Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Spectral estimation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86Linked to original sources

Solvent effects on the conformation and far UV CD spectra of gramicidin.

Solvent effects on the far-uv CD spectra of the polypeptide gramicidin have been studied systematically in a series of alcohols of increasing chain length, ranging from methanol to dodecanol. The effects observed are of two types: primary, involving a change in the equilibrium mixture of conformers present, and secondary, involving a shift in the spectral peak positions as a function of solvent polarizability. To quantitate the primary effect, the ratio of the individual conformers present was estimated by deconvolution of the spectra into their component species. For short chain length alcohols, both parallel and antiparallel double helices are found in considerable abundance. As the solvent chain length is increased and its polarity is decreased, the left-handed antiparallel double helical species is favored. For all alcohols with chain lengths of four or more carbon atoms, the ratio of the conformers present remains relatively constant. To quantitatively examine the secondary effect, the magnitudes of the spectral shifts on the dominant conformer (species 3) have been correlated with the dielectric constants and refractive indices of the solvents, thereby indicating what underlying physical properties are responsible for these shifts. This work thus demonstrates that for gramicidin, a flexible polypeptide, the solvent effects on the CD spectra can be resolved into two types: changes due to the mixture of conformers present and shifts in the spectral characteristics. Both effects need to be considered when interpreting CD spectra in terms of secondary structure for this and other polypeptides in nonaqueous solutions.

Alcohols↗

Analysis of auditory evoked potentials by magnitude-squared coherence.

Evoked potentials are usually analyzed in the time domain (voltage versus time). The most familiar frequency-domain measure, the power spectral density function, displays power as a function of frequency but doesn't distinguish signal power from noise power. The coherence function estimates, for each frequency, the ratio of signal power to total (signal plus noise) power and, thus, indicates the degree to which system output (scalp potential) is determined by input (acoustic stimulus). Coherence ranges from 0 to 1; values above specified critical values can be accepted as demonstrating statistically significant system response. In this paper, we present coherence analysis of human scalp responses to clicks and amplitude-modulated tones. In both cases, this analytic method provides insight into the spectral character of the response (for example, assisting in specifying desirable filter characteristics). Threshold sensitivity is also improved: statistically significant responses can be detected at lower intensity by coherence analysis than by inspection of time-domain waveforms.

Adult↗

On the precision of automated activation time estimation.

We examined how the assignment of local activation times in epicardial and endocardial electrograms is affected by sampling rate, ambient signal-to-noise ratio, and sinx/x waveform interpolation. Algorithms used for the estimation of fiducial point locations included dV/dtmax, and a matched filter detection algorithm. Test signals included epicardial and endocardial electrograms overlying both normal and infarcted regions of dog myocardium. Signal-to-noise levels were adjusted by combining known data sets with white noise "colored" to match the spectral characteristics of experimentally recorded noise. For typical signal-to-noise ratios and sampling rates, the template-matching algorithm provided the greatest precision in reproducibly estimating fiducial point location, and sinx/x interpolation allowed for an additional significant improvement. With few restrictions, combining these two techniques may allow for use of digitization rates below the Nyquist rate without significant loss of precision.

Algorithms↗

[Waveform caused by raised intracranial pressure--application of spectral analysis in the study of waveform].

Changes in spectrum of the intracranial pressure (ICP) pulse wave were studied while ICP was raised by the epidural balloon inflation. ICP and systemic blood pressure were estimated in the lateral ventricle and thoracic aorta, respectively. Transmission of pulsation from arterial pressure to ICP was estimated by the amplitude transfer function (TFa). Waveform of ICP pulse was also evaluated by distortion factor to represent how ICP pulse is different form a pure sine wave. The spectra of ICP and arterial pressure showed basically the same pattern; they consisted of fundamental wave (FW) and three harmonic waves (HW 2, HW 3, HW 4). Amplitude and values of TFa of each spectral component were increased as ICP was raised and revealed significant correlation. FW and HW 2 components showed break points when ICP was raised up to 35 mmHg, thereafter increments of amplitude and TFa became more remarkable in the range of higher ICP. TFa and amplitude of each spectral component of ICP pulse revealed significant correlation. These findings proved that changes of ICP pulse were the results of changed efficiency of pulse transmission from arterial pressure to CSF. It was already reported that the cerebrovascular tonus had decisive influences on the transmission of pulsation from arterial pressure to ICP because lowered vascular tonus would diminish the damping effect by arterial wall and facilitate the transmission of arterial pressure pulse to ICP. The break point of amplitude and TFa were considered to indicate that tonus of cerebral artery was remarkably lowered and the autoregulation of cerebral blood flow was exhausted.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Study of low-frequency ultrasonic cavitation fields based on spectral analysis technique.

A kind of new spectral analysis method for analyzing ultrasonic cavitation fields is brought forward in this paper. This method extracts the line spectrum and the continuous spectrum from the cavitation noise spectrum respectively, then obtains estimations of the energy intensities of different cavitation components such as the stable cavitation and the transient cavitation through corresponding calculations. The method is also applied to investigate low-frequency ultrasonic cavitation fields and is compared with spectral level analysis method. The results show that this method can provide adequate information on the course of the cavitation process, give the delicate analysis on the transient cavitation and the stable cavitation, and help to gain an insight into the nonlinear process of cavitation fields. Moreover, it also shows that the criterion for characterization of cavitation intensity presented by Frohly through studying the high-frequency ultrasonic fields can be used to evaluate the low-frequency ultrasonic fields.

Journal Article↗

Analysis of heart rate dynamics as a measure of autonomic tone in obstetrical patients undergoing epidural or spinal anesthesia.

BACKGROUND AND OBJECTIVES: The purpose of this study is to determine if spectral analysis of beat-to-beat heart rate variability will provide important data on autonomic nervous system function during either spinal or epidural anesthesia that is not apparent from the monitoring of mean heart rate and blood pressure. METHODS: Twelve ASA I patients presenting for elective cesarean delivery (7 epidural and 5 spinal anesthetics) were prospectively selected for study. Control and postblock 10-minute segments of instantaneous heart rates were analyzed for each patient. The total spectral power (Ps, 0.02-0.5 Hz), low frequency spectral power (PLF, 0.02-0.12 Hz), and high frequency spectral power (PHF, 0.12-0.5 Hz) were calculated for each data segment. The complexity of the heart rate time series was estimated by calculating the approximate entropy. RESULTS: Neither spinal or epidural anesthesia had any effect on heart rate or blood pressure. Both spinal and epidural anesthesia did produce a significant decrease in PS, PLF, and PHF. Although there were significant decreases in both the PLF and PHF, there was no change in the PLF/PHF ratio. There was a significant reduction in approximate entropy with spinal and epidural anesthesia, indicating a decrease in complexity of the heart rate dynamics. CONCLUSIONS: These data suggest that autonomic tone decreased with spinal and epidural anesthesia but the sympathetic-parasympathetic balance (expressed as PLF/PHF) did not change. Spectral measures, as well as approximate entropy, provide an independent evaluation of the integrity of the autonomic nervous system and cardiovascular control mechanisms that cannot be discerned from mean heart rate and blood pressure.

Adult↗

[Possible damage to the eye caused by light from ophthalmologic equipment].

Motivated by numerous findings of the damaging effect of intense light levels on the fundus we measured the spectral radiation of several ophthalmic illuminations and used it to calculate from it the spectral retinal irradiance. To evaluate the thermal hazard, we calculated the resulting temperature rise at the fundus. A measure for biological damage is the percentage of denaturated molecules, which is related to the temperature rise and its duration (essentially identical to the duration of illumination) by the so-called Arrhenius-integral. We used this measure to compare any illumination with experimentally evaluated threshold values for thermal damage. To evaluate the photochemical hazard we compared the spectral retinal irradiance with threshold values for photochemical induced lesions. Furthermore the illuminations were correlated with safety-guidelines likewise distinguishing between thermal and photochemical hazard. Under adverse conditions operation microscopes can present a thermal hazard to the patient's eye. Other ophthalmic illuminations are of less concern in this respect. A similar estimation applies to hazard from photochemical effects. The photochemical hazard can be diminished essentially by reducing the short-wavelength bluelight. Qualitatively, maximal permissible exposures according to safety guidelines are consistent with our thermal calculations as well as with photochemical hazard evaluation by comparing spectral retinal light levels with threshold irradiance for photochemical induced lesions. However, since quantitatively safety guidelines estimate the thermal hazard very conservatively, many common ophthalmic illuminations exceed the exposure limits, in some cases even drastically.

Hot Temperature↗

Effects of tissue anisotropy on the spectral characteristics of ultrasonic backscatter measured with a clinical imaging system.

In this paper, we report the effects of inherent tissue anisotropy on the spectral properties of backscattered ultrasound when measured with a commercially-available imaging system. We insonified five specimens of bovine tendon immersed in a water tank and rotated in 10 degrees increments while being imaged with a Hewlett-Packard Sonos 1500 system. The backscattered RF signals corresponding to each angle of insonification were digitized and the spectral characteristics of the backscattered ultrasound were determined. The mean anisotropy, defined as the average difference between values at perpendicular and parallel insonification, for band-limited estimates of backscattered power, centroid frequency, upper-band to lower-band power ratio, and upper-band to total-band power ratio were found to be 24.6 +/- 1.1 dB, 142 +/- 27 kHz, 32 +/- 13%, and 22 +/- 5%, respectively (mean +/- SE). The magnitude of each of these backscatter spectral parameters was larger at perpendicular insonification compared with the corresponding values at parallel insonification, consistent with previous measurements of the inherent anisotropy of ultrasonic attenuation and backscatter in tissue.

Animals↗

Noninvasive estimation of the pressure gradient across stenoses using sonographic contrast: in vitro validation.

OBJECTIVE: Because velocity measurements to estimate the degree of arterial stenosis are susceptible to local and systemic factors, we aimed to investigate the feasibility of estimating the pressure gradient across a stenosis noninvasively by using sonographic contrast. METHODS: Using a gravity-fed flow system, a 1:4000 dilution of a contrast agent in water was circulated through silicone tubes that had either focal or long-segment stenoses of varying severity in a water bath. We measured the cross-sectional areas of the normal and stenotic regions with B-mode sonography and the flow velocity with spectral Doppler sonography and calculated the pressure gradients across the stenoses using the empirically derived Young mathematical model and the simplified Bernoulli equation. Estimated gradients were compared with those measured manometerically. RESULTS: Both methods yielded estimates of pressure gradients that correlated with measured gradients (r > 0.988). In focal and long-segment stenoses, the Young model yielded gradients that agreed more closely with manometerically measured values than the Bernoulli equation (+/- 8% versus -24%-57%). Both methods were highly dependent on the ability to measure the luminal cross-sectional area. The presence of sonographic contrast in the vascular lumen highlighted the inner wall, allowing the accurate measurement of the luminal area to +/- 3.0%. CONCLUSIONS: The pressure gradient can be estimated across stenoses noninvasively. The Young model was more accurate than the simplified Bernoulli equation in this model using steady flow. Estimated gradients are highly dependent on the definition of the vascular lumen, a process aided by the use of sonographic contrast.

Carotid Stenosis↗

Effect of hemodialysis on cardiovascular rhythms in end-stage renal failure.

The purpose of this investigation was to determine non-invasively the alteration in autonomic cardiovascular control observed in end-stage renal disease (ESRD) patients submitted to a hemodialysis (HD) treatment. The effect of HD on finger blood pressure (BP) and heart rate (HR) variability was studied by means of spectral analysis in 12 ESRD patients at supine and during 45 degrees head-up tilt. Amplitude spectra of BP and HR rhythmicity were estimated and integrated amplitudes of the low (60 to 140 mHz, Mayer waves) and high frequency (area under the curve at mean respiration rate +/- 50 mHz) components were computed. The overall variability of a signal was given by the total area under the curve of the spectrum between 20 and 500 mHz. The transfer function was calculated between systolic BP and HR fluctuations using cross-spectral analysis. The principle findings are as follows: (1) Before HD, overall variability in systolic and diastolic BP as well as in the low frequency component in BP spectra were markedly reduced in ESRD patients compared to control subjects. Dialysis produced an immediate improvement in overall BP variability and the LF BP rhythmicity. (2) Before HD, there was an alteration of the HR spectral profile in uremic patients. (3) Chronic uremia and HD induced no changes in the transfer gain characteristic of modulation of HR by systolic BP. Taken together, these findings suggest that volume depletion in ESRD patients during a dialysis treatment is responsible for the improvement of overall BP variability and its spectral components.

Adult↗

Natural history of periocular capillary haemangiomas: changes in internal blood velocity and lesion volume.

AIM: Although the clinical characteristics of childhood periocular capillary haemangiomas are well known, serial measurements of blood velocity and lesion size are unknown. This investigation was designed to measure the changes in maximum blood velocity and estimated size of lesion in children with capillary haemangioma not requiring active intervention. STUDY DESIGN: Retrospective case-note review for a cohort of children with capillary haemangioma involving the eyelid and orbit. PATIENTS AND METHODS: Children with periocular capillary haemangioma, under the care of the Orbital unit at Moorfields Eye Hospital between 1996 and 2005, were monitored clinically and with repeated ultrasonographic examination. Volume estimates were calculated as an ovoid based on the three maximum orthogonal measurements for the haemangioma, and blood velocity was assessed by Colour Flow Mapping, Colour Doppler Energy Imaging, and Spectral Doppler techniques using a Sequoia 512 Acuson scanner. RESULTS: Twenty-four children (12 boys) had initial assessment by 18 months of age, and the haemangioma increased in size in 14/24 (58%), the increase being between 4 and 931% of initial volume estimate. The largest measured size for an individual haemangioma appears inversely related to the child's age at measurement, this mirroring a similar trend in measurements for the maximum blood velocity. Blood velocity measurements also tend to decrease with time, the peak velocity being before 1 year of age in the majority (15/24; 62%). In many children, both volume estimates and blood velocities show a cyclic variation-this occurring with increasing intervals between the maxima, before a final decay in both parameters. Although, for the whole group, there was no correlation (correlation coefficient=0.29) between estimated size and measured blood velocity, some individual children showed a significant correlation between the two parameters. The age at maximum blood velocity appeared to precede the age at maximum volume in most children, and in many there was an orbital anomaly detectable on ultrasonographic examination, even with complete clinical resolution of the haemangioma. CONCLUSIONS: Ultrasonographic examination of periocular capillary haemangiomas show that these lesions have a very high blood velocity in feeding vessels-about 2-3 orders of magnitude greater than normal capillary beds-and that the velocity and volume of such lesions undergo a cyclic variation during their natural history. Evidence suggests that both velocity and volume decrease with time, although often not returning to zero on ultrasonography (unlike the clinical resolution of the lesions). In most children, blood velocity peaks before volume estimates and this might suggest that decreasing perfusion leads to later tissue atrophy and involution of the haemangioma.

Blood Flow Velocity↗

Relationship between UVB and erythemally weighted radiation.

We discuss the move from reporting damaging UV radiation in terms of UVB to the now widely accepted erythemally weighted UV radiation (UV(Ery)) and the UV Index (UVI). The relationship between these quantities is given: to a good approximation, it is found that UVB(280-315 nm)= 7.55 [times] UV(Ery). In terms of the UV Index, the estimated UVB(280-315 nm) in units of W m(-2) is 18.9 times the UVI. These approximations generally hold to within approximately 10% for all solar zenith angles (sza) less than 70 degrees. For most practical purposes, this is a sufficient range, since for larger sza, the intensity of UVB is less than 10% of that for overhead sun conditions. The simple relationship above is verified using spectral measurements. However, tables are provided to enable calculation of the conversion with greater accuracy under such conditions. Similar model calculations are provided to estimate UVB(280-320 nm). Correction tables to convert erythemally weighted UV to other biological weightings are also presented.

Dose-Response Relationship, Radiation↗

Particle-hole asymmetry in doped mott insulators: implications for tunneling and photoemission spectroscopies.

We use exact sum rules for the one-particle spectral function to quantify the idea that it is more difficult to add an electron than to extract one in a system with strong local repulsion. Our results explain the striking asymmetry in the tunneling spectra of underdoped cuprates which increases with underdoping. We also propose a novel method, based on ratios of sum rules, to estimate local density variations in inhomogeneous materials. Using a variational approach, we show that the origin of the particle-hole asymmetry lies in the incoherent spectral weight.

Journal Article↗

Validation of the beat to beat measurement of blood velocity in the human ascending aorta by a new high temporal resolution Doppler ultrasound spectral analyser.

OBJECTIVE: To develop and validate a high temporal resolution spectral analysis system for Doppler measurements of blood velocity in the ascending aorta. DESIGN: An observational laboratory and clinical study comparing Doppler velocity-based measurements with fluid collection, electromagnetic flow catheters and probes, and thermodilution. SETTING: Tertiary referral cardiology unit and cardiac catheter laboratory. PATIENTS: Patients undergoing routine cardiac catheterisation for ischaemic heart disease, cardiac failure, and primary pulmonary hypertension. RESULTS: There was good agreement between Doppler-derived and electromagnetic cuff or catheter measurements of velocity in an experimental flow rig (SD of differences 4.75% for velocity integral) and in the patients (SD of differences 4% for velocity integral). There was also reasonably good agreement between simultaneous Doppler-derived and thermodilution-estimated cardiac output measurements in patients undergoing cardiac catheterisation (SD of differences 12.6%). CONCLUSIONS: This new method of high temporal resolution spectral analysis improves the resolution of rapidly changing blood velocities and may improve the ability to describe blood velocity patterns in the ascending aorta.

Adolescent↗

Measuring the threshold for speech reception by adaptive variation of the signal bandwidth. II. Hearing-impaired listeners.

In a previous study [Noordhoek et al., J. Acoust. Soc. Am. 105, 2895-2902 (1999)], an adaptive test was developed to determine the speech-reception bandwidth threshold (SRBT), i.e., the width of a speech band around 1 kHz required for a 50% intelligibility score. In this test, the band-filtered speech is presented in complementary bandstop-filtered noise. In the present study, the performance of 34 hearing-impaired listeners was measured on this SRBT test and on more common SRT (speech-reception threshold) tests, namely the SRT in quiet, the standard SRT in noise (standard speech spectrum), and the spectrally adapted SRT in noise (fitted to the individual's dynamic range). The aim was to investigate to what extent the performance on these tests could be explained simply from audibility, as estimated with the SII (speech intelligibility index) model, or require the assumption of suprathreshold deficits. For most listeners, an elevated SRT in quiet or an elevated standard SRT in noise could be explained on the basis of audibility. For the spectrally adapted SRT in noise, and especially for the SRBT, the data of most listeners could not be explained from audibility, suggesting that the effects of suprathreshold deficits may be present. Possibly, such a deficit is an increased downward spread of masking.

Adult↗

Diagnosis of malignancy in thyroid nodules by factor analysis of spectral and dynamic structures: a simultaneous dual-isotope dynamic study with thallium-201 and iodine-131.

The aim of this study was to identify malignant thyroid nodules using iodine-123 and thallium-201 simultaneous dynamic acquisition. The image sequences acquired were processed by factor analysis of spectral and dynamic structures (FASDS). Some 49 patients were investigated, and their diagnoses were confirmed by histological examination. Data processing enables the estimation of the spectra of the two isotopes and the evaluation of the kinetics and spatial structures related to each tracer. The superimposition of thallium and iodide sum images allowed us to delineate the nodule accurately. Two groups were defined: 21 patients who had 201Tl uptake in the nodule, and 28 who had none. In the first group, 5 nodules were carcinomas, whereas all nodules in the second group were benign. The results of the 201Tl dynamic study improved the diagnosis of carcinoma as the number of false-positive cases decreased. FASDS succeeds in extracting spectral and kinetic information, proving its usefulness in clinical diagnosis.

Adenoma↗

[Possibility of the spectral analysis of heterogeneous biological systems. The determination of the mycelium concentration of Actinomyces aureofaciens, a producer of tetracycline, cultured on a medium with corn meal].

A possibility of using spectroscopy of attenuated total reflection in the IR region for analysis of the heterogenic system consisting of the microorganisms and plant cells is discussed. The method of spectroscopy is proposed for estimating the mycelium concentration of Act. aureofaciens producing tetracycline in the presence of corn meal in the medium. The experimental data confirming this possibility are presented. The peculiar properties of the spectral analysis under these particular conditions are discussed. It is supposed that the method may be used for analysis of heterogenous systems including other microorganisms.

Culture Media↗

NMR Relaxation Mechanisms for Backbone Carbonyl Carbons in a 13 C, 15 N-Labeled Protein

The predominant relaxation mechanisms for backbone carbonyl carbon (13 C') relaxation in a 13 C, 15 N-doubly enriched sample of the thermostable Sso7d protein have been investigated. Pulse sequences for measurements of longitudinal and transverse 13 C' relaxation rates were implemented, and these rates were measured at magnetic fields of 11.7 and 14.1 T. The field dependence in measured rates is small and consistent with a predominant contribution from chemical-shift anisotropy (CSA) to 13 C' relaxation. A pulse sequence for measurement of {1 H}-13 C' cross-relaxation rates (steady-state NOEs) was also developed. This experiment reveals a significant NOE between protons and all 13 C', indicating that dipolar interactions between these nuclei contribute to 13 C' relaxation. Experiments designed to suppress cross correlation between CSA relaxation and dipole-dipole (DD) relaxation due to neighboring 13 Calpha indicate that this effect is negligible. A more quantitative treatment is also presented, in which backbone dynamics parameters are fitted to average 13 C' relaxation rates using Lipari-Szabo expressions for the spectral density. This fit, which reproduces well expected backbone dynamics parameters for a folded protein, is used to estimate the relative contributions of various mechanisms to 13 C' relaxation. It is found that both longitudinal and transverse relaxation rates are dominated by CSA relaxation and contain significant contributions due to DD relaxation induced by nearby protons. Contributions from DD relaxation due to covalently bound 13 Calpha and 15 N are comparably small. The predominant effects of CSA and 1 H-13 C' DD interactions, for which physical and geometrical parameters are uncertain, complicate the use of 13 C' relaxation as a sequence-specific probe for protein backbone dynamics.

Journal Article↗