Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Masks”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86Linked to original sources

Bright-light mask treatment of delayed sleep phase syndrome.

We treated delayed sleep phase syndrome (DSPS) with an illuminated mask that provides light through closed eyelids during sleep. Volunteers received either bright white light (2,700 lux, n = 28) or dim red light placebo (0.1 lux, n = 26) for 26 days at home. Mask lights were turned on (< 0.01 lux) 4 h before arising, ramped up for 1 h, and remained on at full brightness until arising. Volunteers also attempted to systematically advance sleep time, avoid naps, and avoid evening bright light. The light mask was well tolerated and produced little sleep disturbance. The acrophase of urinary 6-sulphatoxymelatonin (6-SMT) excretion advanced significantly from baseline in the bright group (p < 0.0006) and not in the dim group, but final phases were not significantly earlier in the bright group (ANCOVA ns). Bright treatment did produce significantly earlier phases, however, among volunteers whose baseline 6-SMT acrophase was later than the median of 0602 h (bright shift: 0732-0554 h, p < 0.0009; dim shift: 0746-0717 h, ns; ANCOVA p = 0.03). In this subgroup, sleep onset advanced significantly only with bright but not dim treatment (sleep onset shift: bright 0306-0145 h, p < 0.0002; dim 0229-0211 h, ns; ANCOVA p < .05). Despite equal expectations at baseline, participants rated bright treatment as more effective than dim treatment (p < 0.04). We conclude that bright-light mask treatment advances circadian phase and provides clinical benefit in DSPS individuals whose initial circadian delay is relatively severe.

Adolescent↗

Masking of the circadian rhythms of heart rate and core temperature by the rest-activity cycle in man.

Heart rate and core temperature are elevated by physical activity and reduced during rest and/or sleep. These masking effects may confound interpretation of rhythm waveforms, particularly in situations where the rest-activity rhythm has a different period from that of the core temperature rhythm. Such desynchronization often occurs temporarily as an individual adjusts to a new work shift or to a new time zone following rapid transmeridian travel, making it difficult to assess the impact of such schedule changes on the circadian system. The present experiments were designed to estimate the magnitude of these masking effects, by monitoring the heart rate, rectal temperature, and nondominant wrist activity (2-min samples) of 12 male subjects during 6 days of normal routine outside the lab and during 6 days of strict bedrest. Subjects also kept sleep, dietary, and exercise logs throughout the study. Average (20-min) waveforms were computed for each subject and each rhythm, at home and in bedrest. In addition, data were partitioned according to self-reported sleep and wake times and were analyzed separately for each state. Average waveform comparisons indicated that about 45% of the range of the circadian heart rate rhythm during normal routine was attributable to the masking effects of activity during wake, which also produced a 16% elevation in mean heart rate during wake and an 11% increase in mean heart rate overall. (Analysis of variance indicated that mean heart rate during sleep at home was not significantly different from the mean during sleep in bedrest.) On average, about 14% of the range of the circadian temperature rhythm during normal routine was attributable to the effects of activity masking. However, the change in range of the temperature rhythm, from home to bedrest, was very variable between subjects (-41% to +13%). This variability was not accounted for by age or by reported frequency of exercise at home. Normal activity during wake increased the mean temperature during wake by an average of 0.16 degrees C and the overall mean by about 0.12 degrees C. (Analysis of variance indicated that mean temperature during sleep at home was not significantly different from the mean during sleep in bedrest.) A 10-hr "night" (lights-off from 2200 to 0800 hr) was provided during bedrest, within which subjects could select their own sleep times. Times of sleep onset and wake onset were not significantly different between home and bedrest.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Compound myopic astigmatism correction using a mask in-the-rail excimer laser delivery system. Preliminary results.

PURPOSE: The latest development in the erodible mask technology is an excimer laser containing the mask in the laser optical pathway. This paper reports the results of the first human series of consecutive treatments performed for the correction of compound myopic astigmatism. METHODS: We have treated 83 eyes. Spherical equivalent attempted correction ranged between -1.75 and -11.75 D (mean -7.07+/- 2.45 D), astigmatic attempted correction ranged between -1.00 and -5.00 D (mean -2.42+/- 1.02 D). The sphere correction was made by diaphragm using a multi-zone software with three ablation zones: 100% of the total attempted correction for the central 5.0 mm zone, 70% for the second 6.0 mm zone, 30% for the outer 6.5 mm zone. Cylinder correction was made sequentially after myopic correction using the appropriate mask. RESULTS: One month after treatment, mean refractive error was + 1.07 +/- 1.24 D (range + 4.50/-1.75 D) for spherical equivalent, and -0.49 +/- 0.57 D (range + 0.75/-2.00 D) for astigmatism. Forty-eight eyes (57.8%) had uncorrected visual acuity of 20/40 or better. At six months, mean refractive error was +0.42 +/- 0.97 D (range + 3.75/-1.00 D) for spherical equivalent, and -0.44 +/- 0.51 D (range +0.25/-3.00 D) for astigmatism. Vector analysis showed that 57 eyes (68.7%) had 5 or less degrees rotation. Seventy-two (86.7%) and 54 eyes (65.1%) had uncorrected visual acuity equal or better than 20/40 and 20/25 respectively. One eye (1.2%) showed a best corrected visual acuity loss of more than one line, but 8 eyes (9.6%) had a gain of more than one line. One-year results on a smaller series (33 eyes) overlap with the six-month results. CONCLUSIONS: The mask in-the-rail excimer laser delivery system appears to be effective and predictable in the correction of compound myopic astigmatism. We observed no significant regression of the astigmatic correction over time. Longer follow-up on larger series is necessary to draw final conclusions.

Adolescent↗

Wildtype epidermal growth factor receptor (Egfr) is not required for daily locomotor or masking behavior in mice.

BACKGROUND: Recent studies have implicated the epidermal growth factor receptor (EGFR) within the subparaventricular zone as being a major mediator of locomotor and masking behaviors in mice. The results were based on small cohorts of mice homozygous for the hypomorphic Egfrwa2 allele on a mixed, genetically uncontrolled background, and on intraventricular infusion of exogenous EGFR ligands. Subsequenlty, a larger study using the same genetically mixed background failed to replicate the original findings. Since both previous approaches were susceptible to experimental artifacts related to an uncontrolled genetic background, we analyzed the locomotor behaviors in Egfrwa2 mutant mice on genetically defined, congenic backgrounds. METHODS: Mice carrying the Egfrwa2 hypomorphic allele were bred to congenicity by backcrossing greater than ten generations onto C57BL/6J and 129S1/SvImJ genetic backgrounds. Homozygous Egfrwa2 mutant and wildtype littermates were evaluated for defects in locomotor and masking behaviors. RESULTS: Mice homozygous for Egfrwa2 showed normal daily locomotor activity and masking indistinguishable from wildtype littermates at two light intensities (200-300 lux and 400-500 lux). CONCLUSION: Our results demonstrate that reduced EGFR activity alone is insufficient to perturb locomotor and masking behaviors in mice. Our results also suggest that other uncontrolled genetic or environmental parameters confounded previous experiments linking EGFR activity to daily locomotor activity and provide a cautionary tale for genetically uncontrolled studies.

Journal Article↗

Auditory masking patterns in the goldfish (Carassius auratus): psychophysical tuning curves.

The masking effects of tones on the detection auditory signals were studied in goldfish using the psychophysical tuning-curve paradigm. For signals below 350 Hz, masking is an inverse function of the frequency separation between masker and signal; a finding consistent with previous masking studies on fishes, birds and mammals. For signals above 350 Hz, masking peaks occur both in the 350 Hz region and at the frequency of the signal. Quantitative comparisons with recent neural tuning curves for goldfish saccular neurones suggest that the filtering observed may be determined by mechanical frequency selectivity below 350 Hz, but by a neural analysis of temporal patterns above this range.

Animals↗

Relevance of mask-roughness-induced printed line-edge roughness in recent and future extreme-ultraviolet lithography tests.

The control of line-edge roughness (LER) of features printed in photoresist poses significant challenges to next-generation lithography techniques such as extreme-ultraviolet (EUV) lithography. Achieving adequately low LER levels requires accurate resist characterization as well as the ability to separate resist effects from other potential contributors to LER. One potentially significant contributor to LER arises from roughness on the mask coupling to speckle in the aerial image and consequently to LER in the printed image. Here I numerically study mask surface roughness and phase roughness to resist LER coupling both as a function of illumination coherence and defocus. Moreover, the potential consequences of this mask effect for recent EUV lithography experiments is studied through direct comparison with experimental through-focus printing data collected at a variety of coherence settings. Finally, the effect that mask roughness will play in upcoming 0.3-numerical-aperture resist testing is considered.

Journal Article↗

Color and luminance spatial tuning estimated by noise masking in the absence of off-frequency looking.

We assessed the contribution of off-frequency looking for pattern detection and obtained bandwidths for chromatic and luminance mechanisms in conditions free from this effect. We used a simultaneous spatial masking technique with Gaussian enveloped sinusoidal test stimuli (0.5 cycle/deg) and filtered one-dimensional static-noise masks whose spectral power was uniformly distributed per octave. Stimuli were modulated in the chromatic (isoluminant red-green) or the luminance (yellow-black) domain. Color and luminance detection thresholds were compared for low-pass, high-pass, and notch- (band-stopped) filtered noise. We obtained the following results: (1) at high-noise spectral densities, masking by notched noise is greater than the summed masking of the high- and low-pass noise, indicating the presence of off-frequency looking for both color and luminance detection. There is no evidence for off-frequency looking at lower power densities. (2) Using notch-filtered noise, which avoids the problem of off-frequency looking, we found that color processing is subserved by bandpass channels with bandwidths similar to those revealed for luminance processing. (3) Both color and luminance mechanisms appear to have bandwidths proportional to their center frequency (constant in octaves). (4) The lower and upper sides of the color and luminance tuning functions were estimated individually by use of high-pass and low-pass noise of a low power density and are revealed to be asymmetric, with the lower side declining more steeply than the upper side.

Color Perception↗

Quantitative assessment of image quality enhancement due to unsharp-mask processing in x-ray fluoroscopy.

Spatial unsharp-mask processing and its variants are commonly used in x-ray radiography to enhance image contrast. We investigated the effect of three unsharp-masking filter kernels of different sizes on the detection of an advanced guidewire tip in simulated x-ray fluoroscopy image sequences. To isolate the effect of visual temporal processing, we repeated the experiments on single images. Filter gains were selected so that all three kernels increased the contrast of a 0.018-in. (0.457-mm) guidewire by a factor of 2 but had different effects on image noise and signal profiles. There was no statistically significant effect of unsharp masking on human-observer performance in single images. However, all three kernels significantly improved average performance in image sequences, and the guidewire contrast required for detection was reduced by 32%-40%. A prewhitening channelized observer model predicted the disparity between sequences and single images and fitted measurements at different kernel sizes well. A nonprewhitening observer model did not. We conclude that unsharp masking is a simple and effective method of improving guidewire visualization in fluoroscopically guided interventional procedures and that quantitative image quality studies are essential for evaluation of image-processing techniques in sequences such as x-ray fluoroscopy.

Adult↗

Nonlinear features and response mechanisms of a PtO2 mask layer for optical data storage with a superresolution near-field structure.

Optical features of a PtO2 mask layer in a superresolution near-field structure are investigated in detail by use of the Z-scan technique. The high photothermal stability of the PtO2 mask is revealed, and a phenomenon in which laser-irradiated PtO2 decomposes to yield Pt particles is confirmed. We also find a physical change in the mask layer that accompanies the chemical decomposition. Microscopic observations and atomic force microscope studies support the theory that the physical deformation is induced by the decomposition of PtO2. It is clear that the optical nonlinear responses of the PtO2 mask layer result from two mechanisms.

Journal Article↗

Analog micro-optics fabrication by use of a two-dimensional binary phase-grating mask.

The utilization of phase-mask technology for the fabrication of an analog micro-optics profile with a thick photoresist was investigated. A two-dimensional phase-grating mask with pi phase depth can produce a desired analog variation of exposure intensity, which allows one to vary the thickness of an analog photoresist after its exposure by a photolithographic stepper and development of the photoresist. A two-dimensional phase-grating mask of square pixels was simulated, designed, and fabricated. The fabrication of analog micro-optics in a thick SPR-220 photoresist by use of this phase mask was also demonstrated.

Journal Article↗

"Density mask". An objective method to quantitate emphysema using computed tomography.

We used a computed tomography (CT) scanner program ("density mask") that highlights voxels within a given density range to quantitate emphysema by defining areas of abnormally low attenuation. We compared different density masks, mean lung attenuation, visual assessment of emphysema and the pathologic grade of emphysema in 28 patients undergoing lung resection for tumor. In each patient, a single representative CT image was compared with corresponding pathologic specimens of tissue. There was good correlation between the extent of emphysema as assessed by the density mask and the pathologic grade of emphysema. The optimal attenuation level to define areas of emphysema may vary in different scanners, but, once determined for a particular scanner, the density mask accurately assesses the extent of emphysema and eliminates interobserver and intraobserver variability. It has the added advantage of determining the exact percentage of lung parenchyma showing changes consistent with emphysema.

Adult↗

Auditory backward masking in normal hearing children.

Backward masking (BM) is an auditory phenomenon in which the threshold of an auditory signal is elevated due to the presence of another signal (masker) that follows it. Models related to central auditory temporal processes, such as the 'temporal window' model, have been suggested to explain this phenomenon. If this assumption is correct then BM thresholds are expected to improve as a function of age. Electrophysiological data suggest that the central auditory system undergoes maturation in the first two decades of life. Empirical data on the development of BM with age are limited. Therefore, the goals of the present study were to study the effect of age on the performance of backward masking in normal developing children and to determine the age at which children reach adult-like performance. Subjects were 30 normal developing children divided into three groups according to age: 7, 9 and 11 years old. Stimuli consisted of a 1000 Hz pure tone and a bandpass masker (600-1400 Hz). Three BM threshold estimates were obtained for each subject using a three-alternative forced-choice adaptive procedure. The data show a trend for improvement in backward-masking thresholds with increasing age. Specifically, 7 and 9 year-old children performed significantly poorer than those reported for adults, whereas 11 year-old children reached adult-like performance. These data contribute to the small body of literature on backward masking in normal developing children. They are in keeping with what is known regarding the age of physiological maturation of the auditory system and have important clinical implications in the assessment of children with suspected temporal processing deficits.

Acoustic Stimulation↗

Fitness of a gas mask for the face of a worker handling organic solvents.

The fitness of the half facepiece of a gas mask to the face of a worker handling organic solvents was evaluated through the quantitative determination of the concentrations of both organic solvent vapors and airborne dust inside and outside the facepiece. Leakage rates for dust were measured using a mask-fitting tester on a facepiece with a dust filter-covered respirator cartridge of organic solvents. The same facepiece was evaluated for the leakage rate for organic solvent vapors through the determination of the concentrations of the air inside and outside the facepiece. Highly significant correlations were found between the leakage rates obtained for dust and those for organic solvent vapors. The leakage rates for organic solvents were found to be slightly higher than those for dust. The present finding suggested that the leakage of organic solvent vapors from the interstice between the facepiece of gas masks and workers' faces can be evaluated using the leakage rate for dust for the same facepiece of the gas mask attached with the cartridge covered with a high efficiency particulate air (HEPA) filter.

Dust↗

Comparison of linear, multilinear and mask microdensitometric analyses of Scheimpflug images of the lens nucleus.

We wanted to determine the agreement among three methods currently used to measure the average density of the nucleus from a Scheimpflug video image of the lens, namely, the multilinear, linear and mask techniques. Using the NEI Scheimpflug Cataract Imaging System, video images of the lens were obtained from 49 eyes of 31 consecutive patients with predominantly nuclear opacities of varying severities. For each image, 3 separate determinations of the average nuclear density [in optical density units (odu)] were obtained by one analyst sequentially applying each of the three methods. Repeat measurements were obtained by the same analyst one week apart to evaluate reproducibility (using 95% error range), of each of the methods. Pairwise comparisons of the 3 methods were also done. Only the error due to outlining of the nucleus was assessed. Reproducibility of each method was excellent. The 95% error ranges were +/- 0.015 odu for the linear, +/- 0.013 odu for the multilinear, and +/- 0.017 odu for the mask methods. Very strong linear relationships were observed between the linear and multilinear methods (R2 = 0.99), between the linear and mask methods (R2 = 0.97), and between the multilinear and mask methods (R2 = 0.98). Simple linear regressions calibrating these three methods against each other would facilitate comparison of density measurements using any of these methods for analysis of Scheimpflug images of the lens nucleus.

Cataract↗

Ultradian rhythms in arousal--the problem of masking.

Studies utilizing widely different experimental techniques provided evidence that there are spontaneous ultradian cycles in arousal during the waking state. These comprised of cyclic fluctuations between increased and decreased sleep propensity with a periodicity of about 1.5 hr. Being of relatively low amplitude, these cycles are vulnerable to masking effects by a variety of experimental conditions. Masking can be exerted by varying the tonic level of arousal, by coexisting slow ultradian components which are particularly prominent during the second half of the day, or by some specific experimental conditions. Furthermore, increased sleepiness was shown to enhance the slow ultradian components and suppress the 1.5-hr cycles in EEG indices of arousal on the one hand, and to emphasize the 1.5-hr cycles in motor activity and reaction time performance on the other hand. Much more attention should be paid to the problem of masking of ultradian cycles in arousal. Recognizing the sources and reasons for masking will advance our knowledge of the characteristics of these cycles and their function.

Arousal↗

[Young children's representational theory of mind in understanding masked facial expression].

In this study, development of young children's understandings of masked facial expression was examined from the perspective of the development of "theory of mind". In Experiment 1, short stories in which one character masks facial expressions to make another character have false beliefs were presented to 3-, 4-, and 6-year-old. They were asked questions to assess their judgements on various mental states (desire, belief, and intention) of story characters. And, to assess children's "representational theory of mind", they performed a "Smaties Task". The results showed that recognition of masked facial expression was developed from 3 to 4 years. Scores on "Smaties Task" was also improved during the same period. An additional analysis showed that the major determinant of to determine the understanding of masked facial expression was not the age but the possession of "representational theory of mind". In Experiment 2 more sophisticated but similar type of procedures were presented to 3- and 4-year-old children. Results replicated the results in Experiment 1 and the understanding of the intention of characters was also found to develop from 3 to 4 years.

Child↗

Guide to using masked design variables to estimate standard errors in public use files of the National Ambulatory Medical Care Survey and the National Hospital Ambulatory Medical Care Survey.

Until recently, sample design information needed to correctly estimate standard errors from the National Ambulatory Medical Care Survey (NAMCS) and the National Hospital Ambulatory Medical Care Survey (NHAMCS) public use files was not released for confidentiality reasons. In 2002, masked sample design variables were released for the first time with the 1995-2000 NAMCS and NHAMCS public use files. This paper shows how to use masked design variables to compute standard errors in three software applications. It also discusses when masking overstates or understates "in-house" standard errors, and how masking affects the significance levels of point estimates and logistic regression parameters.

Adolescent↗

Photorefractive keratectomy with an ablatable mask and rail system for simultaneous correction of myopia and astigmatism: preliminary results.

BACKGROUND: Alternative methods to correct myopic astigmatism with excimer laser surgery are being examined in an attempt to increase efficacy and reliability. One approach that is developing interest is the incorporation of a polymethylmethacrylate mask into the laser procedure. We examined the efficacy and safety of the Summit Apex Plus laser using a new ablatable mask and rail system. METHODS: Retrospective study based on follow-up of patients at 1 month (59 eyes), 3 months (37 eyes) and 6 months (24 eyes) at an eye laser centre in southern Ontario. Patients were recruited from 19 ophthalmic practices located primarily in the Niagara region and in western New York. Selected patients with naturally occurring myopia and astigmatism were treated with the Summit Apex Plus laser with the mask and rail system. Patients were evaluated for changes in refraction and visual acuity, and complications (including glare, haloes, haze and lines lost of best corrected visual acuity) were assessed. We calculated the surgically induced refractive change using the Holladay 10-step method. RESULTS: At 6 months the average residual sphere for the low myopia group (-7.00 dioptres or less) was -0.60 D and for the high myopia group (greater than -7.00 D) -0.61 D. This result was found to be both stable and accurate over the follow-up period. The cylinder component was reduced irrespective of the amount of preoperative myopia. Vector analysis showed that in most patients the correction of astigmatism was accurate, although slight undercorrection was observed. Complications were minimal, with few residual adverse effects at 6 months. INTERPRETATION: We found the mask and rail technique to be both effective and safe. Refractive change was stable and accurate, although astigmatism was slightly undercorrected. The procedure resulted in few complications, most of which resolved by 6 months.

Adult↗