Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ARTIFICIAL LIMBS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86Linked to original sources

A survey of the satisfaction of upper limb amputees with their prostheses, their lifestyles, and their abilities.

Seventy Australian upper limb amputees responded to a detailed postal questionnaire asking how often they wore their prostheses and their level of satisfaction with both their prostheses and their functional abilities. Fifty-six percent of amputees wore their limbs "once in a while" or "never." Prostheses were most often worn "all the time" for work and social activities. The amount of time amputees wore their prostheses was moderately associated with their level of satisfaction with their prostheses. The association between the amount of time amputees wore their prostheses and their level of satisfaction with their functional abilities was very low. Their prostheses were rated as "fair" or "not acceptable" by 64% of amputees. Sweating was rated as "not acceptable" by 55%. This may well be a significant contributing factor to the low prosthetic use. The amputees who did not wear prostheses did not have any greater satisfaction with their ability to do the tasks they want to do than the amputees who wore prostheses.

Adult↗

Coping, affective distress, and psychosocial adjustment among people with traumatic upper limb amputations.

OBJECTIVE: This study investigated the prevalence of symptoms of depression and anxiety in a sample of predominantly elderly males with acquired upper limb amputations (n=138) and examined the contribution of coping strategies to the prediction of psychosocial adjustment. METHOD: One hundred and thirty-eight men with injury-related upper limb amputations completed self-report questionnaires assessing coping strategies, symptoms of anxiety and depression, and psychosocial adaptation to prosthesis use. RESULTS: Prevalence of significant depressive symptoms was 28.3% [Hospital Anxiety and Depression Scale, Depression subscale (HADS-D) score > or =8]. Prevalence of significant anxiety symptoms was 35.5% [HADS Anxiety subscale (HADS-A) score > or =8]. Coping styles emerged as important predictors of psychosocial adaptation. In particular, avoidance was strongly associated with psychological distress and poor adjustment. CONCLUSIONS: These findings suggest the potential benefits of interventions to reduce reliance on avoidant coping and stimulate more problem-focused approaches to coping with difficulties and challenges in order to facilitate adaptation and prevent problems in psychosocial functioning postamputation.

Adaptation, Psychological↗

Contact dermatitis to a limb prosthesis.

PROSTHESIS USERS commonly develop various skin problems on the residual limb, directly under the prosthetic device when the device is in direct contact with the skin. Prolonged occlusion and humidity increase the likelihood of developing contact sensitivity to moisturizing creams, medicaments, and materials in the prosthesis itself.1 Allergic contact dermatitis to various prosthetic design materials is uncommon, and the relevance of positive patch-test results to chemicals present in prostheses may be difficult to establish. Most reports of allergic contact dermatitis to prostheses have been concerned with surgical amputees and not congenital amputees. We report a 5-year-old boy with a transverse partial hemimelia who developed allergic contact dermatitis to an adhesive used in his myoelectric prosthesis. Unlike most prostheses, myoelectric prostheses are worn directly against the skin, for surface electromyography electrode contact.

Allergens↗

An audit of amputation levels in patients referred for prosthetic rehabilitation.

Most lower limb amputations in the United Kingdom (UK) are carried out within general surgical, orthopaedic and plastic surgical units of district hospitals. This study of patients referred for rehabilitation was undertaken to determine the number and specialty interests of surgeons referring amputees, the numbers referred by each and, as one of several possible measures of appropriateness for rehabilitation, the amputation levels in patients referred for the first time to one sub-regional Disablement Services (limb fitting) Centre (DSC) over a 14 month period. Thirty nine surgeons, referred 263 amputees. The majority (61%) of surgeons referred 5 or fewer: a nucleus of 11 vascular surgeons (28%) referred 64% of the patients. The underlying pathology, specialty interest of the surgeon or numbers referred by individual surgeons had no relation to final healed level which was below the knee in 55% of cases compared to national figures for all other DSC's ranging between 39% and 48% below-knee between 1981 and 1988. Since current practice in the UK is to refer all but the frailest patients for consideration of prosthetic rehabilitation, this study suggests that, nationally, more patients could be suited for the functionally superior below-knee level of amputation than are currently benefiting from it.

Amputation, Surgical↗

The influence of prior stroke on the prosthetic rehabilitation of lower limb amputees.

Concurrent stroke is believed to have an adverse influence on the process and outcome of prosthetic rehabilitation, but there is limited published evidence for this. The aim of this study was to establish a clearer picture in order to assist decision making for both patients and professionals. Demographic and clinical data were collected from all lower limb amputees referred from North and West Yorkshire for prosthetic rehabilitation. Additional data were collected from all new lower limb amputees in three of the referring health districts, irrespective of prosthetic referral. Patients with prior stroke were less likely to be referred for prosthetic rehabilitation. Improved mobility and independence were seen following prosthetic rehabilitation irrespective of prior stroke. The group with prior stroke compared well with the non-stroke group in terms of walking aid usage, but a smaller proportion of the stroke group were able to walk 30 m without stopping and there were trends for smaller gains in independence in the stroke group. Nevertheless, this study demonstrates that prosthetic rehabilitation can be successful in a selected amputee population with prior stroke. In those who continue prosthetic use for one year, outcome is similar to that in patients without stroke.

Amputees↗

Clinical application study of externally powered upper-limb prosthetics systems: the VA elbow, the VA hand, and the VA/NU myoelectric hand systems.

The results have been presented of a 2-year survey designed to determine whether external power systems offer a significant contribution to the needs of the upper-limb amputee or whether they represent novelties duplicating the functions of conventional mechanical components. The following conclusions have been drawn: 1. External power does offer advantages to the arm amputee. Myoelectric control, especially combined with a self-suspending socket, offers an otherwise normal partial forearm amputee better function without the necessity of a harness. External power, especially for the short partial or total arm amputee and others with limited excursion, brings increased function with less effort. For these patients the advantages of such components as the electric elbow outweigh the recent disadvantages. 2. The components evaluated in this Study are not without limitations. Maintenance requirements of the VA Elbow were excessive. The VA Elbow should not be prescribed for patients who do heavy work with their prostheses because the flexspline may break. Regarding such concerns as lack of sensory feedback, noise, weight, and flexion/extension speed, the advantages of each unit must be weighed against the disadvantages with preference to the individual amputee. 3. The endoskeletal forearm with soft cover is an advantage because of its lightness and cosmesis. 4. Because of the many malfunctions attributed to prosthetist errors, the need is evident for thorough specialized education in the field of external power. A few centralized fabrication facilities may be desirable as opposed to fabrication by many facilities with limited experience. Modular components that are interchangeable and field repairable would be desirable. The systems should be fitted, installed and repaired only by trained prosthetists who have successfully completed a course in externally powered upper-limb prostheses. All members of the Clinic Team should be thoroughly educated in external power as it is related to prosthetics. 5. Many malfunctions were due to patient misuse. Patients, too, after careful selection must be given thorough training in the care and use of externally powered components, including the limitations and capabilities of these devices. 6. Finally, and most important, the Clinic Team must be recognized as the focal point for the selection of patients and prescription of devices. Each patient must be carefully screened for information such as occupation, motivation, prosthesis use (as opposed to wear), ability to learn and follow through with instructions (charging batteries, etc.), and most importantly, the benefits that external power can offer.

Adolescent↗

Triaxial force transducer for investigating stresses at the stump/socket interface.

Although normal pressures at the stump socket interface of the lower-limb amputee have been investigated, little is known about the shear stresses that also occur. Studies suggest that the combination of both shear and normal stresses significantly exacerbates discomfort and vascular and tissue damage. A means of simultaneously measuring normal and shear stresses will aid in the investigation and improvement of prosthetic fit. A miniature triaxial force transducer (4.9 x 16 mm diameter) has been developed which can be recessed into the socket wall. The principle of operation, construction, performance and limitations of the device are described. Preliminary measurements of the interface stress variations over the gait cycle in a supra-condylar PTB socket are presented. These show clear differences in the stress patterns present when two different prosthetic feet are used.

Amputation Stumps↗

Amputee walking training: a preliminary study of biomechanical measurements of stance and balance.

Biomechanical parameters of stance and balance were recorded in ten unilateral lower limb amputees at the beginning and end of walking training. Measurements were carried out using a Double Video Forceplate (DVF), a machine developed at University College, London, Bioengineering Centre, Roehampton. During free standing on the DVF there was a mean increase in weight-bearing under the prosthetic foot from 32% body weight (1st session) to 41% body weight (final session), p less than 0.01. Maximum weight-bearing during leaning as far as possible onto the prosthesis increased from a mean of 54% body weight to 63% body weight, p less than 0.01. These simple measurements of weight distribution between the feet can be of value during walking training to monitor progress and can accurately record improvement for research purposes.

Aged↗

Ability or disability? A study of the functional outcome of 65 consecutive lower limb amputees treated at the Royal South Sydney Hospital in 1988-1989.

A follow-up study by personal interview (45) or written response (4) or next-of-kin (3) interview using a questionnaire, has been made at least 1 year from discharge of the 52 survivors (82%) of 65 lower limb amputees treated at the Royal South Sydney Hospital in the years 1988-1989. At follow-up prostheses were used by 94% of the people, 72% of the group using their prostheses all day. Independence in self-care was found to be more important to final discharge home than walking skills. The 93% return home rate was considered to be in part due to funding for home modifications provided by government sources. Car driving was a mobility aid for 25% of patients whereas public transport was used by only 9% of subjects. Some patients mentioned that the loss of pain and a feeling of well-being was a positive gain from their amputation surgery.

Activities of Daily Living↗

A device for applying static loads to prosthetic limbs of transtibial amputees during spiral CT examination.

This paper describes a device that allows the imaging of prosthetic legs under load conditions using spiral computerized tomography (CT). The device consists of a chair and a vertical footplate mounted on a 17.8 x 1.9 cm oak board that is 197 cm long. The load device can be easily positioned onto the CT bed. A subject sits in the chair and applies force by pushing the foot portion of the prosthesis against the footplate. The magnitude of the force is monitored by a digital force gauge coupled to the footplate. Because the load is borne by the hips and lower back of the subject against the chair, substantial forces can be generated and steadily maintained for the 20-45 s duration of the CT study. This device has been used successfully with 19 transtibial amputees, allowing the acquisition of spiral CT studies with half and full body weight loads.

Amputation, Surgical↗

New perspectives on nursing lower limb amputees.

New perspectives on nursing lower limb amputees arise from the author's researches into amputee rehabilitation and a summary of other recent research findings. These are dealt with in the context of basic amputee treatment and the nursing process. There is new material on the psychological and neurological sequelae of amputation, the practical problems of loss of a limb and the prosthetic dimension of treatment. The patients' reactions to lower limb amputation were found to vary from intense grief to intense relief, many noting it to be of minor or moderate consequence. The model of sudden and shocking loss is largely incorrect. Attention is drawn to an unrecognized ordinariness which should become part of amputee nursing. Patients have many practical problems. These are social and economic, personal and domestic. The ward environment is unsuited to these needs but, working closely with therapists, nurses can do much to facilitate amputee rehabilitation. The modern purpose of amputation surgery is prosthetic replacement. Nurses should be working with some urgency towards uniting patient and prosthesis. Pain and discomfort are underestimated and research shows them to be a major characteristic of amputation continually and for many years after surgery. A variety of pain syndromes are involved.

Adaptation, Psychological↗

Design and analysis of orthogonally compliant features for local contact pressure relief in transtibial prostheses.

A very attractive advantage of manufacturing prosthetic sockets using solid freeform fabrication is the freedom to introduce design solutions that would be difficult to implement using traditional manufacturing techniques. Such is the case with compliant features embedded in amputee prosthetic sockets to relieve contact pressure at the residual limb-socket interface. The purpose of this study was to present a framework for designing compliant features to be incorporated into transtibial sockets and manufacturing prototypes using selective laser sintering (SLS) and Duraform material. The design process included identifying optimal compliant features using topology optimization algorithms and integrating these features within the geometry of the socket model. Using this process, a compliant feature consisting of spiral beams and a supporting external structure was identified. To assess its effectiveness in reducing residual limb-socket interface pressure, a case study was conducted using SLS manufactured prototypes to quantify the difference in interface pressure while a patient walked at his self-selected pace with one noncompliant and two different compliant sockets. The pressure measurements were performed using thin pressure transducers located at the distal tibia and fibula head. The measurements revealed that the socket with the greatest compliance reduced the average and peak pressure by 22% and 45% at the anterior side distal tibia, respectively, and 19% and 23% at the lateral side of the fibula head, respectively. These results indicate that the integration of compliant features within the socket structure is an effective way to reduce potentially harmful contact pressure and increase patient comfort.

Amputees↗

The development of the Edinburgh modular arm system.

Modularity has not been investigated in any significant way in the development of upper-limb prostheses. The components currently available are the results of different research programmes conducted at different times by a variety of academic and commercial teams. The result is a historical hodge-podge of systems which are largely mutually exclusive in terms of compatibility. The Edinburgh work seeks to solve this problem by designing components which are neutral in structural terms so that left- and right-handed prostheses can be configured from the same basic parts. Currently, child and adult components are separate items; this does not need to be the case and the design presented here allows adult elbow parts to be used as children's shoulders. This paper will cover the rationale behind the design values and the technical aspects of the development.

Artificial Limbs↗

Modified Van Nes rotationplasty for osteosarcoma of the proximal tibia in children.

Above-knee amputation has been the traditional treatment for osteosarcoma of the proximal tibia. Recent advances in chemotherapy have encouraged the development of limb-salvage techniques. Van Nes rotationplasty for malignant lesions of the distal femur has increased in popularity as a reconstructive technique, but no similar procedure has been described for lesions of the proximal tibia. We have developed a modified rotationplasty for this lesion and have performed it in four children. The surgical technique, postoperative management and results of the procedure are described. Two patients had delayed wound healing. No other complications have developed and our patients were disease-free at follow-up, while the appearance of the leg was well accepted by the patients and their parents. This procedure is a useful addition to the armamentarium of the tumour surgeon for the treatment of malignant lesions of the proximal tibia.

Amputation, Surgical↗

Criteria for prosthetic provision: "he who pays the piper calls the tune".

Previously instituted policies regarding prosthetic limb provision had been deemed dependable. A follow-up home visit study showed that 18 of 60 patients that had been provided with prostheses, did not make use of them. Analysis showed that three categories of patients made up the large majority of the non-users; double amputees, blind persons and those with psychiatric disorders. In order to attempt to eliminate the wastage of prosthetic provision to non-ambulators a new policy decision was made. Doubtful ambulators and those from the three aforementioned categories will be initially provided with temporary prostheses. Only after a period of months of temporary prosthetic usage at home will a decision be made as to whether a permanent prosthesis will be issued.

Adult↗

A two-year longitudinal study of social support following amputation.

PURPOSE: (1) To describe one aspect of social support, social integration, longitudinally for 2 years following lower limb amputation and (2) to explore the impact of social support on depression, pain interference, life satisfaction, mobility, and occupational functioning. METHOD: Eighty-nine adults recruited from consecutive admissions to an orthopaedic surgery service completed telephone interviews 1, 6, 12 and 24 months following amputation surgery. Dependent variables included the Social Integration (SI) sub-scale of the Craig Handicap Assessment and Reporting Technique (CHART) and the Multidimensional Scale of Perceived Social Support (MSPSS). RESULTS: There was a high level of SI among most persons following lower limb amputations that was relatively unchanged in the 2 years following surgery. However, mean levels of SI were lower in this group compared to a sample without disabilities. MSPSS scores were highly variable, ranging from almost no support to the maximum amount of support. MSPSS was an important concurrent predictor of pain interference, life satisfaction, and mobility, controlling for demographic and amputation-related factors. Baseline MSPSS predicted mobility and occupational functioning 6 months post-amputation, controlling for demographic and amputation-related factors. CONCLUSIONS: Findings suggest that interventions aimed at improving the quality of social relationships after amputation may facilitate participation in activities.

Activities of Daily Living↗

Amputation for tumor of the upper arm.

In a 10-year period 35 patients underwent a proximal amputation of the upper limb because of a malignant tumor. In 27 patients a forequarter amputation was made, in one a humeroscapular disarticulation and in seven an amputation through the humerus. The observed 5-year survival was 23 per cent. Twelve out of 23 patients followed for at least 3 years also survived 3 years. Fifteen living patients were questioned concerning prosthetic use and social and psychologic factors. Only three patients used a functional (mechanical) prosthesis and only five used a cosmetic prosthesis. The other seven patients rejected the use of a prosthesis. Half of the patients had the same occupation postoperatively as preoperatively. Activities of daily living did not constitute any major problem. One of three housekeepers needed daily help. One patient seemed to have suffered obvious psychologic damage.

Adolescent↗

Sensory feedback in a myoelectric upper limb prosthesis: a preliminary report.

Upper limb prostheses are often rejected because they do not provide the sensory feedback available from a normal hand. A system for providing sensory feedback has been developed at the University of New Brunswick for use with the three-state myoelectric controls prepared in the Bioengineering Institute there. Strain gauges mounted on the forefinger of an electric hand provide information which is processed electronically to cause a tingling sensation in the patient's stump, proportional in its intensity to the pinch force in the finger. This system has been used by a patient at the Ontario Crippled Children's Centre in Toronto, since June 1976. She uses it consistently with great satisfaction and enthusiasm. It gives her a sense of competence and confidence she does not have without it.

Arm↗