Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “STEAM”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87Linked to original sources

Pesticide residue concentrations in the Belgian total diet, 1991-1993.

In the period 1991-1993, an official study was conducted to measure the presence and evaluate the risk of pesticide residues in plantbased food in the Belgian total diet. Positive samples were subjected to one or more culinary treatments (washing, peeling, steaming, or cooking) to determine the decrease of residues in prepared ready-to-eat food. Thus, better estimates of pesticide residues taken up through consumption were determined and compared with toxicological criteria. Washing did not significantly reduce residues. Peeling fruits removed almost all pesticides. The effects of cooking and steaming varied, depending on the type of food and pesticide.

Belgium↗

Condensable chemical vapors for sterilization of freeze dryers.

Sterilization of freeze dryers is usually performed by subjecting them to saturated steam under pressure by steam (121 degrees C, 2 bar a., 30 minutes). In order to avoid such stressful conditions, another process was designed on the basis of a strong oxidizing mixture of condensable chemical vapors, consisting of ozone and hydrogen peroxide in acidic conditions. This process works at sub-zero temperatures up to 30 degrees C and under negative pressure. 10(6), inoculum of standard biological indicators as well as wild types of bioburden were easely sterilized from 2 minutes up to 10 minutes. Other parameters were studied, in order to optimize the main process conditions: temperature, pressure, concentration of chemicals, type of micro-organisms and their environmental surroundings.

Freeze Drying↗

Antimicrobial resistance of three species of Bacillus to thirty various antimicrobial agents.

Three frequently used strains of Bacillus were tested using antimicrobial susceptibility test discs to determine their resistance to various antimicrobial drug agents. The organisms selected were B. subtilis ATCC 6633 (used for USP B and F tests), B. stearothermophilus ATCC 12980 (used as a biological indicator for steam sterilization) and B. coagulans ATCC 51232 (used as a biological indicator for steam sterilization). The results indicated that for the thirty antimicrobial drug agents tested, the only organisms which exhibited any resistance to these agents was B. subtilis, and it only showed resistance to two drugs (Aztreonam and Bacitracin).

Bacillus↗

[Experimental studies of high frequency jet ventilation improved by enhancing expiratory turbulence].

OBJECTIVE: To improve the effect on CO2 elimination during high frequency jet ventilation by enhancing expiratory turbulence. METHODS: Nine healthy dogs with steam-induced type I respiratory failure were basically applied with high frequency jet ventilation (HFJV), and high frequency two-way jet ventilation (HFTJV), HFJV combined with thoracicoabdominal compression (HFJV+TAC), and HFJV combined with thoracicoabdominal compression-decompression (HFJV+ TACD) randomly for 30 min, respectively. The parameters were determined and the Reynolds numbers (NR) were calculated. RESULTS: Reynolds numbers were more than 3000 in all patterns, suggesting that the airflow was turbulent. Expiratory Na was higher. The NR of the latter three patterns was more significantly higher than that of HFJV (P < 0.01). CO2 elimination was 126, 111, 137 ml. min-1 in the latter three patterns, respectively and significant (P < 0.05) or very significant (P < 0.01) compared with 98.0 ml.min-1 in HFJV. Corresponding changes occurred in PaCO2. NO significant differences (P > 0.05) were observed in hemodynamic parameters. CONCLUSION: HFJV combined with inverse jet or thoracicoabdominal compression or decompression on expiratory phase could enhance expiratory turbulence and facilitate CO2 elimination in 9 dogs with steam-induced type I respiratory failure.

Animals↗

The chromosomal effect of birchen dust as determined by the micronucleus test.

In a wood processing factory, the measured air concentration of birchen dust was 1.26 +/- 0.41 mg/m3, and the micronucleus frequency of peripheral blood lymphocytes in 83 workers exposed to wood dust was 1.13 +/- 2.83/1000, which was significantly higher (P < 0.01) than that of control group (0.51 +/- 1.41/1000). The number of exposed workers with positive micronucleus test was 9.6%, which was higher than that of control group (4.5%), but the difference was not significant (P > 0.05). The micronucleus test in mice treated with water extracts of unsteamed and unbaked birchen dust showed that the micronucleus frequencies in all treated groups were significantly higher than that of control group (P < 0.01) and there was also a dose response correlation (r = 0.96, P < 0.0005). The results of steamed and baked birchen dust extracts were significantly lower than those of the unsteamed and unbaked ones at the same doses (P < 0.001). This suggests that when the birchen dust is steamed at the temperature of 100 degrees C for 24 h or baked at the temperature of 80 degrees C, its inducing effect in micronucleus test could be lowered.

Adult↗

[Phytochemical evaluation of essential oils, medicinal plants and their preparations].

A surway is presented on the authors' work in the field of volatile oil research. The gas chromatographic method previously used for analysis of essential oils was transformed to capillary gas chromatographic conditions. The method is also suitable for separation of compound-pairs frequently occurring in essential oils (peppermint, rosemary, lavender, sage, clary sage, thyme oils). Beside the gas chromatographic analysis of essential oils, which was necessary for their standardization and qualification, the influence of different extraction methods and some biological facts e.g. the ontogenesis on the change of essential oil composition are also discussed. It has been established that the water steam distillation from acidic medium can be more advantageous than the traditional one, if the volatile terpene derivatives were bound in form of glycosides or dimeric quajazolide lactons were present in plant (oregano, Sideritis, wormwood oils). Comparing the composition of essential oil obtained by water steam distillation and supercritical fluid extraction (SFE) it was found that the SFE fractions are richer in ester constituents because the possibility of hydrolysis is reduced, and the oils are more valuable than the classic oils. On the other hand, when the transformation processes are important (chamomile), the distillation is the better method. The change of essential oil composition of Ocimum basilicum L. and Anthriscus cerefolium L. was also studied during the vegetation period. It has been established that in budding and early flowering stages the basil oil was rich in monoterpenes; the quantity of sesquiterpenes and phenylpropane derivatives increased only in later stadiums. Finally the extraction and analytical processes are discussed which are used for standardization of complex plant preparations which contained essential oil as active agent and represented various medicinal forms.

Chamomile↗

Role of oxidative enzymatic treatments on enzymatic hydrolysis of softwood.

The impact of oxidative modification and partial removal of lignin by laccase-mediator treatments on the enzymatic hydrolysis of steam-pretreated softwood (SPS) was evaluated. Two mediators, N-hydroxy-N-phenylacetamide (NHA) and its acetylated precursor, were oxidized by the laccase from Trametes hirsuta, and their effects on the activity of cellulolytic enzymes and on the hydrolysis yield of SPS were examined. Both simultaneous and sequential combinations of laccase-mediator treatments with commercial cellulases increased the sugar yield in the enzymatic hydrolysis of SPS. The maximal increase was 21% when a sequential treatment was applied. Laccase treatment alone was also shown to improve hydrolysis. NHA oxidized by laccase inhibited significantly the cellulases of Trichoderma reesei, but the presence of the solid substrate protected the activities against oxidative inactivation. Surface analysis of the lignocellulosic substrate before and after the laccase and cellulase treatments revealed an enrichment of lignin and an increase of carboxylic groups on the surface of the hydrolysis residue.

Amides↗

Sauna habits and related symptoms in Finnish children.

Fifteen hundred randomly chosen Finnish children aged 0-15 years were studied by a questionnaire about their sauna habits and possible abnormal symptoms during or immediately after the sauna. A total of 1247 families (83%) answered. Almost all children visited the sauna (98.5%), most of them "with pleasure" (83%). Nearly half of the children were in the sauna as often as 2-3 times a week, and over 90% at least once a week. The children's sauna visits began quite early, in 70% during infancy. The time spent in a hot steam bath increased with age. Symptoms were rare and were not serious. Transient symptoms (dizziness, nausea etc.) were the most common. Of the children, 17% had some chronic or recurring disorder, most commonly atopic dermatitis or middle ear infections. In half of the cases of atopic dermatitis it became worse in the sauna. Sauna is a very common practice in Finland, also among children. It does not seem to cause any significant immediate harm to healthy children.

Adolescent↗

Cutting effectiveness of diamond instruments subjected to cyclic sterilization methods.

The effect of repeated sterilization on the cutting effectiveness of one brand of rotary dental diamond cutting instruments was measured. Four groups of five diamond burs were sterilized by four methods: (1) sterilization with a chemical agent (Sporicidin); (2) steam under pressure (autoclave); (3) dry heat (Dri-Clave); or (4) chemical vapor (Chemiclave). Each group of diamond instruments made a timed cut in a ceramic block. This cut and all subsequent cuts were measured and were used to determine a baseline cutting effectiveness. Each group of diamond burs was then ultrasonically cleaned, sterilized, and another cut was made. At the end of 10 cycles there was no difference in cutting efficiency of the dental diamond instruments. However, there are differences in the cutting efficiency of individual diamond instruments. The SEM evaluation made prior to cutting and at the end of the 10 cycles of sterilization demonstrated that diamond wear was similar in all groups and that little diamond particle loss occurred in any group.

Analysis of Variance↗

Tissue response to commercial silicone and polyurethane elastomers after different sterilization procedures.

Two different commercial polymeric materials, a silicone and a polyurethane (PUR), were studied with regard to correlations between the chemical and physical compositions of the polymer surfaces and the biological response on implantation. Test specimens of the materials were manufactured according to standard procedures. The specimens were implanted in rats for 10 and 90 days. Before implantation the polymers were sterilized in three different ways, namely, beta irradiation, ethylene oxide sterilization and steam sterilization. The polymers were characterized before and after the implantation with respect to the chemical composition and the morphology of the surfaces. After implantation the biological response was evaluated by counting numbers of macrophages, giant cells, fibroblasts and other cells present at the surfaces. The thickness of the fibrous capsule surrounding the test specimens was measured at the thickest and thinnest parts. PUR surfaces showed signs of degradation already after sterilization and after 10 to 90 days of implantation, pits and cracks appeared, especially in the ethylene oxide sterilized samples. However, differences in the biological responses were small and independent of the sterilization method. After 10 days of implantation the capsule thickness and the amounts of cell material adhering at the surfaces were different, and it appears that the silicone rubber induces more tissue response than PUR. The differences in the early tissue response evened out after 90 days implantation time and a steady state situation evolved, which was similar for the silicone and the polyurethane.

Animals↗

The effect of clinical use and sterilization on selected orthodontic arch wires.

The effect of clinical use and various sterilization/disinfection protocols on three types of nickel-titanium, and one type each of beta-titanium and stainless steel arch wire was evaluated. The sterilization/disinfection procedures included disinfection alone or in concert with steam autoclave, dry heat, or cold solution sterilization. No clinically significant differences were found between new and used arch wires. The direction of load application to the arch wire and the particular segment of arch wire tested was found to cause substantial differences in generated loads for certain arch wire types.

Analysis of Variance↗

Select metal adsorption by activated carbon made from peanut shells.

Agricultural by-products, such as peanut shells, contribute large quantities of lignocellulosic waste to the environment each growing season; but few, if any, value-added uses exist for their disposal. The objective of this study was to convert peanut shells to activated carbons for use in adsorption of select metal ions, namely, cadmium (Cd2+), copper (Cu2+), lead (Pb2+), nickel (Ni2+) and zinc (Zn2+). Milled peanut shells were pyrolyzed in an inert atmosphere of nitrogen gas, and then activated with steam at different activation times. Following pyrolysis and activation, the carbons underwent air oxidation. The prepared carbons were evaluated either for adsorption efficiency or adsorption capacity; and these parameters were compared to the same parameters obtained from three commercial carbons, namely, DARCO 12x20, NORIT C GRAN and MINOTAUR. One of the peanut shell-based carbons had metal ion adsorption efficiencies greater than two of the three commercial carbons but somewhat less than but close to Minotaur. This study demonstrates that peanut shells can serve as a source for activated carbons with metal ion-removing potential and may serve as a replacement for coal-based commercial carbons in applications that warrant their use.

Adsorption↗

Reducing nitric oxide into nitrogen via a radio-frequency discharge.

NO/N(2)/O(2)/H(2)O mixtures are usually converted into HNO(3) and/or NO(2) using different discharge approaches. In this study, a radio-frequency discharge was successfully used to reduce NO mainly into N(2) at a low pressure (4kPa). The influences of experimental parameters, including carrier gas, inlet concentration of NO, O(2), steam, and applied power, are discussed. At least 95.7% of the total N atoms converted from NO into N(2). Other traces of byproducts were N(2)O and HNO(2), but neither HNO(3) nor NO(2) were detected. In addition, conversion of NO apparently increased with elevated applied power or decreased inlet concentration of O(2), reaching 92.8% and 74.2% for the NO/N(2)/O(2) (2%) and NO/N(2)/O(2) (6%)/H(2)O (10%) mixtures, respectively, at 120W. In addition, from the optical emission spectra, a large amount of N(2) (first positive band and second positive band) and NO (gamma system) were observed, and the important reactions for NO removal and N(2) formation are proposed.

Air Pollutants↗

Analysis of volatile components of Curcuma sichuanensis X. X. Chen by gas chromatography-mass spectrometry.

Volatile components of Curcuma sichuanensis X. X. Chen growing in Sichuan, China, were extracted by steam distillation and analyzed by using gas chromatography and gas chromatography-mass spectrometry. A total of 44 volatile essential oil components were identified in the extract of C. sichuanensis X. X. Chen, representing 87.1% of the total integrated chromatographic peaks. The major compounds were found to be epi-curzerenone (26.9%), germacrone (12.4%), isocurcumenol (9.7%), beta-elemene (6.4%) and curzerene (6.2%). The results of semi-quantitative analysis indicated that levels of total sesquiterpene fraction (85.4%) were more than 55 times higher than those of monoterpene components (1.5%).

China↗

Inactivation of Cryptosporidium parvum oocyst infectivity by disinfection and sterilization processes.

BACKGROUND: Cryptosporidium parvum is a common cause of self-limited gastroenteritis in the normal host but may cause severe disease in immunocompromised persons. Person-to-person transmission has been well documented in households, child care centers, and hospitals. Because contaminated environmental surfaces and medical devices such as endoscopes may play a role in disease transmission, we studied the susceptibility of C parvum to chemical agents commonly used for disinfection and evaluated the efficacy of sterilization processes. METHODS: Seven disinfectants were studied at their use dilution using a suspension test. Antimicrobial activity was assessed with the use of a cell infectivity assay. RESULTS: All sterilization processes tested (steam, ethylene oxide, Sterrad 100) inactivated 3 logs or greater of C parvum. The only liquid disinfectant/sterilant able to inactivate greater than 3 logs of C parvum was 6% and 7.5% hydrogen peroxide. Agents that did not completely inactivate C parvum included hydrogen peroxide at lower concentrations or exposure times, peracetic acid, sodium hypochlorite, a phenolic, a quaternary ammonium compound, 2% glutaraldehyde, and ortho-phthalaldehyde. CONCLUSIONS: Most high-level disinfectants used on endoscopes have limited efficacy against C parvum. However, the infectivity of C parvum on dry surfaces decreases rapidly. Therefore, current cleaning and high-level disinfection guidelines are adequate to prevent nosocomial transmission of C parvum by means of endoscopes.

Animals↗

Biomechanical properties of sterilized human auditory ossicles.

Bone allograft material is treated with sterilization methods to prevent the transmission of diseases from the donor to the recipient. The effect of some of these treatments on the integrity of the bone is unknown. This study was performed to evaluate the effect of several sterilization methods on the mechanical behaviour of human middle ear bones. Due to the size and composition of the bones (approximately 1.5 mm diameter by 4 mm long), mechanical testing options were limited to the traditional platens compression test. Experiments were first performed with synthetic bone to evaluate the precision of this test applied to small specimens. Following this, fresh frozen human ossicles were thawed and sterilized with (i) 1 N NaOH (n = 12); (ii) 0.9% LpH, a phenolic solution (n = 12); or (iii) steam at 134 degrees C (n = 18). A group of 26 control specimens did not receive any sterilization treatment. Material and structural properties were determined from axial compression testing. Results from the synthetic bone showed that the test was reproducible, with standard deviations less than 20% of the means. Significant differences occurred in stiffness and ultimate force values between NaOH-treated and autoclaved bones when compared to normals (p<0.05), but not for LpH-treated bones. LpH is not approved for medical use, so NaOH is the most appropriate of the treatments studied for the sterilization of ossicle allografts.

Analysis of Variance↗

Effects of infection control procedures on the accuracy of a new mechanical torque wrench system for implant restorations.

Loosening of screw components for implant restorations has been attributed to insufficient tightening. The degree of tightening may be increased and more closely controlled by use of calibrated mechanical torque wrenches. The DynaTorq wrench system has been introduced to the market and consists of three individual wrenches with torque values of 10, 20, and 30 newton-centimeters (Ncm). This study evaluated the accuracy of the DynaTorq wrench system before and after steam autoclave and Chemiclave sterilization treatment. Before sterilization treatments, the wrenches demonstrated high accuracy and precision. Autoclaving resulted in increases in torque values for the 10 Ncm torque wrench compared with baseline measurements. Except for the effect of autoclaving on the 10 Ncm torque wrench, sterilization procedures did not adversely affect the accuracy of the DynaTorq torque wrench system.

Bone Screws↗