Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DENTAL RESTORATION, TEMPORARY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,544 records · Page 86Linked to original sources

Influence of the interimplant distance on crestal bone resorption and bone density: a histomorphometric study in dogs.

BACKGROUND: The position of gingival soft tissues depends on the position and health of the underlying alveolar bone. The aim of this study was to evaluate the influence of different interimplant distances on crestal bone resorption after prosthetic restoration with a 5-mm distance between the contact point and the bone crest. METHODS: The mandibular bilateral premolars of six dogs were extracted and, after 12 weeks, each dog received eight implants, totaling 48 implants in the experiment. Two pairs, one in each hemiarch, were separated by 2 mm (group 1) and two by 3 mm (group 2). After 12 weeks, the implants received temporary acrylic prostheses. After 4 more weeks, metallic crowns substituted the temporary prostheses. After 4 more weeks, the animals were sacrificed, and their hemimandibles were removed, dissected, and processed. RESULTS: For groups 1 and 2, respectively, the mean of interimplant bone resorption (IIBR) analyzed histologically was 2.03 and 1.98 mm (P >or=0.05), and the mean of the distal extension bone resorption was 2.04 and 1.92 mm for groups 1 and 2, respectively (P >or=0.05). The crestal bone resorption between the implants was 0.13 mm (P >or=0.05) for both groups. The mean of IIBD for groups 1 and 2 was 79% and 80%, respectively. When the IIBD was compared to the distal extension bone density for group 1 (79% and 64%) and group 2 (80% and 62%), statistically significant differences were obtained for both groups (P <or=0.05). CONCLUSIONS: The distances of 2 and 3 mm between implants do not result in statistically significant differences in crestal bone resorption around implant surfaces in dogs. The bone density is enhanced when loading is present at the interimplant area.

Alveolar Bone Loss↗

Tissue healing under provisional restorations with ovate pontics: a pilot human histological study.

STATEMENT OF PROBLEM: Ovate pontics mimic the natural tooth contour and provide an esthetic result however, few studies have evaluated the histological changes in underlying tissues. PURPOSE: The purpose of this pilot study was to histologically evaluate the healing of gingival tissues in contact with provisional ovate pontics after 2 weeks. MATERIAL AND METHODS: Three patients requiring fixed partial dentures participated in this study. The provisional restorations consisted of a fixed partial denture having 2 ovate pontics: one in acrylic resin (Jet), with an ovate shell made of low-fusing ceramic (Duceram LFC); the other made completely of the same acrylic resin (control). After 2 weeks, biopsies of the gingival tissues beneath the pontics were retrieved for histological examination, and immunohistochemistry for evaluation of the vascular endothelial growth factor (VEGF) was performed. Data were analyzed using descriptive statistics. RESULTS: Clinically, all of the ovate pontic-prepared sites showed partial healing. Histologically, the thickness of the entire mucosa was similar in both specimens; however, in some regions, the epithelium presented ulcerations that were generally deeper and more frequent in control sites than in test sites. Immunohistochemical results showed that tissues beneath LFC pontics seemed to be less inflamed since they demonstrated a lower expression of VEGF (10.7 +/- .8) compared to those beneath acrylic resin ovate pontics (33.9 +/- 2.5). CONCLUSION: This pilot study demonstrated that the placement of provisional LFC ovate pontics may be advantageous for the reparative processes of the underlying tissues.

Acrylic Resins↗

Retention of provisional crowns fabricated from two materials with the use of four temporary cements.

STATEMENT OF PROBLEM: Practitioners often choose resin materials and temporary cements with little understanding about their effect on provisional crown retention. PURPOSE: This study evaluated the retention of provisional restorations made with 2 materials and cemented with 4 temporary cements. METHODS AND MATERIAL: Recently extracted molars were prepared with a flat occlusal surface, 4-mm axial length and 20-degree angle of convergence. Specimens were distributed into equivalent groups. Provisional crowns were constructed for each preparation with polymethyl methacrylate (Temporary Bridge Resin) or bis-acrylic composite (Protemp Garant) and later cemented with Temp-Bond, Temp-Bond NE, Temrex, and an experimental calcium hydroxide temporary cement. A second group with Temrex was evaluated using half the recommended liquid. A cementing force of 2.5 kg for 5 minutes was used. After initial bench set followed by 24 hours in room temperature water, the crowns were removed with an Instron mechanical testing machine at 0.5 mm/min. A 2-factor ANOVA was used with alpha=.05 (n = 10). Mode of debonding was analyzed with a nonparametric chi-square test of association. RESULTS: Mean dislodgment stresses ranged from 670 to 1072 kPa for polymethyl methacrylate crowns and 554 to 884 kPa for those made of composite. Differences were nearly significant for the type of provisional material (P =.061) and the cross-product interaction (P =.376) was not significant, whereas there were significant differences among the cements (P =.002) and the mode of debonding (P =.0034). CONCLUSIONS: Excluding Temp-Bond to eliminate a cross-product interaction demonstrated that the polymethyl methacrylate crowns were 19.3% more retentive than the composite crowns (P =.015). There was no statistically significant difference among the 4 temporary cements when the manufacturer's mixing instructions were followed (P =.186). However, the thicker consistency Temrex was more retentive than the recommended Temrex mix and Temp-Bond.

Analysis of Variance↗

Immediate occlusal loading of Osseotite implants in the completely edentulous mandible.

PURPOSE: This article reports the preliminary data from a clinical study of immediately loaded, full-arch, screw-retained prosthesis with distal extensions (hybrid prosthesis) supported by Osseotite implants placed in the edentulous mandible. MATERIALS AND METHODS: Fifteen patients who received 103 implants were enrolled in this study. The first 2 patients received both immediately loaded and submerged implants, while the remaining patients had all implants immediately loaded. The first 9 patients received a temporary prosthesis within 4 hours of surgery, and the hybrid prosthesis, made of a titanium framework and acrylic resin teeth, was placed after 6 months. The last 6 patients received the same type of hybrid prosthesis within 36 hours of surgery. Marginal bone loss was monitored via periapical radiographs by a computerized technique. RESULTS: One failure (out of the 92 immediately loaded implants) occurred after 3 weeks of function because of infection. A cumulative success rate of 98.9% was achieved for up to 48 months of follow-up, while the prosthetic cumulative success rate for the same period was 100%. Marginal bone loss at the immediately loaded implants was within the generally accepted conventional limits for standard delayed loading protocols. DISCUSSION: This technique can reduce treatment time but should be applied with caution. CONCLUSION: The preliminary results of this study suggest that rehabilitation of the edentulous mandible by an immediately loaded hybrid prosthesis supported by 5 to 6 implants may represent a viable alternative treatment to the classical delayed loading protocols.

Acrylic Resins↗

Long-term prognosis of crown-fractured permanent incisors. The effect of stage of root development and associated luxation injury.

OBJECTIVES: The aim of the present study was to investigate pulp healing responses following crown fracture with and without pulp exposure as well as with and without associated luxation injury and in relation to stage of root development. PATIENT MATERIAL AND METHODS: The long-term prognosis was examined for 455 permanent teeth with crown fractures, 352 (246 with associated luxation injury) without pulpal involvement and 103 (69 with associated luxation injury) with pulp exposures. Initial treatment for all patients was provided by on-call oral surgeons at the emergency service, University Hospital (Rigshospitalet), Copenhagen. In fractures without pulpal involvement, dentin was covered by a hard-setting calcium hydroxide cement (Dycal), marginal enamel acid-etched (phosphoric acid gel), then covered with a temporary crown and bridge material. In the case of pulp exposure, pulp capping or partial pulpotomy was performed. Thereafter treatment was identical to the first group. Patients were then referred to their own dentist for resin composite restoration. RESULTS: Patients were monitored for normal pulp healing or healing complications for up to 17 years after injury (x = 2.3 years, range 0.2-17.0 years, SD + 2.7). Pulp healing was registered and classified into pulp survival with no radiographic change (PS), pulp canal obliteration (PCO) and pulp necrosis (PN). Healing was related to the following clinical factors: stage of root development at the time of injury, associated damage to the periodontium at time of injury (luxation) and time interval from injury until initial treatment. Crown fractures with or without pulp exposure and no concomitant luxation injury showed PS in 99%, PCO in 1% and PN in 0%. Crown fractures with concomitant luxation showed PS in 70%, PCO in 5% and PN in 25%. An associated damage to the periodontal ligament significantly increased the likelihood of pulp necrosis from 0% to 28% (P < 0.001) in teeth with only enamel and dentin exposure and from 0% to 14% (P < 0.001) in teeth with pulp exposure. CONCLUSIONS: In the case of concomitant luxation injuries, the stage of root development played an important role in the risk of pulp necrosis after crown fracture. However, the primary factor related to pulp healing events after crown fracture appears to be compromised pulp circulation due to concomitant luxation injuries.

Adolescent↗

A comparison of 3 different endosseous nonsubmerged implants in edentulous mandibles: a clinical report.

The purpose of this prospective clinical study was to investigate the outcome of 3 different types of endosseous, nonsubmerged implants in the anterior part of the mandible. Fourteen older edentulous patients, 10 females and 4 males, were included. All participants received 3 different types of endosseous implants in the anterior mandible: 1 titanium plasma-sprayed cylindric implant (4 mm in diameter), 1 titanium cylindric implant with hydroxyapatite (HA) coating (4 mm in diameter), and 1 standard threaded titanium implant (3.75 mm in diameter). The 3 types of implants were originally designed to be placed in a 2-step surgical procedure. However, at this stage all implants were simultaneously provided with a temporary abutment that penetrated the mucosa. Three months later the temporary abutments were replaced by ball abutments, which were connected to an overdenture. At 12, 24, and 36 months after surgery, marginal bone resorption and Periotest values were recorded. Two patients died within the 2 first postoperative years. Five of 42 implants (11.9%) failed to osseointegrate. After 3 years, marginal bone resorption around titanium plasma-sprayed implants was significantly greater than that seen around both HA-coated and threaded titanium implants. Threaded titanium implants also had significantly better scores for marginal bone resorption than the HA-coated implants. Periotest values for HA-coated cylinders were significantly lower than test values for the other implants after 3 years (P < .05). The conclusion from this investigation is that nonsubmerged implants showed impaired prognoses compared to implants placed according to the 2-stage concept. Marginal bone resorption around titanium plasma-sprayed cylindric implants was clearly increased compared to the 2 other implant systems. Periotest values for HA-coated cylindric implants were superior to titanium plasma-sprayed and pure titanium implant surfaces.

Aged↗

Two-year clinical evaluation of nonvital tooth whitening and resin composite restorations.

BACKGROUND: Adhesive systems, resin composites, and light curing systems underwent continuous improvement in the past decade. The number of patients asking for ultraconservative treatments is increasing; clinicians are starting to reevaluate the dogma of traditional restorative dentistry and look for alternative methods to build up severely destroyed teeth. PURPOSE: The purpose of this study was to evaluate the efficacy of nonvital tooth whitening and the clinical performance of direct composite restorations used to reconstruct extensive restorations on endodontically bleached teeth. MATERIALS AND METHODS: Twenty-one patients 18 years or older were included in this clinical trial, and 26 endodontically treated and bleached maxillary and mandibular teeth were restored using a microhybrid resin composite. Patients with severe internal (tetracycline stains) and external discoloration (fluorosis), smokers, and pregnant and nursing women were excluded from the study. Only patients with A3 or darker shades were included. Teeth having endodontic access opening only to be restored were excluded; conversely, teeth having a combination of endodontic access and Class III/IV cavities were included in the study. A Vita shade guide (Vita Zahnfabrik, Bad Säckingen, Germany) arranged by value order was used to record the shade for each patient. Temporary or existing restorations were removed, along with a 1 mm gutta-percha below the cementoenamel junction (CEJ), and a resin-modified glass ionomer barrier was placed at the CEJ. Bleaching treatment was performed using a combination of in-office (OpalescenceXtra, Ultradent Products, South Jordan, UT, USA) and at-home (Opalescence 10% PF, Ultradent Products) applications. Two weeks after completion of the bleaching, the teeth were restored using a combination of PQ1 adhesive system and Vit-l-escence microhybrid resin composite (Ultradent Products). Wedge-shaped increments were placed and cured using the VIP Light (Bisco, Inc Schaumburg, IL, USA) through a combination of pulse and progressive curing techniques. RESULTS: All but one restoration were evaluated by two independent evaluators every 6 months during a 2-year period using modified US Public Health Service criteria. No restoration failed and "alpha" scores were recorded for all parameters but color stability, which was scored "bravo." Analysis of variance showed a significant shade change between baseline (mean=14.4+/-1.9) versus 2 weeks (mean=1.6+/-0.7) and 2 years (mean=2.8+/-1.7) (p<.0001). Although a significant shade change was observed between 2 weeks and the 2-year follow-up (p=.008), no significant difference was reported between the baseline and 2 weeks (12.9+/-2) versus baseline and 2 years (11.9+/-2.3). CONCLUSIONS: Significant tooth lightening was reported after the completion of whitening therapy on devitalized teeth; shade rebound was reported in less than 50% of the treated teeth and was limited to a maximum of four shades. A microhybrid resin composite demonstrated excellent clinical performance in the restoration of all endodontically treated and bleached teeth after a 2-year evaluation period. CLINICAL SIGNIFICANCE: Nonvital tooth whitening is responsible for a significant change in color of endodontically stained teeth. Successful nonvital tooth-whitening therapy allows for conservative tooth preparation, preserving and reinforcing sound tooth structure. The proper use of modern adhesive systems along with resin composite restorations precludes the use of more extensive restorative treatment, delaying expensive crown and bridge procedures.

Carbamide Peroxide↗

A biomechanical analysis of the orbitozygomatic complex in human cadavers: examination of load sharing and failure patterns following fixation with titanium and bioresorbable plating systems.

The orbitozygomatic complex (OZC) and zygomatic arch act as key buttresses in the restoration of midfacial projection and width in the treatment of panfacial fractures, yet little is known about the biomechanical and deformational forces placed on this region under applied load conditions. The aims of this project were (1) to study the stress-force relationships and load sharing of the intact human OZC under subfailure loads, (2) to assess load sharing and breaking strength of the OZC when intact and after four-point miniplate fixation with either titanium (1.2 and 1.7 mm) or bioresorbable (1.5 and 2.0 mm) systems, and (3) to analyze failure patterns. Using the MTS machine, fresh frozen human skulls stripped of soft tissue underwent loading with subfailure and failure forces directed in a standard fashion. Electrical resistance gauges applied directly to local and remote bony buttresses demonstrated temporary deformation at local (zygomatic arch, lateral and inferior orbital rim) and remote (supraorbital rim) buttresses under subfailure loading conditions. Breaking strength of the OZC (N = 10) measured before and after four-point application of 1.2- or 1.7-mm titanium or 1.5- or 2.0-mm bioresorbable miniplates demonstrated a significant (p < 0.05) decrease compared with intact controls. Surprisingly, the 2.0-mm bioresorbable miniplate construct provided only 13% of the intact breaking strength of the OZC compared with 39% for the 1.7-mm titanium system (p < 0.05). Plate bending or breakage was responsible for failure of the OZC following rigid fixation. Biomechanical testing of the OZC demonstrates (1) load sharing at regional and remote bony buttresses, (2) significant decreases in breaking strength following miniplate fixation, and (3) deformation of miniplates as a primary cause of failure under load conditions. Data generated from this project may be useful with regard to optimizing fixation of the OZC in the context and treatment of panfacial fractures.

Absorbable Implants↗

The effect of glass fiber reinforcement on the fracture resistance of a provisional fixed partial denture.

PURPOSE: This study determined the load required to fracture a three-unit provisional fixed partial denture restoration, which had been reinforced with an experimental glass fiber reinforcement. MATERIAL AND METHODS: Provisional fixed partial dentures (n = 5) were fabricated from a resin of polyethyl methacrylate powder and n-butylmethacrylate liquid. The fixed partial dentures in the control group were unreinforced. In the other groups, the fixed partial dentures were reinforced either with one, two, or three unidirectional glass fiber reinforcements and one glass fiber weave reinforcement. The load was applied to the fixed partial dentures by a steel ball placed in the cavity in the middle fossa of the pontic tooth. A longitudinal section of the fixed partial denture was made to determine the position of the reinforcements. Means were compared by analysis of variance. RESULTS: The load required to fracture the unreinforced fixed partial denture was 614 N, while incorporation of one unidirectional reinforcement increased the load to 660 N, two reinforcements to 818 N, three reinforcements to 827 N, and three reinforcements with one weave reinforcement to 973 N. It was found that the unidirectional reinforcements were positioned on the side of the occlusal surface of the fixed partial denture, namely, the side of compression during loading. CONCLUSION: The results suggest that, even though the glass fiber reinforcements were positioned on the least favorable side of the fixed partial denture in terms of the physical properties of the materials, these reinforcements considerably increased the fracture resistance of the provisional fixed partial denture.

Analysis of Variance↗

Five-year outcome of 111 immediate nonfunctional single restorations.

Immediate loading is a surgical-prosthetic procedure extensively used in implant dentistry. Despite its frequent use, minimal data are available on the long-term clinical success rate of immediate functional loading (IFL) and immediate nonfunctional loading (INFL) of implants. The aim of this study was to evaluate the long-term survival and bone loss of immediate nonfunctional single implant restorations in a group of patients that were monitored for 5 years. One hundred and eleven patients (41.4% men) with a median age of 40 years were included in this study. A total of 111 implants were placed. All implants were placed with a minimum insertion torque of 25 Ncm. A temporary restoration was relined with acrylic resin, trimmed, polished, and cemented or screw-retained 1 to 2 hours later. Occlusal contact was avoided in centric and lateral excursions. After provisional crown delivery, a periapical radiograph was performed by means of a customized Rinn holder device. Data were analyzed by means of Kaplan-Meier and life-table algorithms. Stratification of implant survival was performed for the available variables of interest, and comparisons were analyzed using a log-rank test. Investigated parameters were time of implant placement, bone quality, implant site, implant diameter and length, and type of implant surface enhancement. The parameters for overall success rate were defined by bone resorption <1.5 mm after the first year of loading and <0.2 mm thereafter. During the 5-year follow-up period, a survival rate of 95.5% was observed. All failures occurred within 4 months of implant loading. There were statistically significant differences regarding healed vs post-extraction implant sites (100% and 92.5%, respectively, P = .05) and type of bone (D1 vs D4 yielded 100% and 95.5%, respectively, P <.05). No differences were detected for: (1) site (100% for mandible and 94.63% for maxilla, P =-.319); (2) implant diameter (survival rates of 97.26% for <4.5-mm diameter and 92.11% for >4.5mm diameter, P = .206); (3) implant lengths (survival rates of 96.97% for implants >13 mm and 94.87% for implants <13 mm, P =.624); and (4) type of implant surface enhancement (survival rates of 94.03% for 67 cases of grit-blasted and acid-etched surfaces and a failure rate of 4 out of 5, and 94.12% for 17 cases of hydroxyapatite (HA)-coated surfaces with only 1 failure). The success rate (defined as bone resorption >1.5 mm after the first year of loading and >0.2 mm thereafter) was 97.2%. Immediate nonocclusal loading of single implants is a reliable surgical-prosthetic procedure with a low rate of implant loss and a low quantity of peri-implant bone loss over time.

Adolescent↗

Quality of removable partial dentures worn by the adult U.S. population.

STATEMENT OF PROBLEMS: Research-based assessments of the quality of removable partial dentures (RPDs), especially within a large patient population, are lacking. PURPOSE: This study evaluated the prevalence and quality of RPDs by use of the National Health and Nutrition Survey (NHANES III) data set. MATERIAL AND METHODS: Estimates of the health and nutritional status of the American population were obtained from the NHANES III data set (1988-1994). Calibrated dentists performed dental examinations on 17,884 adults. If the subject wore an RPD, its quality was assessed with 5 criteria: integrity, tooth wear, the presence of temporary reline material or adhesive, stability, and retention. In this study, the data on RPD defects were used to assess the prevalence of problems. The original population was divided into 4 subgroups: paired RPD data = subjects wearing both maxillary and mandibular RPDs (n = 600 prostheses, 300 maxillary and 300 mandibular); single RPD data = subjects with only one RPD (n = 1003 prostheses, 511 maxillary and 492 mandibular); maxillary versus mandibular RPD data = all subjects with all RPDs (n = 1603 prostheses, 811 maxillary and 792 mandibular); and pooled RPD data = all subjects with a single RPD plus subjects with 2 RPDs, counting only the RPD with the most defects (n = 1303 prostheses, 674 maxillary and 629 mandibular). The subjects were analyzed with descriptive statistics. The distribution of defects in the RPDs was examined for possible associations with chi(2) tests. The paired data for patients with both maxillary and mandibular RPDs were analyzed with Wilcoxon signed rank tests. The prevalence of RPDs as a function of patient age and the association between RPD defects and patient age were analyzed with chi(2) tests. The results were considered highly significant at P<.0001 and significant at P<.05. RESULTS: Of the 17,884 adults who underwent a dental examination, 1306 had RPDs. Three patients were excluded because their records were incomplete, leaving 1303 patients available for analysis. Most of the prostheses examined (65%) had at least 1 defect. Lack of stability was the most prevalent single defect. Distinctions in the type and prevalence of defects were observed between mandibular and maxillary RPDs. Mandibular RPDs had significantly more problems related to retention, whereas maxillary RPDs had significantly more problems related to the presence of reline material and to integrity defects. Tooth wear defects were significantly associated with patient age (P<.0001). Only one third of the RPDs were considered satisfactory according to NHANES III criteria. CONCLUSION: A review of the database used in this study indicated that, in spite of a decline in tooth loss, RPDs are still used in all age cohorts, including young adults. A large number of RPDs were found to have defects.

Adhesives↗

Influence of eugenol-containing temporary cement on efficacy of dentin-bonding systems.

Zinc oxide-eugenol (ZOE) cements are widely used as temporary filling materials. However, eugenol has earlier been shown to have a detrimental effect on both resin composites and dentin-bonding systems. The aim of the present in vitro study was to examine whether ZOE cement would also reduce the efficacy of relatively new dentin-bonding systems. This was done by determination of gap formation around resin composite fillings in dentin cavities and of bond strength of resin composite to enamel and dentin. The tooth surfaces involved were either freshly cut, or had been exposed to a ZOE cement (IRM) or to a non-ZOE cement (Cavit) for 7 d before application of a dentin-bonding system (Gluma CPS or Scotchbond Multi-Purpose Plus) and a resin composite (Z100). Gap formation was assessed in a light microscope on 20-min-old fillings and expressed as wall-to-wall contraction (the width of the maximum marginal gap in % of the cavity diameter). Bond strength was measured in shear on 1-d-old specimens. The mean values of wall-to-wall contraction were 0.06-0.09% with Scotchbond Multi-Purpose Plus and 0.20-0.24% with Gluma CPS. The mean values of bond strength to enamel were 22-25 MPa for Scotchbond Multi-Purpose Plus and 20-23 MPa for Gluma CPS, and to dentin were 20-22 MPa for Scotchbond Multi-Purpose Plus and 13-14 MPa for Gluma CPS. The use of Scotchbond Multi-Purpose Plus resulted in higher bond strength to dentin and less wall-to-wall contraction than did Gluma CPS. No differences were found in either wall-to-wall contraction or in bond strength between the three groups for either dentin-bonding system. Thus, the ZOE cement did not influence the efficacy of two relatively new dentin-bonding systems.

Analysis of Variance↗

Early functional loading at 5 days for Brånemark implants placed into edentulous mandibles: a prospective, open-ended, longitudinal study.

BACKGROUND: Traditionally, implants placed in the mandible heal for 3 to 4 months before they are loaded. In maxillae, healing time usually takes 5 to 6 months. The purpose of this study was to evaluate placement of 4 to 6 implants in edentulous mandibles. The implants were placed between mental foramina for support of non-metal, reinforced, fixed, implant-supported provisional prostheses. A unique method was used to convert existing dentures into fixed, implant-supported appliances. The implants were functionally loaded early (5 days). METHODS: Twenty patients with edentulous mandibles or with 2 to 3 remaining mandibular teeth were enrolled in this open-ended, prospective study. Existing dentures without porcelain teeth were modified for use as a surgical guide. These dentures were used as temporary fixed prostheses. Patients were to have metal-reinforced appliances fabricated by the referring dentists after 3 to 4 months of healing. After implant installation, prosthetic abutments were fixed to the implants and tightened to 20 Ncm without counter torque. Bone quality and quantity as well as implant size and position were entered into a computer database. Impression copings were attached to the abutments, and the modified denture was used for a pick-up impression. After the impression was made, implant replicas were fitted to the impression copings and casts were poured. Gold cylinders were processed into the tissue side of the denture. Laboratory screws were used to attach the denture with gold cylinders to abutment replicas. The dentures were processed, polished, and inserted 5 days after implant surgery. Radiographs were taken to verify proper fit of the gold cylinders to the prosthetic abutments (baseline). Radiographs were taken at each follow-up visit and were used to measure changes in crestal bone levels. RESULTS: Twenty patients received 92 machined-surface commercially pure titanium implants in fully edentulous mandibles. Of the total number of implants placed, two were lost between 0 to 1 year and one between 1 to 2 years. Twenty patients with a total of 90 implants were followed between 0 to 1 year. Fourteen patients have been followed between 1 to 2 years, 7 between 2 to 3 years, and 2 between 3 to 4 years. One patient died after 9 months of loading (4 implants loaded, 2 sleeper implants); another died between 1 to 2 years. A total of 6 implants remained buried (sleepers). At 2 years, the cumulative success rate is 96.3%. Survival of the implant bridges is 100.00%. The mean crestal bone level at 5 days for 11 patients was 2.1 mm (SD 0.526, SE mean 0.159) (measurements were not available for the deceased patient), while the mean level at an average of 15 months was 1.96 mm (SD 0.585, SE mean 0.176). Differences between the measurements taken at 5 days with those taken at an average of 15 months were not significant (P < 0.683). CONCLUSIONS: Results of this study indicate that 4 to 5 implants can be placed and loaded within 5 days of implant insertion with high success (96.3%). Success rates for the interim and final prosthesis are 100%. A simple, possibly cost-effective method of using non-metal reinforced dentures as interim fixed, provisional dentures has been described. Impressions and registrations for making the prosthesis can be made at the time of implant installation, and this method is accurate enough to make provisional restorations. The modified denture can function as an interim fixed, implant-supported prosthesis for up to 30 months. Results of x-ray measurements indicate stable crestal bone levels for up to an average of 15 months.

Aged↗

The effect of fiber reinforcement type and water storage on strength properties of a provisional fixed partial denture resin.

Fracture resistance of provisional restorations is an important clinical concern. This property is directly related to transverse strength. Strengthening of provisional fixed partial dentures may result from reinforcement with various fiber types. This study evaluated the effect of fiber type and water storage on the transverse strength of a commercially available provisional resin under two different conditions. The denture resin was reinforced with either glass or aramid fiber or no reinforcement was used. Uniform samples were made from a commercially available autopolymerizing provisional fixed partial denture resin. Sixteen bar-shaped specimens (60 x 10 x 4 mm) were reinforced with pre-treated epoxy resin-coated glass fibers, with aramid fibers, or with no fibers. Eight specimens of each group, with and without fibers, were tested after 24 h of fabrication (immediate group), and after 30-day water storage. A three-point loading test was used to measure the transverse strength, the maximal deflection, and the modulus of elasticity. The Kruskal-Wallis Analysis of Variance was used to examine differences among the three groups, and then the Mann-Whitney U Test and Wilcoxon Signed Ranks Test were applied to determine pair-wise differences. The transverse strength and the maximal deflection values in the immediate group and in the 30-day water storage group were not statistically significant. In the group tested immediately, the elasticity modulus was found to be significant (P = 0.042). In the 30-day water storage group, all the values were statistically insignificant. The highest transverse strength was displayed by the glass-reinforced resin (66.25MPa) in the immediate group. The transverse strength value was 62.04MPa for the unreinforced samples in the immediate group. All the specimens exhibited lower transverse strength with an increase in water immersion time. The transverse strength value was 61.13 MPa for the glass-reinforced resin and was 61.24 MPa for the unreinforced resin. The aramid-reinforced resin decreased from 62.29 to 58.77 MPa. The addition of fiber reinforcement enhanced the physical properties (the transverse strength, the maximal deflection, the modulus of elasticity) of the processed material over that seen with no addition of fiber. Water storage did not statistically affect the transverse strength of the provisional denture resin compared to that of the unreinforced resin. The transverse strength was lowered at water storage but it was not statistically significant. The transverse strength was enhanced by fiber addition compared to the unreinforced resin. The glass fiber was superior to the other fiber. Also the modulus of elasticity was enhanced by fiber addition compared to the unreinforced resin.

Acrylic Resins↗