Impression material thickness in stock and custom trays.

This study did not examine the accuracy of the resultant impressions. Rather, the impression material thickness in impressions made using both the highly advocated custom acrylic resin tray and in the highly used manufactured stock tray was examined. Comparison between the material thickness at the prepared tooth area revealed a mean difference in material thickness of less than 1 mm. The question of the significance of this difference remains to be answered. If the difference is not significant in the success of the impression and the resultant casting, then there are several advantages in using the manufactured stock tray; the first is economy. The average cost of a custom acrylic full arch impression tray is $3.65, compared with an average cost of slightly over $0.30 for the stock tray. The second advantage is the convenience factor. Making a custom tray requires planning, study models, laboratory time, curing interval, and finishing time. In contrast, the stock tray can be selected, adapted, and used in a single visit for both anticipated and unanticipated situations. If the difference in material thickness is significant, the custom tray is indicated. However, attention to detail in making and inserting the tray in the mouth must be observed to maximize the benefits of the custom tray.

Acrylic Resins↗

In vitro adhesion of Candida species to denture base materials.

Adhesion of Candida species to prosthetic acrylic resins is an essential first step in the pathogenesis of denture stomatitis. Data on the relative adhesion of pathogenic non-albicans Candida species to different denture base materials are sparse. The purpose of the present study was to investigate in vitro adhesion of C. albicans, C. glabrata, C. krusei and C. dubliniensis to four different denture base materials. Specimens of both heat-cured resins (Vertex(TM) Rapid Simplified and ProBase Hot) and cold-cured resins (Paladur A and Paladur B) were prepared using a novel method and the adhesion of four strains each of the foregoing Candida species evaluated microscopically using a soft imaging system. There was a significant difference in yeast adherence between Vertex and the other resins. Only C. glabrata attached to Vertex, while all the remainder of the tested species adhered to all other resins tested except ProBase, which resisted C. krusei adhesion. There was a significant difference in candidal adhesion between cold-cured and heat-cured resins for three Candida species (C. albicans, P = 0.039; C. glabrata, P = 0.002 and C. krusei, P = 0.000). The type of denture base material and whether they are heat-cured or cold-cured play an important role in modifying candidal adhesion.

Acrylic Resins↗

Radiopacity of nonmetallic root canal posts.

PURPOSE: This study determined the radiopacity of a group of nonmetallic posts. MATERIALS AND METHODS: Four specimens were cut from 7 posts, and tooth sections were cut from extracted teeth. Radiographic images of all specimens along with an aluminum step wedge were obtained on occlusal films. Optical density readings for each specimen image were determined with a transmission densitometer. Radiopacity values were subsequently calculated as equivalents of aluminum thickness. RESULTS: Analysis of variance revealed significant differences in radiopacity values among the posts (P < .001). One nonmetallic post that was made of zirconium had a radiopacity value significantly greater than that of enamel. Another, made of glass fibers, acrylic resin, and fillers, had a radiopacity that was greater than that of dentin but smaller than that of enamel. The remaining 3 nonmetallic posts had radiopacity values lower than dentin. CONCLUSION: The 3 posts with radiopacity that was lower than dentin cannot be considered sufficiently radiopaque.

Absorptiometry, Photon↗

Locating angulated abutments: a technical note.

A simple laboratory-made acrylic resin guide offers rapid location of angulated abutments after the healing abutments are removed. An impression recording the relation of the implants to the dental arch enables the choice of abutments to be made in the laboratory. The precise position and angulation of each abutment can be transferred to the mouth.

Acrylic Resins↗

Surgical obturation using a gated prosthesis.

A description is given for the fabrication of a stable, versatile surgical obturator prosthesis for the dentate patient. The wrought wire and acrylic resin prosthesis is based on the swinglock concept and allows for simple transition from wire-retained to removable obturation early in patient recovery. By using such a prosthesis, interim obturator fabrication may be delayed if the practitioner believes further healing to be desirable. In some patients, transition directly to definitive obturation may be considered.

Acrylic Resins↗

Soldering index for minimal coverage retainers.

The soldering index serves to record the precise alignment of the separate parts of a fixed partial prosthesis as positioned on the abutments. The use of an all-acrylic resin index is not as accurate as a plaster index. When impression plaster is used alone, it is difficult to place minimal coverage retainers such as inlays back into the index. This article describes a simple method that may overcome the difficulty without sacrificing the dimensional accuracy inherent in a plaster index.

Acrylic Resins↗

An in vitro study of the fracture resistance and the incidence ofvertical root fracture of pulpless teeth restored with six post-and-coresystems.

STATEMENT OF PROBLEM: Posts and cores are often required with pulpless teeth to provide retention and resistance form for complete crowns. Nevertheless, conventional posts may increase the potential for root fracture. PURPOSE: This study compared the resistance to vertical root fracture of extracted teeth treated with post-core systems that were modified with polyethylene woven fibers (Ribbond) with those treated with conventional post-and-core systems. MATERIAL AND METHODS: Canal instrumentation was performed for 60 maxillary central incisors, and complete crown preparations were made. The coronal portion of each tooth was amputated, and 6 post-and-core systems were studied. Specimens were mounted in acrylic resin blocks with a layer of polyvinyl siloxane covering the roots. Loads were applied at an angle of 130 degrees and measured with a universal testing machine. Results were analyzed statistically with 1-way analysis of variance with Student-Newman-Keuls grouping and chi-square analysis. RESULTS. Cast posts and cores resulted in significantly higher failure thresholds than all others, except for prefabricated, comparably sized, parallel-sided posts with composite cores. All failures in the group with cast posts involved fracture of the teeth, whereas 70% of the teeth with comparably sized parallel-sided posts and composite cores failed as a result of tooth fractures and 30% experienced core fractures. The woven fiber post-core system was significantly lower in strength than all others, and exhibited significantly fewer vertical root fractures. CONCLUSIONS: Polyethylene woven fiber and composite resin without a prefabricated post resulted in significantly fewer vertical root fractures, but mean failure load was the lowest. Smaller diameter prefabricated posts combined with the polyethylene woven fiber and composite cores improved resistance to failure. Traditional cast posts and cores were the strongest of the 6 post-core systems.

Acrylates↗

Tooth colour analysis by a new optoelectronic system.

The difficulties in assessing and comparing tooth shades are well documented. This pilot study introduces an alternative method of photoelectric tooth colour measurement, the silicon photodiode array apparatus. This apparatus was used to determine colorimetric values for samples of acrylic resin teeth and the results compared with colour values obtained using a conventional photoelectric tristimulus colorimeter. Whilst a significant difference was found between some colorimetric data produced by the two types of apparatus for the same sample these differences existed purely at the mathematical level and would not be perceived by a human observer.

Acrylic Resins↗

Processing changes in maxillary complete dentures.

A technique that allows for comparison of undercuts palatal thickness, and double curing has been described for measurement of curing changes in acrylic resin dentures. The technique involves a precision cast and denture positioner in front of the x-ray tube and the transfer of a lead foil strip from cast to denture. Radiographs made of this strip are projected at X20 magnification, and subsequent tracings are measured and superimposed to note shrinkage and contour changes.

Acrylic Resins↗

Changes in vertical dimension of occlusion in conventional and microwave processing of complete dentures.

An investigation was made to compare the increase in vertical dimension of occlusion in complete dentures after processing with conventional and microwave procedures. Lucitone-characterized denture base material was used for 15 sets of complete dentures cured conventionally. Justi-characterized acrylic resin and microliquid were used for 15 sets of complete dentures cured by the microwave procedure. The results of the study showed increases in vertical dimension of occlusion in both methods under 1 mm, which is considered technically acceptable. However, a statistically significant larger increase was present in the microwave technique.

Acrylic Resins↗

Microwave-cured tracheostoma vents.

This article describes a technique of making custom flexible and combined flexible/rigid tracheostoma vents. The combined flexible rigid tracheostoma vent provides a flexible material that is nonirritating in the peristomial region and maintains a patent tracheostoma by the rigidity of the hard acrylic resin section. The flexible tracheostoma vent can be easily inserted and is more comfortable than the rigid commercially available tracheostomy tube. The use of microwave-cured materials permits fabrication during a single visit. The steps involved in the fabrication of the tracheostoma vents are simple and require no elaborate laboratory equipment.

Acrylic Resins↗

[Autoradiographic determinations of carbon-14-labeled monomers and residual monomers in the tissues of Wistar rats after implantation of cold-polymerizing polymethyl methacrylate (bone cement) (author's transl)].

Self-setting acrylics, named bone cement, are taken for the reconstruction of bone defects, for the fixation of endothesis and fractures. A disadvantage of these rapid-cure acrylic compounds is the toxicity of its monomer. Infraredspectrographic measurements showed an absolute content of 12,3 per cent monomer in an acrylic-resin-compound-implant. In order to perseive the incorporation of the diffused monomer after implantation of bone cement in rats, the monomer were marked with 14C (radioactive carbon). The autoradiographic examination revealed the excretion of the marked monomer in the urine and an accumulation in kidney, liver and lungs. The results were demonstrated.

Acrylic Resins↗

Adding a posterior palatal seal to a metal-based prosthesis.

A method of adding an acrylic resin posterior palatal seal to a cast base metal palate of a maxillary complete denture is presented. The technique may be used to create the original posterior palatal seal or to enhance an existing seal. The advantages and disadvantages of the metal palate are discussed. The clinical technique is presented along with the representative laboratory metal etching information.

Acrylic Resins↗

The degree of zinc phosphate cement coverage of complete crown preparations and its effect on crown retention.

This investigation examined the amount of retentive area covered by cement under complete coverage crowns and its effect on retention. Sixty crowns of self-cured acrylic resin were prepared on 60 identical brass dies and were divided into six groups of 10 crowns each according to different cement applications. The results showed that retention was dependent on the amount of retentive area covered by the cement. The amount of cement in the occlusal part of the cementation space did not affect retention.

Acrylic Resins↗

Microwave processing of cleft palate orthopedic expansion devices.

This article describes a method for making a palatal expansion device for use in conjunction with orthopedic repositioning of the premaxilla in patients with bilateral cleft palate. The technique of constructing the devices involves the microwave processing of a permanent soft liner and a heat-cured acrylic resin in a single-stage curing cycle. The resultant expansion device has the advantages of a soft liner for retention in the nasal cavity and an oral cavity surface that is smooth and closely adapted to the tissues. A paper cover is used during the flasking process, which allows packing of materials without displacement into undesirable locations.

Acrylic Resins↗

In situ hybridization at the ultrastructural level: localization of cytomegalovirus DNA using digoxigenin labelled probes.

We describe a procedure for detecting and localizing cytomegalovirus DNA sequences based on in situ hybridization at the ultrastructural level. A digoxigenin-labelled probe, identified with an anti-digoxigenin colloidal gold-labelled antiserum, was employed on infected cells embedded in a new acrylic resin (Bioacryl). The silver enhancement method on the same specimen was used to more easily reveal the reaction also at low magnification. The immunolocalization was characterized by high specificity with virtually no background staining and a good maintenance of submicroscopic cell features.

Acrylic Resins↗

Simplified methods for fabricating tissue-supported implant-retained overdentures with retention from a resilient liner.

Resilient denture liner materials can be useful for tissue-supported implant-retained overdentures. They allow physiologic movement of the denture toward the tissues. This article presents a technique that offers several advantages over other methods of fabricating the overdenture with a resilient liner, and of transferring the superstructure: the acrylic resin base and the heat-cured resilient liner material are cured simultaneously; superstructure blockout is performed in the laboratory instead of in the mouth, where blockout is difficult; and direct transfer of the superstructure bar is more accurate and eliminates possible fracture of the duplicated superstructure if formed in die stone.

Acrylic Resins↗

Polyvinyl siloxane impression materials: a review of properties and techniques.

Polyvinyl siloxane impression materials have been shown to have excellent properties as impression materials; however, they are sensitive to manipulative variables. Several methods of using very high viscosity (putty) materials to form "trays" to obtain uniform bulk of the wash impression are described, and the disadvantages of each of these techniques is pointed out. It is recommended that for best results acrylic resin custom trays should be used routinely. The interaction of polyvinyl siloxane materials with latex products is also discussed and problems that this inhibition can cause are stated. Suggestions to avoid this interaction are outlined. One of the disadvantages of the impression materials is that it has a relatively short working time. Refrigerating the material will increase working time without affecting accuracy.

Acrylic Resins↗