Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Compression Algorithms”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87Linked to original sources

Comparative study of the influence of anode and filter materials on primary shielding requirements for mammography.

Comparison of primary shielding requirements for mammography x-ray beams that are transmitted through different filter materials at equivalent thicknesses has been carried out. In this study, the primary shielding requirement is that which is additional to that provided by the compression paddle, breast tissue, grid and image receptor. Equivalent thickness is defined as the thickness of a filter material (with Z-value between 37 and 55) that will reduce either intensity or total energy or exposure of a given unfiltered incident beam by the same extent or produce equal hardening of the same unfiltered beam as a reference filter (0.03 g cm Mo). The unfiltered incident beams used are those generated by molybdenum (Mo) and tungsten (W) anodes at kVp's of 18, 20, 22,..,42. In most cases (especially for filter with Z-values greater than 42 and values of operating potential greater than 22 kVp), results show that no single thickness was found that could simultaneously match intensity, total energy, exposure, and hardening as the reference filter. There are significant disparities in the values of the additional primary shielding requirements for beams transmitted through the equivalent thicknesses. Structures of the computer software programs (MAFHAMS and MAXRAPS) used to execute the models developed for the computations of the additional primary shielding requirements for the 'equalized' beams are presented.

Algorithms↗

Limitations of the standard linear solid model of intervertebral discs subject to prolonged loading and low-frequency vibration in axial compression.

The purpose of this study was to answer the following questions: (1) Can the standard linear solid model for viscoelastic material simulate the influence of disc level and degeneration on the ability of a disc to withstand prolonged loading and low-frequency vibration? (2) How well does the SLS model explain the relationship between the ability of a disc to resist prolonged loading and its ability to resist dynamic loads and dissipate energy when subjected to low-frequency vibration? Responses of human thoracic and lumbar discs were measured in axial compression under a constant load, and for cyclic deformations at three frequencies. Parameters of the SLS model for each disc were determined by a least-squares fit to the experimental creep response. The model was subsequently used to predict the disc's response to cyclic deformations. The SLS model was able to qualitatively simulate the effects of disc level and degeneration on the ability of an intervertebral disc to resist both prolonged loading and low-frequency vibration. However, the model underestimated the stress relaxation, dynamic modulus and hysteresis of thoracic and lumbar discs subjected to low-frequency vibration. The SLS model was unable to explain the relationship between the ability of a disc to resist prolonged loading and its ability to resist dynamic loads and dissipate energy when subjected to low-frequency vibration. Although in the lumbar discs the steady-state predictions of the SLS model were significantly correlated to the experimental response, the strength of model predictions decreased with increasing frequency, particularly for hysteresis.

Adult↗

2-D ultrasound strain images for breast cancer diagnosis using nonrigid subregion registration.

Tissue elasticity of a lesion is a useful criterion for the diagnosis of breast ultrasound (US). Elastograms are created by comparing ultrasonic radio-frequency waveforms before and after a light-tissue compression. In this study, we evaluate the accuracy of continuous US strain image in the classification of benign from malignant breast tumors. A series of B-mode US images is applied and each case involves 60 continuous images obtained by using the steady artificial pressure of the US probe. In general, after compression by the US probe, a soft benign tumor will become flatter than a stiffened malignant tumor. We proposed a computer-aided diagnostic (CAD) system by utilizing the nonrigid image registration modality on the analysis of tumor deformation. Furthermore, we used some image preprocessing methods, which included the level set segmentation, to improve the performance. One-hundred pathology-proven cases, including 60 benign breast tumors and 40 malignant tumors, were used in the experiments to test the classification accuracy of the proposed method. Four characteristic values--normalized slope of metric value (NSM), normalized area difference (NAD), normalized standard deviation (NSD) and normalized center translation (NCT)--were computed for all cases. By using the support vector machine, the accuracy, sensitivity, specificity and positive and negative predictive values of the classification of continuous US strain images were satisfactory. The A(z) value of the support vector machine based on the four characteristic values used for the classification of solid breast tumors was 0.9358.

Adult↗

Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function.

BACKGROUND: Central aortic pressures and waveform convey important information about cardiovascular status, but direct measurements are invasive. Peripheral pressures can be measured noninvasively, and although they often differ substantially from central pressures, they may be mathematically transformed to approximate the latter. We tested this approach, examining intersubject and intrasubject variability and the validity of using a single averaged transformation, which would enhance its applicability. METHODS AND RESULTS: Invasive central aortic pressure by micromanometer and radial pressure by automated tonometry were measured in 20 patients at steady state and during hemodynamic transients (Valsalva maneuver, abdominal compression, nitroglycerin, or vena caval obstruction). For each patient, transfer functions (TFs) between aortic and radial pressures were calculated by parametric model and results averaged to yield individual TFs. A generalized TF was the average of individual functions. TFs varied among patients, with coefficients of variation for peak amplitude and frequency at peak amplitude of 24.9% and 16.9%, respectively. Intrapatient TF variance with altered loading (> 20% variation in peak amplitude) was observed in 28.5% of patients. Despite this, the generalized TF estimated central arterial pressures to < or = 0.2 +/- 3.8 mm Hg error, arterial compliance to 6 +/- 7% accuracy, and augmentation index to within -7% points (30 +/- 45% accuracy). Individual TFs were only marginally superior to the generalized TF for reconstructing central pressures. CONCLUSIONS: Central aortic pressures can be accurately estimated from radial tonometry with the use of a generalized TF. The reconstructed waveform can provide arterial compliance estimates but may underestimate the augmentation index because the latter requires greater fidelity reproduction of the wave contour.

Abdomen↗

An atomic force microscopy study of the effect of nanoscale contact geometry and surface chemistry on the adhesion of pharmaceutical particles.

PURPOSE: To understand differences in particle adhesion observed with increasing humidity between samples of salbutamol sulfate prepared by two different methods. METHODS: Atomic force microscopy (AFM) force measurements were performed as a function of humidity (<10% to 65% RH) using two systems. The first system used clean AFM tips against compressed disks of micronized and solution enhanced dispersion by supercritical fluid (SEDS) salbutamol. The second system involved particles of both salbutamol samples mounted onto the apexes of AFM cantilevers, and force measurements being performed against a highly orientated pyrolytic graphite (HOPG) substrate. Following these measurements, the contact asperities of the tips were characterized. RESULTS: The first system showed a maximum in the observed adhesion at 22% relative humidity (RH) for the SEDS salbutamol compared to 44% RH for the micronized salbutamol. The second system showed a mix of peaks and continual increases in adhesion with humidity. The predicted Johnson-Kendall-Roberts forces were calculated and divided by the actual forces in order to produce a ratio. CONCLUSIONS: By relating the nature of the asperities to the force measurements, we propose a model in which adhesion scenarios range from single asperity nanometer-scale contact in which peaks in the adhesion were observed, to multiasperity contact where a continuous increase in adhesion was seen with humidity.

Adhesiveness↗

Evaluation of dual-energy subtraction of digital mammography images under conditions found in a commercial unit.

Radiological contrast-to-noise ratio (CNR) is evaluated in subtracted images of microcalcifications in breast tissue. CNR is calculated for dual-kVp subtraction combining beams available in a Senographe 2000D, assuming single breast compression. Spectra were obtained from Boone et al (1997 Med. Phys. 24 1863-73), and the study was limited to lowest 25 kV Mo/Mo and highest 40 kV Rh/Rh beams, for 2.58 x 10(-4) C kg(-1) (1R) total exposure. For a standard case combining 25 kVp Mo/Mo and 40 kVp Rh/Rh beams, predicted maximum CNR for 300 microm calcification in 5 cm thick, 50% glandular, breast is about 1.2, below Rose's criterion for visualization. Total mean glandular doses are about 2.5 cGy for a standard case. The effect that input factors might have on predictions has been evaluated. Choice between alternative spectra can affect CNR by 50%. Assumed calcification composition leads to differences of 67% in calculated CNR, and assumed breast tissue composition can alter CNR by 45%; these results are weakly dependent on calcification or breast thickness, or on the assumed fraction of glandular tissue. CNR values are related to detected spectra effective energy. Calculations predict that above 37 kVp Mo/Mo beams are more energetic than Rh/Rh at the same kVp, due to beam hardening.

Absorptiometry, Photon↗

Sensitivity and specificity of a rapid whole-blood assay for D-dimer in the diagnosis of pulmonary embolism.

BACKGROUND: Patients with suspected pulmonary embolism often have nondiagnostic lung scans and may present in circumstances where lung scanning is unavailable. Levels of D-dimer, a fibrin-specific product, are increased in patients with acute thrombosis; this may simplify the diagnosis of pulmonary embolism. OBJECTIVE: To determine the sensitivity and specificity of a whole-blood D-dimer assay in patients with suspected pulmonary embolism and in subgroups of patients with low pretest probability of pulmonary embolism or nondiagnostic lung scans. DESIGN: Prospective cohort. SETTING: Four tertiary care hospitals. PATIENTS: 1177 consecutive patients with suspected pulmonary embolism. MEASUREMENTS: All patients underwent an assessment of pretest probability by use of a standardized clinical model, a D-dimer assay, ventilation-perfusion lung scanning, and bilateral compression ultrasonography. Patients in whom pulmonary embolism was not initially diagnosed were followed for 3 months. Accordingly, patients were categorized as positive or negative for pulmonary embolism. RESULTS: Of the 1177 patients, 197 (17%) were classified as positive for pulmonary embolism. Overall, the D-dimer assay showed a sensitivity of 84.8% and a specificity of 68.4%. In 703 patients (3.4%) with a low pretest probability of pulmonary embolism, the likelihood ratio associated with a negative D-dimer test result was 0.27, resulting in a posterior probability of 1.0% (95% CI, 0.3% to 2.2%). In 698 patients with nondiagnostic lung scans (previous probability, 7.4%), the likelihood ratio associated with a negative D-dimer test result was 0.36, resulting in a posterior probability of 2.8% (CI, 1.4% to 4.8%). CONCLUSIONS: A normal D-dimer test result is useful in excluding pulmonary embolism in patients with a low pretest probability of pulmonary embolism or a nondiagnostic lung scan.

Algorithms↗

Solution structure of a conserved DNA sequence from the HIV-1 genome: restrained molecular dynamics simulation with distance and torsion angle restraints derived from two-dimensional NMR spectra.

The three-dimensional solution structure of a trisdecamer DNA duplex sequence, d(AGCTTGCCTTGAG).d(CTCAAGGCAAGCT), from a conserved region of HIV-1 genome's long terminal repeat, has been investigated using NMR spectroscopy and restrained molecular dynamics calculations. Interproton distances derived from two-dimensional nuclear Overhauser enhancement (2D NOE) experiments, using the iterative complete relaxation matrix algorithm MARDIGRAS, and torsion angles for sugar rings, estimated from stimulated fitting of double-quantum-filtered correlation (2QF-COSY) spectra, were obtained [Mujeeb, A., Kerwin, S. M., Egan, W. M., Kenyon, G. L., & James, T. L. (1992) Biochemistry 31, 9325-38]. These structural restraints have now been employed as the basis for structure refinement using restrained molecular dynamics (rMD) to search conformational space for structures consistent with the experimental restraints. Specifically, upper and lower bounds on the restraints were incorporated into the AMBER (version 4.0) total potential energy function of the system, the bounds being used to define the width of a flat-well penalty term in the AMBER force field. Confidence in the time-averaged structure obtained is engendered by convergence to essentially the same structure (root-mean-square deviation approximately 0.9 A) when two quite different DNA models, A-DNA and B-DNA (RMSD approximately 6.5 A), were employed as starting structures and when various initial trajectories were used for the rMD runs. The derived structure is further supported by the total energy calculated, the restraint violation energy, the restraint deviations, and the fit with experimental data. For the latter, the sixth-root residual index indicated a good fit of the determined structure with experimental 2D NOE spectral intensities (R1x < 0.07), and the RMS difference between vicinal proton coupling constants calculated for the derived structure and experimental coupling constants were also in reasonable agreement (JRMS = 0.9 Hz). While the structure of the trisdecamer is basically in the B-DNA family, some structural parameters manifest interesting local variations. The helix parameters indicate that, compared with classical B-DNA, the structure is longitudinally more compressed. Local structural variations at the two TG steps in particular together create bending into the major groove of the duplex. Comparison of the two-CTTG-tetrads in the duplex reveals that they have similar structures, with the TT moieties being almost identical; however, the -CTTG-pur sequence has a larger roll and slide for the -TG- step than for the -CTTG-pyr sequence, in accord with published X-ray crystallographic conclusions.

Base Sequence↗

Modelling the phase equilibria in two-component membranes of phospholipids with different acyl-chain lengths.

A phenomenological model is proposed to describe the membrane phase equilibria in binary mixtures of saturated phospholipids with different acyl-chain lengths. The model is formulated in terms of thermodynamic and thermomechanic properties of the pure lipid bilayers, specifically the chain-melting transition temperature and enthalpy, the hydrophobic bilayer thickness, and the lateral area compressibility modulus. The model is studied using a regular solution theory made up of a set of interaction parameters which directly identify that part of the lipid-lipid interaction which is due to hydrophobic mismatch of saturated chains of different lengths. It is then found that there is effectively a single universal interaction parameter which, in the full composition range, describes the phase equilibria in mixtures of DMPC/DPPC, DPPC/DSPC, DMPC/DSPC, and DLPC/DSPC, in excellent agreement with experimental measurements. The model is used to predict the variation with temperature and composition of the specific heat, as well as of the average membrane thickness and area in each of the phases. Given the value of the universal interaction parameter, the model is then used to predict the phase diagrams of binary mixtures of phospholipids with different polar head groups, e.g., DPPC/DPPE, DMPC/DPPE and DMPE/DSPC. By comparison with experimental results for these mixtures, it is shown that difference in acyl-chain lengths gives the major contribution to deviation from ideal mixing. Application of the model to mixtures with non-saturated lipids is also discussed.

Algorithms↗

Ultrafast two-dimensional NMR spectroscopy using constant acquisition gradients.

Multidimensional NMR spectroscopy plays an important role in the characterization of molecular structure and dynamics. A new methodology for acquiring this kind of spectra has been recently demonstrated, endowed with the potential to compress arbitrary multidimensional NMR acquisitions into a single scan. This "ultrafast" nD acquisition protocol is based on a spatiotemporal encoding of the indirect-domain spin evolution, followed by a repetitive decoding and re-encoding of the information thus stored employing a train of alternating-sign gradients. Such train of switching gradients extending throughout the course of the data acquisition may pose extreme demands on a magnetic resonance system, particularly when dealing with nonshielded gradients, strong eddy currents, or rapidly relaxing spin systems. Limits to the in vivo applicability of such fast-switching scheme may also arise due to gradient-induced perineural stimulation. The present study describes a new approach to ultrafast nD NMR that reduces the number of gradient switchings during the acquisition period to zero, leading in essence to a constant-gradient acquisition scheme. This approach operates on the basis of a novel spatiotemporal encoding including discrete, temporally overlapping, frequency-shifted pulses. Principles and examples of this new approach are given; sensitivity limitations and signal-enhancing prospects of such constant-gradient acquisitions are also discussed and exemplified.

Algorithms↗

High-resolution scintimammography improves the accuracy of technetium-99m methoxyisobutylisonitrile scintimammography: use of a new dedicated gamma camera.

The main disadvantage of technetium-99m methoxyisobutylisonitrile (MIBI) prone scintimammography is its limited sensitivity for T1a and T1b cancers with a size of less than 1 cm. We have developed a high-resolution scintimammographic technique using a gamma camera based on a new concept, namely a position-sensitive photo-multiplier tube. The field of view of this camera, previously known as the SPEM (single photon emission mammography) camera, was 10 cm diameter. Scintimammographic images were acquired in the axial view; each breast was compressed to a thickness of 3-6 cm, modal class 4 cm. When the compressed breast was larger than the field of view, more than one study was performed in order to image the entire gland. Fifty-three patients were studied with high-resolution-scintimammography (HRSM) and Anger camera prone scintimammography (ACPSM). HRSM was performed 70 min after i.v. administration of 740 Mbq of (99m)Tc-MIBI; ACPSM images were acquired 10 and 60 min following the injection. Early 10-min ACPSM images were only evaluated for routine diagnostic purposes, while comparison was carried out between the 60-min ACPSM and 70-min HRSM images. At fine-needle aspiration (FNA) and/or open biopsy, 31 patients showed cancer: 15 T1c, 11 T1b and 5 T1a. In T1a-T1b cancers, the sensitivity of scintimammography was 50% with ACPSM and 81.2% with HRSM (P<0.01). Specificity was 86% with both techniques. HRSM is a promising new technique that improves the sensitivity of (99m)Tc-MIBI scintimammography in tumours sized less than 1 cm without apparently reducing its specificity. We are now working on a larger field-of-view camera.

Aged↗

Magnetic resonance elastography using 3D gradient echo measurements of steady-state motion.

Magnetic resonance elastography (MRE) is an important new method used to measure the elasticity or stiffness of tissues in vivo. While there are many possible applications of MRE, breast cancer detection and classification is currently the most common. Several groups have been developing methods based on MR and ultrasound (US). MR or US is used to estimate the displacements produced by either quasi-static compression or dynamic vibration of the tissue. An important advantage of MRE is the possibility of measuring displacements accurately in all three directions. The central problem in most versions of MRE is recovering elasticity information from the measured displacements. In previous work, we have presented simulation results in two and three dimensions that were promising. In this article, accurate reconstructions of elasticity images from 3D, steady-state experimental data are reported. These results are significant because they demonstrate that the process is truly three-dimensional even for relatively simple geometries and phantoms. Further, they show that the integration of displacement data acquisition and elastic property reconstruction has been successfully achieved in the experimental setting. This process involves acquiring volumetric MR phase images with prescribed phase offsets between the induced mechanical motion and the motion-encoding gradients, converting this information into a corresponding 3D displacement field and estimating the concomitant 3D elastic property distribution through model-based image reconstruction. Fully 3D displacement fields and resulting elasticity images are presented for single and multiple inclusion gel phantoms.

Algorithms↗

Mechanical behavior of damaged trabecular bone.

The mechanical behavior of damaged trabecular bone may play a role in the etiology of age-related spine fractures since damaged bone exists in and may weaken the elderly vertebral body. To describe some characteristics of damaged trabecular bone, we measured the changes in modulus and strength that occur when bovine trabecular bone is loaded in compression to various strains beyond its elastic range. Twenty-three reduced-section specimens, taken from 17 different bones, were loaded from 0-X-0-9% strain, where X was one of four strains: 1.0% (n = 7), 2.5% (n = 6), 4.0% (n = 5), or 5.5% (n = 5). We found that modulus was reduced for all applied strains, whereas strength was reduced only for strain levels > or = 2.5%; the percentage changes in modulus and strength were independent of Young's modulus but were highly dependent on the magnitude of the applied strains; modulus was always reduced more than strength; and simple statistical models, using knowledge of only the applied strains, predicted well the percentage reductions in modulus (r2 = 0.97) and strength (r2 = 0.74). The modulus reductions reported here are in qualitative agreement with those for cortical bone in tensile loading, supporting the concept that the damage behaviors of cortical and trabecular bone are similar for low strains (< or = 4.0%). In addition, because modulus was always reduced more than strength, damaged trabecular bone may be stress protected in vivo by redistribution of stresses to undamaged bone.

Algorithms↗

Ultrasound elastomicroscopy using water jet and osmosis loading: potentials for assessment for articular cartilage.

Research in elasticity imaging typically relies on 1-10 MHz ultrasound. Elasticity imaging at these frequencies can provide strain maps with a resolution in the order of millimeters, but this is not sufficient for applications to skin, articular cartilage, or other fine structures. In this paper, we introduced two methods of ultrasound elastomicroscopy using water jet and osmosis loading for imaging the elasticity of biological soft tissues with high resolutions. In the first system, the specimens were compressed using water jet compression. A water jet was used to couple a focused 20 MHz ultrasound beam into the specimen and meanwhile served as a "soft" indenter. Because there was no additional attenuation when propagating from the ultrasound transducer to the specimen, the ultrasound signal with high signal-to-noise ratio could be collected from the specimens simultaneously with compressing process. The compression was achieved by adjusting the water flow. The pressure measured inside the water pipe and that on the specimen surface was calibrated. This system was easily to apply C-scan over sample surfaces. Experiments on the phantoms showed that this water jet indentation method was reliable to map the tissue stiffness distribution. Results of 1D and 2D scanning on phantoms with different stiffness are reported. In the second system, we used osmotic pressure caused by the ion concentration change in the bathing solutions for the articular cartilage to deform them. When bovine articular cartilage specimens were immerged in solutions with different salt concentration, a 50 MHz focused ultrasound beam was used to monitor the dynamic swelling or shrinkage process. Results showed that the system could reliably map the strain distribution induced by the osmotic loading. We extract intrinsic layered material parameters of the articular cartilage using a triphasic model. In addition to biological tissues, these systems have potential applications for the assessment of bioengineered tissues, biomaterials with fine structures, or some engineering materials. Further studies are necessary to fully realize the potentials of these two new methods.

Algorithms↗

Quality assurance of HDR prostate plans: program implementation at a community hospital.

Adenocarcinoma of the prostate is currently the most commonly diagnosed cancer in men in the United States, and the second leading cause of cancer mortality. The utilization of radiation therapy is regarded as the definitive local therapy of choice for intermediate- and high-risk disease, in which there is increased risk for extracapsular extension, seminal vesicle invasion, or regional node involvement. High-dose-rate (HDR) brachytherapy is a logical treatment modality to deliver the boost dose to an external beam radiation therapy (EBRT) treatment to increase local control rates. From a treatment perspective, the utilization of a complicated treatment delivery system, the compressed time frame in which the procedure is performed, and the small number of large dose fractions make the implementation of a comprehensive quality assurance (QA) program imperative. One aspect of this program is the QA of the HDR treatment plan. Review of regulatory and medical physics professional publications shows that substantial general guidance is available. We provide some insight to the implementation of an HDR prostate plan program at a community hospital. One aspect addressed is the utilization of the low-dose-rate (LDR) planning system and the use of existing ultrasound image sets to familiarize the radiation therapy team with respect to acceptable HDR implant geometries. Additionally, the use of the LDR treatment planning system provided a means to prospectively determine the relationship between the treated isodose volume and the product of activity and time for the department's planning protocol prior to the first HDR implant. For the first 12 HDR prostate implants, the root-mean-square (RMS) deviation was 3.05% between the predicted product of activity and time vs. the actual plan values. Retrospective re-evaluation of the actual implant data reduced the RMS deviation to 2.36%.

Algorithms↗

Sharpen&Bend: recovering curved sharp edges in triangle meshes produced by feature-insensitive sampling.

Various acquisition, analysis, visualization, and compression approaches sample surfaces of 3D shapes in a uniform fashion without any attempt to align the samples with sharp edges or to adapt the sampling density to the surface curvature. Consequently, triangle meshes that interpolate these samples usually chamfer sharp features and exhibit a relatively large error in their vicinity. We present two new filters that improve the quality of these resampled models. EdgeSharpener restores the sharp edges by splitting the chamfer edges and forcing the new vertices to lie on intersections of planes extending the smooth surfaces incident upon these chamfers. Bender refines the resulting triangle mesh using an interpolating subdivision scheme that preserves the sharpness of the recovered sharp edges while bending their polyline approximations into smooth curves. A combined Sharpen&Bend postprocessing significantly reduces the error produced by feature-insensitive sampling processes. For example, we have observed that the mean-squared distortion introduced by the SwingWrapper remeshing-based compressor can often be reduced by 80 percent executing EdgeSharpener alone after decompression. For models with curved regions, this error may be further reduced by an additional 60 percent if we follow the EdgeSharpening phase by Bender.

Algorithms↗

Effort thrombosis (Paget-Schroetter syndrome) in active young adults: current concepts in diagnosis and treatment.

Effort thrombosis or Paget-Schroetter syndrome most often affects young, active adults who are engaged in sports activities or whose professions require repetitive arm movements causing trauma to the axillary-subclavian vein and precipitating deep vein thrombosis. The presence of unilateral edema in the upper extremity is often thought to be attributable to trauma from an exercise regimen rather than acute deep vein thrombosis or compression of the subclavian vein by extrinsic anatomic structures. Because this syndrome occurs in young, active adults it has the potential for considerable long-term morbidity if it remains undetected or inadequately treated. Inadequate or inappropriate treatment may cause a loss of productivity over a lifetime and significantly affect the quality of life. Although more prevalent in male athletes, it is now increasingly affecting young women as they become more seriously involved in athletic endeavors. The purpose of this article is to increase the awareness of the prevalence, clinical significance, and importance of early detection of effort thrombosis of the axillary-subclavian vein, also known as Paget Schroetter syndrome, to educate health care providers regarding the limitations of some diagnostic tools, and to introduce new methods of treatment that offer better long-term results. The prevalence, differential diagnosis, diagnostic modalities, and medical and surgical interventions that have been successfully used to treat Paget-Schroetter syndrome are discussed, and evidence is provided to support the selections. The results of patients who were identified and treated within the last 2 years at the University of Southern California Center for Vascular Care are reviewed.

Adult↗

Spinal metastasis in the elderly.

Bony metastases are a frequent problem in elderly patients affected by cancer, and those with bony metastases involve the spine in approx. 50%. The most frequent spinal metastases (60%) are from breast, lung, or prostate cancer. The chance that an elderly patient (60-79 years old) is affected by bony metastases is four times higher in men and three times higher in women than a middle-aged patient (40-59 years old). Since the medical treatment with all the adjuvant treatment options prolong the survival of this particular patient group, the spinal metastases may become a mechanical issue, thus requesting surgical treatment. Different classification systems have been proposed to rationalize surgical indications, some concentrating solely on the local spinal tumor involvement and some including the overall clinical situation. Since most of the surgical options are of palliative character, it is more important to base the decision on an overall clinical classification including the different treatment modalities-irradiation, chemotherapy, steroids, bisphosphonates, and surgery-to make a shared decision. In case surgery is indicated-neural compression, pathological fracture, instability, and progressive deformity, nursing reasons-the most straightforward procedures should be chosen, which may not need an intensive care unit stay. In the thoracolumbar spine a posterior decompression and posterolateral vertebral body resection through a posterior approach only, with a concomitant reconstruction and stabilization, has shown to work sufficiently well. In the middle and lower cervical spine the anterior approach with anterior decompression and anterior column reconstruction is most effective and has a low morbidity, whereas the occipitocervical junction can generally be treated by posterior resection and stabilization. The outcome should be determined by the survival time in an ambulatory, independent status, where pain is controlled, and the patient is not hospitalized. Surgical management shows the greatest improvement in pain reduction, but also in other domains of quality of life. Since prospective randomized studies comparing different treatment modalities for spinal metastases including surgery are not available and are ethically difficult to achieve, each case remains an interdisciplinary, shared decision making process for what is considered best for a patient or elderly patient. However, whenever surgery is an option, it should be planned before irradiation since surgery after irradiation has a significant higher complication rate.

Aged↗