Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Colonoscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86Linked to original sources

Colonoscopy with a VideoEndoscope: preliminary experience.

A prototype VideoEndoscope was tested that does not have an optical fiber bundle. This was replaced by a sensing device in the instrument's distal tip that transmits an image to a video processor for display on a television monitor. The television image was excellent, and the instrument system and its concept in general were thought to be acceptable for diagnostic and therapeutic colonoscopy. The instrument has unique advantages with regard to documentation, demonstration, and review of endoscopic findings.

Colonic Diseases↗

Does virtual colonoscopy have a major role in population-based screening?

In summary, technical advances in the performance of VC are occurring at a very rapid pace. These technical improvements will undoubtedly improve the polyp detection rate and reduce false-positive and false-negative examinations. The concept of VC is clearly attractive and the general public is enamored with everything that has an association with virtual reality. As other articles in this issue have revealed, there are many techniques in development to help stratify patients at risk for colon cancer. As we begin to focus our health care resources on those at highest risk, the less need there is for inexpensive, broadly based screening techniques. Clearly, those patients at high risk for having polyps are better served by colonoscopy because of its therapeutic potential. That being said, in the view of this author, if a virtual preparation can be achieved and the cost of VC can be kept relatively low, then this technique will become part of our mainstream clinical practice. If an immaculate colon preparation must be performed and if the costs reflect standard abdominal and pelvic CT rather than a special reduced cost for VC, then it is doubtful that there will be any significant impact from this technology

Colonic Polyps↗

Right colon loop: a potential pitfall for total colonoscopy.

A right colon loop can occur during total colonoscopy. A light on the anterior abdominal wall in the right lower quadrant and a fluoroscopic view may imply that the tip of the colonoscope is in the cecum. The right colon loop can be documented by roentgenograms and the injection of a radioopaque solution. An arrest in embryological development with overdistension with air accounts for the right colon loop. An unrecognized right colon loop could account for a failure to see a cecal carcinoma.

Colon↗

Therapeutic colonoscopy.

The authors report their experience with regard to operative fibrecolonoscopy both in routine and emergency cases. After taking into consideration the use of this technique for the study and treatment of rectal and colonic polyps, they also recommend the use in emergency conditions of colonic haemorrhage and in the removal of foreign bodies. They conlcude that therapeutic colonoscopy must be recognised as one of the most useful methods of diagnosis and treatment of some lesions of the rectum and colon.

Adenocarcinoma↗

[CT colonography --"virtual colonoscopy"--a current review].

This article reviews published data regarding CT colonography and discusses both technical and medical aspects of its development over the last 10 years. Although colonography can be performed using MRI instead of CT, mainly CT aspects are dealt with. The technical development of CT to the current generation of Multi-detector-row-CT is explained, and the influence of various factors (slice thickness, dose, patient preparation, post processing) is discussed. The method has a high sensitivity and specificity as well as a high negative predictive value for the detection of polyps > or = 1 cm, but is currently still insufficient in the detection of polyps < 5 mm. It is a valid alternative after incomplete optical colonoscopy and an alternative in patients with "high-risk" for conventional endoscopy. In the future it may become an alternative for conventional endoscopy in screening programs for colorectal cancer.

Clinical Trials as Topic↗

A clinicopathological study of minute polypoid lesions of the colon based on magnifying fiber-colonoscopy and dissecting microscopy.

Magnifying fiber-colonoscopy reveals that adenoma, minute carcinomatous lesion in an adenoma (which is termed focal carcinoma), and mucosal carcinoma of the colon, each has its own characteristic pit pattern. Inspection by dissecting microscope of resected specimens obtained from subjects whose colonic mucosa had been considered normal, often reveals an abnormal pit pattern of less than 1 mm, and subsequent histologic examination confirms the frequent presence of incipient adenoma. Clinical magnification inspection of areas of colonic mucosa considered normal on the basis of ordinary observation, reveals pit patterns identical to those seen in resected specimens.

Adenoma↗

Initial treatment of sigmoid volvulous by colonoscopy.

The initial management of acute, nonstrangulated sigmoid volvulous is to attempt proctosigmoidoscopic, rectal tube, or barium enema reduction and evacuation. If unsuccessful emergency surgery is necessary. The flexible colonoscope offers an additional therapeutic modality to effectuate preoperative reduction of the twisted sigmoid colon if attempts with conventional methods fail. Three cases of acute sigmoid volvulous are presented which illustrate for the first time successful reduction of acute sigmoid volvulous by colonoscopy after failure of the usual methods of treatment. Instead of emergency surgery all of these patients had elective resection with primary colocolostomy. Patients with acute sigmoid volvulous refractile to reduction by conventional modalities should have an attempt at flexible colonoscopic reduction.

Acute Disease↗

Colonoscopy in the diagnosis of unexplained rectal bleeding.

Three hundred six patients with unexplained rectal bleeding were examined by colonoscopy. Significant lesions were found in 30% including polyps having a diameter of 0.5 cm or larger in 14%, carcinoma in 8%, and a small number of patients with inflammatory bowel disease, vascular formations, and radiation colitis. Colonoscopic findings in a large subgroup of patients with diverticulosis established by barium enema did not differ significantly from those of the group as a whole. Significant lesions were also identified in 22% of small subsets of patients with occult bleeding or unexplained melena.

Adenoma↗

CT and MR colography (virtual colonoscopy): status report.

Computed tomography (CT) and magnetic resonance (MR) colography (virtual colonoscopy) are new techniques being developed for the purpose of imaging colorectal polyps and cancer. Limited data are available regarding the performance characteristics of either technique, particularly MR. Initial reports suggest that the sensitivity of CT and MR colography for patients with adenomas > or = 1 cm ranges from 75-90%, and decreases precipitously for smaller polyps. Very early data suggest that the specificity for patient with large adenomas is around 90%, but for patients with adenomas in the 5-9 mm range has been as low as 65%. This review discusses currently available published and abstracted data on CT and MR colography and discusses the real and potential advantages and disadvantages of CT and MR colography compared to current colonic imaging methods. The review discusses problems that must be overcome in order for CT or MR colography to be demonstrated as practical tests, and suggests guidelines for the performance of clinical trials testing the performance characteristics of these methods.

Adult↗

Adynamic ileus complicating colonoscopy.

A case of adynamic ileus of the colon and small bowel complicating colonoscopy is reported. The patient recovered with conservative management. Possible pathogenesis of this rare complication is discussed.

Colon↗

Computer-aided detection for virtual colonoscopy.

Colon cancer is one of the leading causes of cancer deaths in the developed countries. Most colon cancers can be prevented if precursor colon polyps are detected and removed. Virtual colonoscopy, or CT colonography, has shown promise to be the future screening tool for polyp detection, with a number of studies performed at academic institutions showing high sensitivity and specificity. Two main factors limiting CT colonography in general use are its excessive interpretation time and the variable sensitivity among readers. This article discusses the potential of computer-aided detection to address these problems. We also review the current state of research in this field and the future roles and challenges of CAD for CT colonography.

Algorithms↗

Automatic centerline extraction for virtual colonoscopy.

In this paper, we introduce a concise and concrete definition of an accurate colon centerline and provide an efficient automatic means to extract the centerline and its associated branches (caused by a forceful touching of colon and small bowel or a deep fold in twisted colon lumen). We further discuss its applications on fly-through path planning and endoscopic simulation, as well as its potential to solve the challenging touching and colon collapse problems in virtual colonoscopy. Experimental results demonstrated its centeredness, robustness, and efficiency.

Algorithms↗

Lines of curvature for polyp detection in virtual colonoscopy.

Computer-aided diagnosis (CAD) is a helpful addition to laborious visual inspection for preselection of suspected colonic polyps in virtual colonoscopy. Most of the previous work on automatic polyp detection makes use of indicators based on the scalar curvature of the colon wall and can result in many false-positive detections. Our work tries to reduce the number of false-positive detections in the preselection of polyp candidates. Polyp surface shape can be characterized and visualized using lines of curvature. In this paper, we describe techniques for generating and rendering lines of curvature on surfaces and we show that these lines can be used as part of a polyp detection approach. We have adapted existing approaches on explicit triangular surface meshes, and developed a new algorithm on implicit surfaces embedded in 3D volume data. The visualization of shaded colonic surfaces can be enhanced by rendering the derived lines of curvature on these surfaces. Features strongly correlated with true-positive detections were calculated on lines of curvature and used for the polyp candidate selection. We studied the performance of these features on 5 data sets that included 331 pre-detected candidates, of which 50 sites were true polyps. The winding angle had a significant discriminating power for true-positive detections, which was demonstrated by a Wilcoxon rank sum test with p < 0.001. The median winding angle and inter-quartile range (IQR) for true polyps were 7.817 and 6.770 - 9.288 compared to 2.954 and 1.995 - 3.749 for false-positive detections.

Algorithms↗

Total and subtotal colonoscopy with short instrument and without fluoroscopy.

The technique and results of 111 consecutive colonoscopies with a short colonoscope without the use of X-ray screening are reviewed. The caecum could be reached in 44 percent of the cases. No complications occurred. The great clinical value of the procedure is shown by the following findings:X-ray-negative lesions--including 2 cases of carcinoma--were found in 35 percent of the cases, radiologically demonstrated lesions could be defined more precisely in 18 percent, and the presence of colonic lesions could be ruled out in 11 percent in spite of equivocal X-ray findings. It is concluded that many more centres ought to take up the procedure, which offers the prospect of significantly reducing suffering and death from colonic disease.

Adult↗

Reduction of false positives by internal features for polyp detection in CT-based virtual colonoscopy.

In this paper, we present a computer-aided detection (CAD) method to extract and use internal features to reduce false positive (FP) rate generated by surface-based measures on the inner colon wall in computed tomographic (CT) colonography. Firstly, a new shape description global curvature, which can provide an overall shape description of the colon wall, is introduced to improve the detection of suspicious patches on the colon wall whose geometrical features are similar to that of the colonic polyps. By a ray-driven edge finder, the volume of each detected patch is extracted as a fitted ellipsoid model. Within the ellipsoid model, CT image density distribution is analyzed. Three types of (geometrical, morphological, and textural) internal features are extracted and applied to eliminate the FPs from the detected patches. The presented CAD method was tested by a total of 153 patient datasets in which 45 patients were found with 61 polyps of sizes 4-30 mm by optical colonoscopy. For a 100% detection sensitivity (on polyps), the presented CAD method had an average FPs of 2.68 per patient dataset and eliminated 93.1% of FPs generated by the surface-based measures. The presented CAD method was also evaluated by different polyp sizes. For polyp sizes of 10-30 mm, the method achieved mean number of FPs per dataset of 2.0 with 100% sensitivity. For polyp sizes of 4-10 mm, the method achieved 3.44 FP per dataset with 100% sensitivity.

Biophysical Phenomena↗

Operative colonoscopy.

In 12 patients with radiologically-proved lesions of the colon total retrograde fibreoptic colonoscopy was performed on the unopened bowel at laparotomy. Additional polyps were found in five patients, and in four of these the polyp was not readily palpable through the bowel wall. This procedure is indicated whenever there are reasonable grounds for suspecting the presence of multiple polypi.

Adult↗

Colonoscopy and bacteraemia.

A prospective study was performed on 35 patients undergoing colonoscopy. Aerobic and anaerobic blood cultures before, during and after the investigation failed to demonstrate bacteraemia in any instance.

Australia↗

Complications of fiberoptic Endoscopy. II. Colonoscopy.

Fiberoptic colonoscopy is being used increasingly for endoscopic visualization of the large intestine, particularly in the electrocautery removal of polypoid lesions. Complications may include bleeding, mesosigmoid hematoma, splenic avulsion, and impaction of the instrument, but the most common is perforation of the colon, which occurs in 0.4-1.9% of colonoscopic examinations. Radiological evaluation plays a critical role. Free intraperitoneal rupture may be clinically overlooked in an aged or infirm patient. Extraperitoneal perforation often results in delayed signs and symptoms. The demonstration of extraluminal gas documents perforation. Recent roentgen-anatomical studies of the characteristic distribution of extraperitoneal gas may permit precise localization of the site of colonic perforation on plain films.

Aged↗