generated by cross-correlating pre- and postcompression digitized radio frequency (RF) echo frames acquired from the tissue before and after a small uniaxial compression, respectively. The time elapsed between the pre- and the postcompression frames is referred to as the interframe interval. For in vivo elastography, the interframe interval is critical because uncontrolled physiologic motion such as heartbeat, muscle motion, respiration and blood flow introduce interframe decorrelation that reduces the quality of elastograms. To obtain a measure of this decorrelation, in vivo experimental data (from human livers and thyroids) at various interframe intervals were obtained from 20 healthy subjects. To further examine the effect of the different interframe intervals on the elastographic image quality, the experimental data were also used in combination with elastographic simulation data. The deterioration of elastographic image quality was objectively evaluated by computing the area under the strain filter (SF) at a given resolution. The experimental results of this study demonstrate a statistical exponential behavior of the temporal decay of the echo signal cross-correlation amplitudes from the in vivo tissues due to uncontrollable motion. The results also indicate that the dynamic range and height of the SF are reduced at increased interframe intervals, suggesting that good objective image quality may be achieved provided only that a high frame rate is maintained in elastographic applications.

Acoustics↗

Micro-scale measurement of the mechanical properties of compressed pharmaceutical powders. 1: The elasticity and fracture behavior of microcrystalline cellulose.

The feasibility of using very small compacts ( approximately 8.0 x 4.5 x 0.4 mm; approximately 20 mg) to determine the elasticity and fracture behavior of compressed pharmaceutical powders using the three-point beam-bending technique was evaluated. Compacts of microcrystalline cellulose with a range of porosities were tested using a thermomechanical analyzer and values for the Young's modulus and critical stress intensity factor at zero porosity (E(0) and K(IC0)) were determined by extrapolation. The value of E(0) measured at ambient relative humidity on un-notched beams was found to be in close agreement with that reported for much larger samples, and the value of K(IC0) for the small notched compacts was at the lower limit of the accepted range of values for microcrystalline cellulose. The fracture toughness (R) and total energy of fracture (U) for the notched specimens were also determined and used to estimate the apparent surface energies for crack initiation (gamma(i)) and for total fracture (gamma(f)). To further probe the utility of the micro-scale mechanical testing techniques, the effects of humidity on the various mechanical properties of the small microcrystalline compacts were examined and it was found that E(0), K(IC0), R(0), gamma(i0) and gamma(f0) each decreased as the surrounding humidity (and water content of the samples) increased.

Algorithms↗

The use of the SPSA method in ECG analysis.

The classification, monitoring, and compression of electrocardiogram (ECG) signals recorded of a single patient over a relatively long period of time is considered. The particular application we have in mind is high-resolution ECG analysis, such as late potential analysis, morphology changes in QRS during arrythmias, T-wave alternants, or the study of drug effects on ventricular activation. We propose to apply a modification of a classical method of cluster analysis or vector quantization. The novelty of our approach is that we use a new distortion measure to quantify the distance of two ECG cycles, and the class-distortion measure is defined using a min-max criterion. The new class-distortion-measure is much more sensitive to outliers than the usual distortion measures using average-distance. The price of this practical advantage is that computational complexity is significantly increased. The resulting nonsmooth optimization problem is solved by an adapted version of the simultaneous perturbation stochastic approximation (SPSA) method of. The main idea is to generate a smooth approximation by a randomization procedure. The viability of the method is demonstrated on both simulated and real data. An experimental comparison with the widely used correlation method is given on real data.

Algorithms↗

Discovering patterns in Plasmodium falciparum genomic DNA.

A method has been developed for discovering patterns in DNA sequences. Loosely based on the well-known Lempel Ziv model for text compression, the model detects repeated sequences in DNA. The repeats can be forward or inverted, and they need not be exact. The method is particularly useful for detecting distantly related sequences, and for finding patterns in sequences of biased nucleotide composition, where spurious patterns are often observed because the bias leads to coincidental nucleotide matches. We show here the utility of the method by applying it to genomic sequences of Plasmodium falciparum. A single scan of chromosomes 2 and 3 of P. falciparum, using our method and no other a priori information about the sequences, reveals regions of low complexity in both telomeric and central regions, long repeats in the subtelomeric regions, and shorter repeat areas in dense coding regions. Application of the method to a recently sequenced contig of chromosome 10 that has a particularly biased base composition detects a long internal repeat more readily than does the conventional dot matrix plot. Space requirements are linear, so the method can be used on large sequences. The observed repeat patterns may be related to large-scale chromosomal organization and control of gene expression. The method has general application in detecting patterns of potential interest in newly sequenced genomic material.

Algorithms↗

Enhanced sensitivity to residual dipolar couplings of elastomers by higher-order multiple-quantum NMR.

The homonuclear and heteronuclear residual dipolar couplings in elastomers reflect changes in the cross-link density, temperature, the uniaxial and biaxial extension or compression as well as the presence of penetrant molecules. It is shown theoretically that for an isolated methyl group the relative changes in the intensity of the homonuclear double-quantum buildup curves in the initial time regime due to variation of the residual dipolar coupling strength is less sensitive than the changes in the triple-quantum filtered NMR signal when considering the same excitation/reconversion time. For a quadrupolar nucleus with spin I=2 the sensitivity enhancement was simulated for four-quantum, triple-quantum, and double-quantum buildup curves. In this case the four-quantum build-up curve shows the highest sensitivity to changes of spin couplings. This enhanced sensitivity to the residual dipolar couplings was tested experimentally by measuring 1H double-quantum, triple-quantum, and four-quantum buildup curves of differently cross-linked natural rubber samples. In the initial excitation/reconversion time regime, where the residual dipolar couplings can be measured model free, the relative changes in the intensity of the four-quantum buildup curves are about five times higher than those of the double-quantum coherences. For the first time proton four-quantum coherences were recorded for cross-linked elastomers.

Algorithms↗

Electrocardiographic ambulatory monitoring with a real-time analysis system.

The analysis of records collected during long-term ambulatory electrocardiographic monitoring has traditionally involved the review of massive data, either manually or with the aid of interactive scanning computers. Many factors complicate this analysis, including the use of analog tape for storage of electrocardiographic waveforms, the need to analyze 100,000 waveforms from an average 24-hour study, and the need to deal with an interface that compresses 24 hours of data into as little as 6 minutes on a screen. Today, the computer incorporated in the monitor can scrutinize each cardiac cycle in real time. The system produces a statistical report based on every heart beat and also performs data reduction and storage of electrocardiograph samples. To assess real-time analysis we examined data collected from the Circadian CircaMed ambulatory electrocardiography system. We found that it could detect and quantify simple or complex ventricular ectopic beats, brady- or tachyarrhythmic events, and ST-segment deviation. One hundred fifty patients 21 to 85 years old with symptoms or clinical finding suggestive of ischemia, cardiac arrhythmia, or conductive defects were referred to our electrocardiography laboratory for ambulatory monitoring. The results demonstrate that this system can detect the full range of cardiac disease found with the traditional method. Of the 150 patients, ambulatory electrocardiographic tests were positive in 93 (62%). In addition, we developed a methodology for lead placement when using two bipolar leads, as is typical for ambulatory electrocardiography. We present a procedure for determining the optimum lead placement that is based on the patient's history and a 12-lead electrocardiogram.

Adult↗

Resolution of axial shear strain elastography.

The technique of mapping the local axial component of the shear strain due to quasi-static axial compression is defined as axial shear strain elastography. In this paper, the spatial resolution of axial shear strain elastography is investigated through simulations, using an elastically stiff cylindrical lesion embedded in a homogeneously softer background. Resolution was defined as the smallest size of the inclusion for which the strain value at the inclusion/background interface was greater than the average of the axial shear strain values at the interface and inside the inclusion. The resolution was measured from the axial shear strain profile oriented at 45 degrees to the axis of beam propagation, due to the absence of axial shear strain along the normal directions. The effects of the ultrasound system parameters such as bandwidth, beamwidth and transducer element pitch along with signal processing parameters such as correlation window length (W) and axial shift (DeltaW) on the estimated resolution were investigated. The results show that the resolution (at 45 degrees orientation) is determined by the bandwidth and the beamwidth. However, the upper bound on the resolution is limited by the larger of the beamwidth and the window length, which is scaled inversely to the bandwidth. The results also show that the resolution is proportional to the pitch and not significantly affected by the axial window shift.

Algorithms↗

Treatment of spinal involvement in neuroblastoma patients.

INTRODUCTION: Considerable controversy exists regarding the appropriate management of spinal involvement in neuroblastoma (NB) patients. We review a large group of such patients and offer treatment recommendations. METHODS: Forty-six patients with epidural and/or neural foraminal involvement treated between 1987 and 1998 were staged according to the International NB Staging System (INSS) and classified as high-risk (INSS stage 4; n = 31) or low-risk (INSS stage <4; n = 15). Of 13 high- risk patients with normal neurologic examinations and no radiographic high-grade spinal cord compression (HGSCC), 12 were treated initially with chemotherapy, and only 1 demonstrated neurologic deterioration. HGSCC was present in 18 patients with high-risk NB; 7 of 10 (70%) treated initially with chemotherapy and 6 of 6 (100%) managed initially with operation improved or remained stable. All 9 low-risk patients with normal neurologic examinations and no HGSCC remained neurologically intact following operations (n = 7) or chemotherapy (n = 2). All 4 low-risk patients with HGSCC treated with operations improved or remained stable, and 0 of 2 (0%) low-risk patients treated initially with chemotherapy remained stable. Spinal deformities occurred in 2 of 16 patients (12.5%) treated nonoperatively and in 9 of 30 (30.0%) who underwent operations. CONCLUSIONS: High-risk NB patients with spinal involvement but normal neurologic examinations should be offered chemotherapy. High-risk patients with HGSCC may respond to chemotherapy, but a small percentage will require operations for progressive neurologic deficits. Chemotherapy may be avoided in low-risk patients who are offered potentially curative operations. Patients treated with operations for epidural disease are at high risk of subsequently developing spinal deformity.

Adolescent↗

[Modern algorithm for treating pudendal neuralgia: 212 cases and 104 decompressions].

Clinical signs and symptoms of the pudendal neuralgia are very rich, with a great individual variability. The clinical diagnosis is difficult. It is confirmed or invalidated by the electrophysiologicals tests. Since October 1998 patient selection has been possible using a diagnosis score. Over a four-year period, the diagnosis of pudendal neuralgia was confirmed by electrophysiological investigations in 212 subjects. We rejected 12 patients because of a radiculo-medullary organic etiology. We only describe here cases of women with a peripheral pudendal nerve injury (200 patients). Thirty-eight neuropathies free of canal symptoms (obstetrical, post-traumatic...) were treated by infiltration therapy. The study of a total of 162 canal syndromes showed prevalent injury at the sacro-spino-tuberal ligamental grip which was observed in 68% of the cases, compared to the Alcock canal which was present in only 20% of the cases. One hundred four of these patients underwent surgical decompression via a trans-ischio-rectal approach after negative results of the infiltration therapy. We report here the surgical methodology, the post-op follow-up and the results, which appear quite successful: after one year 86% of the subjects are symptom-free or with a significant reduction of pain.

Adult↗

Excipient-excipient interaction in the design of sustained-release theophylline tablets: in vitro and in vivo evaluation.

Sustained-release (SR) theophylline (TPH) tablets were prepared by applying the moisture-activated dry granulation method. The interaction between the excipients sodium alginate (SAL) and calcium gluconate (CG) was the base for the formation of a cross-linked matrix that may regulate TPH release from the formulated tablets. The prepared granules showed good physical characteristics concerning the flow properties and compressibility, with the angles of repose in the range 29-31, and the compressibility indices ranged between 15% and 25%. The granules had low friability values (3.0%-4.2%), depending on SAL:CG ratios. The corresponding tablets showed good physical properties, with a lower rate of drug release compared with the commercial TPH tablets (Quibron). The release of TPH from the prepared tablets was not markedly affected by either the concentration of added dry binder (carbopol 934) or the tablet hardness, indicating that the rate-determining step in drug release was the diffusion through the produced calcium alginate matrix. Tablets formulated with equal ratios of CG and SAL that showed good physical properties and slow TPH release were chosen for bioavailability studies in beagle dogs, and results were compared with those for Quibron. The in vivo data showed a comparable plasma concentration profile for both tablet formulations, with prolonged appearance of drug in the plasma in detectable amounts for up to 24 h. The formulated tablets showed 104.65% bioavailability relative to that of the commercial tablets. The rate and extent of absorption of TPH showed no significant differences from that of the commercial tablets. Moreover, no significant differences were found in the pharmacokinetic parameters related to the rate and extent of TPH absorption from the prepared and commercial tablets.

Alginates↗

Design, characterisation and preliminary clinical evaluation of a novel mucoadhesive topical formulation containing tetracycline for the treatment of periodontal disease.

This study describes the formulation, characterisation and preliminary clinical evaluation of mucoadhesive, semi-solid formulations containing hydroxyethylcellulose (HEC, 1-5%, w/w), polyvinylpyrrolidine (PVP, 2 or 3%, w/w), polycarbophil (PC, 1 or 3%, w/w) and tetracycline (5%, w/w, as the hydrochloride). Each formulation was characterised in terms of drug release, hardness, compressibility, adhesiveness (using a texture analyser in texture profile analysis mode), syringeability (using a texture analyser in compression mode) and adhesion to a mucin disc (measured as a detachment force using the texture analyser in tensile mode). The release exponent for the formulations ranged from 0.78+/-0.02 to 1. 27+/-0.07, indicating that drug release was non-diffusion controlled. Increasing the concentrations of each polymeric component significantly increased the time required for 10 and 30% release of the original mass of tetracycline, due to both increased viscosity and, additionally, the unique swelling properties of the formulations. Increasing concentrations of each polymeric component also increased the hardness, compressibility, adhesiveness, syringeability and mucoadhesion of the formulations. The effects on product hardness, compressibility and syringeability may be due to increased product viscosity and, hence, increased resistance to compression. Similarly, the effects of these polymers on adhesiveness/mucoadhesion highlight their mucoadhesive nature and, importantly, the effects of polymer state (particularly PC) on these properties. Thus, in formulations where the neutralisation of PC was maximally suppressed, adhesiveness and mucoadhesion were also maximal. Interestingly, statistical interactions were primarily observed between the effects of HEC and PC on drug release, mechanical and mucoadhesive properties. These were explained by the effects of HEC on the physical state of PC, namely swollen or unswollen. In the preliminary clinical evaluation, a formulation was selected that offered an appropriate balance of the above physical properties and contained 3% HEC, 3% PVP and 1% PC, in addition to tetracycline 5% (as the hydrochloride). The clinical efficacy of this (test) formulation was compared to an identical tetracycline-devoid (control) formulation in nine periodontal pockets (>/=5 mm depth). One week following administration of the test formulation, there was a significant improvement in periodontal health as identified by reduced numbers of sub-gingival microbial pathogens. Therefore, it can be concluded that, when used in combination with mechanical plaque removal, the tetracycline-containing semi-solid systems described in this study would augment such therapy by enhancing the removal of pathogens, thus improving periodontal health.

Acrylic Resins↗

Linear, worst-case estimators for denoising quantization noise in transform coded images.

Transform-coded images exhibit distortions that fall outside of the assumptions of traditional denoising techniques. In this paper, we use tools from robust signal processing to construct linear, worst-case estimators for the denoising of transform compressed images. We show that while standard denoising is fundamentally determined by statistical models for images alone, the distortions induced by transform coding are heavily dependent on the structure of the transform used. Our method, thus, uses simple models for the image and for the quantization error, with the latter capturing the transform dependency. Based on these models, we derive optimal, linear estimators of the original image that are optimal in the mean-squared error sense for the worst-case cross correlation between the original and the quantization error. Our construction is transform agnostic and is applicable to transforms from block discrete cosine transforms to wavelets. Furthermore, our approach is applicable to different types of image statistics and can also serve as an optimization tool for the design of transforms/quantizers. Through the interaction of the source and quantizer models, our work provides useful insights and is instrumental in identifying and removing quantization artifacts from general signals coded with general transforms. As we decouple the modeling and processing steps, we allow for the construction of many different types of estimators depending on the desired sophistication and available computational complexity. In the low end of this spectrum, our lookup table based estimator, which can be deployed in low complexity environments, provides competitive PSNR values with some of the best results in the literature.

Algorithms↗

A search for optimal x-ray spectra in iodine contrast media mammography.

The aim of this work was to search for the optimal x-ray tube voltage and anode-filter combination in digital iodine contrast media mammography. In the optimization, two entities were of interest: the average glandular dose, AGD, and the signal-to-noise ratio, SNR, for detection of diluted iodine contrast medium. The optimum is defined as the technique maximizing the figure of merit, SNR2/AGD. A Monte Carlo computer program was used which simulates the transport of photons from the x-ray tube through the compression plate, breast, breast support plate, anti-scatter grid and image detector. It computes the AGD and the SNR of an iodine detail inside the compressed breast. The breast thickness was varied between 2 and 8 cm with 10-90% glandularity. The tube voltage was varied between 20 and 55 kV for each anode material (Rh, Mo and W) in combination with either 25 microm Rh or 0.05-0.5 mm Cu added filtration. The x-ray spectra were calculated with MCNP4C (Monte Carlo N-Particle Transport Code System, version 4C). A CsI scintillator was used as the image detector. The results for Rh/0.3 mmCu, Mo/0.3 mmCu and W/0.3 mmCu were similar. For all breast thicknesses, a maximum in the figure of merit was found at approximately 45 kV for the Rh/Cu, Mo/Cu and W/Cu combinations. The corresponding results for the Rh/Rh combination gave a figure of merit that was typically lower and more slowly varying with tube voltage. For a 4 cm breast at 45 kV, the SNR2/AGD was 3.5 times higher for the Rh/0.3 mmCu combination compared with the Rh/Rh combination. The difference is even larger for thicker breasts. The SNR2/AGD increases slowly with increasing Cu-filter thickness. We conclude that tube voltages between 41 and 55 kV and added Cu-filtration will result in significant dose advantage in digital iodine contrast media mammography compared to using the Rh/Rh anode/filter combination at 25-32 kV.

Algorithms↗

Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast.

The objective of this work was to develop a robotic device to perform biopsy and therapeutic interventions in the breast with real-time magnetic resonance imaging (MRI) guidance. The device was designed to allow for (i) stabilization of the breast by compression, (ii) definition of the interventional probe trajectory by setting the height and pitch of a probe insertion apparatus, and (iii) positioning of an interventional probe by setting the depth of insertion. The apparatus is fitted with five computer-controlled degrees of freedom for delivering an interventional procedure. The entire device is constructed of MR compatible materials, i.e. nonmagnetic and non-conductive, to eliminate artifacts and distortion of the MR images. The apparatus is remotely controlled by means of ultrasonic motors and a graphical user interface, providing real-time MR-guided planning and monitoring of the operation. Joint motion measurements found probe placement in less than 50 s and sub-millimeter repeatability of the probe tip for same-direction point-to-point movements. However, backlash in the rotation joint may incur probe tip positional errors of up to 5 mm at a distance of 40 mm from the rotation axis, which may occur for women with large breasts. The imprecision caused by this backlash becomes negligible as the probe tip nears the rotation axis. Real-time MR-guidance will allow the physician to correct this error Compatibility of the device within the MR environment was successfully tested on a 4 Tesla MR human scanner

Algorithms↗

Noninvasive determination of bone mechanical properties using vibration response: a refined model and validation in vivo.

Accurate non-invasive mechanical measurement of long bones is made difficult by the masking effect of surrounding soft tissues. Mechanical response tissue analysis (MRTA) offers a method for separating the effects of the soft tissue and bone; however, a direct validation has been lacking. A theoretical analysis of wave propagation through the compressed tissue revealed a strong mass effect dependent on the relative accelerations of the probe and bone. The previous mathematical model of the bone and overlying tissue system was reconfigured to incorporate the theoretical finding. This newer model (six-parameter) was used to interpret results using MRTA to determine bone cross-sectional bending stiffness, EIMRTA. The relationship between EIMRTA and theoretical EI values for padded aluminum rods was R2 = 0.999. A biological validation followed using monkey tibias. Each bone was tested in vivo with the MRTA instrument. Postmortem, the same tibias were excised and tested to failure in three-point bending to determine EI3-PT and maximum load. Diaphyseal bone mineral density (BMD) measurements were also made. The relationship between EI3-PT and in vivo EIMRTA using the six-parameter model is strong (R2 = 0.947) and better than that using the older model (R2 = 0.645). EIMRTA and BMD are also highly correlated (R2 = 0.853). MRTA measurements in vivo and BMD ex vivo are both good predictors of scaled maximum strength (R2 = 0.915 and R2 = 0.894, respectively). This is the first biological validation of a non-invasive mechanical measurement of bone by comparison to actual values. The MRTA technique has potential clinical value for assessing long-bone mechanical properties.

Acceleration↗

Evaluation of surface and build-up region dose for intensity-modulated radiation therapy in head and neck cancer.

Despite much development, there remains dosimetric uncertainty in the surface and build-up regions in intensity-modulated radiation therapy treatment plans for head and neck cancers. Experiments were performed to determine the dosimetric discrepancies in the surface and build-up region between the treatment planning system (TPS) prediction and experimental measurement using radiochromic film. A head and neck compression film phantom was constructed from two semicylindrical solid water slabs. Treatment plans were generated using two commercial TPSs (PINNACLE3 and CORVUS) for two cases, one with a shallow (approximately 0.5 cm depth) target and another with a deep (approximately 6 cm depth) target. The plans were evaluated for a 54 Gy prescribed dose. For each case, two pieces of radiochromic film were used for dose measurement. A small piece of film strip was placed on the surface and another was inserted within the phantom. Overall, both TPSs showed good agreement with the measurement. For the shallow target case, the dose differences were within +/- 300 cGy (5.6% with respect to the prescribed dose) for PINNACLE3 and +/- 240 cGy (4.4%) for CORVUS in 90% of the region of interest. For the deep target case, the dose differences were +/- 350 (6.5%) for PINNACLE3 and +/- 260 cGy (4.8%) for CORVUS in 90% of the region of interest. However, it was found that there were significant discrepancies from the surface to about 0.2 cm in depth for both the shallow and deep target cases. It was concluded that both TPSs overestimated the surface dose for both shallow and deep target cases. The amount of overestimation ranges from 400 to 1000 cGy (approximately 7.4% to 18.5% with respect to the prescribed dose, 5400 cGy).

Algorithms↗