Effects of chromatography conditions on intact protein separations for top-down proteomics.

For top-down proteomics, nano-reversed phase liquid chromatography (RPLC) plays a major role in both single and multidimensional protein separations in an effort to increase the overall peak capacity for the resolution of complex protein mixtures prior to mass spectrometry analysis. Effects of various chromatography conditions, including alkyl chain length in the stationary phase, capillary column temperature, and ion-pairing agent, on the resolution of intact proteins are studied using nano-RPLC-electrospray ionization-mass spectrometry. Optimal chromatography conditions include the use of C18 column heated at 60 degrees C and the addition of trifluoroacetic acid instead of heptafluorobutyric acid as the ion-paring agent in the mobile phase. Under optimized chromatography conditions, there are no significant differences in the separation performance of yeast cell lysates present in the native versus denatured states. Denatured yeast proteins resolved and eluted from nano-RPLC can be subjected to proteolytic digestion in an on- or off-line approach to provide improved protein sequence coverage toward protein identification in a combined top-down/bottom-up proteome platform.

Chromatography, High Pressure Liquid↗

Chromatography of plasmid DNA.

Liquid chromatography plays a central role in process-scale manufacturing of therapeutic plasmid DNA (pDNA) for gene therapy and DNA vaccination. Apart from its use as a preparative purification step, it is also very useful as an analytical tool to monitor and control pDNA quality during processing and in final formulations. This paper gives an overview of the use of pDNA chromatography. The specificity of pDNA purification and the consequent limitations to the performance of chromatography are described. Strategies currently used to overcome those limitations, as well as other possible solutions are presented. Applications of the different types of chromatography to the purification of therapeutic pDNA are reviewed, and the main advantages and disadvantages behind each technique highlighted.

Chromatography, Liquid↗

Role of ion pairing in anionic additive effects on the separation of cationic drugs in reversed-phase liquid chromatography.

Mobile phase additives can significantly affect the separation of cationic drugs in reversed-phase liquid chromatography (RPLC). Although there are many applications for anionic additives in RPLC separations, the retention mechanism of basic drugs in the presence of inorganic and highly hydrophilic anionic species in the mobile phase is not at all well understood. Two major retention mechanisms by which anionic additives can influence the retention of cations are: (1) ion pair formation in the mobile phase with subsequent retention of the neutral ion pair; (2) pre-sorption of anionic additives on the stationary phase followed by "dynamic ion-exchange" or "electrostatic interaction" with the analytes. Because the use of ion pair chromatography in the separation of proteins, peptides, and basic drugs is rapidly increasing, understanding the retention mechanism involved is becoming more important, especially for the smaller commonly used hydrophilic anionic additives (e.g., formate HCOO, chloride Cl-, trifluoroacetate CF3COO-, perchlorate ClO4-, and hexafluorophosphate PF6-). In this work, we compared various anionic additives in light of their effects on the retention of basic drugs. As did many others we found that the addition of anionic additives (Cl-, CF3COO-, ClO4-, PF6-) profoundly influences the retention of basic drugs. In order to explain the data and differentiate the mechanisms by which the anionic additives perturb the chromatography, we used ion pair formation constants independently measured by capillary electrophoresis (CE) under the mobile phase conditions (pH, solvent composition) identical to those used in chromatography. Agreement between the predicted and experimental chromatographic data under various conditions was evaluated. Under specific circumstances (e.g., pH, stationary phase, and nature of anionic additive), we conclude that the ion pair mechanism is more important than the dynamic ion-exchange and at other conditions it remains a significant contribution.

Anions↗

Ultra-short open capillary columns in gas-liquid chromatography.

New area in capillary gas chromatography (GC) was investigated. Many important analytical tasks can be solved only use very short capillary columns. Variation of chromatographic characteristics of ultra-short capillary columns with column length was originally studied at the conditions of gas-liquid chromatography. The column length varied from 500 to 10 cm. Dependencies of height equivalent to one theoretical plate (HETP) and separation number (SN) on carrier gas velocity were considered for columns of various length. Field of ultra-short open capillary columns in gas-liquid chromatography has the following peculiarities: (1) more shorter retention times of sorbates, (2) more low temperatures of short column, that has as final result (a) high selectivities of used column and (b) the possibilities to separation more thermal lability compounds. It was shown that short capillary columns can be successfully used at both isothermal and temperature programming conditions for express-analysis at lower oven temperatures. Examples of express-analysis (high speed), analysis of high boiling and thermolabile compounds are listed, which demonstrate some radically new applications of capillary gas chromatography.

Chromatography, Gas↗

Effects of sequence and structure in the separation of nucleic acids using ion pair reverse phase liquid chromatography.

Ion pair reverse phase high performance liquid chromatography on non-porous alkylated poly(styrene-divinylbenzene) particles enables the high resolution separation of double stranded DNA fragments. To further understand the separation mechanisms involved in ion pair reverse phase liquid chromatography we have analysed the effects of curved or "bent" DNA fragments with respect to their separation using both gel electrophoresis and ion pair reverse phase liquid chromatography. Size dependent separations of curved DNA fragments that migrate anomalously during gel electrophoresis were observed using ion pair reverse phase liquid chromatography. To further study the sequence effect and resulting changes in hydrophobicity of the duplex DNA, PCR fragments were generated that contain uracil in place of thymine. The resulting fragments were shown to elute with shorter retention times, demonstrating that sequence-specific effects can alter the retention of duplex DNA. The study was extended to the investigation of non-canonical B-DNA structures (Holliday junctions) under various chromatographic conditions, demonstrating that the coaxial stacking of the helices in such structures, in the presence of magnesium causes a change in retention.

Base Sequence↗

Optimisation and robustness analysis of a hydrophobic interaction chromatography step.

Process development, optimisation and robustness analysis for chromatography separations are often entirely based on experimental work and generic knowledge. The present study proposes a method of gaining process knowledge and assisting in the robustness analysis and optimisation of a hydrophobic interaction chromatography step using a model-based approach. Factorial experimental design is common practice in industry today for robustness analysis. The method presented in this study can be used to find the critical parameter variations and serve as a basis for reducing the experimental work. In addition, the calibrated model obtained with this approach is used to find the optimal operating conditions for the chromatography column. The methodology consists of three consecutive steps. Firstly, screening experiments are performed using a factorial design. Secondly, a kinetic-dispersive model is calibrated using gradient elution and column load experiments. Finally, the model is used to find optimal operating conditions and a robustness analysis is conducted at the optimal point. The process studied in this work is the separation of polyclonal IgG from BSA using hydrophobic interaction chromatography.

Adsorption↗

Temperature-responsive stationary phase utilizing a polymer of proline derivative for hydrophobic interaction chromatography using an aqueous mobile phase.

A new method of chromatography is proposed, utilizing a thermo-responsive polymer carrying an amino acid ester residue for the stationary phase of high-performance liquid chromatography (HPLC). We have been investigating the new concept of chromatography, a temperature-responsive chromatography, using temperature-responsive poly(N-isopropylacrylamide) (PNIPAAm)-modified surface for HPLC with a constant aqueous media as the mobile phase. In this study, we designed and synthesized thermo-responsive poly(acryloyl-L-proline methyl ester) and its copolymer with N-isopropylacrylamide (NIPAAm). Homopolymers of acryloyl-L-proline methyl ester and copolymer were prepared by the reaction of radical telomerization. These polymers underwent a reversible phase transition from water-soluble forms into aggregates by changing the temperature, similar to PNIPAAm. The surface properties and functions of stationary phases modified with poly(acryloyl-L-proline methyl ester) were controlled by the external temperature. In the chromatographic system, we separated steroids and amino acids with a variety of hydrophobicities using a sole aqueous mobile phase. In contrast to a PNIPAAm-modified surface, a poly(acryloyl-L-proline methyl ester)-modified surface showed a greater affinity for hydrophobic amino acids.

Chromatography, Liquid↗

Affinity chromatography matures as bioinformatic and combinatorial tools develop.

Affinity chromatography has the reputation of a more expensive and less robust than other types of liquid chromatography. Furthermore, the technique is considered to stand a modest chance of large-scale purification of proteinaceous pharmaceuticals. This perception is changing because of the pressure for quality protein therapeutics, and the realization that higher returns can be expected when ensuring fewer purification steps and increased product recovery. These developments necessitated a rethinking of the protein purification processes and restored the interest for affinity chromatography. This liquid chromatography technique is designed to offer high specificity, being able to safely guide protein manufactures to successfully cope with the aforementioned challenges. Affinity ligands are distinguished into synthetic and biological. These can be generated by rational design or selected from ligand libraries. Synthetic ligands are generated by three methods. The rational method features the functional approach and the structural template approach. The combinatorial method relies on the selection of ligands from a library of synthetic ligands synthesized randomly. The combined method employs both methods, that is, the ligand is selected from an intentionally biased library based on a rationally designed ligand. Biological ligands are selected by employing high-throughput biological techniques, e.g. phage- and ribosome-display for peptide and microprotein ligands, in addition to SELEX for oligonucleotide ligands. Synthetic mimodyes and chimaeric dye-ligands are usually designed by rational approaches and comprise a chloro-triazinlyl scaffold. The latter substituted with various amino acids, carbocyclic, and heterocyclic groups, generates libraries from which synthetic ligands can be selected. A 'lead' compound may help to generating a 'focused' or 'biased' library. This can be designed by various approaches, e.g.: (i) using a natural ligand-protein complex as a template; (ii) applying the principle of complementarity to exposed residues of the protein structure; and (iii) mimicking directly a natural biological recognition interaction. Affinity ligands, based on the peptide structure, can be peptides, peptide-mimetic derivatives (<30 monomers) and microproteins (e.g. 25-200 monomers). Microprotein ligands are selected from biological libraries constructed of variegated protein domains, e.g. minibody, Kunitz, tendamist, cellulose-binding domain, scFv, Cytb562, zinc-finger, SpA-analogue (Z-domain).

Aldehyde Oxidoreductases↗

Separation of branched polystyrene by comprehensive two-dimensional liquid chromatography.

Branched polystyrenes (PS) featuring a bivariate distribution in the molecular weight and in the number of branches were characterized by comprehensive two-dimensional liquid chromatography (2D-LC). The branched PS were prepared by anionic polymerization using n-butyl Li as an initiator and a subsequent linking reaction with p-(chlorodimethylsilyl)styrene (CDMSS). The n-butyl Li initiator yields polystyryl anions with broad molecular weight distribution (MWD) and the linking reaction with CDMSS yields branched PS with different number of branches. For the first dimension (1st-D) separation, reversed-phase temperature gradient interaction chromatography (RP-TGIC) was employed to separate the branched polymer according to mainly the molecular weight. In the second dimension (2nd-D) separation, the effluents from the RP-TGIC separation are subjected to liquid chromatography at chromatographic critical conditions (LCCC), in which the separation was carried out at the critical condition of linear homo-PS to separate the branched PS in terms of the number of branches. The 2D-LC resolution of RP-TGICxLCCC combination worked better than the common LCCCxsize-exclusion chromatography (SEC) configuration due to the higher resolution of RP-TGIC in molecular weight than SEC. Furthermore, by virtue of using the same eluent in RP-TGIC and LCCC (only the column temperature is different), RP-TGICxLCCC separation is free from possible 'break through' and large system peak problems. This type of 2D-LC separation could be utilized efficiently for the analysis of branched polymers with branching units distinguishable by LC separation.

Chromatography, Liquid↗

Off-line comprehensive two-dimensional high-performance liquid chromatography system with size exclusion column and reverse phase column for separation of complex traditional Chinese medicine Qingkailing injection.

A comprehensive two-dimensional liquid chromatography system was constructed on the combination of size exclusion chromatography (SEC) and reverse phase liquid chromatography (RPLC). The first dimension used a SEC column with 300 mm x 8mm i.d., packed with Toyopearl HW-40S. The column was eluted with 0.05 mol/l Tris-HCl (pH 6.9) at a flow rate of 0.4 ml/min. The second dimension used a RPLC column with 100 mm x 4.6mm i.d., which was operated in gradient form at a flow rate of 1.0 ml/min. An automatic switching valve was used to collect the effluent of the SEC column every 3 min, and the effluent was automatically injected into the RPLC column. Mass spectrometer was used for peak identification. This system was used to separate Qingkailing injection, a traditional Chinese medicine (TCM). The result showed that the total peak capacity of this system could reach 1134 and the qualitative analysis of seven chemical components of the Qingkailing injection was accomplished by this system. The results show that comprehensive two-dimensional liquid chromatography system is of great importance and high value in the separation of complex TCM.

Chromatography, High Pressure Liquid↗

Chromatography as Lévy stochastic process.

The Stochastic Theory of Chromatography has been revised in light of some of the most relevant Lévy's findings in Theory of Probability, including the so-called Lévy's distance, the characteristic function and the theory of infinitesimally divisible distributions. These concepts represent the key to exploit and understand, at a molecular basis, phenomena typical of chromatographic separations under linear conditions, such as peak tailing and splitting. In particular, Lévy's distance has been used to quantify the degree of convergence of real peaks towards an ideal Gaussian shape; the characteristic function properties, introduced by Lévy to deal with the problem of the addition of independent random variables, have been employed to solve a wide variety of chromatographic models (including adsorption on heterogeneous surfaces) and to interpret mobile phase dispersion from a probabilistic point of view. Finally, Lévy's studies concerning infinitesimally divisible distributions have allowed to introduce in the stochastic description of chromatography, effects associated to dispersion in mobile phase. It has been demonstrated that, according to Lévy's canonical representation of stochastic processes, the basis of chromatography is a mobile phase Poisson Process. Represented as a Lévy's process, the microscopic-probabilistic model of chromatography permits the establishment of a connection between single-molecule properties and their statistical fluctuations and shapes of real chromatographic peaks allowing, at the same time, for the constitution of a link between different branches of physical sciences.

Chromatography↗

Visualising viscous fingering in chromatography columns: high viscosity solute plug.

The interface between two fluids that have different viscosities and are percolating through a porous bed is unstable. Sooner or later, a flow instability termed viscous fingering (VF) develops. This phenomenon is important in chromatography because the solute plug does not have the same viscosity as the mobile phase. Because the sample is often much more viscous than the mobile phase, it is the interface at the rear of the sample band that is usually unstable. This situation is frequent in many modes of chromatography, e.g., in preparative and in multidimensional chromatography, in size exclusion chromatography, in frontal analysis, and in other physicochemical measurements (e.g., determination of adsorption isotherms and of mass transfer parameters). When the solute plug is more viscous than the mobile phase, we observed that the solute band compressed. When the viscosity contrast increased up to 0.30 cP, fingers appeared to trail behind the solute plug. The development of fingers then became more substantial as the viscosity contrast increased. To avoid effects associated with VF, the mobile phase and the solute plug should have nearly the same viscosity.

Adsorption↗

Alternative bioseparation operations: life beyond packed-bed chromatography.

Chromatography is undoubtedly the workhorse of downstream processes, affording high resolution for bioseparations. At the same time, it has the notoriety of being the single largest cost center in downstream processing and of being a low-throughput operation. Consequently, 'chromatography alternatives' are an attractive proposition, even if only a reduction in the extent of use of packed beds can be realized. This paper reviews the current state of unit operations posing as chromatography alternatives--including membrane filtration, aqueous two-phase extraction, three-phase partitioning, precipitation, crystallization, monoliths and membrane chromatography--and their potential to do the unthinkable.

Chemistry, Physical↗

Improved purification of beta-lactoglobulin from acid whey by means of ceramic hydroxyapatite chromatography with sodium fluoride as a displacer.

The successful separation of beta-lactoglobulin from other bovine whey proteins was performed by ceramic hydroxyapatite chromatography with a fluoride ion gradient in phosphate buffer as displacement agent. The method was applied to acid whey originating from milk of healthy as well as of mastitic cows. beta-Lactoglobulin was completely eluted in one peak at a fluoride concentration of about 0.6 mol/l. The purity of beta-lactoglobulin in this fraction was at least 96% if whey from healthy milk was processed. Co-eluted contaminants are traces of immunoglobulin G, serum albumin and lactoferrin. In case of mastitic whey the proportion of beta-lactoglobulin is diminished as the amounts of immunglobulin G, serum albumin and lactoferrin are increased within this fraction. Size exclusion chromatography on Superdex 75 pg effectively removed contaminants resulting in a purity for beta-lactoglobulin from normal whey of approximately 99%. The yield of beta-lactoglobulin from physiological whey was 50-55% referring to the fraction highly enriched with beta-lactoglobulin by hydroxyapatite chromatography. In case of mastitic milk the higher amounts of contaminants were also removed successfully by size exclusion chromatography.

Chromatography, Liquid↗

Fungal mycelium--the source of chitosan for chromatography.

Mycelium of the mold Aspergillus niger was used as a raw material for the preparation of microbial chitosan. Aspergillus niger, the mold used for the production of citric acid, contains approx. 15% of chitin, which can be separated, transformed into chitosan, and used as a sorbent for chromatography. The main advantage of this material in comparison with krill chitosan is the uniformity of particle size leading to the low back-pressure in the column. The other advantage is the fact, that original fibrous structure of mycelial pellets could be stabilized before chitosan preparation by cross-linking with glutaraldehyde. The product prepared by this way -- crosslinked chitosan of uniform particle size, is highly porous, with high water regain and, as a result, low sedimentation velocity. Low sedimentation velocity is not disadvantage in chromatographic application, but may form some problems in batchwise operation. Chitosan as a polymer of glucosamine is anion exchanger in nature and the chromatographic properties of this anion exchanger was demonstrated by the chromatography of bovine blood plasma, glucose oxidase, and chicken pepsinogen. In all cases, the course of chromatography on crosslinked chitosan was compared with the chromatography on MONO Q (bovine blood plasma) or DEAE-cellulose (glucose oxidase, chicken pepsinogen) under the same protocol.

Chitosan↗

Development of a gas chromatography method for the determination of isotretinoin and its degradation products in pharmaceuticals.

This paper describes the development of a gas chromatography (GC) method used for the assay of isotretinoin in its isolated form and in pharmaceutical formulations. Isotretinoin soft and hard gelatin capsules were prepared with various excipients. The performance of the proposed gas chromatography method was compared to that of traditional high performance liquid chromatography (HPLC) systems for this substance, and the GC parameters were established based on several preliminary tests, including thermal analysis of isotretinoin. Results showed that gas chromatography-flame ionization detector (GC-FID) exhibited a separation efficiency superior to that of HPLC, particularly for separating isotretinoin degradation products. This method was proven to be effectively applicable to stability evaluation assays of isotretinoin and isotretinoin based pharmaceuticals.

Chromatography, Gas↗

Anion-exchange chromatography using short monolithic columns as a complementary technique for human serum albumin depletion prior to human plasma proteome analysis.

In order to enable the detection of low abundance proteins from human plasma, it is necessary to remove high abundance proteins. Among them, human serum albumin and immunoglobulin G represent more than 75% of all such proteins. In this paper, the characterization of short monolithic columns was performed followed by the optimization of a multidimensional approach, known as conjoint liquid chromatography, to deplete human serum albumin and immunoglobulin G from a human plasma sample. Two different chromatographic modes were used: ion-exchange chromatography and affinity chromatography. A monolithic stationary phase (convective interaction media disk) bearing strong anion-exchange groups and another immobilized with protein G were placed in series into one housing. The optimal binding conditions were found that removed a majority of human serum albumin and immunoglobulin G from the human plasma sample. This method was compared to the depletion using a combination of pseudo-affinity and affinity columns. The results of the human serum albumin and immunoglobulin G depletion were confirmed by 2D electrophoresis. It has been shown that anion-exchange and affinity chromatography using convective interaction media monolithic columns can represent an efficient complementary technique for human serum albumin and immunoglobulin G removal from human plasma.

Biomarkers↗

High-throughput protein purification using an automated set-up for high-yield affinity chromatography.

One of the key steps in high-throughput protein production is protein purification. A newly developed high-yield protein purification and isolation method for laboratory scale use is presented. This procedure allows fully automated purification of up to 60 cell lysates with milligram yields of pure recombinant protein in 18.5h. The method is based on affinity chromatography and has been set up on an instrument that utilizes positive pressure for liquid transfer through columns. A protocol is presented that includes all steps of equilibration of the chromatography resin, load of sample, wash, and elution without any manual handling steps. In contrast to most existing high-throughput protein purification procedures, positive pressure is used for liquid transfer rather than vacuum. Positive pressure and individual pumps for each liquid channel contribute to controlled flow rates and eliminate the risk of introducing air in the chromatography resin and therefore ensure stable chromatography conditions. The procedure is highly reproducible and allows for high protein yield and purity.

Chromatography, Affinity↗