Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Atrial Function, Right”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86Linked to original sources

Circus movement atrial flutter in the canine sterile pericarditis model. Activation patterns during initiation, termination, and sustained reentry in vivo.

The mechanisms of single-loop reentry in a syncytium without anatomically predetermined pathways have not been shown. Using a "jacket electrode" with 111 bipolar electrodes in a nylon matrix, we mapped in situ the atrial epicardial surface during atrial flutter in dogs with sterile pericarditis. Of 21 episodes of reentrant atrial flutter, only four showed double-loop ("figure-eight") reentry, whereas in 17 episodes a single loop was present. During initiation of single-loop reentry, an arc of functional block extended to the atrioventricular (AV) ring. This forced activation to proceed as a single wave around the free end of the arc, before breaking through the arc close to the AV ring. Activation continued as one loop around an arc close to the AV ring (in eight episodes) or around a combined functional and anatomic obstacle (in nine episodes) when the arc joined an atrial vessel. A zone of slow conduction was consistently bordered by the arc of block and the AV ring or by the anatomic obstacle and the AV ring. Spontaneous termination occurred when conduction failed in this area and the arc rejoined the AV ring. High-density recordings (2 mm) along the arc of block showed double potentials separated by an isoelectric interval, interpreted as local activation and electrotonus due to activation on the opposite side of the arc. Histologically, a diffuse inflammatory reaction involved 50-80% of the atrial wall. A transitional layer of myocardial bundles with preserved cross striation, but separated by edema and inflammatory cells, was enclosed between an epicardial layer of fragmented myocytes and an endocardial layer of grossly intact myocardium. There were no distinctive features at sites of functional conduction block or slowed conduction. In conclusion, single-loop reentry is the common pattern during atrial flutter in this model. Its induction depends on an interaction of the AV ring, a functional arc of block, and a zone of slow conduction. The location of the inferior vena cava predisposes the lower right atrium to this type of reentry.

Animals↗

Change in right ventricular function during off-pump coronary artery bypass graft surgery.

OBJECTIVES: Hemodynamic derangement during displacement of beating heart in off-pump coronary artery bypass graft (OPCAB) surgery might be related with right ventricular (RV) dysfunction. We evaluated RV function and hemodynamic alterations using a thermodilution pulmonary artery catheter. METHODS: The study included 30 patients undergoing OPCAB, using single pericardial suture and tissue stabilizer. A thermodilution pulmonary artery catheter for continuous monitoring of the cardiac output (CO), right ventricular ejection fraction (RVEF) and RV volume was inserted before anesthesia. The hemodynamic variables were measured after the induction of anesthesia, 5 min after the heart was positioned for each coronary anastomosis and after the sternum was closed. RESULTS: There was no significant change in the RVEF and cardiac index during anastomosis of the left anterior descending artery and right coronary artery. However, the significantly reduced RVEF accompanied by an increase in RV afterload and decrease in the CO was observed during anastomosis of the obtuse marginal (OM) artery. RV volumes did not significantly change during anastomoses, though the right atrial pressure increased during anastomoses of all coronary arteries. CONCLUSIONS: The displacement of beating heart for positioning during anastomosis of the graft to OM artery caused significant derangement of RV function and decrease in CO. A thermodilution catheter continuously measuring the CO and RVEF was useful to monitor the change in RV function and volume during OPCAB.

Aged↗

Effects of successful cardioversion of persistent atrial fibrillation on right ventricular refractoriness and repolarization.

AIM: Changes in ventricular refractoriness and repolarization after successful electrical cardioversion to sinus rhythm in persistent atrial fibrillation (AF) patients were studied. METHODS AND RESULTS: In 33 AF patients with controlled ventricular response, right ventricular ERP (VERP) at three basic cycle lengths (600, 500, 400 ms), as well as monophasic action potential duration (MAPd(90)) at a drive cycle length of 500 ms, were measured just before, 20 min and 24 h after cardioversion. VERP at 600 ms changed from 241+/-19 ms to 249+/-21 ms to 253+/-24 ms (P<0.001), VERP at 500 ms changed from 234+/-19 ms to 242+/-22 ms to 246+/-23 ms (P<0.001) and VERP at 400 ms changed from 224+/-20 ms to 232+/-23 ms to 236+/-24 ms (P<0.001). MAPd(90) changed from 247+/-16 ms preconversion to 252+/-17 ms 20 min postconversion to 253+/-19 ms after 24 h (P<0.05). Change in refractoriness at 500 ms was well correlated with change of mean RR interval before and 20 min after conversion (R=0.616, P<0.001). There was no correlation between RR variability and VERP before cardioversion. CONCLUSION: Restoration of sinus rhythm in persistent AF patients is followed by significant effects on ventricular refractoriness and repolarization related to cycle length change. No AF related ventricular electrophysiological alterations were found.

Action Potentials↗

Changes in cardiac muscle function and biochemistry produced by long-term amiodarone and amiodarone + triiodothyronine administration in the rabbit.

Cardiac muscle function and biochemistry were examined after long-term amiodarone administration in the rabbit (20 mg/kg/day for 28 days). Isolated cardiac muscle preparations were obtained from control and amiodarone-treated rabbits, and were studied in vitro. Amiodarone treatment did not alter the magnitude of force development in isolated atrial and papillary muscle preparations, but depressed the rate of force development (dF/dt). The muscle preparations responded similarly to inotropic and chronotropic stimulation with isoproterenol, histamine, and tyramine, although the intrinsic rate of right atrial preparations from the drug-treated animals was reduced. Na+-K+ ATPase activity in crude ventricular homogenates was increased in the amiodarone-treated group. Mitochondrial respiratory function in amiodarone-treated left ventricular tissue was depressed for glutamate, malate, and glutamate + malate. The reduction in respiratory function occurred without uncoupling oxidative phosphorylation or altering respiratory function for succinate. The pharmacologic effects of amiodarone observed in the present study were not observed with the simultaneous administration of triiodothyronine (5 micrograms/day). No difference in ATP-dependent calcium uptake or in calcium-dependent ATPase activity were observed in sarcoplasmic reticulum preparations from control, amiodarone, and amiodarone + T3 groups. The pharmacologic effects of amiodarone in rabbit hearts resemble those previously reported with hypothyroidism and are not observed after triiodothyronine administration.

Adenosine Triphosphatases↗

Atrial septostomy for pulmonary hypertension.

Atrial septostomy represents an additional, promising strategy in the treatment of severe PPH. Experience with this procedure still is limited; however, based on analyses of the worldwide experience, several general conclusions and recommendations can be made. 1. Atrial septostomy can be performed successfully in selected patients with advanced pulmonary vascular disease. 2. Patients with primary pulmonary hypertension who have undergone successful AS have shown: a significant clinical improvement beneficial and long-lasting hemodynamic effects at rest a trend toward improved survival 3. The procedure-related mortality of the collective experience is high (16%). Several recommendations can be made to minimize the risk: [figure: see text] Atrial septostomy should be attempted only in institutions with an established track record in the treatment of advanced pulmonary hypertension, where septostomy is performed with low morbidity. Atrial septostomy should not be performed in patients in whom death is impending or who have severe right ventricular failure and are on maximal cardiorespiratory support. An mRAP greater than 20 mm Hg, PVR index greater than 55 u/m2, and a predicted 1-year survival less than 40% are significant predictors of procedure-related death. Before cardiac catheterization, patients should have an acceptable baseline systemic oxygen saturation (> 90% in room air) and optimized cardiac function (adequate right heart filling pressure, additional inotropic support if necessary). During cardiac catheterization, the following are mandatory: Supplemental oxygen Mild sedation to prevent anxiety Careful monitoring of variables (left atrial pressure, SaO2, and mRAP) Step by step procedure After AS, it is important to optimize oxygen delivery. Transfusion of packed red blood cells or erythropoietin (before and following the procedure, if needed) may be necessary to increase oxygen content. 4. Because the disease process in PPH is unaffected by the procedure (late deaths), the long-term effects of an AS must be considered to be palliative. 5. Despite its risk, AS may represent a viable alternative for selected patients with severe PPH. Indications for the procedure may include: Recurrent syncope or right ventricular failure, despite maximal medical therapy, including oral calcium-channel blockers or continuous intravenous prostacyclin (Fig. 11) As a bridge to transplantation When no other option exists.

Cardiac Surgical Procedures↗

Pressure-flow studies in man: effect of atrial systole on ventricular function in mitral stenosis.

The effect of atrial contraction on left ventricular function in six patients with varying degrees of mitral stenosis was determined by utilizing the pressure gradient technique to measure instantaneous aortic blood flow and pressure. Aortic flow was measured as ventricular rate was controlled by right ventricular pacing to create A-V (atrioventricular) dissociation at varying rates (90-150 beats/min). At each heart rate, beats with preceding P waves, effective atrial systole, were grouped according to the duration of the P-R interval. Beats without P waves served as controls. There was always a significant increase in stroke volume, created by effective atrial systole, but the P-R interval at which it took place was different for each patient. There was no difference in the stroke volume for beats preceded by P waves having a P-R interval within the range of 0.05-0.20 sec. These beats were grouped for each patient, subjected to regression analysis, and compared to control beats. The absolute and percent change created by effective atrial systole was inversely proportional to the severity of the disease as determined by mitral valve orifice size. Effective atrial systole plays less of a role in augmenting left ventricular function in patients with mitral stenosis than in patients with normal valves.

Adult↗

Effects of nitric oxide synthase inhibition on Basal function and the force-frequency relationship in the normal and failing human heart in vivo.

BACKGROUND: Nitric oxide (NO) exerts autocrine/paracrine effects on cardiac function, including alterations of the inotropic state. In vitro studies suggest that NO modulates the myocardial force-frequency relationship. Basal left ventricular (LV) contractility is depressed and the force-frequency relationship is blunted in human heart failure, and it is speculated that an increase in NO production is involved. METHODS AND RESULTS: We compared the effects of intracoronary NO synthase inhibition with N(G)-monomethyl-L-arginine (L-NMMA; 25 micromol/min) on basal LV function and the response to incremental atrial pacing in patients with dilated cardiomyopathy (n=11; mean age, 51 years) and in control subjects with atypical chest pain and normal cardiac function (n=7; mean age, 54 years). In controls, L-NMMA significantly reduced basal LV dP/dt(max) (from 1826 to 1578 mm Hg/s; P<0.002), but had no effect on heart rate, mean aortic pressure, or right atrial pressure. Pacing-induced increases in LV dP/dt(max) were unaltered by L-NMMA. In patients with dilated cardiomyopathy, L-NMMA had no effect on baseline LV dP/dt(max) (from 1313 to 1337 mm Hg/s; P=NS). The blunted pacing-induced rise in LV dP/dt(max) in these patients was unaltered by L-NMMA. CONCLUSION: Endogenous NO has a small baseline positive inotropic effect in the normal human heart, which is lost in heart failure patients. NO does not significantly influence the force-frequency relationship in either the normal or failing human heart in vivo. Because this study was performed in patients with moderate heart failure, whether the findings apply to subjects with more severe heart failure requires further investigation.

Adult↗

Use of echocardiography in newborns with patent ductus arteriosus: a review.

Assessment of the contribution of left-to-right shunted ductal flow to the clinical state of a newborn with respiratory distress syndrome is difficult. Echocardiography has aided in the bedside diagnosis and management of these infants. M-mode echocardiography allows evaluation of left atrial dimension in both precordial and suprasternal planes, left ventricular dimension, and indices of function. M-mode echocardiography combined with saline contrast aortic injections allows a very sensitive demonstration of the presence of left-to-right shunting patent ductus arteriosus even if no murmur is present. Two-dimensional echocardiography demonstrates the physical appearance of the ductus and helps rule out associated congenital cardiac lesions. Incorporation of venous and arterial contrast injections help demonstrate flow direction as well. Range gated pulsed Doppler echocardiography helps evaluate flow characteristics and aids in differential diagnosis. In the future, ultrasonic evaluation will probably combine Doppler echocardiography with two-dimensional echocardiography allowing clearer noninvasive definition of anatomy and flow direction. None of these techniques should be used by itself. Careful clinical assessment by standard techniques along with judicious use of ultrasonic methodology should result in improved diagnosis and management.

Ductus Arteriosus, Patent↗

Partial atrioventricular canal defect in adults.

Between March 1955 and March 1981, 52 adult patients (age 20 years or older) with partial atrioventricular canal (PAVC) were examined at the Mayo Clinic. Forty patients were in New York Heart Association (NYHA) functional class I or II. The ECG showed right bundle branch block with left-axis deviation in 48, first-degree atrioventricular block in 33 and atrial fibrillation in nine. Preoperative catheterization was done in 37 patients; the mean pulmonary resistance index was 2.8 U.m2, and the mean pulmonary-to-systemic flow ratio was 3.0. Forty-seven patients underwent operation; two required mitral valve replacement. There were three operative deaths (6.4% operative mortality) and two late deaths. All surviving patients were in NYHA class I or II. No patient required subsequent permanent pacemaker implantation. We conclude that repair of PAVC in adults may be performed at low risk and may improve patient longevity and functional status.

Adult↗

Regression of significant tricuspid regurgitation after mitral balloon valvotomy for severe mitral stenosis.

BACKGROUND: Significant tricuspid regurgitation (TR) is occasionally associated with severe mitral stenosis and has an adverse impact on morbidity and mortality in patients undergoing mitral valve surgery. However, the effect of successful mitral balloon valvotomy (MBV) on significant TR is not fully elucidated. The aim of this study was to investigate TR after MBV in patients with severe mitral stenosis. METHODS: We analyzed the data of 53 patients with significant TR (grade > or =2, on a 1 to 3 scale) from the mitral balloon valvotomy database at our hospital. Patients were evaluated by Doppler echocardiography before valvotomy and at follow-up 1 to 13 years after MBV. Patients were divided into group A (27 patients), in whom TR regressed by > or =1 scale, and group B (26 patients), in whom TR did not regress. RESULTS: The Doppler-determined pulmonary artery systolic pressure was initially higher and decreased at follow-up more in group A (from 70.7 +/- 23.8 to 36.5 +/- 8.3 mm Hg; P < .0001) than in group B (from 48.7 +/- 17.8 to 41.6 +/- 13.1 mm Hg; P = NS). Compared with patients in group B, patients in group A were younger (25 +/-10 vs 35 +/- 11 years; P < .005), had higher prevalence of functional TR (85% vs 8%; P < .0001), and had lower incidence of atrial fibrillation (7% vs 38%; P < .005). Significant decrease in right ventricular end-diastolic dimension after MBV was noted in group A but not in group B. The mitral valve area at late follow-up was larger in group A than in group B (1.8 +/- 0.3 vs 1.6 +/- 0.3 cm2; P < .05). CONCLUSIONS: Regression of significant TR after successful MBV in patients with severe mitral stenosis was observed in patients who had severe pulmonary hypertension. This improvement in TR occurred even in the presence of organic tricuspid valve disease.

Adult↗

Left heart atrial and ventricular epicardial pacing through a left lateral thoracotomy in children: a safe approach with excellent functional and cosmetic results.

OBJECTIVE: Left heart atrial and ventricular epicardial pacing through a left lateral thoracotomy is an alternative approach for lead insertion in children, avoiding venous access complications and right ventricular stimulation, without compromising sporting or musical activities. We analyzed the survival and performance of left atrial and left ventricular epicardial pacing leads, and present mid-term follow-up data. METHODS: Seventy-five bipolar steroid eluting pacing leads (Medtronic CapSure Epi 4968) were implanted in 41 children, aged 8.6+5.1 years. Pacing systems included 34 DDDR and 7 VVIR. Pacing leads were inserted through a muscle-sparing left lateral thoracotomy, and sutured to the left atrial appendage or atrium, and to the left ventricle. The generators were buried behind the abdominal muscles or between the thoracic muscle layers. Congenital heart disease with previous cardiac surgery was present in 25 children. Indications for pacing were post-operative heart block (n=14), sinus node disease (n=13), congenital heart block (n=9), and various (n=5). Threshold values and measured data were obtained at 6-month intervals. The mean follow-up was 3.8+2.9 years. RESULTS: There was no mortality or major morbidity, with excellent functional and cosmetic results. Lead survival was 94 and 86% for atrial leads, and 97 and 86% for ventricular leads, at 1 and 5 years, respectively. There were five reoperations for lead fracture (n=2), insulation break (n=1), oversensing (n=1), and infection (n=1). Device reprogramming was required in three instances. In the absence of acute lead failure, mid-term follow-up shows very satisfactory and stable lead performance. CONCLUSIONS: Left heart atrial and ventricular epicardial pacing leads inserted through a left lateral thoracotomy demonstrate a high probability of survival, with favorable pacing characteristics, and optimal sensing thresholds at mid-term follow-up. Epicardial left heart pacing is reliable, and easy access can be achieved through a cosmetic and functional muscle-sparing left lateral thoracotomy.

Adolescent↗

Circulatory support for fulminant myocarditis: consideration for implantation, weaning and explantation.

OBJECTIVE: Fulminant myocarditis (FM) is an uncommon but life-threatening condition for which a mechanical circulatory support (MCS) device can be life-saving. However, device selection, weaning and explantation procedures remain poorly defined. METHODS: Four patients were bridged to recovery using the Thoratec biventricular support device. All four were in a state of cardiogenic shock with rapid deterioration of their clinical status despite increasing doses of inotropes. Three patients required mechanical respiratory support, three were anuric and one was dialyzed. Echocardiography showed a mean ejection fraction of 12+/-8%. RESULTS: Each Thoratec implantation was performed on cardiopulmonary bypass with a beating heart. Three patients underwent biventricular cannulation. The fourth patient underwent left ventricular and right atrial cannulation. All patients manifested evidence of moderate to severe end organ dysfunction after device implantation. However, by explantation, end organ function had recovered in all patients. After a mean duration of 17+/-10 days, all the patients showed evidence of myocardial recovery. Recovery was confirmed on echocardiography which showed opening of the aortic valve and contraction of both ventricles. The weaning process was performed in 2-5 days by setting the device in a fixed mode and increasing the rate. Device explantation was uneventful in the four patients. At the 6 months echocardiography follow-up, all had normal systolic function. CONCLUSION: In patients with FM, biventricular support allows full circulatory support and unloads both ventricles until recovery occurs. In this set of patients, weaning and removal procedures are straight-forward. These results suggest an aggressive stance toward implantation of MCS in patients with FM.

Adult↗

Repair of postinfarction ventricular septal defect through the right atrium.

Repair of post infarction posterior ventricular septal defect has generally been performed with a ventriculotomy through the infarcted zone. This approach has a significant mortality and morbidity due to haemorrhage, extension of infarction or further compromise of ventricular function secondary to suture placement. We present a case with delayed repair of a post infarction posterior septal defect using a right atrial approach, where no discrete infarct or other abnormality of the free ventricular wall was found.

Cardiac Surgical Procedures↗

Electrophysiological effects of melperone in the dog heart in situ - a new antiarrhythmic drug.

In pentobarbital anaesthetised dogs, melperone (a neuroleptic butyrophenone) reduced mean aortic blood pressure and at lower doses (0.5 and 2.5 mg . kg-1) increased the heart rate. By means of His bundle electrography and programmed electrical stimulation, conduction velocity and refractoriness were measured at different frequencies of stimulation (170, 200, 230 and 260 beats.min-1). Melperone 0.5 and 2.5 mg.kg-1 decreased the atrioventricular nodal conduction time and refractoriness. Melperone (0.5 to 12.5 mg.kg-1) did not affect the intra-atrial or His-Purkinje conduction times or the QRS width. However, melperone increased the functional and effective refractory period of the right atrium and ventricle dose-dependently at all frequencies studied. This suggests that melperone may be a valuable drug in treating selected cardiac arrhythmias.

Animals↗

Pulsatile augmentation device for extracorporeal circulation.

A device has been designed, constructed, and tested to provide pulsatile pressure/flow to a standard extracorporeal bypass circuit. The pulsatile augmentation device is pneumatically driven similar to an artificial heart ventricle except that there are no valves. It is constructed of polyurethane by vacuum forming and high frequency welding. Drivers used are a modified Arrow-Kontron intraaortic balloon pump or the Utah artificial heart driver. In vitro testing with fresh bovine blood demonstrated acceptable blood compatibility and hemodynamic function. In vivo testing for 4 h in a right and left heart extracorporeal bypass circuit showed good pulse augmentation in pulmonary and systemic bypass circuits. The device shows promise for adding pulse to standard cardiopulmonary bypass and to extracorporeal right heart circulatory assist circuits.

Animals↗

Hyponatraemia as a marker for high renin heart failure.

The factors that might activate the renin-angiotensin system in treated heart failure were explored. Serum Na+ correlated inversely with plasma renin activity. The degree of congestive heart failure measured by right atrial pressure, pulmonary capillary wedge pressure, cardiac index, and systemic vascular resistance did not correlate with plasma renin activity. Similarly, renal function as measured by blood urea nitrogen, creatinine, and urinary Na+ excretion did not correlate with plasma renin activity. In a prospectively screened group, seven patients with congestive heart failure who were found to be hyponatraemic had plasma renin activities greater than 15 ng/ml per h. Serial determinations in one patient showed plasma renin activity to vary inversely with the serum Na+. It is concluded that serum sodium can be used to identify those patients with congestive heart failure who have a high plasma renin activity. The value of identifying these high renin heart failure patients was seen in their response in four cases to specific therapy with a converting enzyme inhibitor.

Captopril↗

Anatomic correction of transposition of the great arteries associated with ventricular septal defect: midterm results in 50 patients.

From May 1977 to August 1982 50 patients who were 1.5 to 44 months old underwent anatomic correction of transposition of the great arteries (TGA) and closure of ventricular septal defect (VSD) at our institution. Thirty-nine patients underwent preliminary pulmonary arterial banding. Hospital mortality was 32%: four patients died as a result of technical problems, seven as a result of associated lesions, three of pulmonary hypertension, and two of left ventricular failure. Three other patients died after the first postoperative month (one of mediastinitis, one at reoperation for a residual VSD, and one of pulmonary hypertension). All 31 survivors are in excellent clinical condition and are in sinus rhythm after a mean follow-up period of 31 +/- 14 months. Twenty-five patients were reinvestigated by echocardiography (M mode and two-dimensional) and/or catheterization. Parameters of left ventricular contractility were within normal limits, but systolic aortic diameter was larger than normal (p less than .01). Seven patients had stenosis of the right ventricular outflow tract and five of these required reoperation. The two persistent problems with the anatomic correction of TGA associated with VSD are a relatively high operative mortality and secondary right outflow tract stenosis. However, use of this procedure results in better left ventricular function and fewer arrhythmias than does use of atrial repair techniques and also results in the use of the anatomically left ventricle as the systemic ventricle.

Cineangiography↗

Double orifice mitral valve: report of 4 cases.

Double Orifice Mitral Valve (DOMV) is a rare congenital abnormality. Reports of 4 patients with DOMV are presented. As associated anomalies, one had ostium primum atrial septal defect (ASD). Second one had Ebstein's anomaly. Third one had grade IV tricuspid regurgitation, thickened tricuspid valve and right atrial mass. Fourth one had sinus venosus ASD. Echocardiography is the gold standard investigation. Surgical treatment depends upon the mitral valve function and associated anomalies.

Adolescent↗