Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Sound”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87Linked to original sources

Motion aftereffects with horizontally moving sound sources in the free field.

A horizontally moving sound was presented to an observer seated in the center of an anechoic chamber. The sound, either a 500-Hz low-pass noise or a 6300-Hz high-pass noise, repeatedly traversed a semicircular arc in the observer's front hemifield at ear level (distance: 1.5 m). At 10-sec intervals this adaptor was interrupted, and a 750-msec moving probe (a 500-Hz low-pass noise) was presented from a horizontal arc 1.6 m in front of the observer. During a run, the adaptor was presented at a constant velocity (-200 degrees to +200 degrees/sec), while probes with velocities varying from -10 degrees to +10 degrees/sec were presented in a random order. Observers judged the direction of motion (left or right) of each probe. As in the case of stimuli presented over headphones (Grantham & Wightman, 1979), an auditory motion aftereffect (MAE) occurred: subjects responded "left" to probes more often when the adaptor moved right than when it moved left. When the adaptor and probe were spectrally the same, the MAE was greater than when they were from different spectral regions; the magnitude of this difference depended on adaptor speed and was subject-dependent. It is proposed that there are two components underlying the auditory MAE: (1) a generalized bias to respond that probes move in the direction opposite to that of the adaptor, independent of their spectra; and (2) a loss of sensitivity to the velocity of moving sounds after prolonged exposure to moving sounds having the same spectral content.

Acceleration↗

Sound quality measures for speech in noise through a commercial hearing aid implementing digital noise reduction.

This brief report discusses the affect of digital noise reduction (DNR) processing on aided speech recognition and sound quality measures in 14 adults fitted with a commercial hearing aid. Measures of speech recognition and sound quality were obtained in two different speech-in-noise conditions (71 dBA speech, +6 dB SNR and 75 dBA speech, +1 dB SNR). The results revealed that the presence or absence of DNR processing did not impact speech recognition in noise (either positively or negatively). Paired comparisons of sound quality for the same speech in noise signals, however, revealed a strong preference for DNR processing. These data suggest that at least one implementation of DNR processing is capable of providing improved sound quality, for speech in noise, in the absence of improved speech recognition.

Adult↗

Effects of stimulus intensity on sound localization in the horizontal and upper-hemispheric median plane.

Sound lateralization ability with headphones is known to be affected by stimulus intensity. However, there have been few studies on sound localization with loudspeakers in free field from the standpoint of stimulus intensity. The aim of this study is to obtain basic data for the tests with normal hearing and hearing-impaired subjects, and for the fitting of a hearing aid. The author investigated the relationship between stimulus intensities and sound localization ability of the broadband noise and pure tone bursts delivered in the horizontal and upper-hemispheric median planes. Subjects were ten volunteers, 5 males and 5 females, at the age of 18-19 years, with normal hearing. The results showed well how subjects perceived directions at all stimulus intensities. The percentage of correct response (%correct) for broadband noise stimuli was maximum at the intensity from 40 to 70 dB SPL (sound pressure level), and was minimum at 0 to 20 dB SPL in both the horizontal plane and the upper-hemispheric median plane. At lower stimulus intensity, examinee could not judge the direction, even if they could hear the stimuli. For pure tone bursts stimuli in the upper-hemispheric median plane, %correct was low irrespective of stimulus intensity.

Acoustic Stimulation↗

The effect of sound direction on frequency tuning in mouse inferior collicular neurons.

This study examined the effect of sound direction on frequency tuning of inferior collicular (IC) neurons of mice under free field stimulation conditions. Fewer than 20% of IC neurons studied were spontaneously active. Discharge patterns can be described as phasic on responders, phasic on-off responders, off responders, choppers and tonic responders. The frequency tuning curves (FTCs) of IC neurons can be described as narrow, intermediate or broad. Although sound direction typically had little effect on most best frequencies (BFs), sharpness of FTCs increased as sound direction changed from contralateral angles to ipsilateral angles. Sound delivered from the upper and lower portions of the frontal auditory space also appeared to produce sharper frequency tuning than from the front. Possible mechanisms underlying this direction dependent frequency tuning are discussed.

Action Potentials↗

Coding of sound-source location by ensembles of cortical neurons.

We examined the coding of sound-source location by ensembles of neurons in the auditory cortex. Broadband noise bursts were presented from loudspeakers throughout 360 degrees in the horizontal plane. Sound levels varied from 20 to 40 dB above neural thresholds. We recorded temporal spike patterns simultaneously at 16 recording sites in area A2 of alpha-chloralose-anesthetized cats. Spike patterns of individual units varied in spike counts and in spike timing as a function of sound-source location. Ensembles of up to 19 units recorded simultaneously demonstrated additional location sensitivity in the form of relative spike counts and relative spike timing among neurons. We used an artificial neural network (ANN) algorithm to recognize ensemble spike patterns and, thereby, to infer the locations of sound sources. The ANN could estimate stimulus locations based on ensemble responses to single-stimulus presentations. Median errors (MEs) averaged 49.2 +/- 11.9 degrees (mean +/- SD; n = 34; chance level, 90 degrees ). The ANN maintained better-than-chance performance even when input spike patterns were expressed as relative spike counts across units (i.e., no information available from absolute spike counts of individual units; ME, 63.0 +/- 11.8 degrees ) or when spike latencies were represented as time relative to the first spike for each trial (i.e., no external time reference available; ME, 54.3 +/- 12.4 degrees ). The ANN performance improved monotonically as the sizes of ensemble patterns were increased by combining patterns across the entire unit sample. The performance by ensembles of 128 units approached the level of localization performance of behaving cats.

Action Potentials↗

Sound localization in the human brain: neuromagnetic observations.

Sound location processing in the human auditory cortex was studied with magnetoencephalography (MEG) by producing spatial stimuli using a modern stimulus generation methodology utilizing head-related transfer functions (HRTFs). The stimulus set comprised wideband noise bursts filtered through HRTFs in order to produce natural spatial sounds. Neuromagnetic responses for stimuli representing eight equally spaced sound source directions in the azimuthal plane were measured from 10 subjects. The most prominent response, the cortically generated N1m, was investigated above the left and right hemisphere. We found, firstly, that the HRTF-based stimuli presented from different directions elicited contralaterally prominent N1m responses. Secondly, we found that cortical activity reflecting the processing of spatial sound stimuli was more pronounced in the right than in the left hemisphere.

Acoustic Stimulation↗

Light-sound interaction in the neurons of the rabbit's visual cortex.

One hundred cells of the visual cortex were studied using flashes, clicks and light-sound combinations with different delays. Forty nine neurons changed the total number of spikes to click stimulation. Twenty eight cells responded to clicks with specific response pattern. In 23 cells the initial discharge occurred at 60-70 ms after the onset of clicks. In 39 cells the responses to light-sound combinations differed from the responses to flashes. While 16 cells decreased their responses, the addition of sound increased firing in 23 cells. The specific modification of the light-evoked responses under acoustic stimulation were classified into three main categories: 22 cells generated new response patterns, 18 cells showed a re-distribution of peaks in the PTS histogram and three cells demonstrated a desynchronization of the spike discharge. The study of the heteromodal recovery cycle revealed that the majority of the cells increased their firing during 0-100 ms and decreased firing during 200-300 ms of the response time scale. The critical delays between light and sound, resulting in the modification of the response for the majority of the cells, were within 100 ms in both directions.

Acoustic Stimulation↗

[Early diastolic sound in a patient with hepatocarcinoma].

On physical examination an early diastolic sound is usually associated with mitral stenosis, prosthetic mitral valve replacement and chronic constrictive pericarditis. In case of an atrial myxoma, an early diastolic sound can be usually heard due to movement of the tumor towards the tricuspid valve (tumor plop). The following case report shows an example in which an early diastolic sound was heard in a patient presenting with a hepatocellular carcinoma. This sound was due to the presence of a thrombus that originated from the inferior vena cava and invaded the right atrium up to the tricuspid valve. It was thus similar to an atrial myxoma and produced a tumor plop.

Carcinoma, Hepatocellular↗

Ultrasonic measurement of sound velocity in whole blood. A comparison between an ultrasonic method and the conventional packed-cell-volume test for hematocrit determination.

A new ultrasonic instrument for the determination of sound velocity in tissue is described. The instrument has been used in this investigation to measure the sound velocity in heparinized whole blood samples. The corresponding hematocrit values of the blood samples were determined by the packed cell volume test. The measurements in the hematocrit range of approx. 30-55 indicate a high degree of correlation between the hematocrit value and the respective blood sound velocity (S.E.E.=1.3 and r=0.96). Repeated measurements of the same blood samples up to 1 hr after collection of the blood show very small changes in reading of sound velocity, provided the samples were kept at a constant temperature and well stirred. The ultrasonic measurement is quick and simple to perform, and the blood specimen is not changed by the measuring process.

Electronics, Medical↗

[Temporomandibular joint sounds: a psychological problem?].

In this article the role of psychological variables in the etiology and presentation of temporomandibular joint sounds is studied. It is concluded that psychological differences observed in the literature are most likely not related to temporomandibular joint sounds. These differences probably are an artefact, caused by using self-report as a substitute for the objective presence of symptoms. A comparison between self-report and objective measurement shows that psychological variables are indeed mainly involved in the reporting of temporomandibular joint sounds. When objective measurements are used, no substantial psychological differences are found. A theory is presented that explains the reporting of symptoms from attention and interpretation. Using this theory the reporting of temporomandibular joint sounds can be predicted quite well.

Humans↗

[The evaluation of sound level in dental practice].

Noise pollution is one of the most important problems of the contemporary world. Dentistry is one of the most affected areas because the activity in a dental practice involves the use of different devices that generate noise. The purpose of our study is to evaluate the sound level in a dental practice with 4 dental units using a complex system, which comprises: a Sound Blaster Live 5.1, a Dual microphone, a PC and special software for the acquisition and data analysis. The sound level detected by us is similar with the data from the international literature with some particular aspects and suggests that the dental practice is a noise polluted environment although most of the sound levels are beneath the damaging noise level for the human ear (85 dB).

Dental High-Speed Equipment↗

The effect of occlusal relationships on the occurrence of sounds in the temporomandibular joint.

The aim of this investigation was to determine the influence of occlusal relationships on the occurrence of sounds in the temporomandibular joint. A group of 100 male subjects aged 24-52 years (X = 35.03+/-6.92) was examined. Analysis of occlusion included determination of the number of existing teeth, number of teeth in occlusion, overbite and overjet, type of occlusion, mediotrusion interferences, relationship of the retruded contact position (RCP) to intercuspal position (ICP), and the amount and direction of sliding from RCP to ICP. Sound was registered by means of a stethoscope and classified according to its character in click or crepitation. Sound was present in 29% of subjects. In 28% of cases it was registered as click and in 2% of cases as crepitation. One subject had simultaneous click and crepitation. The results of the statistical analysis indicate that overbite, type of occlusion, existence of mediotrusion interferences, the relationship of RCP to ICP, and the amount and direction of sliding from RCP to ICP do not have an influence on the occurrence of sounds. The risk of the occurrence of crepitation is significantly increased in the case of the loss of more than 5 teeth, and in the case of horizontal overbite larger than 7.5 mm (p<0.05).

Adult↗

Sound delay lines in the nucleus laminaris of the chicken.

Delays of neurophonic potentials (NP) induced by monaural sound stimuli were measured across the three dimensions in the nucleus laminaris (NL) of the anesthetized chicken. Peak latencies and delays in cross-correlograms changed with recording distance. An orderly delay line was observed across the NL thickness, that is, along dendritic trees of individual fusiform cells (FC), where phase lags increased dorso-ventrally during ipsi- and in the opposite direction during contralateral stimuli. Delays along isofrequency FC arrays were variable, with delay ranges being smaller for ipsilateral than for contralateral sound stimuli. Net delays for contralateral sounds were directed medio-laterally and differences between ipsi- and contralateral delays covered, roughly, intercochlear time differences (ITD). The observed delays are thought to contribute to sound localization and frequency analysis.

Animals↗

A study of normal heart sounds, heart size, arterial pressure and electrocardiograms from infancy to early adulthood in one male and one female.

This study forms part of a project to define the range of normal for heart sounds and murmurs. Using the method of writing quantitative symbol phonocardiograms, data were collected on one female and one male subject from earliest infancy to adulthood (aged 27 and 25). Serial measurements of heart size, arterial pressure and records of electrocardiograms and electrophonocardiograms were made. The heart sounds are shorter and somewhat less loud under the age of two years than later. Physiologic splitting of the first and second sounds, a physiologic systolic murmur, the appearance and disappearance of a third sound are shown in the illustrations which epitomize this study. These longitudinal studies of age period changes in the electrocardiogram reveal what has been learned from the horizontal studies. The shape of the cardiac silhouette as recorded between the ages of 5 and 8 years seems to predict the adult shape. The adult type of arterial pressure became established in the early teens.

Adolescent↗

Fractal analysis of tracheal sounds during maximal forced exhalation.

BACKGROUND: Fractal structures or processes, many of which are found in nature, are marked by the presence of a formal pattern that repeats itself even as the scale changes, a property termed 'self-similarity'. The bronchial tree is structurally a fractal system and inspiration is a fractal process. Our objective was to show that the dynamic process of emptying air from the bronchi as measured by tracheal sounds should also behave fractally over the period of time during which exhalation takes place. MATERIAL/METHODS: Twenty non-smoking patients (9 males and 11 females) aged 53.6+/-16.3 years with persistent but clinically stable moderate to severe asthma and a control group of 11 healthy non-smoking subjects (6 males and 5 females) aged 46.0+/-12.5 years were enrolled. Respiratory sounds were registered using a microphone held by an elastic band directly against the patient's skin at the level of the cricoid cartilage. Analysis was done on the average of three forced expirations made after a deep inspiration. The Hurst's coefficient was computed by Hurst's rescaled range analysis (H) and by analysis of the variance-time relationship of the aggregated process (H_v). RESULTS: Values of H and H_v were around 0.75, indicating that the sound signals were fractal over time. The responses of controls and patients to bronchodilator administration of 1 mg terbutaline were similar (p>0.05). Mean intra-subject variation coefficients were less than 15%. CONCLUSIONS: This analysis of tracheal sound during forced expiratory maneuvers confirms the dynamic fractal behavior of the respiratory system.

Adult↗

Time-intensity trade of bilaterally bone-conducted sounds in normal hearing subjects.

OBJECTIVE AND METHODS: In an effort to examine the rules by which information of bilaterally applied bone-conducted signals arising from interaural time differences (ITD) and interaural intensity differences (IID) is combined, data were measured for continuous 500 Hz narrow-band noise at 60 dBHL in 30 normal-hearing subjects using a centering method. Time-intensity trading functions were obtained by means of a sound image shifted towards one side by presenting an ITD, and shifted back to a centered sound image by varying the IID in the same ear. ITD values were varied from -600 to +600 microseconds at 200 microseconds steps, where negative values indicate delays to the right ear. RESULTS: Time-intensity trading functions in response to bone-conducted signals showed significantly lower discrimination thresholds across IIDs, when compared to a control group with applied air-conducted signals. These findings can be interpreted as a constructive interference effect related to the intimate mechanism of bilateral bone conduction, where interaural time differences play a major role. CONCLUSION: Time-intensity trade of bilaterally bone-conducted sounds in normal-hearing subjects is the highly sensitive. The high speed of sound through the skull may be the main reason for the high sensitivity of time-intensity trading.

Adult↗

[The collecting and processing system of the sound signal of larynx].

This paper presents a new kind of collecting and processing system of the sound signal of larynx where double sound cards and software filter are used. The installation of the double sound cards and processing proposal of software are mainly discussed and a new kind of ADC method of dual-channel sound signal is put forward in this paper. This system has the feature of reliable performance, simple installation and easy maintenance.

Algorithms↗

Utilizing lung sounds analysis for the evaluation of acute asthma in small children.

One of the most difficult aspects of management of acute asthma in the small child is the clinician's inability to quantitate the response or lack of response to bronchodilator agents because of the inability of a child this age to perform objective lung measurements in the acute state. The present study was designed to evaluate bronchodilator responsiveness in children between 2 and 6 years of age with wheezing by means of a computerized lung sound analysis, computer digitized airway phonopneumonography. Children between ages 2 and 6 who were experiencing acute exacerbations of asthma were included in this study population. The 43 children were evaluated by physical examination, pulmonary function testing, if possible, by use of (spirometry or peak flow meter) and transmission of lung sounds to a computer using an electronic stethoscope to obtain a phonopneumograph with sound intensity level determinations during tidal breathing. A control group of 20 known asthmatic patients between the ages of 8 and 52 years who also presented to the office with acute asthma were evaluated similarly. In each of these individuals, a physical examination was followed by complete spirometry as well as computer digitized airway phonopneumonography recordings. Following initial measurements, all patients were treated with nebulized albuterol (0.25 mL in 2 mL of saline). Five minutes after completion of the nebulization all patients were reexamined and repeat pulmonary function tests were performed followed by CDAP recordings. In the study group of children, the mean pretreatment sound intensity level was 1,694 (range 557 to 4,950 SD +/- 745).(ABSTRACT TRUNCATED AT 250 WORDS)

Acute Disease↗